1.Down-Regulation of TGF-β Expression Sensitizes the Resistance of Hepatocellular Carcinoma Cells to Sorafenib.
Dongxu KANG ; Zhezhu HAN ; Geun Hyeok OH ; Yeonsoo JOO ; Hye Jin CHOI ; Jae J SONG
Yonsei Medical Journal 2017;58(5):899-909
PURPOSE: Sorafenib, a multikinase inhibitor, is the standard therapy for patients with advanced-stage hepatocellular carcinoma (HCC). However, resistance develops to the treatment, therefore, we tried to unravel the underlying mechanism in the resistance of HCC cells to sorafenib via the development of more effective therapeutic strategies. MATERIALS AND METHODS: Various liver cancer cell lines were treated with either sorafenib only or with sorafenib after infection of adenovirus expressing short hairpin RNA (shRNA) against transforming growth factor-β (TGF-β) and p38 activity was examined using western blotting. RESULTS: p38 MAP kinase activity was inhibited by low concentrations of sorafenib, which could potentially lead to sorafenib resistance in HCC cell lines. Subsequently, we used constitutive form of MKK3/6 (MKK3/6E) to confirm that massive cell death was induced by the activation of p38, and demonstrated the ability to activate p38 without any stimulation. In addition, sorafenib resistance was reduced by the activation of p38. Subsequently, we confirmed that TGF-β shRNA effectively recovered the phosphorylation of p38 inhibited by sorafenib, and increased the sensitivity of HCC cells to sorafenib, thereby inducing cell death and overcoming the resistance of HCC cells to sorafenib. CONCLUSION: Our study provides a new therapeutic strategy for HCC that overcomes the resistance of HCC to sorafenib by down-regulation of TGF-β.
Adenoviridae
;
Blotting, Western
;
Carcinoma, Hepatocellular*
;
Cell Death
;
Cell Line
;
Down-Regulation*
;
Humans
;
Liver Neoplasms
;
p38 Mitogen-Activated Protein Kinases
;
Phosphorylation
;
RNA, Small Interfering
2.Study for Multi Channel Radiation Detector Using of Microfilm and Carbon Electrode.
Kyo Chul SHIN ; Hyong Geun YUN ; Dong Hyeok JEONG ; Yong Kee OH ; Jhin Kee KIM ; Ki Hwan KIM ; Jeung Kee KIM
Korean Journal of Medical Physics 2005;16(3):111-115
We have designed the multi channel detector for the quality assurance of clinical photon beams. The detector was composed of solid phantom inserted by six plane-parallel ionization chambers at different depth. The chamber as a mini plane parallel chamber was made of carbon coated microfilms. In this study the electrical characteristics of the six chambers in the solid phantom were evaluated using 6 MV photon beam. The leakage currents were less than 0.5 pA, reproducibility was less than 0.5%, linearity was less than 0.5%, and dose rate effect was less than 0.7%. In addition the effect of dose variation from other chambers was estimated to maximum 0.8% approximately. The developed detector can be used for quality determination in output dosimetry or measurement of percentage depth dose approximately for clinical photon beam.
Carbon*
;
Electrodes*
3.Endoscopic Retrieval of a Proximally Migrated Stent in the Dorsal Duct of Pancreas Divisum.
Chul Sung PARK ; Jong Hyeok KIM ; Na Rae JOO ; Chin Woo KWON ; Hae Geun SONG ; Joon Ho MOON ; Jae One JUNG ; Woon Geon SHIN ; Jong Pyo KIM ; Kyoung Oh KIM ; Cheol Hee PARK ; Taeho HAHN ; Kyo Sang YOO ; Sang Hoon PARK ; Choong Kee PARK
Korean Journal of Gastrointestinal Endoscopy 2006;33(1):58-62
Endoscopic treatment of chronic pancreatitis by stent insertion is an accepted procedure, but various complications can be induced, including proximal migration of the stent. Many techniques are used to retrieve proximally migrated, pancreatic stents. We here report a case of a proximally migrated stent into the dorsal duct of a pancreas divisum, which was retrieved endoscopically by using a mini-snare. A 39-year-old female patient had chronic pancreatitis with divisum. A stent was inserted into the dorsal duct to relieve the chronic pain. After two months, sudden epigastric pain developed due to proximal migration of the stent. The pancreatic stent was retrieved successfully with one endoscopic attempt using a mini-snare. The epigastric pain resolved after retrieval of the stent. Our observation is that pancreatic stent migration may cause severe abdominal pain and that endoscopic retrieval is possible.
