1.Study of appropriateness of laboratory reports for clinical hematology in China
Fengfeng KANG ; Wei WANG ; Zhiguo WANG
Chinese Journal of Laboratory Medicine 2015;(9):632-636
Objective To investigate the status of report appropriateness in Clinical Hematology and to identify its potential influence factors to improve the quality of laboratory reports.Methods 1 120 National External Quality Assessment ( EQA ) participants laboratories were enrolled in this study.The questionnaires were assigned to all the participants in both electronic and printed form.The participants were asked to retrospectively count the total reports and the affected reports while the following quality indicators occurred in 2012:report delay, inconformity of data between instrument and LIS as well as between report and request erroneous report transportation, report recall, and report modification.All quality indicators were evaluated in two ways:percentage and sigma (σ) scale.Mann-Whitney Test and Kruskal-Wallis Test were used to analyze the potential impacts of report appropriateness.Results Totally 609 (54.38%)laboratories submitted the survey results .The sigma metrics of six quality indicators on report appropriateness were more than 4.The main reason for report delay was equipment failure.Group comparison suggested that the report appropriateness of laboratories in tertiary-A hospitals and accredited by ISO 15189 werebetter.Report appropriateness with electronic request, electronic form and electronic transmission were superior than that inother ways. Conclusions Report appropriateness in China differs from laboratory to laboratory. Laboratories should develop emergency action plan in case the instrument breaks down and strengthen information technology .Long-term internal quality control and external quality assessment scheme are very meaningful to identify the insufficient performance and improve laboratory quality .(Chin J Lab Med, 2015,38:632-636)
2.External quality assessment of clinical laboratory quality indicators in China in 2015
Yang FEI ; Fengfeng KANG ; Wei WANG ; Haijian ZHAO ; Minqi WANG ; Bingquan CHEN ; Jie ZHOU ; Zhiguo WANG
Chinese Journal of Laboratory Medicine 2016;39(6):433-437
Objective To investigate an evaluation program for external quality assessment ( EQA) of quality indicators ( QIs) and develop a software .Methods According to GB/T 27043-2012 ( ISO/IEC 17043:2010,IDT) mode 3, 28 provincial centers for clinical Laboratories were organized by National Center for Clinical Laboratories to launch an investigation on “QIs in clinical laboratory” with the use of Clinet-EQA online .Participants were asked to collect data of April 2014 and report related results online .Mean, median, the 5 th, 25 th, 75 th and 95 th percentiles of defectpercentages for biochemistry , immunology, blood and body fluid and microbiology were calculated , respectively .Sigma values were also calculated . Meanwhile , 25 th of sigma value and 75 th of defect percentages were chosen as preliminary quality specifications for each QI so that laboratories can evaluate related process quality .Results Take incorrect sample type rates for example , 4 771 laboratories were involved in this study .Among four subjects , incorrect sample type rates were lowest (0.01%, 6σ) for immunology tests, followed by blood and body fluids tests (0.06%, 4.7σ) and biochemistry tests (0.06%, 4.7σ), and were highest for microbiology tests (0.33%, 4.2σ).Evaluation reports will besent back to participants so that they can understand national , provincial , and their own sigma levels well .Preliminary quality specifications of incorrect sample type for biochemistry, immunology, blood and body fluid, and microbiology tests were 0.08% (4.6σ), 0.03%(5σ), 0.09%(4.6σ) and 0.43%(4.1σ), respectively.Conclusion Clinical laboratories were advised to establish and monitor suitable QIs within laboratory and participate in QIs EQA schemes , thus they can improve their quality continuously .
