1.What moved into the lung? An unusual case of foreign body migration.
Yan-ting WANG ; Xiao-dong YANG ; Shao-hua LIU ; Yan-hua HUANG
Chinese Medical Sciences Journal 2013;28(4):248-249
Female
;
Foreign-Body Migration
;
complications
;
diagnosis
;
surgery
;
Humans
;
Lung
;
Middle Aged
;
Rib Fractures
;
complications
2.Diagnosis and treatment for the neck lump caused by migrating foreign body from the pharynx.
Xu WU ; Jing LIU ; Qing-Jie GUAN
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2006;41(7):516-516
Adult
;
Female
;
Foreign-Body Migration
;
complications
;
diagnosis
;
surgery
;
Humans
;
Male
;
Middle Aged
;
Neck
;
pathology
;
Pharynx
3.A Common Bile Duct Stone formed by Suture Material after Open Cholecystectomy.
Kook Hyun KIM ; Byung Ik JANG ; Tae Nyeun KIM
The Korean Journal of Internal Medicine 2007;22(4):279-282
The use of non-absorbable suture materials for cystic duct ligation after cholecystectomy can expose patients to the risk of recurrent stone formation in the common bile duct (CBD). However, in Korea suture materials have rarely been found to act as a nidus for common bile duct calculus formation. Recently, we experienced a case in which suture material, that had migrated from a previous cholecystectomy site into the CBD, probably served as a nidus for common bile duct stone formation. The stone was confirmed by endoscopic retrograde cholangiopancreatography (ERCP) and removed successfully using a basket. The authors report a case of surgical suture migration and discuss its subsequent role as a stone forming nucleus within the CBD in a patient who underwent open cholecystectomy; and include a review of the literature.
Aged
;
Cholangiopancreatography, Endoscopic Retrograde
;
Cholecystectomy/*adverse effects
;
Foreign Bodies/*complications
;
Foreign-Body Migration/*complications
;
Gallstones/*etiology/surgery
;
Humans
;
Male
;
Risk Factors
;
Surgical Instruments
;
Sutures/*adverse effects
4.Foreign Objects in Korean Prisoners.
Tae Hee LEE ; Young Woo KANG ; Hyun Jin KIM ; Sun Moon KIM ; Euyi Heog IM ; Kyu Chan HUH ; Young Woo CHOI ; Tae Hyo KIM ; Ok Jae LEE ; Un Tae JUNG
The Korean Journal of Internal Medicine 2007;22(4):275-278
BACKGROUND: Foreign objects in the gastrointestinal tract are usually the result of accidental swallowing. Yet foreign object ingestion is often seen in prisoners who mainly desire to leave prison. We report here on a series of 33 Korean prisoners with foreign object ingestion and they were treated endoscopically or surgically. METHDOS: We reviewed the medical records of 33 Korean prisoners (52 episodes) who were admitted due to ingestion of foreign objects between January 1998 and June 2004 to Konyang University Hospital and Gyeongsang National University Hospital. RESULTS: All the patients were male with a mean age of 35 years. The most common duration from ingestion to the visit to the ER was within 24 hours (25/52 episodes). Most of the foreign objects were located in the esophagus (42.3%) and stomach (42.3%). The number of foreign objects was one in 28 episodes, two in 12 episodes and three or more in twelve episodes. The most common foreign objects were metal wires (26/52 episodes). The mean size of the foreign objects was 11.9 centimeters long. Successful endoscopic treatment was performed in most patients (46/52 episodes, 88.5%). The remaining six cases were treated surgically. CONCLUSIONS: The foreign objects in prisoners were a variety of unusual things because of the prison environment, and endoscopy is a mainstay of treatment for foreign object removal in Korean prisoners.
Accidents
;
Adult
;
*Deglutition
;
*Endoscopy, Gastrointestinal
;
Foreign Bodies/*surgery
;
Foreign-Body Migration/complications/*surgery
;
Gastrointestinal Tract/*injuries
;
Humans
;
Korea
;
Male
;
*Prisoners
;
*Prisons
;
Risk Factors
5.Recent Advances of Biliary Stent Management.
Mitsuhiro KIDA ; Shiro MIYAZAWA ; Tomohisa IWAI ; Hiroko IKEDA ; Miyoko TAKEZAWA ; Hidehiko KIKUCHI ; Maya WATANABE ; Hiroshi IMAIZUMI ; Wasaburo KOIZUMI
Korean Journal of Radiology 2012;13(Suppl 1):S62-S66
Recent progress in chemotherapy has prolonged the survival of patients with malignant biliary strictures, leading to increased rates of stent occlusion. Even we employed metallic stents which contributed to higher rates and longer durations of patency, and occlusion of covered metallic stents now occurs in about half of all patients during their survival. We investigated the complication and patency rate for the removal of covered metallic stents, and found that the durations were similar for initial stent placement and re-intervention. In order to preserve patient quality of life, we currently recommend the use of covered metallic stents for patients with malignant biliary obstruction because of their removability and longest patency duration, even though uncovered metallic stents have similar patency durations.
Biliary Tract Diseases/*surgery
;
Coated Materials, Biocompatible
;
Device Removal
;
Drainage/methods
;
Endoscopy
;
Foreign-Body Migration/surgery
;
Humans
;
Metals
;
Postoperative Complications/surgery
;
*Stents/adverse effects
7.Role of Fully Covered Self-Expandable Metal Stent for Treatment of Benign Biliary Strictures and Bile Leaks.