Abdominal Pain
;
Adult
;
Chronic Pain
;
Female
;
Humans
;
Pancreas*
;
Pancreatitis, Chronic
;
Stents*
4.A Case of Adenosquamous Carcinoma of the Papilla of Vater.
Hae Geun SONG ; Kyo Sang YOO ; Na Rae JU ; Jin Chul PARK ; Jae One JUNG ; Woon Geon SHIN ; Joon Ho MOON ; Jong Pyo KIM ; Kyoung Oh KIM ; Cheol Hee PARK ; Taeho HAHN ; Sang Hoon PARK ; Jong Hyeok KIM ; In Jae LEE ; Soo Kee MIN ; Choong Kee PARK
The Korean Journal of Gastroenterology 2006;48(2):132-136
Adenosquamous carcinoma of the papilla of Vater is a rare tumor and only a few cases have been reported so far. Here, we report a case of adenosquamous carcinoma in a 76-year-old male who presented with jaundice and right upper quadrant abdominal pain. Ultrasonography and enhanced abdominal CT scans showed dilated common bile duct (CBD) and intrahepatic bile duct (IHD) with a suspicious obstructing mass in distal CBD. On endoscopy, obstructing and ulcerated mass was noted on the papilla of Vater. Histopathological inspection of the biopsied specimens from mass showed adenosquamous cell carcinoma of the papilla of Vater. Since the patient refused operation, we inserted a self-expandable metallic stent in distal CBD. This is the first case report on adenosquamous carcinoma of the papilla of Vater in Korea.
Aged
;
Ampulla of Vater/*pathology
;
Carcinoma, Adenosquamous/*diagnosis/pathology/surgery
;
Cell Differentiation
;
Humans
;
Immunohistochemistry
;
Male
;
Tomography, X-Ray Computed
5.Robotic-Assisted Spine Surgery: Role in Training the Next Generation of Spine Surgeons
Jun Seok LEE ; Dong Wuk SON ; Su Hun LEE ; Jong Hyeok LEE ; Young Ha KIM ; Sang Weon LEE ; Bu Kwang OH ; Soon Ki SUNG ; Geun Sung SONG ; Seong YI
Neurospine 2024;21(1):116-127
Objective:
This study aimed to assess the degree of interest in robot-assisted spine surgery (RASS) among residents and to investigate the learning curve for beginners performing robotic surgery.
Methods:
We conducted a survey to assess awareness and interest in RASS among young neurosurgery residents. Subsequently, we offered a hands-on training program using a dummy to educate one resident. After completing the program, the trained resident performed spinal fusion surgery with robotic assistance under the supervision of a mentor. The clinical outcomes and learning curve associated with robotic surgery were then analyzed.
Results:
Neurosurgical residents had limited opportunities to participate in spinal surgery during their training. Despite this, there was a significant interest in the emerging field of robotic surgery. A trained resident performed RASS under the supervision of a senior surgeon. A total of 166 screw insertions were attempted in 28 patients, with 2 screws failing due to skiving. According to the Gertzbein-Robbins classification, 85.54% of the screws were rated as grade A, 11.58% as grade B, 0.6% as grade C, and 1.2% as grade D. The clinical acceptance rate was approximately 96.99%, which is comparable to the results reported by senior experts and time per screw statistically significantly decreased as experience was gained.
Conclusion
RASS can be performed with high accuracy within a relatively short timeframe, if residents receive adequate training.
6.Robotic-Assisted Spine Surgery: Role in Training the Next Generation of Spine Surgeons
Jun Seok LEE ; Dong Wuk SON ; Su Hun LEE ; Jong Hyeok LEE ; Young Ha KIM ; Sang Weon LEE ; Bu Kwang OH ; Soon Ki SUNG ; Geun Sung SONG ; Seong YI
Neurospine 2024;21(1):116-127
Objective:
This study aimed to assess the degree of interest in robot-assisted spine surgery (RASS) among residents and to investigate the learning curve for beginners performing robotic surgery.
Methods:
We conducted a survey to assess awareness and interest in RASS among young neurosurgery residents. Subsequently, we offered a hands-on training program using a dummy to educate one resident. After completing the program, the trained resident performed spinal fusion surgery with robotic assistance under the supervision of a mentor. The clinical outcomes and learning curve associated with robotic surgery were then analyzed.
