1.The effect of interventional treatment on the expression of drug-resistance gene in primary lung carcinomas
Gang SUN ; Peng JIN ; Zonggui XIE ; Ming GENG ; Yuhai YI
Chinese Journal of Radiology 2001;0(09):-
Objective To study the effect of interventional treatment on the expression of PgP and GST ? in different histopathological types of primary lung carcinoma. Methods One hundred and eighteen cases of histopathologically verified primary lung carcinoma were studied. SCLC was found in 26 cases and NSCLC in 92 cases. The non chemotherapy group had 50 cases, and the interventional treatment group had 68 cases. PgP and GST ? were examined in all specimens with 2 step immunohistochemistry. Results The positive expression rates of PgP and GST ? were 32.0% and 34.0% in non chemotherapy group, respectively, 75.0% and 78.6% in interventional treatment with non embolization group, respectively, and 50.0% and 52.5% in interventional treatment with embolization group, respectively. The positive expression rates of PgP and GST ? had significant difference between non chemotherapy group and interventional treatment with non embolization group( P 0.05). There was a tendency of positive correlation between differentiated degree of carcinoma and the expression of PgP and GST ? in NSCLC. Condusion To detect PgP and GST ? in carcinoma tissue is important and has the instructive significance for chemotherapy of lung carcinoma. The positive rate of multidrug resistant gene is obviously increased in the primary lung carcinoma with bronchial arterial chemotherapy. The inducement to multidrug resistance gene in bronchial arterial embolization with the emulsifying agent of oil anticarcinogen was lower.
2.Outcomes of T3a Prostate Cancer with Unfavorable Prognostic Factors Treated with Brachytherapy Combined with External Radiotherapy and Hormone Therapy.
Zhi-peng MAI ; Wei-gang YAN ; Han-zhong LI ; Yi ZHOU ; Zhi-en ZHOU
Chinese Medical Sciences Journal 2015;30(3):143-149
OBJECTIVETo evaluate the outcomes of T3a prostate cancer with unfavorable prognostic factors treated with permanent interstitial brachytherapy combined with external radiotherapy and hormone therapy.
METHODSFrom January 2003 to December 2008, 38 patients classified as T3a prostate cancer with unfavorable prognostic factors were treated with trimodality therapy (brachytherapy + external radiotherapy + hormone therapy). The prescription dose of brachytherapy and external radiotherapy were 110 Gy and 45 Gy, respectively. The duration of hormone therapy was 2-3 years. The endpoints of this study included biochemical failure-free survival (BFFS), distant metastasis-free survival (DMFS), cancer-specific survival (CSS), and overall survival (OS). Survival curves were calculated using the Kaplan-Meier method. The Log-rank test was used to identify the prognostic predictors for univariate analysis.
RESULTSThe median follow-up was 71 months. The serum pre-treatment prostate-specific antigen (PSA) level ranged from 10.0 to 99.8 ng/ml (mean 56.3 ng/ml), the Gleason score ranged from 5 to 9 (median 8), and the percentage of positive biopsy cores ranged from 10% to 100% (mean 65%). The 5-year BFFS, DMFS, CSS, and OS rates were 44%, 69%, 82%, and 76%, respectively. All biochemical failures occurred within 40 months. The percentage of positive biopsy cores was significantly correlated with BFFS, DMFS, and OS (all P=0.000), and the Gleason score with DMFS (P=0.000) and OS (P=0.001).
CONCLUSIONST3a prostate cancer with unfavorable prognostic factors presents not so optimistic outcome. Hormone therapy should be applied to prolong the biochemical progression-free or metastasis-free survival. The percentage of positive biopsy cores and the Gleason score are significant prognostic factors.
