1.Analysis of age-specific prostate specific antigen and related parameters in 22 055 elderly men
Gansheng XIE ; Yuhua HUANG ; Chunyin YAN ; Jinxian PU ; Gang LI ; Jun OUYANG ; Jianquan HOU
Chinese Journal of Urology 2013;34(8):613-617
[Abstract] Objective To define the age-specific normal reference values of prostate specific antigen (PSA) and related parameters in Chinese middle-aged and elderly men.Methods From April 2007 to November 2011,serum PSAs of over 22 055 men aged more than 40 years old in our medical examination center were statistically analyzed.The men was divided into five groups by a 10-year-old interval.Total PSA (tPSA),free PSA (fPSA) and prostate ultrasound results were recorded.The free-total PSA ratio (f/t),PSA density (PSAD) and PSA velocity (PSAV) were calculated.By convention,the 95th percentile (P95)was used as the upper limit value,and the 5th percentile (P5) as the lower limit value.Results The tPSAs were positively correlated with age (r=0.349,P<0.001).f/t was negatively correlated with age (r=-0.154,P<0.01).Although f/t was significantly different (P<0.001) among each age group,P5 of all groups were 0.18.PSAD was significantly different (P<0.001) between men over and under 70 years,with P95 as 0.09 and 0.15,respectively.PSAD had a positive correlation with age (r =0.263,P<0.01).The significant difference of PSAV raised between men over and under 60 years,with P95 as 0.21 and 0.58,respectively.PSAV was positively correlated with age (r=0.130,P<0.01).Conclusions PSA,PSAD and PSAV are positively correlated with age,while f/t is negatively correlated with age.The normal range of f/tis 0.18-1.00 for Chinese men over 40 years old.PSAD's normal ranges are <0.09 and <0.15 in Chinese men over and under 70 years,respectively.The normal range of PSAV are <0.21 and <0.58 for Chinese men over and under 60 years,respectively.
2.A Meta-analysis of quantitative evaluation of lumbar intervertebral disc degeneration by functional MRI T1ρ
Gansheng HE ; Congyang XUE ; Zhicheng WANG ; Lin XIE
Journal of Practical Radiology 2024;40(2):261-265,310
Objective To investigate the change rule of T1ρ value in the process of lumbar intervertebral disc degeneration(IVDD)based on Pfirrmann grading by Meta-analysis.Methods PubMed,EMBASE,Cochrane Library,CNKI,Wanfang Data,VIP and Sinomed were searched to collect studies on quantitative assessment of IVDD using T1ρ imaging technology.The retrieval time limit was from the establishment of the database to December 20,2022.Meta-analysis was performed using RevMan 5.4 and Stata 14.0 software.Results A total of 12 articles were included,and the numbers of Pfirrmann grade Ⅰ-Ⅴ lumbar discs were 316,1 460,769,430 and 98,respectively.T1ρ relaxation time decreased gradually with the increase of the grade of degeneration.The T1ρ values of grade Ⅰlumbar discs were significantly higher than those of grade Ⅱ lumbar discs[weighted mean difference(WMD)=14.55,95%confidence interval(CI)6.35-22.75,P<0.01],and the T1ρ values of grade Ⅱ lumbar discs were significantly higher than those of grade Ⅲlumbar discs(WMD=34.20,95%CI 27.05-41.34,P<0.01).The T1ρ values of grade Ⅲ lumbar discs were significantly higher than that of grade Ⅳ lumbar discs(WMD=22.94,95%CI 17.08-28.80,P<0.01).The T1ρ values of grade Ⅳ lumbar discs were significantly higher than that of grade Ⅴ lumbar discs(WMD=9.35,95%CI 6.81-11.89,P<0.01).Conclusion T1ρ imaging technology can objectively and quantitatively evaluate degeneration at different stages,especially sensitive to IVDD in the early and middle stages,which can provide imaging evidence for clinical diagnosis of early IVDD.