1.Missed posterior shoulder dislocation and McLaughlin lesion after an electrocution accident.
Fabio RODIA ; Angelo VENTURA ; Georgios TOULOUPAKIS ; Emmanouil THEODORAKIS ; Marco CERETTI
Chinese Journal of Traumatology 2012;15(6):376-378
Posterior shoulder dislocation is a rare event that may occur after a direct trauma, an epileptic seizure, electric shock or electroconvulsive therapy. In more than 50% of the cases, posterior dislocations are missed on initial evaluation and often misdiagnosed as frozen shoulders with unfortunate consequences. We present the case of a missed posterior subluxation and reverse Hill Sachs lesion (McLaughlin lesion) in a 40-year-old woman caused by anelectric shock of 240 V. The patient underwent surgery in our institute two weeks after the injury. The humeral head was reduced and the reverse Hill Sachs lesion was filled by demineralized bone matrix allograft with osteoinductive factors. Tendons were repaired and a temporaneous artrodesis was performed. At the final follow up of 12 months, we obtained a Costant Score of 93 and the patient returned to her previous daily activities.
Adult
;
Diagnostic Errors
;
Disability Evaluation
;
Electric Injuries
;
complications
;
diagnosis
;
surgery
;
Female
;
Humans
;
Shoulder Dislocation
;
diagnosis
;
etiology
;
surgery
2.A distal-lock electromagnetic targeting device for intramedullary nailing: Suggestions and clinical experience.
Guido ANTONINI ; Wilfried STUFLESSER ; Cornelio CRIPPA ; Georgios TOULOUPAKIS
Chinese Journal of Traumatology 2016;19(6):358-361
PURPOSETo describe our clinical experience with a system named SureShot? Distal Targeting (Smith & Nephew, Memphis, USA) based on magnetic field presence and discuss our suggestions on this technique.
METHODSWe analysed prospectively 47 patients affected by humeral, tibial or femoral fractures, treated in our institution during a 3-year period of time (August 2010 to September 2013). We considered the following parameters: the time to set up, the time to position a single screw, the effectiveness of the system (drilling ad screwing), the irradiation exposure time during distal locking procedure and surgical complications.
RESULTSA total number of 96 screws were inserted. The mean preparation time of the device was 5.1 min ± 2 min (range 3-10 min). The mean time for single screw targeting was 5.8 min ± 2.3 min (range 4-18 min). No major complications occurred. Only a few locking procedures were needed to be practiced in order to obtain the required expertise with this targeting device.
CONCLUSIONAccording to our results, this device is reliable and valid whenever the correct technique is followed. It is also user friendly, exposes to lower radiation and needs less surgical time compared to relative data from the literature. However, the surgeon should always be aware of how to use the free hand technique in case of malfunctioning of the system.
Bone Screws ; Fracture Fixation, Intramedullary ; adverse effects ; instrumentation ; methods ; Humans ; Magnetic Fields ; Prospective Studies
3.Fixation of complex proximal humeral fractures in elderly patients with a locking plate: A retrospective analysis of radiographic and clinical outcome and complications.
Fabio RODIA ; Emmanouil THEODORAKIS ; Georgios TOULOUPAKIS ; Angelo VENTURA
Chinese Journal of Traumatology 2016;19(3):156-159
PURPOSEThe optimal surgical treatment of displaced type B and C fractures of the proximal humerus in the elderly remains controversial. Good clinical results have been reported by plating these fractures as well as a high rate of complications. Our retrospective study aims to evaluate clinical recovery and complications using the S3 locking plate in elderly patients.
METHODSFifty-one patients older than 65 years of age, with a complex proximal humeral fracture type B or C (AO classification system), were included. Patients have been followed up for a minimum of 12 months. We assessed callus formation, radiological results, clinical outcome (according to the Constant Shoulder Score System) and complications. Any difference in the clinical recovery among the 2 types of fracture pattern (B and C) was investigated.