Androgen Antagonists ; therapeutic use ; Brachytherapy ; Combined Modality Therapy ; Gonadotropin-Releasing Hormone ; agonists ; Humans ; Male ; Neoplasm Grading ; Prognosis ; Prostatic Neoplasms ; mortality ; pathology ; therapy ; Treatment Outcome
3.An experimental study of percutaneous vertebroplasty using instruments and drugs made in China
Gang SUN ; Yongjian CONG ; Peng JIN ; Zonggui XIE ; Yuhai YI ; Xuping ZHANG ;
Chinese Journal of Radiology 2001;0(03):-
Objective To evaluate the efficacy of percutaneous vertebroplasty(PVP) using instruments and drugs made in China, and to provide the data for the clinical application Methods Polymethylmethacrylate(PMMA) without adding contrast was classified into 3 groups according to the ratio of powder/liquid as 2∶1,3∶2,1∶1,PMMA with contrast was also classified into 3 groups according to the ratio of powder/liquid/contrast as 2∶1∶1,3∶2∶1,1∶1∶1 There were 6 groups totally The periods and temperature of polymerizing process were measured The PMMA specimens of different group were made,with the diameter of 1 0 cm, height of 3 0 cm The density was determined in X ray pictures and mechanical testing with universal testing machine was performed PVPwas performed in the spines of 3 human cadavers with transpedicular route under fluoroscopic control The PMMA was injected into vertebra at an interval of one vertebra from T4-L4, 7 vertebra were injected on each cadaver The injected volume was recorded The spines were dissected into 42 single vertebrae, with all soft tissues removed Overall,21 pairs of adjacent vertebrae were subjected to axial compression in an universal testing machine The cranial vertebra of each pair was injected with PMMA, the caudal one served as a control Results Lower temperature was observed in the PMMA groups with adding contrast than those without adding contrast during the polymerizing process, the average temperature in the PMMA group with the ratio of powder/liquid/contrast as 3∶2∶1 was 67 4℃ There was significant X ray density difference between the groups with contrast and corresponding groups without contrast ( t = 20 00, t = 20 00, t = 22 86, P 0 05) The group with ratio of power/liquid/contrast 3∶2∶1 was (127? 4 70) s in the period of the paste, and the ultimate compressive strength (mPa) was 47 23 The punctures were successfully reached in all vertebra The injected PMMA average volume was 5 ml in the thoracic vertebra and 7 5 ml in the lumbar vertebra PMMA leaking into adjacent paravertebral tissue was demonstrated in 3 of 21 vertebrae The ultimate compressive strength of the vertebrae without PMMA injection in the 3 groups was 3 28,3 63,and 3 69, respectively The ultimate compressive strength of the injected PMMA vertebrae in the 3 groups was 4 52,4 73,and 4 81, respectively The ultimate compressive strength was significantly higher in the injected PMMA vertebrae than that in the vertebrae without PMMA injection( t =3 17,3 55,3 99, P
4.Percutaneous vertebroplasty for treatment of metastatic tumor in axis
Gang SUN ; Peng JIN ; Yuhai YI ; Xunwei LIU ; Fandong LI ; Zhiyong XIE ; Xuping ZHANG ; Min LI
Chinese Journal of Radiology 2010;44(4):421-423
Objective To explore the safety and effectiveness of percutaneous vertebrophasty(PVP)in the treatment of the metastatic tumor involved axis.Methods Ten patients(8 male,2 female)with osteolytic metastases involved axis were treated with PVPs.The anterolateral approach with fluoroscopy guidance was selected in 9 cases,while the posterolateral approach with CT guidance was selected in 1 case.Results Successful unilateral-paracentesis for PVP were achieved in all patients without intervention related complications such as bleeding and symptomatic polymethylmethacrylate(PMMA)leakage.CT scan taken following PVP showed that over 70% of the osteolytic metastatic area was well filled with PMMA in all cases.Varying degrees of pain relief were observed(CR in 7 cases,PR in 3 cases)within 7 days.All patients could support their heads without brackets.During a 3 to 24 months follow up after the procedures,No aggravated pain was found in the group.Two patients died in 4 months,3 Patients died in 8 to 11 months 4 patients died in 13 to 15 months,and 1 patient still was alive after 24 months.Conclusion Anterolateral or posterolateral approach to Aixs in PVP is safe and effective in treating osteolytic metastatic tumors.
