1.The effect of high-pass filter circuit on accurate measurement of ST-segment.
Yantao SONG ; Caibing ZHU ; Lanlan WEI ; Fan WANG ; Jilun YE ; Xu ZHANG ; Xiaodong HUANG
Chinese Journal of Medical Instrumentation 2013;37(5):319-321
The high-pass filter which is designed to overcome the polarization voltage in the ECG measurements can affect the measurement of the ST-segment; but the accuracy of the ST-segment will have an impact on the diagnosis and treatment of heart diseases. This paper used the ECG detection platform to test the effect of the high-pass filter at different frequency and studied the effect of the high-pass filter on the ST segment to ensure proper use of different application modes.
Electrocardiography
;
instrumentation
;
methods
;
Filtration
2.Aquaculture solids management using a combination of sand/gravel or unwoven fabric bed with Lolium perenne Lam as a plant biofilter.
André NDUWIMANA ; Xiang-Long YANG ; Li-Ren WANG
Biomedical and Environmental Sciences 2007;20(6):439-444
OBJECTIVEThis work is an evaluation of the efficiency of a sand-gravel or unwoven fabric bed system and Lolium perenne Lam as plant biofilter in the reduction of solids and nutrients removal from aquaculture discharge water.
METHODSThe first step consisted of the collection of wastewater in the tank and the distribution at three different hydraulic loading regimes (0.5, 1, 1.5 L/hour) to the different experimental systems. The second step was to evaluate the performance of the different systems. The first system consisted of a bucket filled with a substrate of sand/gravel (20 cm in depth), on the bottom of which was a 80 mesh/inch2 of nylon (S1); the second was similar, but was planted with Lolium perenne lam (S2); the third was planted with a grass plate consisting of 7 layers of unwoven fabric planted with L perenne (S3).
RESULTSThe second system showed the best performance in reducing solids as well as in nutrients (TN, TP, and COD) reduction. The removal rates for TS, TN, and TP were negatively correlated with the loading regimes, with 0.5 L/hour being the most efficient and thus taken as the reference.
CONCLUSIONSSolids management using a sand/gravel substrate as bed culture and Lolium perenne L. as plant biofilter has proved to be an efficient technique for solids reduction with low operating cost. This grass plays an important role in wastewater eco-treatment by absorbing dissolved pollutants (TAN) as nutrients for its growth.
Aquaculture ; Filtration ; methods ; Lolium ; metabolism ; Silicon Dioxide
3.Estimation of Glomerular Filtration Rate(GFR) Using (99m)Tc-DTPA Renal Scan and the Parameters for Renal Function.
Ihn Ho CHO ; Hyun Dae YOON ; Kyu Chang WON ; Chan Woo LEE ; Hyoung Woo LEE ; Hyun Woo LEE
Yeungnam University Journal of Medicine 1994;11(1):101-108
Many previously described nuclear medicine procedures to assess glomerular filtration rate have some problems because numerous blood sample is to be taken and they don't measure each separate renal function. Gates described isotopic method for the measurement of global and unilateral GFR based on the fractional renal uptake of (99m)Tc-DTPA 2 to 3 minutes after its intravenous injection. We evaluated GFR using (99m)Tc-DTPA in 57 people according to Gates method and compared with creatinine clearance. A good correlation was observed between creatinine clearance and GRF calculated by Gates' formula with an r value of 0.9(P<0.05). And also the relationship between parameters of (99m)Tc-DTPA renal scan images and GFR was taken. They were significantly correlated with GFR calculated by Gates' formula : r value 0.66 between relative intensity of peak renal to peak aortic activity(pK/pA) and GFR, -0.42 between time between aortic and kidney peak(A-K) and GFR and -0.48 between parenchymal renal activity at 25 min compared to peak kidney activity(25K/pK) and GRF. In conclusion, the determination of GFR according to Gates' formula shows good and reproducible of GRF with rapidity and simplicity. And the parameters from the renal scan images can use to estimate the renal function.
Creatinine
;
Filtration*
;
Glomerular Filtration Rate
;
Injections, Intravenous
;
Kidney
;
Methods
;
Nuclear Medicine
4.Study and compare of the bidirectional filtering technique for anti-baseline drift.
Lingfeng KONG ; Daxue WEI ; Yunpeng LIAO
Chinese Journal of Medical Instrumentation 2010;34(4):263-265
Several digital filtering techniques for correcting baseline drift from ECG signals are presented. A bidirectional filter is introduced, which can cantain baseline drift their filtering performance and realization methods are compared.
