1.Protective effect of ecdysterone on rabbits chondrocytes that is injured by lipopolysaccharide
Gangtao WANG ; Xuhui ZHANG ; Weidong ZHANG ; Lei XIA
Tianjin Medical Journal 2015;(6):587-589,590
Objective To study the effect of ecdysterone (EDS) on rabbits chondrocytes that is injuried by lipopolysac?charide (LPS). Methods Aricular chondrocytes were isolated from rabbits and randomly divided into three groups:control group;chondrocytes with LPS induced injury (LPS group);injury chondrocytes treated with EDS (LPS+EDS group). The cell proliferation and cell apoptosis of chondrocytes were determined by MTT method and flow cytometry assay respectively. The mRNA and protein expression levels of inducible nitric oxide synthase (iNOS) were detected by RT-PCR and western blot. In addition, the content of NO and IL-1βwere measured by nitric acid reductase assay and enzyme-linked immunosorbent assay (ELISA) respectively. Results Attenuated proliferation, increased cell apoptosis, iNOS, NO and IL-1βwere seen in LPS group , but all these changes were significantly reversed by EDS treatment (P<0.05). Conclusion Ecdysterone exhib?ited a protective effect on LPS induced rabbits chondrocytes injury through inhibiting the expression of iNOS.
2.Levels of occupational external exposure of radiation workers in Hubei province from 2009 to 2018
Wenshan ZHOU ; Fang WANG ; Wenfeng YI ; Yajuan CHEN ; Gangtao SUN
Chinese Journal of Radiological Medicine and Protection 2021;41(2):122-127
Objective:To provide a retrospective analysis of the levels of occupational external exposure of radiation workers in Hubei province from 2009 to 2018 in a way to prevent and control its risks.Methods:The external individual doses were surveyed for 50 070 radiation workers between 2009 and 2018 by the effort of the Hubei Provincial Center for Disease Control and Prevention. Under the relevant national standards, the external radiation doses to radiation workers were conducted by using TLDs.Results:The average annual collective effective dose to radiation workers in a 10 years period was 1.93 man·Sv, the median of average annual effective dose of 0.14 mSv ( P25- P75: 0.06-0.30 mSv), and the average annual effective dose of 0.40 mSv. The annual effective doses received by 46 562 workers were less than 1 mSv, accounting for 92.99% of the total monitored workers. The annual effective dose varied dependent on occupational categories, showing a year-by-year decline trend and staying at a low level after 2012. The relative high radiation doses were seen in nuclear medicine and interventional radiology in medical applications, non-destructive testing and well logging in industrial applications, and other types of radiation applications. Conclusions:The average annual effective dose decreased year in a by year manner and kept at a low level. This indicated that the radiological protection measures taken during the 10 years ensure the health of workers. The continuous monitoring result suggest that much more attention should be paid to such categories workers as nuclear medicine, interventional radiology, non-destructive testing, well logging and others through improving radiation protection measures.
3.Measurement of thyroid 131I activity in 162 iodine treatment workers in Hubei Province, China
Gangtao SUN ; Fang WANG ; Jianfeng ZHANG ; Xiaoliang LI ; Hezheng ZHAI ; Wenshan ZHOU
Chinese Journal of Radiological Health 2023;32(3):264-269
Objective To determine the current status of occupational internal exposure to 131I in the thyroid of nuclear medicine workers, to explore the influencing factors for internal exposure, and to provide a basis for the radiation safety management of nuclear medicine. Methods The cluster sampling method was used to select 162 workers practicing 131I treatment in 24 hospitals in Hubei Province, China. Thyroid 131I activity levels were measured in vitro using a portable γ-spectrometer, and the committed effective dose was estimated. Results The thyroid 131I activity detected in 13 (54.17%) hospitals was above the lower limit of detection of the instrument. Two hospitals had the highest detection rates, 62.50% and 61.90%; the difference was significant compared with the remaining 11 hospitals (P < 0.0001). Thyroid 131I was detected in 34 workers in total, with a detection rate of 20.99% and a mean activity of 179.09 ± 138.71 (6.02-589.74) Bq. The highest detection rates were found in cleaners and nurses, which were 35.71% and 33.33%, respectively, with no significant difference in detection rate between positions (least P > 0.08). The mean value of the committed effective dose was 0.68 ± 0.52 (0.02-2.22) mSv/a in the 34 workers. Conclusion The 131I consumption and workplace ventilation may be important factors affecting the level of internal exposure. It is important to strengthen the training of nuclear medicine workers on radioprotection and workflow management, as well as the regular monitoring of occupational internal exposure for 131I treatment-related workers.
