1.The effect of high-pass filter circuit on accurate measurement of ST-segment.
Yantao SONG ; Caibing ZHU ; Lanlan WEI ; Fan WANG ; Jilun YE ; Xu ZHANG ; Xiaodong HUANG
Chinese Journal of Medical Instrumentation 2013;37(5):319-321
The high-pass filter which is designed to overcome the polarization voltage in the ECG measurements can affect the measurement of the ST-segment; but the accuracy of the ST-segment will have an impact on the diagnosis and treatment of heart diseases. This paper used the ECG detection platform to test the effect of the high-pass filter at different frequency and studied the effect of the high-pass filter on the ST segment to ensure proper use of different application modes.
Electrocardiography
;
instrumentation
;
methods
;
Filtration
2.Study and compare of the bidirectional filtering technique for anti-baseline drift.
Lingfeng KONG ; Daxue WEI ; Yunpeng LIAO
Chinese Journal of Medical Instrumentation 2010;34(4):263-265
Several digital filtering techniques for correcting baseline drift from ECG signals are presented. A bidirectional filter is introduced, which can cantain baseline drift their filtering performance and realization methods are compared.
Electrocardiography
;
instrumentation
;
methods
;
Filtration
;
instrumentation
;
Signal Processing, Computer-Assisted
;
instrumentation
3.Research of Disposable Respiratory Filter to the Measurement of Impulse Oscillometery.
Chinese Journal of Medical Instrumentation 2020;44(1):76-79
OBJECTIVE:
To study the influence of disposable respiratory filter on the results of impulse oscillometery.
METHODS:
90 healthy subjects were randomly selected and impulse oscillometery results were taken repeatedly through disposable respiratory filter and control device. All results were statistically analyzed.
RESULTS:
When using the disposable respiratory filter, respiratory impedance (Zrs) and resistance at all frequency (R5Hz-R35Hz) were significantly increased compared with the control device (P<0.01). The two measurements had a significant linear correlation (P<0.01) and a regression equation was established. The disposable respiratory filter did not exist in statistic difference to response frequency (Fres) and the elastic resistance (X5Hz-X15Hz) at all frequency(P>0.05).
CONCLUSIONS
The disposable respiratory filter can be used when testing pulmonary compliance, chest wall disease and obstruction outside the airway in impulse oscillometery system to avoid infection and ensure quality.
Airway Resistance
;
Filtration/instrumentation*
;
Humans
;
Oscillometry
4.The effect of leukocyte depletion by filtration on the quality of apheresis platelets.
Yang YU ; Qian FENG ; Ting ZHANG ; Chun-Ya MA ; Xiao-Juan ZHANG ; Guo-Feng GE ; Zi-Lin LIN ; Ji-Chun PAN ; De-Qing WANG ; Qun LUO ; Ya-Ping TIAN
Journal of Experimental Hematology 2009;17(4):1067-1070
This study was aimed to investigate the effect of leukocyte depletion by filtration on the quality of apheresis platelets. 20 units of donor apheresis platelets were randomly selected and were preserved with agitation at 20 - 24 degrees C for 24 - 96 hours, then were filtered on polyester flatbed filters. The platelet concentration, mean platelet volume (MPV), volume of apheresis platelets, leukocyte count, pH value, lactate dehydrogenase (LDH) concentration, K(+) concentration and CD62p expression level on surface of platelet membrane, were detected before and after filtration, as well as the rate of leukocyte depletion and platelet loss were calculated. The results showed that the leukocyte count after filtration was remarkably lower than that before filtration (p < 0.001), and the rate of leukocyte depletion was 99.97%. Platelet loss was approximately 8%, and obviously lower than that of the national standard (p < 0.001). MPV, pH value, K(+) and LDH concentration were not significantly different before and after filtration. Compared with platelets before filtration, CD62p expression level after filtration slightly decreased (p > 0.05). CD62p expression on surface of platelet membrane in perfusion fluid obtained from filter plate was obviously higher than that before filtration (p < 0.05). MA of platelet after filtration slightly decreased (p > 0.05). It is concluded that leukocyte and partial activated platelets can be removed efficiently by using polyester flatbed filters, and platelet loss is very low. Filtration does not adversely affect coagulation activity of the platelets in vitro. Apheresis platelets after filtration can fulfil quality requirements to prevent infection of cytomegalovirus and HLA alloimmunization.