3.Analysis of 15 quality indicators in clinical laboratory in Zhejiang province
Weixing LI ; Zhiguo WANG ; Fengfeng KANG ; Zhiming SHAN ; Chao SONG ; Bingquan CHEN ; Mingqi WANG ; Jie ZHOU
Chinese Journal of Laboratory Medicine 2016;(1):23-28
Objective To establish and apply the procedure of survey on quality indicator in clinical laboratory and to analyze the status in quo of the 15 quality indicators in Zhejiang province .Methods A network platform for the survey on quality indicator in clinical laboratory was designed and developed by our center.The online questionnaires that should be reported back within one month were assigned to 473 laboratories.The developed software and SPSS 13.0 were used for statistical analysis .13 indicators expressed in rate were further evaluated with sigma scales .The 25th percentile, 50th percentile, and 75th percentile of the distribution of each quality indicator were regarded as the minimum , appropriate and optimum quality specifications, respectively.Results Totally 444 laboratories submitted the survey results.The overall sigma levels of 10/13 indicators were all >3, of which the inappropriate CV of internal quality control and unacceptable performances in EQA were still less than 3σin 15.8%and 9.2%of the laboratories.The rates of quality indicators in different scales of laboratories and diverse disciplines were significantly different .Pre-analytical TAT in routine examination for clinical chemistry and immunology was 50 min, on average.And the time for routine examination of blood , urine and stool was 30 min.Pre-analytical TAT in emergency examination for all four disciplines were all between 10 and 15 min. Intra-analytical TAT for clinical immunology was the longest , which was 154 min for routine examination and 40 min for emergency examination, respectively.The optimum quality specifications for 8 indicators were 6σ, while the minimum quality specifications were less than 1σfor 4 indicators.Conclusions According to the results of our survey, the pre-analytical quality indicator perform better than that of Intra-analytical and post-analytical phase.The laboratory should strengthen the laboratory information system technology construction to ensure the reliable data collection and long-time monitoring.
4.Status analysis of 15 quality indicators at clinical laboratorieis of 8029 medical institutions in China
Fengfeng KANG ; Weixing LI ; Wei WANG ; Haijian ZHAO ; Bingquan CHEN ; Zhiguo WANG
Chinese Journal of Hospital Administration 2018;34(1):64-69
Objective To investigate the 15 quality indicators at medical institutions in China , and to explore the model of quality specifications .Methods Online questionnaires were sent to 8029 clinical laboratories ,with the results analyzed by SPSS 20 .The 25th percentile ,50th percentile ,and 75th percentile of the distribution ,according to the level of the hospital ,were regarded as the optimum , appropriate and minimum quality specifications for each quality indicator ,respectively .Results As shown in the median ,sigma values of most indicators were greater than 3 .The defect percentages of test uncovered by internal quality control (IQC)and test uncovered by inter-laboratory comparison were 47.46% and 85.73% ,respectively ,both too poor to calculate the sigma values. The turnaround time (TAT )differed greatly among the subjects.The longest time of pre-examination TAt and Intra-laboratory TAT were clinical immunity. The minimum quality specifications for the quality indicators were from 3σ to 6σ.Conclusions Laboratories should strengthen their IQc and inter-laboratory comparison with continuing education training to realize the continuous quality improvement .
5.Early internal fixation combined with perforator flap for treatment of forearm open fractures with soft tissue defects of Gustilo types Ⅲ B & Ⅲ C
Yongjun RUI ; Yongwei WU ; Jun LIU ; Fengfeng LI ; Yunhong MA ; Yao LU ; Yongqiang KANG ; Ming ZHOU ; Tong YANG ; Fang LIN
Chinese Journal of Orthopaedic Trauma 2018;20(8):648-653