4.Quality control analysis of test items based on Philips Digital Diagnost DR
Zhixin ZHAO ; Gangtao SUN ; Zipo ZHAI ; Qiang WANG ; Haihua WANG ; Bo ZHU ; Qian QIAN ; Yong YANG ; Hezheng ZHAI
Chinese Journal of Radiological Health 2022;31(5):553-557
Objective To explore the quality control results of Digital Diagnost digital radiography (DR), and also to analyze the differences in signal transfer characteristics (STP) of DR from different manufacturers, in order to provide a reference for quality control of testers and daily supervision of administrative staff. Methods According to WS 76—2020 “Specification for testing of quality control in medical X-ray diagnostic equipment”, the test items such as automatic exposure control (AEC) repeatability, AEC response, detector dose indication (DDI), STP, high-contrast resolution, and low-contrast resolution of Digital Diagnost DR were qualitatively controlled, and several common DRs on the market were selected to analyze their STP functional relationships. Results The baseline values of DDI, high-contrast resolution, and low-contrast resolution of Digital Diagnost DR were 19733, 2.8 Lp/mm, and H5 of image central pixel value, respectively; the quality control results of other test items met the requirements of WS 76—2020. The STP functional relationships of common DRs were mainly linear and logarithmic, but different models of DR from the same manufacturer might also have different STP functional relationships. Conclusion When testing some special test items of DR, attention should be paid to the influence of a variety of factors, while refining the test steps and condition settings for the test items. The simulation should be performed in accordance with the functional relationship provided by the manufacturer when analyzing the STP.
5.Synergistic immunoreaction of acupuncture-like dissolving microneedles containing thymopentin at acupoints in immune-suppressed rats.
Qian ZHANG ; Chuncao XU ; Shiqi LIN ; Huanbin ZHOU ; Gangtao YAO ; Hu LIU ; Lili WANG ; Xin PAN ; Guilan QUAN ; Chuanbin WU
Acta Pharmaceutica Sinica B 2018;8(3):449-457
Dissolving microneedles carried drug molecules can effectively penetrate the stratum corneum of skin to improve the transdermal drug delivery. The traditional Chinese medicine acupuncture is based on the needle stimulation at a specific location (acupoint) to generate and transmit biochemical and physiological signals which alter the pathophysiological state of patients. However, the pain associated with conventional acupuncture needles and the requirement of highly trained professionals limit the development of acupuncture in non-Asian countries. The purpose of this study is to investigate whether the dissolving microneedles can be utilized as a self-administered painless replacement for acupuncture and locally released drug molecules can achieve expected therapeutic outcomes. Immunosuppressive rats were treated with acupuncture at Zusanli (ST36) acupoint using microneedles containing thymopentin. The immune functions and psychological mood of the immunosuppressed animals were examined. The proliferation of splenocytes was examined by CCK-8 assay. CD4 and CD8 expression patterns in spleen cells were detected by flow cytometry. The current study showed that use of either microneedles containing thymopentin or conventional acupuncture both resulted in immune cell proliferation, which was confirmed by flow cytometry. Furthermore, either conventional acupuncture or microneedles were able to effectively mitigate the anxiety caused by immune-suppression when applied on the ST36.