1.Application of colloidal gold method and chemiluminescence method for detecting gonadotropins in morning urine to assess pubertal development status in children.
Xue-Qi ZHAO ; Wen-Li LU ; Wen-Ying LI ; Jun-Qi WANG ; Zhi-Ya DONG ; Yuan XIAO ; Xiao-Fei ZHANG ; Li JIANG ; Xiao-Yu MA
Chinese Journal of Contemporary Pediatrics 2025;27(2):199-204
OBJECTIVES:
To explore the application of the colloidal gold method and chemiluminescence method in detecting gonadotropin (Gn) in morning urine for assessing pubertal development status in children.
METHODS:
A total of 132 children diagnosed with central precocious puberty (CPP), early and fast puberty (EFP), and premature thelarche (PT) at Ruijin Hospital Affiliated to Shanghai Jiao Tong University School of Medicine from November 2021 to December 2022 were included, along with 685 healthy children who underwent routine health examinations at the hospital's pediatric health care department during the same period. All 132 patients underwent a gonadotropin-releasing hormone (GnRH) stimulation test. Both patients and healthy children had their urinary Gn levels measured using the colloidal gold method and chemiluminescence method, including levels of luteinizing hormone (LH) and follicle-stimulating hormone (FSH). The correlation between serum Gn and urinary Gn detected by the two methods, as well as the correlation between Tanner stages of healthy children and urinary Gn, was analyzed.
RESULTS:
Urine Gn levels detected by both the colloidal gold method and chemiluminescence method showed a positive correlation with serum LH baseline values, LH peak values, baseline LH/FSH ratios, and peak LH/FSH ratios (P<0.05). In healthy children, urinary LH levels detected by the chemiluminescence method gradually increased from Tanner stage Ⅰ to Ⅳ (P<0.05), while urinary FSH levels were lower in Tanner stage I than in stages Ⅱ, Ⅲ, and IV (P<0.05). Urinary LH levels detected by the colloidal gold method were lower in Tanner stage I compared to stages Ⅱ, Ⅲ, and IV, with the highest levels observed in Tanner stage Ⅳ (P<0.05). Additionally, urinary FSH levels in Tanner stage Ⅲ were higher than in stages Ⅰ and Ⅱ (P<0.05). The area under the receiver operating characteristic curve for evaluating Tanner stages I and II in healthy children using urinary LH and FSH levels by the chemiluminescence method and urinary LH levels by the colloidal gold method were 0.730, 0.699, and 0.783, respectively.
CONCLUSIONS
The colloidal gold method and chemiluminescence method for detecting Gn in morning urine show good correlation with serum Gn levels. As a non-invasive and convenient detection method, the colloidal gold method can serve as a useful tool for screening the onset of pubertal development in children.
Humans
;
Child
;
Male
;
Female
;
Gold Colloid
;
Luminescent Measurements/methods*
;
Gonadotropins/urine*
;
Puberty
;
Luteinizing Hormone/urine*
;
Child, Preschool
;
Adolescent
;
Follicle Stimulating Hormone/urine*
2.Cyclic fatigue resistance of nickel-titanium files made by Gold heat treatment in simulated S-shaped root canals at different temperatures.
Journal of Peking University(Health Sciences) 2025;57(1):136-141
OBJECTIVE:
To compare the cyclic fatigue resistance of nickel-titanium files made by 3 new heat treatment in simulated S-shaped root canals at different temperatures.
METHODS:
Gold heat-treated nickel-titanium files TruNatomy (25 mm, tip size 26#/0.04) and ProTaper Gold (25 mm, tip size 25#/0.08) were selected as the experimental group, M wire technique nickel-titanium file ProTaper Next (25 mm, tip size 25#/0.06) was selected as the control group. It was speculated that the Gold technique used in TruNatomy nickel-titanium file was R phase separation technique, which included a complete intermediate R-phase, increasing its flexibility. ProTaper Gold was a CM wire nickel-titanium file and the increased phase transformation temperature by heat treatment introduced martensite at room temperature, while it underwent gold heat treatment on the surface, generating an intermediate R phase during phase transformation, providing hyperelastic. ProTaper Next used M wire technique, M wire included austenite at room temperature, where heat mechanical processing introduced hardened martensite, which was incapable of participating phase transformation. Because of the lower elastic modulus of hardened martensite than austenite, the flexibility of the file was increased. Twenty instruments of each nickel-titanium file were submitted to the cyclic fatigue test by using a simulated canal with double curvatures at room tem-perature (24 ℃) and 65 ℃, 10 instruments of each nickel-titanium file were selected at each temperature (n=10). At the same temperature, the number of cyclic fatigue (NCF) and fragment length were analyzed by using One-Way analysis of variance at a significance level of P < 0.05. NCF and fragment length of the same nickel-titanium file at room temperature and 65 ℃ were compared by paired sample t test and the significance level was α=0.05. Fractured surfaces were analyzed by using scanning electron microscope.