RESULTSThe mean time of fracture healing was 12.4 weeks. The mean Constant score at 3, 6 and 12 months was 68, 73 and 75 respectively. No statistically significant difference in the clinical outcome was observed between the B and C fracture patterns (p > 0.05). We noticed an overall of 5 complications (9.8%). There was no need to revision any of the implants.
CONCLUSIONAnatomic reduction and proper plate positioning are essential for minimizing implantrelated complications. In our experience the S3 angular stability system offers a proper osteosyntesis and a good clinical recovery with a low rate of complications.
Aged ; Aged, 80 and over ; Bone Plates ; Female ; Fracture Fixation, Internal ; adverse effects ; methods ; Fracture Healing ; Humans ; Male ; Middle Aged ; Retrospective Studies ; Shoulder Fractures ; diagnostic imaging ; surgery
4.A two-choice strategy through a medial tibial approach for the treatment of pilon fractures with posterior or anterior fragmentation.
Luigi Di GIORGIO ; Georgios TOULOUPAKIS ; Emmanouil THEODORAKIS ; Luca SODANO
Chinese Journal of Traumatology 2013;16(5):272-276
OBJECTIVEThe anterolateral approach to the tibia has been popularized for the management of tibial pilon fractures. For complex fracture patterns a combined anterolateral/anteromedial approach is suitable but a high rate of complication has been reported. In our retrospective study a two-choice strategy adopting a medial tibial approach was proposed for the treatment of pilon fractures with anterior or posterior fragmentation.
METHODSBased on an anatomic study of tibial pilon fractures, we retrospectively analyzed the fractures with primary posterior, posterior-lateral or anterior, anterior-lateral (Tillaux-Chaput) involvement of the distal tibia. This retrospective study consisted of 18 patients with a closed tibial plafond fracture. The inclusion criteria were: (1) pre- sence of an anterior/anterolateral type fragment or a posterior (Volkmann) type fragment involving larger than 25% of the articular surface, (2) a minimum follow-up of 12 months, (3) a fibula fracture associated with a medial column fracture of the distal tibia, and (4) soft tissue conditions at the time of operation that did not compromise the choice of surgical access (Tscherne classification for closed fractures: grade 0 and grade 1). Tibial plafond fractures were classified into two groups: one presenting anterior and the other with posterior rim (Volkmann) fragments.
RESULTSMost patients achieved a good clinical recovery in terms of range of motion and Olerud-Molander scale scores. Only three patients presented a grade 2 osteoarthritis at the 12 month follow-up.
CONCLUSIONOur two-choice strategy highlights concepts which have been previously debated and described in the literature. But a new extended protocol for surgical approach to the distal tibia, including more fracture patterns and their association should be further investigated.
Adult ; Female ; Fibula ; injuries ; Follow-Up Studies ; Fracture Fixation ; methods ; Humans ; Intraoperative Complications ; Male ; Middle Aged ; Retrospective Studies ; Tibia ; Tibial Fractures ; pathology ; surgery ; Treatment Outcome
5.Management of post-traumatic elbow instability after failed radial head excision: A case report.
Georgios TOULOUPAKIS ; Emmanouil THEODORAKIS ; Fabio FAVETTI ; Massimiliano NANNERINI
Chinese Journal of Traumatology 2017;20(1):59-62
Radial head excision has always been a safe commonly used surgical procedure with a satisfactory clinical outcome for isolated comminuted radial head fractures. However, diagnosis of elbow instability is still very challenging and often underestimated in routine orthopaedic evaluation. We present the case of a 21-years old female treated with excision after radial head fracture, resulting in elbow instability. The patient underwent revision surgery after four weeks. We believe that ligament reconstruction without radial head substitution is a safe alternative choice for Mason III radial head fractures accompanied by complex ligament lesions.
Adult
;
Elbow Joint
;
injuries
;
Female
;
Fracture Fixation
;
Humans
;
Joint Instability
;
therapy
;
Lateral Ligament, Ankle
;
surgery
;
Radius Fractures
;
complications
;
diagnostic imaging
;
surgery
;
Tomography, X-Ray Computed