5.The preliminary study on a single balloon cross-medline expansion using unipedicular approach in kyphoplasty
Gang SUN ; Peng JIN ; Xunwei LIU ; Runsong HAO ; Zhiyong XIE ; Fandong LI ; Yuhai YI ; Xuping ZHANG
Chinese Journal of Radiology 2008;42(5):519-522
Objective To evaluate the clinical efficacy and safety of kyphoplasty with single balloon cross-midline expansion using unipedicular approach for osteoporotic vertebral body compressive fracture (OVCF).Methods Thirty six cases of painful OVCF were included in the study,with 61 vertebrae involved.Under X-ray fluoroscopy monitoring,kyphoplasty was performed using a unilateral,single,balloon via a unilateral transpedicular approach.A final balloon position was in the midline of the vertebral body with the balloon cross-midline expansions and bone cement filled. Clinical outcomes were determined by comparison of preoperative and postoperative VAS and ODI scores.Radiographic assessment included vertebral height restoration and correction of kyphosis.Follow-up was conducted for 6.0-12.0 months(mean 9.2 months).Results Thirty-six consecutive patients with 61 vertebrae were successfully operated with an operative time of(37.4±9.6)rain per vertebra.All patients had significant pain relief and functional recovery within 96 h after the procedure with no surgery-and device-related complications.VAS score improved from(7.3±1.0)preoperatively to(2.7±0.8)postoperatively(t=19.53,P<0.01).ODI score was decreased from(71.1±10.9)%preoperatively to(26.6±6.4)%postoperatively(t=18.54,P<0.01).The average anterior body height loss was(14.3±2.8)mm before procedure and(10.0±1.8)mm after procedure(t=14.68,P<0.01).The average middle body height loss was(10.2±2.7)mm before procedure and(5.9±1.8)mm after procedure(t=16.44,P<0.01).The Cobb's angle was corrected from 23.4°±5.0° to 16.2°±2.8°(t=15.60,P<0.01).Some leakages of cement around the anterior margin of vertebra and inter-vertebral space were found in 2 patients,but there were no clinical symptoms.X-ray examination indicated there were no cement leakages in other vertebra.The pain relief and functional recovery were substantial and maintained to the last follow up without any re-collapse or adjacent level fracture.Conclusions A single-balloon cross-midline expansion using unipedicular approach in kyphoplasty for OVCF is effective and safety,less operation time,less radiation exposure compared to the conventional kyphoplasty technique.
6.Treatment of mandibular fractures with the tramsbical trochar instrumentation
Yi YANG ; Guicun PENG ; Haibo LIU ; Gang LIU ; Ping LI ; Yake LIU
Chinese Medical Equipment Journal 1989;0(01):-
Objective To observe the treatment effect of using screwed miniplates through an intraoral and transoral approach for patients with angle and ramus fractures. Methods 21 cases of mandibular angle and ramus fractures were treated by screwed miniplates placed through an intraoral incision with transbuccal mini-incision. Results The use of intraoral and transoral approach reduced the rate of facial paralysis and scar in the internal fixation operation. No postoperative infection occurred in all the cases. Conclusion The use of rigid internal fixation through an intraoral and transoral approach can be applied in the patients with angle and ramus fractures.
7.A Novel Multi-funtional Tool for Breaking off Ampoule Bottles
Fei HE ; Yi YANG ; Hongyan JIA ; Yake LIU ; Gang LIU ; Yizhuo PENG
Chinese Medical Equipment Journal 2004;0(09):-
Objective To produce a novel tool for breaking off the ampoule bottles,which can protect the nurses from wounding their fingers by the glass fragment so as to guarantee the safety for the nurses. Methods We design a mould with the self curing plastic and leave some space in the end to insert the ampoule bottle,then fix the bistrique and spring to break off the bottles. Results This tool can break off several kinds of ampoule bottles with any bottles cracked and has achieved good clinical effect. Conclusion This mulfunctional tool is scientificly designed,easy to make,and it is very helpful for the medical staff in protection and enhancing working efficiency,so it is very valuable to be popularized in hospitals.