RESULTS:
In double-curved canals, all the failure of the files due to cyclic fatigue was first seen in the apical curvature before the coronal curvature. At room temperature, in the apical curvature, NCF of TruNatomy was 344.4±96.6, ProTaper Gold was 175.0±56.1, ProTaper Next was 133.3±39.7, NCF of Tru Natomy was the highest (P < 0.05). In the coronal curvature, NCF of TruNatomy was 618.3± 75.3, ProTaper Gold was 327.5±111.8, ProTaper Next was 376.6±67.9, NCF of TruNatomy was also the highest (P < 0.05). There was no significant difference among the apical and coronal fragment length of the 3 nickel-titanium files (P>0.05). At 65 ℃, in the apical curvature, NCF of TruNatomy was 289.6±65.8, ProTaper Gold was 187.5±75.4, ProTaper Next was 103.0±38.5, NCF of TruNatomy was the highest (P < 0.05). In the coronal curvature, NCF of TruNatomy was 454.2±45.4, ProTaper Gold was 268.3±31.4, ProTaper Next was 283.8±31.7, NCF of TruNatomy was also the highest (P < 0.05). The apical fragment length of ProTaper Next was the highest (P < 0.05), and there was no significant difference among coronal fragment length of the 3 nickel-titanium files (P>0.05). Compared with room temperature, at 65 ℃, in the coronal curvature, NCF of TruNatomy decreased significantly (P < 0.05). The fractured surfaces of the three nickel-titanium files demonstrated typical cyclic fatigue.
CONCLUSION
Gold heat-treated nickel-titanium file had better cyclic fatigue resistance than M wire nickel-titanium file in S-shaped root canals.
Nickel/chemistry*
;
Titanium/chemistry*
;
Hot Temperature
;
Root Canal Preparation/methods*
;
Humans
;
Materials Testing
;
Gold/chemistry*
;
Dental Alloys/chemistry*
;
Stress, Mechanical
3.A rapid method for detecting prfA and hly toxin genes of Listeria monocytogenes using double nucleic acid colloidal gold strips.
Yan LIU ; Jianyu YANG ; Yujiao ZHOU ; Wenbo DING ; Xianyu ZHANG ; Linran GAO ; Beizhen PAN ; Jifei YANG ; Yundong ZHAO
Journal of Southern Medical University 2025;45(2):387-394
OBJECTIVES:
To detect prfA and hly toxin genes of Listeria monocytogenes using polymerase chain reaction (PCR) and colloidal gold technology.
METHODS:
L. monocytogenes DNA was extracted by boiling method. With prfA and hly of L. monocytogenes as the target genes, the 5' ends of upstream and downstream primers of prfA gene were labeled with 6-FAM and biotin, and the 5' ends of upstream and downstream primers of hly gene were labeled with digoxin and biotin, respectively, to establish the toxin gene detection method. Using cloning transformation, sequencing analysis, cloning of positive control products, the detection kid was developed and its specificity, sensitivity, reproducibility and stability were tested, followed by verification with sample testing.
RESULTS:
The concentration of L. monocytogenes DNA extracted by boiling method was 148.81±0.97 ng/μL, and the A260/A280 ratio ranged from 1.8 to 2.0. The PCR products showed a 100% homology with the gene sequences in GenBank database after cloning, transformation and sequencing. The colloidal gold strip yielded positive results only for L. monocytogenes samples without cross-reactions with Staphylococcus aureus, Escherichia coli or Bacillus cereus, and its minimum detection limit was 10-2 ng/μL, demonstrating a 10-fold greater sensitivity of the test than agarose gel electrophoresis. The test also showed good reproducibility of the results when performed by different operators with good stability of the test strips after storage for 6 to 12 months. The test results showed that this kit could accurately and quickly detect L.monocytogenes in the test samples.
CONCLUSIONS
The detection kit developed in this study can simultaneously detect prfA and hly toxin genes of L. monocytogenes with good specificity, sensitivity, reproducibility and stability for use in food safety inspection.