Filtration
;
Humans
;
Leukapheresis
;
instrumentation
;
Platelet Count
;
Plateletpheresis
;
instrumentation
;
methods
5.Membrane separation technique and its application in research and medicine production.
China Journal of Chinese Materia Medica 2006;31(15):1221-1224
The membrane separation is a new practical technique with wide applications. This paper introduces the course of its development, theorem and feature, and the usage of its module. Its application in the research and production is reviewed. Its existent questions in the applications presently are analyzed and the relevant resolvents are brought forward.
Filtration
;
instrumentation
;
methods
;
Hemofiltration
;
instrumentation
;
Micropore Filters
;
Technology, Pharmaceutical
;
instrumentation
;
methods
;
Ultrafiltration
;
instrumentation
;
methods
6.Natural water purification and water management by artificial groundwater recharge.
Journal of Zhejiang University. Science. B 2008;9(3):221-226
Worldwide, several regions suffer from water scarcity and contamination. The infiltration and subsurface storage of rain and river water can reduce water stress. Artificial groundwater recharge, possibly combined with bank filtration, plant purification and/or the use of subsurface dams and artificial aquifers, is especially advantageous in areas where layers of gravel and sand exist below the earth's surface. Artificial infiltration of surface water into the uppermost aquifer has qualitative and quantitative advantages. The contamination of infiltrated river water will be reduced by natural attenuation. Clay minerals, iron hydroxide and humic matter as well as microorganisms located in the subsurface have high decontamination capacities. By this, a final water treatment, if necessary, becomes much easier and cheaper. The quantitative effect concerns the seasonally changing river discharge that influences the possibility of water extraction for drinking water purposes. Such changes can be equalised by seasonally adapted infiltration/extraction of water in/out of the aquifer according to the river discharge and the water need. This method enables a continuous water supply over the whole year. Generally, artificially recharged groundwater is better protected against pollution than surface water, and the delimitation of water protection zones makes it even more save.
Filtration
;
Fresh Water
;
analysis
;
Water Purification
;
instrumentation
;
methods
;
Water Supply
7.Simplified identification and filter device of carbon dioxide.
Chinese Journal of Medical Instrumentation 2009;33(6):461-462
This paper presents the design and implementation ways of a simplified device to identify and filter carbon dioxide. The gas went through the test interface which had wet litmus paper before entering the abdominal cavity. Carbon dioxide dissolving in water turned acidic, making litmus paper change color to identify carbon dioxide, in order to avoid malpractice by connecting the wrong gas when making Endoscopic surgery.
Carbon Dioxide
;
Endoscopy
;
Equipment Design
;
Equipment Safety
;
Filtration
;
instrumentation
8.Research for the test method of polypropylene fiber liquid filtration membrane particles shedding.
Jinzi SONG ; Yufei JIA ; Yulian CHAI ; Bingcheng SUN ; Haixin LI
Chinese Journal of Medical Instrumentation 2011;35(6):446-448
Through five experiments, such as "Circle", "square", "side that does not shake", "burning edge", "filter", this paper discussed the effect of different experimental methods of polypropylene fiber liquid filtration membrane particles shedding. The results show that: the particles falling off the edge of the polypropylene fiber Double-sided liquid filtration membrane are very important and must be considered off the evaluation of particle pollution.
Equipment Failure
;
Filtration
;
instrumentation
;
methods
;
Particle Size
;
Polypropylenes
9.Effect of humidity and temperature on filter and gravimetric measurement of ambient particulate matter in a balance room.