8.The primary report of percutaneous polymethyl methacrylate cementoplasty in osteolytic metastases of the pelvis and peripheral bone
Gang SUN ; Peng JIN ; Yuhai YI ; Zhiyong XIE ; Xuping ZHANG ; Guoying LI
Chinese Journal of Radiology 2001;0(08):-
Objective To propose a technique and treatment of percutaneous polymethyl methacrylate(PMMA) cementoplasty for painful metastatic lesions of the pelvis, humerus, and tibia. Methods Percutaneous PMMA cementoplasty was performed in 24 cases, including the lesions of S1 in 9 cases, acetabulum in 7 cases, ischium in 5 cases, humerus in 2 cases, and tibia in 1 case. There were 26 local lesions. The puncture approach was performed under fluoroscopic guidance. The S1 vertebral body puncture was performed with lateral transsacroiliac joint approach. The needle progression was controlled in the anteroposterior projection with a needle course above the level of the S1 foramen. With the needle adjacent to the S1 vertebral body edge, the needle tip should center just in front of the spinal canal in the lateral fluoroscopic projection. The acetabular roof puncture was performed with lateral approach. The needle progression was controlled in the anteroposterior and lateral projections alternately with a needle course parallel to the body axial plane. The puncture needle arrived directly at the lesions. The puncture to the ischium was from ischium tubercle to the lesions. The puncture progression to the internal compartment of the acetabulum was with the trajectory of the needle from the ischium tubercle to the lesion. The puncture progression to the humerus should avoid conflicting with the radial nerve and upper extremity vessels. The needle course should be from the dorsal upper arm to the lesions. As for the lesions of the tibia, the needle was punctured from the front of tibia to the lesion. After the needle tip placement in the lesions, PMMA in paste condition was injected with the precession injector pressure device under continuous visual control with adequate filling and avoidance of important PMMA leakage. Results Partial or complete pain relief was obtained in all 24 patients (CR in 10 cases, PR in 14 cases) within 7 days after the operation. Clinical improvement was maintained in 23 patients at the follow-up of 2-7 months. One patient with lesion of humerus re-experienced severe pain in local area of PMMA injection 27 days after the operation when he got up by using the treated arm for the support of the body weight. The condition was considered as the fracture at the cement-bone interface, and the gradual pain relief was obtained in 2 days with the external fixation of plaster for limiting the motion of the treated arm, and the complete relief maintained. There was PMMA leakage in 2 cases without corresponding clinical importance. Conclusion The technique and treatment of percutaneous PMMA cementoplasty in osteolytic metastases of the pelvis and peripheral bone was safe and effective. Considering the incidence of the potential fracture, the external fixation for motion limitation should be given after PMMA injection to extremity lesions.
9.Kyphoplasty with single balloon inflation followed by cement filling for osteoporotic vertebral compression fractures
Gang SUN ; Peng JIN ; Xunwei LIU ; Zhiyong XIE ; Fandong LI ; Yuhai YI ; Xuping ZHANG ; Runsong HAO
Chinese Journal of Tissue Engineering Research 2008;12(6):1179-1183
BACKGROUND: In kyphoplasty procedure, two balloons are inserted into the vertebral body and inflated simultaneously for height symmetric restoration of the vertebral body. However, the expensive cost of balloon of kyphoplasty limits the extensive development of this procedure in developing countries. In this study, we try to inflate single balloon with bilateral transpedicular routes alternatively to achieve vertebral body height balanced restoration and reduce operation expenditure. But biocompatibility of bone cement and effect of kyphoplasty still need further observation.OBJECTIVE: To investigate the biocompatibility of bone cement and the clinical efficacy of bipedicular kyphoplasty for osteoporotic vertebral compression fractures by inserting single inflatable balloon into injured vertebral body and filling