1.The New Sysmex XN-2000 Automated Blood Cell Analyzer More Accurately Measures the Absolute Number and the Proportion of Hematopoietic Stem and Progenitor Cells Than XE-2100 When Compared to Flow Cytometric Enumeration of CD34+ Cells.
Sang Hyuk PARK ; Chan Jeoung PARK ; Mi Jeong KIM ; Min Young HAN ; Sang Hee HAN ; Young Uk CHO ; Seongsoo JANG
Annals of Laboratory Medicine 2015;35(1):146-148
2.Reference Intervals for Platelet Parameters in Korean Adults Using ADVIA 2120.
Moon Jin KIM ; Pil Whan PARK ; Yiel Hea SEO ; Kyung Hee KIM ; Ja Young SEO ; Ji Hun JEONG ; Mi Jung PARK ; Jin Woo JUNG ; Jeong Yeal AHN
Annals of Laboratory Medicine 2013;33(5):364-366
No abstract available.
Adult
;
Aged
;
Aged, 80 and over
;
Blood Chemical Analysis/instrumentation
;
Blood Platelets/*cytology/physiology
;
Female
;
Flow Cytometry/*instrumentation/standards
;
Humans
;
Male
;
Middle Aged
;
Platelet Count/*instrumentation/standards
;
Reference Values
;
Republic of Korea
;
Young Adult
3.Comparison of ABO Antibody Titers on the Basis of the Antibody Detection Method Used.
Seon Joo KANG ; Young Ae LIM ; Sae Yun BAIK
Annals of Laboratory Medicine 2014;34(4):300-306
BACKGROUND: Detection methods for ABO antibody (Ab) titers vary across laboratories, and the results are different depending on the method used. We aimed to compare titer values using different detection methods for the measurement of ABO Ab titers. METHODS: For ABO Ab detection, pooled group A or B red blood cells (RBCs) were reacted with each of 20 sera from blood groups A, B, or O without dithiothreitol treatment. The room-temperature (RT) incubation technique and the indirect antiglobulin test (IAT) were used in the tube test and gel card test. Flow cytometry (FCM) was performed by using anti-IgM and anti-IgG Abs. RESULTS: Regardless of the blood groups tested, the FCM assay with anti-IgM showed the highest titer compared to the tube test and gel card test with RT incubation in both. The tube test with IAT showed a higher titer than the gel card test with IAT (Gel-IAT) or FCM with anti-IgG in blood group A and B, while Gel-IAT showed the highest titer relative to the other tests, only for the anti-A Ab in blood group O. CONCLUSIONS: There were significant differences in the titers depending on the detection method used, and each method showed a different detection capacity for each ABO Ab depending on the ABO blood group tested. Therefore, caution should be exercised in interpreting ABO Ab titer results, taking into consideration the detection method used and the blood group.
ABO Blood-Group System/*immunology
;
Adult
;
Aged
;
Agglutination Tests/instrumentation/*standards
;
Antibodies/*analysis
;
Antibodies, Anti-Idiotypic/analysis
;
Erythrocytes/chemistry/metabolism
;
Female
;
*Flow Cytometry
;
Humans
;
Male
;
Middle Aged
;
Temperature
4.Study on large-scale CD34+ cell enrichment using immunomagnetic isolation apparatus.
Hong LIU ; Sui CAO ; Xiu-Bao REN ; Peng ZHANG ; Xiu-Mei AN ; Xi-Shan HAO
Journal of Experimental Hematology 2004;12(6):798-802
In order to find a method suitable for purifying large amount of CD34(+) cells, from 5 cases who accepted autologous peripheral blood stem cell transplantation, CD34(+) cells were collected and enriched by using Isolex 300i (Nexell). Phenotypes were detected by flow cytometry and the biological viability were assayed by the colony-forming experiments and cell expansion experiment in vitro. The results showed that the number of mononuclear cells first collected was about (3.5 - 6.0) x 10(10) and (0.55 - 1.2)% of cells were CD34 positive. The number of positive production was about (2.0 - 3.0) x 10(8); the CD34(+) cells purity was (75 - 85)% and the yield was (40 - 65)%. The CD34(+) cells of positive production could expand up to 2 - 3 times when cultured with SCF + IL3 + FL + TPO + EPO in vitro. The results of colony-forming experiments demonstrated that the CD34(+) cells collected has enough colony-forming ability. All results showed the enriched CD34(+) cells with biological viability. In conclusion, the CD34(+) immunomagnetic isolation apparatus Isolex300i is suitable to clinical application for a large amount of CD34(+) cell enrichment.
Antigens, CD34
;
immunology
;
Colony-Forming Units Assay
;
Flow Cytometry
;
Hematopoietic Stem Cells
;
cytology
;
immunology
;
Humans
;
Immunomagnetic Separation
;
instrumentation
;
methods
;
standards
;
Neoplasms
;
blood