Results:
Neurosurgical residents had limited opportunities to participate in spinal surgery during their training. Despite this, there was a significant interest in the emerging field of robotic surgery. A trained resident performed RASS under the supervision of a senior surgeon. A total of 166 screw insertions were attempted in 28 patients, with 2 screws failing due to skiving. According to the Gertzbein-Robbins classification, 85.54% of the screws were rated as grade A, 11.58% as grade B, 0.6% as grade C, and 1.2% as grade D. The clinical acceptance rate was approximately 96.99%, which is comparable to the results reported by senior experts and time per screw statistically significantly decreased as experience was gained.
Conclusion
RASS can be performed with high accuracy within a relatively short timeframe, if residents receive adequate training.
7.Robotic-Assisted Spine Surgery: Role in Training the Next Generation of Spine Surgeons
Jun Seok LEE ; Dong Wuk SON ; Su Hun LEE ; Jong Hyeok LEE ; Young Ha KIM ; Sang Weon LEE ; Bu Kwang OH ; Soon Ki SUNG ; Geun Sung SONG ; Seong YI
Neurospine 2024;21(1):116-127
Objective:
This study aimed to assess the degree of interest in robot-assisted spine surgery (RASS) among residents and to investigate the learning curve for beginners performing robotic surgery.
Methods:
We conducted a survey to assess awareness and interest in RASS among young neurosurgery residents. Subsequently, we offered a hands-on training program using a dummy to educate one resident. After completing the program, the trained resident performed spinal fusion surgery with robotic assistance under the supervision of a mentor. The clinical outcomes and learning curve associated with robotic surgery were then analyzed.
Results:
Neurosurgical residents had limited opportunities to participate in spinal surgery during their training. Despite this, there was a significant interest in the emerging field of robotic surgery. A trained resident performed RASS under the supervision of a senior surgeon. A total of 166 screw insertions were attempted in 28 patients, with 2 screws failing due to skiving. According to the Gertzbein-Robbins classification, 85.54% of the screws were rated as grade A, 11.58% as grade B, 0.6% as grade C, and 1.2% as grade D. The clinical acceptance rate was approximately 96.99%, which is comparable to the results reported by senior experts and time per screw statistically significantly decreased as experience was gained.
Conclusion
RASS can be performed with high accuracy within a relatively short timeframe, if residents receive adequate training.
8.Robotic-Assisted Spine Surgery: Role in Training the Next Generation of Spine Surgeons
Jun Seok LEE ; Dong Wuk SON ; Su Hun LEE ; Jong Hyeok LEE ; Young Ha KIM ; Sang Weon LEE ; Bu Kwang OH ; Soon Ki SUNG ; Geun Sung SONG ; Seong YI
Neurospine 2024;21(1):116-127
Objective:
This study aimed to assess the degree of interest in robot-assisted spine surgery (RASS) among residents and to investigate the learning curve for beginners performing robotic surgery.
Methods:
We conducted a survey to assess awareness and interest in RASS among young neurosurgery residents. Subsequently, we offered a hands-on training program using a dummy to educate one resident. After completing the program, the trained resident performed spinal fusion surgery with robotic assistance under the supervision of a mentor. The clinical outcomes and learning curve associated with robotic surgery were then analyzed.
Results:
Neurosurgical residents had limited opportunities to participate in spinal surgery during their training. Despite this, there was a significant interest in the emerging field of robotic surgery. A trained resident performed RASS under the supervision of a senior surgeon. A total of 166 screw insertions were attempted in 28 patients, with 2 screws failing due to skiving. According to the Gertzbein-Robbins classification, 85.54% of the screws were rated as grade A, 11.58% as grade B, 0.6% as grade C, and 1.2% as grade D. The clinical acceptance rate was approximately 96.99%, which is comparable to the results reported by senior experts and time per screw statistically significantly decreased as experience was gained.
Conclusion
RASS can be performed with high accuracy within a relatively short timeframe, if residents receive adequate training.
9.Robotic-Assisted Spine Surgery: Role in Training the Next Generation of Spine Surgeons
Jun Seok LEE ; Dong Wuk SON ; Su Hun LEE ; Jong Hyeok LEE ; Young Ha KIM ; Sang Weon LEE ; Bu Kwang OH ; Soon Ki SUNG ; Geun Sung SONG ; Seong YI
Neurospine 2024;21(1):116-127
Objective:
This study aimed to assess the degree of interest in robot-assisted spine surgery (RASS) among residents and to investigate the learning curve for beginners performing robotic surgery.