Electrocardiography
;
instrumentation
;
methods
;
Filtration
;
instrumentation
;
Signal Processing, Computer-Assisted
;
instrumentation
5.Research for the test method of polypropylene fiber liquid filtration membrane particles shedding.
Jinzi SONG ; Yufei JIA ; Yulian CHAI ; Bingcheng SUN ; Haixin LI
Chinese Journal of Medical Instrumentation 2011;35(6):446-448
Through five experiments, such as "Circle", "square", "side that does not shake", "burning edge", "filter", this paper discussed the effect of different experimental methods of polypropylene fiber liquid filtration membrane particles shedding. The results show that: the particles falling off the edge of the polypropylene fiber Double-sided liquid filtration membrane are very important and must be considered off the evaluation of particle pollution.
Equipment Failure
;
Filtration
;
instrumentation
;
methods
;
Particle Size
;
Polypropylenes
6.The effect of leukocyte depletion by filtration on the quality of apheresis platelets.
Yang YU ; Qian FENG ; Ting ZHANG ; Chun-Ya MA ; Xiao-Juan ZHANG ; Guo-Feng GE ; Zi-Lin LIN ; Ji-Chun PAN ; De-Qing WANG ; Qun LUO ; Ya-Ping TIAN
Journal of Experimental Hematology 2009;17(4):1067-1070
This study was aimed to investigate the effect of leukocyte depletion by filtration on the quality of apheresis platelets. 20 units of donor apheresis platelets were randomly selected and were preserved with agitation at 20 - 24 degrees C for 24 - 96 hours, then were filtered on polyester flatbed filters. The platelet concentration, mean platelet volume (MPV), volume of apheresis platelets, leukocyte count, pH value, lactate dehydrogenase (LDH) concentration, K(+) concentration and CD62p expression level on surface of platelet membrane, were detected before and after filtration, as well as the rate of leukocyte depletion and platelet loss were calculated. The results showed that the leukocyte count after filtration was remarkably lower than that before filtration (p < 0.001), and the rate of leukocyte depletion was 99.97%. Platelet loss was approximately 8%, and obviously lower than that of the national standard (p < 0.001). MPV, pH value, K(+) and LDH concentration were not significantly different before and after filtration. Compared with platelets before filtration, CD62p expression level after filtration slightly decreased (p > 0.05). CD62p expression on surface of platelet membrane in perfusion fluid obtained from filter plate was obviously higher than that before filtration (p < 0.05). MA of platelet after filtration slightly decreased (p > 0.05). It is concluded that leukocyte and partial activated platelets can be removed efficiently by using polyester flatbed filters, and platelet loss is very low. Filtration does not adversely affect coagulation activity of the platelets in vitro. Apheresis platelets after filtration can fulfil quality requirements to prevent infection of cytomegalovirus and HLA alloimmunization.
Filtration
;
Humans
;
Leukapheresis
;
instrumentation
;
Platelet Count
;
Plateletpheresis
;
instrumentation
;
methods
7.Natural water purification and water management by artificial groundwater recharge.
Journal of Zhejiang University. Science. B 2008;9(3):221-226
Worldwide, several regions suffer from water scarcity and contamination. The infiltration and subsurface storage of rain and river water can reduce water stress. Artificial groundwater recharge, possibly combined with bank filtration, plant purification and/or the use of subsurface dams and artificial aquifers, is especially advantageous in areas where layers of gravel and sand exist below the earth's surface. Artificial infiltration of surface water into the uppermost aquifer has qualitative and quantitative advantages. The contamination of infiltrated river water will be reduced by natural attenuation. Clay minerals, iron hydroxide and humic matter as well as microorganisms located in the subsurface have high decontamination capacities. By this, a final water treatment, if necessary, becomes much easier and cheaper. The quantitative effect concerns the seasonally changing river discharge that influences the possibility of water extraction for drinking water purposes. Such changes can be equalised by seasonally adapted infiltration/extraction of water in/out of the aquifer according to the river discharge and the water need. This method enables a continuous water supply over the whole year. Generally, artificially recharged groundwater is better protected against pollution than surface water, and the delimitation of water protection zones makes it even more save.