Nonthalee PAUSAWASADI ; Tanassanee SOONTORNMANOKUL ; Rungsun RERKNIMITR
Korean Journal of Radiology 2012;13(Suppl 1):S67-S73
Endoscopic therapy by balloon dilation and placement of multiple large-bore plastic stents is the treatment of choice for benign biliary stricture. This approach is effective but it typically requires multiple endoscopic sessions given the short duration of stent patency. The endoscopic approach for treatment of bile leak involves the placement of a stent with or without biliary sphincterotomy. The self-expandable metal stent (SEMS) has traditionally been used for palliation of malignant biliary strictures given the long duration of stent patency owing to their larger stent diameter. Recently, SEMS has been used in a variety of benign biliary strictures and leaks, especially with the design of the covered self-expandable metal stent (CSEMS), which permits endoscopic-mediated stent removal. The use of CSEMS in benign biliary stricture could potentially result in a decrease in endoscopic sessions and it is technically easier when compared to placement of multiple plastic stents. However, complications such as cholecystitis due to blockage of cystic duct, stent migration, infection and pancreatitis have been reported. The potential subsegmental occlusion of contralateral intrahepatic ducts also limits the use of CSEMS in hilar stricture. Certain techniques and improvement of stent design may overcome these challenges in the future. Thus, CSEMS may be appropriate in only highly selected conditions, such as refractory benign biliary stricture, despite multiple plastic stent placement or difficult to treat bile duct stricture from chronic pancreatitis, and should not be used routinely. This review focuses on the use of fully covered self-expandable metal stent for benign biliary strictures and bile leaks.
*Bile
;
Biliary Tract Diseases/diagnosis/etiology/*surgery
;
Coated Materials, Biocompatible
;
Constriction, Pathologic
;
Diagnostic Imaging
;
Equipment Design
;
Foreign-Body Migration
;
Humans
;
Metals
;
Plastics
;
Postoperative Complications
;
Sphincterotomy, Endoscopic
;
*Stents
9.Kirschner wire migration from subcapital humeral fracture site, causing hydropneumothorax.
Balaji ZACHARIA ; Kishor PUTHEZHATH ; Ibin VARGHEES
Chinese Journal of Traumatology 2016;19(5):305-308
Migration of wires or pins around the shoulder is a known complication, though their migration within the chest is uncommon. We report an unusual case of hydropneumothorax due to migration of a bent Kirschner wire from the right proximal humerus in a 63 year-old man. We reviewed his clinical history, physical examination, imaging findings, surgical method and outcome. We also reviewed the literature on orthopaedic wire migration and latest technique in removal of the wires. Chest radiographs and chest computerized tomography are useful in detection and diagnosis of this disorder. Regular radiographic follow-up is needed for patients with internal fixation devices; any fractured or migrated pins or wires must be removed immediately to prevent dangerous complications. It is always important to remove the wires at the end of the treatment. Early removal of fixation wires and regular follow-up if wires are retained are essential to prevent serious complications.
Bone Wires
;
adverse effects
;
Foreign-Body Migration
;
complications
;
Humans
;
Humeral Fractures
;
surgery
;
Hydropneumothorax
;
etiology
;
Male
;
Middle Aged
;
Tomography, X-Ray Computed
10.A Silastic Sheet found during Endoscopic Transnasal Dacryocystorhinostomy for Acute Dacryocystitis.
Jin Seok CHOI ; Jong Hyeok LEE ; Hae Jung PAIK
Korean Journal of Ophthalmology 2006;20(1):65-69
PURPOSE: To report the case of a silastic sheet that was found during an endoscopic transnasal dacryocystorhinostomy for treatment of acute dacryocystitis with necrosis of the lacrimal sac. METHODS: A thirty-two year old male presented with painful swelling on the nasal side of his left lower lid two weeks prior to visiting this clinic. Fourteen years ago, the patient was involved in a traffic accident and underwent surgery to reconstruct the ethmoidal sinus. Lacrimal sac massage showed a regurgitation of a purulent discharge from the left lower punctum. Therefore, the patient was diagnosed with acute dacryocystitis and an endoscopic transnasal dacryocystostomy was performed the next day. RESULTS: The surgical finding showed severe necrosis around the lacrimal sac and a 20 x 15-mm sized silastic sheet was found crumpled within the purulent discharge. The sheet was removed, the lacrimal sac was irrigated with an antibiotic solution, and a silicone tube was intubated into the lacrimal pathway. After surgery, the painful swelling on the nasal side of left lower lid resolved gradually, and there were no symptomatic complications three months later. CONCLUSIONS: We report the first case where a silastic sheet applied during a facial reconstruction had migrated adjacent to the lacrimal sac resulting in severe inflammation.
Silicones/*adverse effects
;
Reoperation
;
Prosthesis Implantation
;
Prosthesis Failure
;
Male
;
Intraoperative Period
;
Humans
;
Foreign-Body Migration/*complications/surgery
;
Facial Injuries/surgery
;
Ethmoid Sinus/injuries/surgery
;
*Endoscopy
;
Dimethylpolysiloxanes/*adverse effects
;
Dacryocystorhinostomy/*methods
;
Dacryocystitis/*etiology/surgery
;
Adult