1.Evaluation of marginal adaptation in three-unit frameworks fabricated with conventional and powder-free digital impression techniques
Hasan KOCAAĞAOĞLU ; Haydar ALBAYRAK ; Sezgi CINEL SAHIN ; Ayşegül Güleryüz GÜRBULAK
The Journal of Advanced Prosthodontics 2019;11(5):262-270
PURPOSE: The purpose of this in vitro study was to evaluate the marginal misfits of three-unit frameworks fabricated with conventional and digital impressions techniques. MATERIALS AND METHODS: Thirty brass canine and second premolar abutment preparations were fabricated by using a computer numerical control machine and were randomly divided into 3 groups (n=10) as follows: conventional impression group (Group Ci), Cerec Omnicam (Group Cdi), and 3shape TRIOS-3 (Group Tdi) digital impression groups. The laser-sintered metal frameworks were designed and fabricated with conventional and digital impressions. The marginal adaptation was assessed with a stereomicroscope at ×30 magnification. The data were analyzed with 1-way analysis of variances (ANOVAs) and the independent simple t tests. RESULTS: A statistically significant difference was found between the frameworks fabricated by conventional methods and those fabricated by digital impression methods. Multiple comparison results revealed that the frameworks in Group Ci (average, 98.8 ± 16.43 µm; canine, 93.59 ± 16.82 µm; premolar, 104.10 ± 15.02 µm) had larger marginal misfit values than those in Group Cdi (average, 63.78 ± 14.05 µm; canine, 62.73 ± 13.71 µm; premolar, 64.84 ± 15.06 µm) and Group Tdi (average, 65.14 ± 18.05 µm; canine, 70.64 ± 19.02 µm; premolar, 59.64 ± 16.10 µm) (P=.000 for average; P=.001 for canine; P<.001 for premolar). No statistical difference was found between the marginal misfits of canine and premolar abutment teeth within the same groups (P>.05). CONCLUSION: The three-unit frameworks fabricated with digital impression techniques showed better marginal fit compared to conventional impression techniques. All marginal misfit values were clinically acceptable.
Bicuspid
;
In Vitro Techniques
;
Tooth
2.The effect of thermo-mechanical fatigue on the retentive force and dimensional changes in polyetheretherketone clasps with different thickness and undercut
Güleryüz AYŞEGÜL ; Korkmaz CUMHUR ; Şener AYŞE ; Ozan Taş MEHMET
The Journal of Advanced Prosthodontics 2021;13(5):304-315
PURPOSE:
Esthetic expectations have increased the use of polyetheretherketone (PEEK) clasps as alternatives to Cr-Co in removable partial dentures (RPDs). The objective of this study was to evaluate the retentive force and dimensional change of clasps with different thickness and undercut made from PEEK by the thermo-mechanical fatigue.
MATERIALS AND METHODS:
PEEK clasps (N = 48) with thicknesses of 1 or 1.50 mm and 48 premolar monolithic zirconia crowns with undercuts of 0.25 mm or 0.50 mm were fabricated. Samples are divided into four groups (C1-C4) and were subjected to 7200 thermal aging cycles (at 5 - 55℃). The changes in the retentive force and dimensions of the clasps were measured by micro-stress testing and micro-CT devices from five measurement points (M1 - M5). One-way ANOVA, paired t-test, two-way repeated ANOVA, and post-hoc tests were used to analyze the data (P < .05).
RESULTS:
The retentive forces of C1, C2, C3, and C4 groups in initial and final test were found to be 4.389-3.388 N, 4.67 - 3.396 N, 5.161 - 4.096 N, 5.459 - 4.141 N, respectively. The effects of retentive force of all PEEK clasps groups were significant decreased. Thermo-mechanical cycles caused significant dimensional changes at points with M2, M4, and M5, and abraded the clasp corners and increased the distance between the ends of the clasp, resulting in reduced retentive forces (P* = .016, P* = .042, P < .001, respectively).
CONCLUSION
Thermo-mechanical aging decreases the retentive forces in PEEK clasps. Increasing the thickness and undercut amount of clasps decreases the amount of dimensional change. The values measured after aging are within the clinically acceptable limits.