Filtration
;
Fresh Water
;
analysis
;
Water Purification
;
instrumentation
;
methods
;
Water Supply
8.A Comparison of the Accuracy of Different Single Plasma Sample Methods for Measuring Glomerular Filtration Rate Using ⁵¹Cr-EDTA in Children
Nuclear Medicine and Molecular Imaging 2018;52(4):293-302
PURPOSE: Among the different methods of measuring glomerular filtration rate (GFR) using 51Cr-ethylenediaminetetraacetic acid clearance, the two-plasma-sample method (TPSM) is widely used, and highly accurate. The single-plasma-sample method (SPSM) is occasionally used for simplicity, at the expense of accuracy. Our aims were (1) to investigate the correlation and (2) to compare the accuracy of six known SPSMs in pediatric patients in reference to TPSM.METHODS: We retrospectively reviewed 122 pediatric cases (65 boys, age 7.3 ± 4.6 years) and analyzed 307 GFR measurements. SPSMs included Groth and Aasted at 120 min, Hamat 120 min, Christensen and Groth at 120 and 240 min, and Jacobsson at 120 and 240 min. Reference GFR (GFRref) was defined using TPSM GFR corrected by the Jodal and Brochner-Mortensen equation. GFRref < 30 mL min−1 1.73 m−2 were excluded. The standard error of the estimate (SEE) and the number of cases with differences > 10% (N10%) were used to evaluate accuracy.RESULTS: SPSMs generally correlated well with GFRref (r = 0.92~0.99) and were relatively accurate (SEE = 9.21~15.60). Groth and Aasted showed the smallest SEE, while Jacobsson at 240 min showed the smallest N10% for all GFRref ranges. As for the decreased GFRref, Ham was most accurate followed by Jacobsson at 240 min.CONCLUSIONS: Jacobsson at 240 min provided good accuracy in all GFRref ranges and was well correlated with TPSM. Jacobsson at 240 min might be the most appropriate method to substitute for TPSM in pediatric patients. Ham could be an alternative in patients with impaired renal function.
Child
;
Glomerular Filtration Rate
;
Humans
;
Methods
;
Plasma
;
Retrospective Studies
9.Membrane separation technique and its application in research and medicine production.
China Journal of Chinese Materia Medica 2006;31(15):1221-1224
The membrane separation is a new practical technique with wide applications. This paper introduces the course of its development, theorem and feature, and the usage of its module. Its application in the research and production is reviewed. Its existent questions in the applications presently are analyzed and the relevant resolvents are brought forward.
Filtration
;
instrumentation
;
methods
;
Hemofiltration
;
instrumentation
;
Micropore Filters
;
Technology, Pharmaceutical
;
instrumentation
;
methods
;
Ultrafiltration
;
instrumentation
;
methods
10.Facial aesthetic fat graft retention rates after filtration, centrifugation, or sedimentation processing techniques measured using three-dimensional surface imaging devices.
Guan-Hui-Er WANG ; Jian-Fang ZHAO ; Hong-Yu XUE ; Dong LI
Chinese Medical Journal 2019;132(1):69-77
OBJECTIVE:
How to increase the long-term retention rate of autologous fat grafting has been widely discussed. This study aimed to evaluate long-term fat graft retention rates for the most widely used fat processing methods in the area of facial esthetic surgery, including centrifugation, filtration, and sedimentation, using three-dimensional (3D) imaging.
DATA SOURCES:
PubMed, Embase, Wiley/Cochrane Library, and Web of Science databases were comprehensively searched from inception to July 2018 according to the guidelines of the American Society of Plastic Surgeons Fat Graft Task Force Assessment Methodology.
STUDY SELECTION:
Articles were screened using predetermined inclusion and exclusion criteria. Data collected included patient characteristics, follow-up devices, fat grafting techniques, and clinical outcomes. Patient cohorts were pooled, and fat graft retention rates were calculated. Complications were summarized according to different clinical characteristics.
RESULTS:
Of 77 articles, 10 clinical studies met the inclusion criteria and reported quantified measurement outcomes with 3D imaging which provide precise volumetric data with approximately 2% standard deviation compared to real volumes. Data of 515 patients were included. Fat grafting retention varied from 21% to 82%. We found filtration and centrifugation techniques could result in better retention outcomes. However, retention varied within each processing technique, with no significant difference among the 3 techniques. Twenty-two complications were reported among 515 patients, including donor-site hematoma (1 case), mild post-operative erythema (2 cases), mild volumetric asymmetries (2 cases), chronic edema (2 cases), overcorrection (2 cases), skin irregularity (6 cases), and headache or dysesthesia (7 cases).
CONCLUSIONS
Filtration and centrifugation techniques may result in better fat grafting retention outcomes than gravity sedimentation; however, more accurate statistical evidence is needed. Controversies continue to exist with respect to the performance of the different fat-processing techniques in fat graft retention.
Adipocytes
;
cytology
;
Adipose Tissue
;
cytology
;
Centrifugation
;
methods
;
Filtration
;
methods
;
Humans
;
Imaging, Three-Dimensional
;
methods