Listeria monocytogenes/isolation & purification*
;
Gold Colloid
;
Bacterial Toxins/genetics*
;
Polymerase Chain Reaction/methods*
;
Hemolysin Proteins/genetics*
;
Bacterial Proteins/genetics*
;
DNA, Bacterial/genetics*
;
Food Microbiology
;
Heat-Shock Proteins
4.Development of a colloidal gold based immunochromatographic strip for 8-OHdG detection.
Weiwei YE ; Liwen WANG ; Yu ZHANG ; Chaofeng LI ; Tianrun QIAN ; Xianshu FU ; Mingzhou ZHANG ; Jihong SHAN
Chinese Journal of Biotechnology 2022;38(3):1197-1208
8-hydroxy-2'-deoxyguanosine (8-OHdG) is a sensitive and stable biomarker for evaluating DNA oxidative damage. A rapid and sensitive colloidal gold immunochromatographic strip was developed for 8-OHdG detection by a competitive method. The sample pad (glass cellulose film), bonding pad (glass cellulose film), nitrocellulose film and absorbent pad were pasted on the polyvinyl chloride (PVC) base plate to construct the test strip. Colloidal gold (AuNPs) was prepared by the reduction of chloroauric acid with sodium citrate. 8-OHdG antibody (Ab) was coated on the outer layer of AuNPs to form Ab@AuNPs as a probe. Bovine serum albumin (BSA) and 8-OHdG were conjugated with carbodiimide hydrochloride to prepare an artificial antigen, which was used as the coating antigen of detection line. Goat anti mouse polyclonal antibody IgG was used as the coating antibody of control line. The experimental parameters were optimized including the type of nitrocellulose membrane, the formula of loading solution, and the spraying amount of gold labeled antibody. The results showed that the appropriate nitrocellulose membrane was CN 95. The optimal loading solution included BSA (1%), Tween-20 (3%), sucrose (3%) and NaCl (0.9%). The optimal spraying amount of gold labeled antibody was 4 μL. 8-OHdG can be detected by the strip under visible light, and the level of 8-OHdG in urine can be preliminarily determined by comparing the color intensity of T line and C line. The 8-OHdG concentration in urine was further calculated by the gray value of T line and the threshold of detection was 2.55 μg/L. This colloidal gold immunochromatographic strip is simple, rapid and specific for detecting 8-OHdG in human urine to preliminarily evaluate the human status.
8-Hydroxy-2'-Deoxyguanosine
;
Animals
;
Antibodies, Monoclonal
;
Gold
;
Gold Colloid/chemistry*
;
Metal Nanoparticles
;
Mice
;
Sensitivity and Specificity
5.Evaluation of Colloidal Gold Immunochromatography for the Diagnosis of Human Brucellosis Caused by Smooth Brucella.
Shuai Bing DONG ; Na TA ; Li Ping WANG ; Meng Guang FAN ; Yue Xi LI ; Cui Hong ZHANG ; Li Jie ZHANG ; Zi Jun WANG ; Hai JIANG
Biomedical and Environmental Sciences 2022;35(8):764-767
6.Colloidal gold immunochromatographic test strip for virus detection: a review.
Xuxu DONG ; Wei SUN ; Pan CAO ; Xiaodan LIU
Chinese Journal of Biotechnology 2022;38(9):3243-3254
Colloidal gold immunochromatographic strip is a fast, sensitive and accurate solid-phase labeling detection technology, which has the advantages of low price, easy operation, rapid detection and high specificity, with the potential to qualitatively detect the relevant viruses in a short time with desired sensitivity and accuracy. It effectively addresses the disadvantages of long detection time, equipment inconvenience and professionalism requirement of the traditional detection methods used in the medical, veterinary, animal, plant virus detection, pesticide residue detection and other areas. Presently, the technology has been applied in the detection of bacterial diseases, viral diseases and prevention of extensive spread of infectious diseases, and has sufficient room for further development. This review summarizes the application of colloidal gold immunochromatography strip for biological virus detection, followed by prospecting future perspectives.
Animals
;
Antibodies, Monoclonal/chemistry*
;
Chromatography, Affinity
;
Gold Colloid/chemistry*
;
Pesticide Residues
;
Sensitivity and Specificity
7.A rapid colloidal gold immunochromatographic assay for the diagnosis of coronavirus disease 2019.
Xiao-Ling WANG ; Lei WANG ; Chao-Lu HASI ; Yu-Po WANG ; Ajab KHAN ; Bin-Zhi REN ; Zhi-Zhen LIU ; Shun-Lin HOU ; Li-Hong YANG ; Liao-Yun ZHANG ; Yong-Kang DONG ; Jun XU ; Jun XIE
Chinese Medical Journal 2020;133(16):1986-1988
8.Preparation of an anti-cotinine monoclonal antibody and its application in immunological detection.