Objective To investigate the clinical therapy of early internal fixation combined with perforator flap for forearm open fractures of Gustilo types Ⅲ B & Ⅲ C.Methods A retrospective study was conducted of the 45 patients with forearm open fracture of Gustilo type ⅢB or Ⅲ C who had been treated from July 2012 to October 2016 at Department of Traumatic Orthopaedics,The Ninth People's Hospital of Wuxi.They were 26 men and 19 women,aged from 20 to 61 years (average,41 years).Twenty cases were Gustilo type ⅢB and 25 Gustilo type ⅢC.By AO classification,8 cases were type A,21 ones type B,and 16 ones type C.The wound size ranged from 4 cm × 3 cm to 36 cm × 8 cm.Thirty-three patients were treated by primary internal fixation plus secondary transfer with a perforator flap,12 ones by secondary internal fixation plus transfer with a perforator flap.The period from injury to secondary flap transfer ranged from 5 to 20 days (average,12 days).In this series,36 anterolateral thigh perforator flaps,5 latissimus dorsal muscular flaps and 4 lateral arm flaps were transferred.Results All the 45 free flaps survived with no deep infection or osteomyelitis.Partial necrosis happened at the distal ends of 2 latissimus dorsal muscular flaps which were cured by skin graft.Postoperative circulatory crisis happened after transfer of an anterolateral thigh perforator flap which survived with 5 cm skin necrosis at the distal end after successful surgical exploration.Superficial wound infection happened in 12 patients with no deep or bone infection.All the patients were followed up for 12 to 36 months (average,18.5 months).All the flaps were soft in texture,with varying degrees of pigmentation.The sensory recovery was S2 in 8 flaps,S3 in 29 flaps,and S4 in 8 flaps.Obvious scar hyperplasis was observed at the donor site in 5 cases while no obvious scar hyperplasis was observed in the other 40 ones.All the fractures got united after 4 to 14 months (average,8.6 months).Nonunion happened in 2 patients who were treated with autologous iliac graft 8 months after operation.By Anderson criteria,the curative efficacy was assessed as excellent in 15 cases,as good in 21,as fair in 7 and as poor in 2,yielding an excellent to good rate of 80.0%.Conclusion Early internal fixation combined with perforator flap transfe is an effective strategy for treatment of forearm open fractures with soft tissue defects of Gustilo types Ⅲ B &Ⅲ C,due to its advantages of shortened treatment period,possibility for early rehabilitation,decreased complications and satisfactory functional recovery.
6.Clinical application of anterolateral thigh flap in wound around the knee with descending genicular artery as the recipient vessel
Jun LIU ; Fengfeng LI ; Yongwei WU ; Yunhong MA ; Ming ZHOU ; Fei YIN ; Yongqiang KANG ; Yapeng WANG ; Taotao HUI ; Yongjun RUI
Chinese Journal of Microsurgery 2018;41(4):324-328
Objective To explore the clinical application of antcrolateral thigh flap transplantation in repairing wound around the knee with descending genicular artery as the recipient vessel,when anterior or posterior tibial vessel could not be utilized.Methods From January,2015 to May,2017,free anterolateral thigh flaps obtained from anastomosis of descending genicular artery and great saphenous vein were transplanted to repair the skin soft tissue defect around the knee combined with tendon and bone exposure in 7 patients,after preoperative color Doppler sonography ultrasound (CDU) for precise positioning.There were 4 males and 3 females,with the flap area ranging from 18.0 cm×8.0 cm-38.0 cm×8.0 cm.All of the donor sites were sutured directly.Postoperative followedup was done termly.Results All the patients were followed-up for 6 to 14 months,with an average of 8.9 months.Typically,2 cases had large defect areas,with distal flap necrosis of 6.0 cm and 4.0 cm,respectively,which were resected and achieved secondary skin graft healing on the residual surface.Additionally,4 cases had completely survived flaps and achieved secondary skin graft healing on the residual surface.The remaining 1 case had completely survived flap,but the distal flap near the anteromedial tibia developed bone exposure as a result of the complicated osteomyelitis.As a result,the patient received gastrocnemius myocutaneous flap to repair the wound.Conclusion Anterolateral thigh flap transplantation in repairing skin soft tissue defect wound around the knee,with descending genicular artery as the recipient vessel,can achieve satisfactory clinical efficacy,which can serve as one choice for flap repair in wound around the knee.