bone cement in the cavity caused by inflating balloon via bipedicular approach.DESIGN: Controlled observation.SETTING: Department of Medical Imaging, General Hospital of Jinan Military Area Command of Chinese PLA.PARTICIPANTS: Twenty-two patients (31 vertebral bodies) undergoing kyphoplasty with single balloon in Department of Medical Imaging, General Hospital of Ji'nan Military Area Command of Chinese PLA from May 2004 to May 2005 were selected, including 5 males and 17 females aged 68-85 years. Patients with painful compression fractures caused by osteoporosis were enrolled, and confirmed by CT and MRI with complete vertebral posterior wall but no spine deformity. The informed consent was obtained from all subjects, and the experiment and treatment were approved by Ethics Committee. METHODS: The especial instrument for kyphoplasty including puncturing device and balloon were provided by Shandong Guanlong Medical Utensils Co., Ltd. [LDAI (T) 2004 No. 2150017]; bone cement (Polymethymethacrylate) was made in China [MAIT 2005(T) No. 3650267]. Under X-ray fluoroscopy monitoring, single inflatable balloon was inserted into fractured vertebral body by puncturing needle and inflated via bipedicular approach to restore vertebral height. MAIN OUTCOME MEASURES: ①Bone cement biocompatibility during and after surgery; ②pain relief within 72 hours after surgery, restoration of vertebral height and correction of kyphotic deformity.RESULTS: ①Bone cement biocompatibility: Little cement leakage was observed at one intervertebral space of one patient by X-ray film, but no clinical symptoms, inflammatory reaction or rejection were found. ②Obvious pain relief was found in 22 cases with within 72 hours after kyphoplasty. ③The height loss of the anterior and middle vertebral body reduced from (14.70±4.21) mm and (10.62±4.11) mm preoperatively to (10.38±4.23) mm and (6.45±4.04) mm postoperatively after single balloon inflation and cement filling. Cobb angle was corrected averagely from (21.15±6.33)° preoperatively to (11.64±4.33)° postoperatively. CONCLUSION:Biocompatibility of bone cement is good, and no specific adverse effects are found in despite of cement leakage. Bipedicular kyphoplasty with single balloon for painful osteoporotic vertebral compression fractures effectively restores vertebral heights and relieves pain.
10.Study on the prognosis of patients with acute paraquat intoxication.
Peng LIU ; Yue-zhong HE ; Hao-chun WANG ; Guang LI ; Cheng-gang ZHANG ; Xi-gang ZHANG ; Qing-yi MENG
Chinese Journal of Industrial Hygiene and Occupational Diseases 2011;29(3):212-215
OBJECTIVETo study the correlation factors of acute paraquat intoxication prognosis.
METHODSThe early paraquat concentration in plasma and urine, leukocyte count, hepatic and renal function, amylase, electrolyte and the parameters of arterial blood gas were analyzed retrospectively in 111 patients with acute paraquat intoxication.
RESULTS43 cases (38.7%) of all the 111 patients survived and the other 68 cases (61.3%) died. The patient, whose paraquat concentration was not more than 8.0 µg/ml in plasma and 276.0 µg/ml in urine, could survive. But some patients could die, only if there was no paraquat found in plasma. The paraquat levels in plasma and urine were significantly lower in survivors [(0.82 ± 1.70), (28.12 ± 51.17) µg/ml] than in nonsurvivors [(9.32 ± 12.04), (384.53 ± 597.93) µg/ml, respectively] (P < 0.01). The levels of leukocyte count, serum creatinine, aspartate aminotransferase (AST), and amylase were significantly higher in nonsurvivors than in survivors (P < 0.05, P < 0.01). In addition, metabolic acidosis was easier to appear in nonsurvivors. The multiple logistic regression analysis indicated that the paraquat concentration in plasma and urine, leukocyte count, creatinine and base excess were all related to survival.
CONCLUSIONThe higher paraquat concentration in plasma and urine, leucocytosis, renal dysfunction and metabolic acidosis are all important factors for the prognosis of paraquat intoxication.
Acidosis ; Adolescent ; Adult ; Aged ; Female ; Humans ; Kidney Diseases ; Leukocytosis ; Male ; Middle Aged ; Paraquat ; blood ; poisoning ; urine ; Prognosis ; Retrospective Studies ; Young Adult