Yajing LEI ; Lifang ZHOU ; Anxing WANG ; Shuqing CHEN
Journal of Zhejiang University. Medical sciences 2020;49(6):765-771
OBJECTIVE:
To prepare monoclonal antibody against cotinine (COT) and to establish immunoassay for detecting COT in human urinary samples.
METHODS:
BALB/c mice were immunized with synthesized cotinine-bovine serum albumin (COT-BSA) to screen monoclonal antibody with technique of cell fusion. The monoclonal antibody was used for the indirect competitive enzyme-linked immunosorbent assay (ic-ELISA) and colloidal gold immunochromatographic strip assay for the detection of COT in human urine.
RESULTS:
The monoclonal antibody against COT was identified by ic-ELISA with a 50%inhibitive concentration (IC
CONCLUSIONS
The ic-ELISA and colloidal gold immunochromatographic strip assay using the prepared monoclonal antibody against COT have been proved to be reliable for the rapid detection of COT in human urines, which may be used for monitoring of environmental tobacco smoke.
Animals
;
Antibodies, Monoclonal
;
Cotinine/urine*
;
Enzyme-Linked Immunosorbent Assay
;
Gold Colloid
;
Humans
;
Mice
;
Mice, Inbred BALB C
;
Urinalysis/methods*
9.Colloidal gold immunochromatographic strip for rapid detection of Haemophilus influenzae.
Ye TAO ; Huiwen HAO ; Jie LI ; Meng WANG ; Yi WANG ; Gaiping ZHANG ; Zheng HU
Chinese Journal of Biotechnology 2019;35(5):901-909
To establish a novel colloidal gold immunochromatography assay (GICA) for rapid, sensitive and accurate detection of Haemophilus influenzae infection by using the outer membrane protein P6 as detection target. First, the linear antigen epitope located in the extracellular domain of the P6 protein (GenBank accession number: AGH02799) was predicted by bioinformatics analysis. The region (62-75 aa of the protein) with strong antigen specificity was chosen and synthesized. Two rabbits were then immunized by the polypeptides (14 aa) for production of polyclonal antibodies. Then, the recombinant P6 proteins were also obtained to produce polyclonal antibodies. Finally, based on the two antibodies, a novel colloidal GICA for detection of Haemophilus influenzae infection was established and the specificity, sensitivity, repeatability and stability of this method were evaluated. At the same time, the method was tested in clinical simulation, and the plate culture method was used to verify its accuracy. The test strip for Haemophilus influenzae infection was successfully prepared. The detection limit of the test strip was as low as 1×105 CFU/mL and the whole process can be completed within 15 minutes. The strip specifically recognized Haemophilus influenzae and did not react with nine of other common respiratory pathogens such as Streptococcus pneumoniae, Moraxella catarrhalis, Mycoplasma pneumonia, and Legionella pneumophila. And the strips could be stored at 25 °C for at least 6 months without losing sensitivity or specificity. The coincidence rate between the results of 200 clinical samples and the plate culture method was 90.5%. Haemophilus influenzae protein P6, which possessed a high degree of surface antigen accessibility and antigencity, could be used as a marker for Haemophilus influenzae detection. The immunochromatographic colloidal gold test strip which bears the features of rapidity, convenience and sensitivity provides a unique tool for the on-site surveillance and diagnosis of Haemophilus influenzae infection in clinical test.
Animals
;
Chromatography, Affinity
;
instrumentation
;
Diagnostic Tests, Routine
;
standards
;
Gold Colloid
;
chemistry
;
Haemophilus Infections
;
diagnosis
;
Haemophilus influenzae
;
Humans
;
Limit of Detection
;
Rabbits
;
Sensitivity and Specificity
10.Development of Colloidal Gold Detector Instrument Based on CMOS Image Processing.
Chinese Journal of Medical Instrumentation 2019;43(2):112-114
This paper introduces a kind of immune colloidal gold detector instrument from the aspects of machinery,hardware and software.The instrument first collects one image through a CMOS sensor and then analyzes the image with image processing algorithm on Linux platform.Firstly,the instrument sets and stores the parameters separately for each test item,and then calls the saved item parameters when testing the item sample.So,the instrument can be used in a variety of fields and items.In this paper,a quantitative experimental test on C-reactive protein sample was performed,and the results indicate the coefficient of determination what denoted equal to 0.99,and the repeatability is greater than 93%.
Algorithms
;
Gold Colloid
;
Image Processing, Computer-Assisted
;
instrumentation

Result Analysis
Print
Save
E-mail