7.Clinical efficacy of free flap in repairing Gustilo ⅢB and ⅢC fractures of tibia and fibula combined with soft tissue defects
Yongjun RUI ; Yongwei WU ; Jun LIU ; Yunhong MA ; Fengfeng LI ; Yao LU ; Tong YANG ; Ming ZHOU ; Yongqiang KANG ; Jun GU
Chinese Journal of Trauma 2018;34(10):881-885
Objective To investigate the clinical efficacy of free flap transplantation in repairing the Gustilo type ⅢB and ⅢC fractures of tibia and fibula combined with soft tissue defects.Methods A retrospective case series study was conducted on the clinical data of 46 patients who had Gustilo type ⅢB and ⅢC fractures of tibia and fibula with soft tissue defects admitted from June 2013 to January 2017.There were 34 males and 12 females,aged 1-67 years (mean,39 years).The wound defect areas ranged from 6 cm × 20 cm to 7 cm × 38 cm.According to the Gustilo fracture classification,there were 31 cases of type ⅢB and 15 cases of type ⅢC.According to the AO fracture typing,there were five cases of type A,23 type B,and 18 type C.All patients were repaired with free flap transplantation,among which 40 patients were treated with anterolateral thigh flap and six with latissimus dorsi flap.The areas of anterolateral thigh flap ranged from 6 cm × 13 cm to 14 cm ×32 cm,and those of the latissimus dorsi flap from 6 cm × 22 cm to 7 cm × 40 cm.Efficacy was evaluated by flap survival rate,complications,fracture healing time,lower limb function scoring system (LEFS),and skin flap function.Results All limbs were salvaged successfully.One case of total flap necrosis and eight cases of postoperative crisis occurred.After active exploration and treatment,three cases were seen distal local necrosis,and the total survival rate was 91%.Infection at the donor site was found in two cases.The complication incidence rate was 4%.All patients were followed up for 7-42 months,with an average of 19 months.The fracture healing time averaged 43.5 weeks,and the LEFS score averaged 54 points.According to the seven indexes of flap function,the results were excellent in 1 1 cases,good in 29 cases,fair in four cases,and poor in two cases,with an excellent and good rate of 87%.Conclusion Free flap transplantation can achieve satisfactory efficacy in treating Gustilo type ⅢB and ⅢC of tibia and fibula combined with soft tissue defects,with high limb salvage rate and good function recovery.
8.Evaluation of Coefficients of Variation for Clinical Chemistry Tests Based on Internal Quality Control Data Across 5,425 Laboratories in China From 2013 to 2022
Wei WANG ; Zhixin ZHANG ; Chuanbao ZHANG ; Haijian ZHAO ; Shuai YUAN ; Jiali LIU ; Na DONG ; Zhiguo WANG ; Fengfeng KANG
Annals of Laboratory Medicine 2024;44(3):245-252
Background:
Clinical chemistry tests are most widely used in clinical laboratories, and diverse measurement systems for these analyses are available in China. We evaluated the imprecision of clinical chemistry measurement systems based on internal QC (IQC) data.
Methods:
IQC data for 27 general chemistry analytes were collected in February each year from 2013 to 2022. Four performance specifications were used to calculate pass rates for CVs of IQC data in 2022. Boxplots were drawn to analyze trends of CVs, and differences in CVs among different groups were assessed using the Mann–Whitney U-test or Kruskal– Wallis test.
Results:
The number of participating laboratories increased significantly from 1,777 in 2013 to 5,425 in 2022. CVs significantly decreased for all 27 analytes, except creatine kinase and lipase. Triglycerides, total bilirubin, direct bilirubin, iron, and γ-glutamyl transferase achieved pass rates > 80% for all goals. Nine analytes with pass rates < 80% based on 1/3 allowable total error were further analyzed; the results indicated that closed systems exhibited lower CVs than open systems for all analytes, except total protein. For all nine analytes, differences were significant between tertiary hospitals and non-tertiary hospitals and between accredited and non-accredited laboratories.
Conclusions
The CVs of IQC data for clinical chemistry have seen a continuous overall improvement in China. However, there is ample room for imprecision improvement for several analytes, with stricter performance specifications.
9. A nationwide multicenter study on clinical laboratory construction in China
Fengfeng KANG ; Weixing LI ; Wei WANG ; Bingquan CHEN ; Zhiguo WANG
Chinese Journal of Hospital Administration 2019;35(10):867-871
Objective:
To investigate the status of clinical laboratory construction in China and evaluate its completeness, adequacy and effectiveness.
Methods:
An electronic investigation on laboratory construction was conducted in March 2019. The questionnaires were synchronously distributed to 14 055 laboratories covering 31 provincial administrative units in China. Excel 2010 and SPSS 20 were used for analysis of four main indicators: gross area, total equipment value, human resource, and testing items. Descriptive statistics were demonstrated and comparisons of the indicators among different types of laboratories were checked with the Kruskal-Wallis test.
Results:
A total of 9 966 valid questionnaires were returned, with an effective recovery of 70.9%. The overall median of the four indicators were respectively: gross area(344.5 square meters), total equipment value(RMB 4.15 million), staff number(12) and testing item number(160). The difference of all four indicators among various types of laboratories was significant(