Methods:
We conducted a survey to assess awareness and interest in RASS among young neurosurgery residents. Subsequently, we offered a hands-on training program using a dummy to educate one resident. After completing the program, the trained resident performed spinal fusion surgery with robotic assistance under the supervision of a mentor. The clinical outcomes and learning curve associated with robotic surgery were then analyzed.
Results:
Neurosurgical residents had limited opportunities to participate in spinal surgery during their training. Despite this, there was a significant interest in the emerging field of robotic surgery. A trained resident performed RASS under the supervision of a senior surgeon. A total of 166 screw insertions were attempted in 28 patients, with 2 screws failing due to skiving. According to the Gertzbein-Robbins classification, 85.54% of the screws were rated as grade A, 11.58% as grade B, 0.6% as grade C, and 1.2% as grade D. The clinical acceptance rate was approximately 96.99%, which is comparable to the results reported by senior experts and time per screw statistically significantly decreased as experience was gained.
Conclusion
RASS can be performed with high accuracy within a relatively short timeframe, if residents receive adequate training.
10.Clinical Practice Guideline for Stroke Rehabilitation in Korea 2016.
Deog Young KIM ; Yun Hee KIM ; Jongmin LEE ; Won Hyuk CHANG ; Min Wook KIM ; Sung Bom PYUN ; Woo Kyoung YOO ; Suk Hoon OHN ; Ki Deok PARK ; Byung Mo OH ; Seong Hoon LIM ; Kang Jae JUNG ; Byung Ju RYU ; Sun IM ; Sung Ju JEE ; Han Gil SEO ; Ueon Woo RAH ; Joo Hyun PARK ; Min Kyun SOHN ; Min Ho CHUN ; Hee Suk SHIN ; Seong Jae LEE ; Yang Soo LEE ; Si Woon PARK ; Yoon Ghil PARK ; Nam Jong PAIK ; Sam Gyu LEE ; Ju Kang LEE ; Seong Eun KOH ; Don Kyu KIM ; Geun Young PARK ; Yong Il SHIN ; Myoung Hwan KO ; Yong Wook KIM ; Seung Don YOO ; Eun Joo KIM ; Min Kyun OH ; Jae Hyeok CHANG ; Se Hee JUNG ; Tae Woo KIM ; Won Seok KIM ; Dae Hyun KIM ; Tai Hwan PARK ; Kwan Sung LEE ; Byong Yong HWANG ; Young Jin SONG
Brain & Neurorehabilitation 2017;10(Suppl 1):e11-
“Clinical Practice Guideline for Stroke Rehabilitation in Korea 2016” is the 3rd edition of clinical practice guideline (CPG) for stroke rehabilitation in Korea, which updates the 2nd edition published in 2014. Forty-two specialists in stroke rehabilitation from 21 universities and 4 rehabilitation hospitals and 4 consultants participated in this update. The purpose of this CPG is to provide optimum practical guidelines for stroke rehabilitation teams to make a decision when they manage stroke patients and ultimately, to help stroke patients obtain maximal functional recovery and return to the society. The recent two CPGs from Canada (2015) and USA (2016) and articles that were published following the 2nd edition were used to develop this 3rd edition of CPG for stroke rehabilitation in Korea. The chosen articles' level of evidence and grade of recommendation were decided by the criteria of Scotland (2010) and the formal consensus was derived by the nominal group technique. The levels of evidence range from 1++ to 4 and the grades of recommendation range from A to D. Good Practice Point was recommended as best practice based on the clinical experience of the guideline developmental group. The draft of the developed CPG was reviewed by the experts group in the public hearings and then revised. “Clinical Practice Guideline for Stroke Rehabilitation in Korea 2016” consists of ‘Chapter 1; Introduction of Stroke Rehabilitation’, ‘Chapter 2; Rehabilitation for Stroke Syndrome, ‘Chapter 3; Rehabilitation for Returning to the Society’, and ‘Chapter 4; Advanced Technique for Stroke Rehabilitation’. “Clinical Practice Guideline for Stroke Rehabilitation in Korea 2016” will provide direction and standardization for acute, subacute and chronic stroke rehabilitation in Korea.
Canada
;
Consensus
;
Consultants
;
Humans
;
Korea*
;
Practice Guidelines as Topic
;
Rehabilitation*
;
Scotland
;
Specialization
;
Stroke*