1.Application of Plasma Sterilization System in Operating Room
Qiuqiu LIU ; Si LI ; Fujuan XIE
Chinese Journal of Nosocomiology 2006;0(03):-
OBJECTIVE To evaluate the efficacy of plasma sterilization system,observe and comprehend the(methods) and mechanisms of plasma sterilization.METHODS In application of plasma(sterilization) system,the(sterilization) processes were observed.The efficacy of this new system was shown by a biological test and chemical test.Comparative observation was conducted on the effective use time of wire of high-frequency electrode that had been sterilized in plasma sterilization system and Formalin smoke respectively.RESULTS The instrument that had been sterilized in plasma sterilization system all passed the tests and could be used immediately,manipulation of(plasma)(sterilization) system was easy,the effective use times of electrode′s wire were extended.CONCLUSIONS Plasma sterilization system can achieve effective sterilization with low(humidity),and no-toxicity.With shorter sterilization cycle time and lesser damage to surgery instruments,this new system improves the margin of safety and reduces(processing) costs.
2.Inhibiting effect of retinal Sigma-1 receptor antagonist on the form deprivation myopia in guinea pigs and its mechanism
Yuanyuan CHEN ; Fujuan XIE ; Haibo LI ; Yuxin GUAN ; Junfeng MAO
Chinese Journal of Experimental Ophthalmology 2021;39(6):477-482
Objective:To investigate the role and mechanism of retinal Sigma-1 receptor antagonist N, N-diethyl-2-[4-methoxy-3-(2-phenylethoxy)phenyl]ethanaminehydrochloride (NE-100) in the formation of form deprivation myopia (FDM) in guinea pigs.Methods:Eighty-five 21-day-old guinea pigs were selected, and 36 of them were randomly divided into normal control group, occluded 14-day group and occluded 11-day group, with 12 in each group.The right eyes of guinea pigs in the occluded 14-day group were covered with translucent eye shield for consecutive 14 days, and guinea pigs in the occluded 11-day group were treated in the same way for consecutive 11 days plus 3 days without cover, and guinea pigs in the normal control group were not covered.The other 49 guinea pigs were randomly divided into FDM group ( n=10), FDM+ NE-100 6 μg group ( n=12), FDM+ NE-100 60 μg group ( n=10), FDM+ NE-100 600 μg group ( n=9), and FDM+ saline group ( n=8). The right eyes in each group received 100 μl peribulbar injection of NE-100 6 μg, 60 μg and 600 μg or saline once a day according to grouping.Ocular refraction and axial dimensions were measured using eccentric infrared photorefractor and A-scan ultrasonography, respectively.Corneal curvature was measured with keratometer.Immunohistochemical staining and Western blot were used to detect the expression levels of Sigma-1 receptor protein, and retinal dopamine content was evaluated by high-performance liquid chromatography with electrochemical detection.This study was approved by an Ethics Committee of the Department of Laboratory Animal Science of Central South University (No.2020sydw0084). The use and care of experimental animals followed the Regulations for the Administration of Affairs Concerning Experimental Animals in China. Results:There were statistical significant differences in diopter and axial length among the normal control group, occluded 14-day group and occluded 11-day group ( F=147.81, 160.10; both at P<0.01). Compared with the normal control group, the relative myopia was the deepest and the axial length was the longest in the occluded 14-day group, then the occluded 11-day group, showing significant differences between them (all at P<0.05). In the normal control group, Sigma-1 protein was mainly expressed in retinal ganglion cells (RGCs), photoreceptor inner segment and the inner nuclear layer.In the occluded 14-day group, Sigma-1 protein staining was enhanced in RGCs and photoreceptor inner segment.Sigma-1 staining positive cells in the inner nuclear layer were increased significantly and were also seen in the inner and outer plexiform layers, especially in Müller cells, in which the expression levels of Sigma-1 receptor protein were significantly increased.Compared with the occluded 14-day group, the Sigma-1 receptor protein expression levels in the retina of the occluded 11-day group was significantly decreased ( P<0.01). The diopters of guinea pigs in the FDM+ NE-100 6 μg, 60 μg and 600 μg groups were lower than those in the FDM group, and the diopters of FDM+ NE-100 60 μg and 600 μg guinea pigs were lower than those in the FDM+ NE-100 6 μg group, and the differences were statistically significant (all at P<0.05). The dopamine content in the retina of the FDM+ NE-100 60 μg group was (0.74±0.09) ng/mg, which was significantly higher than (0.57±0.10) ng/mg in the FDM group, with a significant difference between them ( t=15.18, P<0.01). Conclusions:Sigma-1 receptor antagonist inhibits FDM formation, which may be associated with the elevation of dopamine content in retina.