Wen-jin SU ; Li-min WANG ; Shao-fan WENG ; Hai-jiao WANG ; Li-li DU ; Yue-wei LIU ; Lei YANG ; Wei-hong CHEN
Chinese Journal of Industrial Hygiene and Occupational Diseases 2008;26(4):198-202
OBJECTIVETo assess the effects of the alteration of humidity and (or) temperature on weight of filters without and with ambient particulate matter in a balance room.
METHODSThe mass of blank dust sampling filters were weighed under (18 +/- 1) degrees C and (28 +/- 1) degrees C respectively, with the humidity varying from 35% relative humidity (RH) to 100% RH in a balance room. Then the blank filters were divided into two groups and were used to sample total dust and respirable dust. After sampling, the loaded filters were re-weighed under above conditions and the mass difference before and after the sampling were compared and analyzed.
RESULTSThe vibration of the average mass of filters varied from 0.10 to 0.13 mg and from 0.06 to 0.09 mg under the temperatures of (18 +/- 1) degrees C and (28 +/- 1) degrees C respectively; When both the temperature and humidity changed, it varied from 0.12 to 0.16 mg. The deviation of average mass difference ranged from 0.07 to 0.10 mg and from 0.04 to 0.08 mg under the two temperatures mentioned above; When both the temperature and humidity changed, it varied from 0.09 to 0.14 mg. The average mass of blank filters and loaded filters were all positively correlated with the change of humidity (P < 0.01). No effects of humidity on the average mass difference of the loaded filters were observed. The average mass differences of loaded filters and blank filters under (18 +/- 1) degrees C were significantly higher than that under (28 +/- 1) degrees C (P < 0.01) when humidity was not changed.
CONCLUSIONThe alteration of humidity and (or) temperature in a balance room attributes to the deviation of the measurement of the mass of filters and thus affects the gravimetric measurements of ambient particulate matter.
Air Pollutants ; analysis ; Environmental Monitoring ; instrumentation ; Filtration ; instrumentation ; Humidity ; Particulate Matter ; analysis ; Temperature
10.The effect of two leukocyte depletion in-line filters on the efficiency of whole blood filtration.
Rufeng XIE ; Yun LI ; Yuwen HUANG ; Qing MO ; Yongchao DAI ; Weilong TANG
Journal of Biomedical Engineering 2007;24(4):817-819
The aim of this study was to observe the difference in respect to the leukocyte reduction efficiency and quality of fresh-frozen plasma (FFP) from filtered whole blood between two types of in-line filters wherein only filter materials were surface modified by the two methods respectively. Whole blood was kept in refrigerator and filtered within 6 h of collection at ambient temperature. Samples were taken pre- and post filtration for analysis of WBC numbers, coagulation factors and complement activation (n = 8 for each type of filter). All filtered units contained < 2. 5 x 10(6) residual leucocytes. RBCs recovery was over 93%. No significant difference between group A and B was seen. But group B appeared to take longer time for filtration than did group A (9'29" vs. 8'01"). Neither group A nor group B showed statistically significant losses of total protein, album, IgG, IgM, fibrin, factors VIII, IX, vWF and C3 (P > 0.05). Factor V, XI and AT-III decreased significantly in two group filters. Group B showed more significant losses of IgA content and factor V activity than did group A, which appeared to be related to the difference in surface character between group A and group B filters. These two types of filters could remove leukocytes effectively, and no significant changes were observed in the quality of FFP from the filtered whole blood. It is presumed that the filter material with better bio-compatibility will give a high recovery of plasma protein and coagulation factors after filtration.
Blood Coagulation Factors
;
metabolism
;
Filtration
;
instrumentation
;
methods
;
Humans
;
Leukocyte Count
;
Leukocyte Reduction Procedures
;
instrumentation
;