1.Current Status of External Quality Assessment of Syphilis Test in Korea.
Eun Young SONG ; Joo Seok YANG ; Seok Lae CHAE ; Serim KIM ; Young Sook CHOI ; Young Joo CHA
The Korean Journal of Laboratory Medicine 2008;28(3):207-213
BACKGROUND: Current status of external quality assessment (EQA) of laboratory tests for syphilis in Korea was analyzed to find out the problems that should be improved in the future. METHODS: Based on the data from the external quality assessment program performed twice a year by the Immunoserology Subcommittee of the Korean Association of Quality Assurance for Clinical Laboratory from the year 2004 to 2006, discordance rates were analyzed according to the test method and commercial kit used. RESULTS: Among the laboratories participating in the EQA program for syphilis test, about 90% of them used non-treponemal tests and about 55% treponemal tests. The non-treponemal tests included RPR (rapid plasma reagin) and VDRL tests used in 88% (363/412) and 11% (45/412), respectively, of the laboratories. The discordance rates were 2.2% for RPR test and 3.6% for VDRL. For the treponemal tests, Treponema pallidum hemagglutination assay (TPHA) was used in 60-76% and Immunochromatography assay (ICA) in about 30% of the laboratories in 2006. A high discordance rate of over 10% was reported in both TPHA and in ICA methods, possibly due to a low titer (1:1 in VDRL) of EQA samples in 2005. Analysis of the accumulated data from year 2004 to 2006 showed that the discordance rates of TPHA, ICA, and FTA-ABS were 4.6%, 3.7%, and 2.7%, respectively. CONCLUSIONS: For syphilis tests, RPR test, TPHA, and ICA are mainly used in Korea. A high discordance rate is still reported in TPHA and ICA, especially when testing samples with a low titer. Further analysis of data and education of laboratory personnel are needed for the improvement of the EQA program.
Enzyme-Linked Immunosorbent Assay
;
False Positive Reactions
;
Fluorescent Treponemal Antibody-Absorption Test
;
Humans
;
Korea
;
Quality Control
;
Reagent Kits, Diagnostic
;
Syphilis/*diagnosis
;
Syphilis Serodiagnosis/methods/*standards
;
Treponema Immobilization Test
2.Evaluation of Automated Architect Syphilis TP as a Diagnostic Laboratory Screening Test for Syphilis.
Jeeyong KIM ; Woo Hyeun KIM ; Chihyun CHO ; Juyeon KIM ; Ga Yeong KIM ; Myung Hyun NAM ; Jang Su KIM ; Sook Young BAE ; Yunjung CHO
The Korean Journal of Laboratory Medicine 2008;28(6):475-482
BACKGROUND: The aim of the study was to establish a new syphilis test algorithm using Architect Syphilis TP (Abbott Japan, Japan: AST), a fully automated treponemal antibody test, as a screening test in a university hospital laboratory. We evaluated performance characteristics of AST in various patient groups. METHODS: A total of 1,357 serum samples obtained from patients at a university hospital from June to August, 2008 were categorized into checkup, preoperative, other diseases, diagnosis (clinically suspected of syphilis), and follow up groups. We compared the results of AST with those of RPR (N=1,276) or Treponema pallidum hemagglutination assay (TPHA, N=81). Samples with discrepant results between RPR or TPHA and AST were retested by fluorescent treponemal antibody absorption test (FTA-ABS) and all patients' clinical records were thoroughly reviewed. RESULTS: The positive rate of AST was significantly higher than that of RPR in preoperative and other diseases groups and was the same as that of RPR in diagnosis group. There were no significant differences in check up and follow up groups. The results of AST showed 97.4% (1,243/1,276) and 97.5% (79/81) concordance rates with those of RPR and TPHA, respectively. Among 26 RPR-AST discrepant and FTA-ABS confirmed cases, there were 20 RPR false-negatives, 4 RPR false-positives, 1 AST false-negative, and 1 AST false-positive. CONCLUSIONS: Based on the results and literature review, we established a new syphilis test algorithm using AST as a screening test, which would be helpful for detection of more syphilis patients including latent infections.
Adolescent
;
Adult
;
Aged
;
Aged, 80 and over
;
Algorithms
;
Autoanalysis
;
Child
;
Child, Preschool
;
False Positive Reactions
;
Female
;
Fluorescent Treponemal Antibody-Absorption Test/methods
;
Hemagglutination Tests/methods
;
Humans
;
Male
;
Middle Aged
;
Reagent Kits, Diagnostic
;
Sensitivity and Specificity
;
Syphilis/*diagnosis
;
Syphilis Serodiagnosis/*methods