3.Application of personalized lateral decubitus pillow for patients with cervical spine surgery
Chunlan? GONG ; Guoying WEN ; Cuiyan LONG ; Xinqian XIE ; Guanyi FANG ; Fujuan ZHOU
Chinese Journal of Modern Nursing 2015;21(5):599-601
Objective To explore the application effect of personalized lateral decubitus pillow for patients with cervical spine surgery. Methods A totals of 106 patients after cervical spine surgery were recruited and randomly divided into control group (48 cases) and experimental group (58 cases). Patients in the control group used the common pillow when patients lay lateral position-the height of pillow equal to shoulder cheekbone breadth, while experimental group used the personalized lateral decubitus pillow which supported suspended occipitalis and the height of pillow adjusted by individual. The comfort score, incision pain score and last time for lateral position of all patients were compared. Results The comfort score of the experimental group was significantly higher than that of the control group during the first day, second day and the third day after surgery [(66. 3 ± 4. 8) vs (63. 4 ± 3. 5), (68. 4 ± 5. 3) vs (65. 1 ± 4. 6), (71. 3 ± 4. 8) vs (68. 3 ± 4. 4);t=3. 461,3. 473,3. 270, respectively; P <0. 05]. The incision pain score of the experimental group was significantly lower than that of the control group during the first day, second day and the third day after surgery [(5.09±1.33) vs(5.88±1.29),(4.78±1.30) vs(5.52±1.09),(4.33±1.13) vs(5.06±1.06);t=3. 127,3. 157,3. 427, respectively;P<0. 05]. The last time of the experimental group for lateral position were longer than that of control group [(88. 6 ± 15. 2) min vs (79. 3 ± 14. 1) min; t = -3. 239,P =0. 002]. Conclusions It can increase the comfort score, extend the last time for lateral position and lessen incision pain to use the individuation lateral position pillow for patients after cervical spine surgery.
4.Bibliometric analysis of perioperative venous thromboembolism prevention based on Web of Science
Huimin GAO ; Xiuwen CHEN ; Jiqun HE ; Fujuan XIE ; Yinhua LIANG
Chinese Journal of Modern Nursing 2024;30(8):997-1003
Objective:To analyze the status quo and hot topics in research on venous thromboembolism (VTE) prevention during the perioperative period and provide references for future research and clinical practice.Methods:Journal articles related to perioperative VTE prevention were retrieved from the Web of Science Core Collection database up to June 30, 2023. Bibliometric analysis was conducted using CiteSpace 6.2.R4.Results:A total of 1 079 articles were included, showing an overall upward trend in the publication volume of perioperative VTE prevention research from 1999 to 2023. Research themes mainly focused on high-risk populations for VTE, high-risk types of surgery, risk factors and assessment, perioperative prevention, and nursing care. Current hot topics include "risk assessment" "anticoagulation therapy" "guidelines" "aspirin" and "rivaroxaban".Conclusions:Perioperative VTE prevention has increasingly garnered the attention of medical and nursing professionals. Future efforts should emphasize international exchange and cooperation to explore strategies for VTE prevention at different stages of the perioperative period and leverage information technology to enhance the quality of perioperative VTE prevention and management.