2.Correlation analysis of perfused lung volumes and visual scores using perfusion SPECT/CT and hemodynamic parameters in patients with chronic thromboembolic pulmonary hypertension
Peng HOU ; Siyan LIN ; Min WANG ; Penghao CHEN ; Jingwei YI ; Yuxiang LI ; Dayong HUANG ; Jielong LIN ; Fengcheng LIN ; Wenliang GUO ; Chengxin XIE ; Cheng HONG ; Xinlu WANG
Chinese Journal of Nuclear Medicine and Molecular Imaging 2021;41(2):82-87
Objective:To investigate the correlations between perfused lung volumes, visual scores (using perfusion SPECT/CT) and right-heart catheter (RHC) hemodynamic parameters in patients with chronic thromboembolic pulmonary hypertension (CTEPH).Methods:A total of 51 consecutive CTEPH patients (17 males, 34 females, age (59±12) years) in the First Affiliated Hospital of Guangzhou Medical University between March 2015 and July 2019 were retrospectively analyzed. All patients underwent lung perfusion SPECT/CT imaging and RHC examinations. Perfused lung volumes were determined using threshold-based (15%-85%) segmentation. Visual semiquantitative scoring in each lung segment was performed using Begic method. RHC hemodynamic parameters including pulmonary artery systolic pressure (PASP), pulmonary arterial diastolic pressure (PADP), mean pulmonary artery pressure (mPAP), pulmonary arteriolar wedge pressure (PAWP), pulmonary vessel resistance (PVR), cardiac output (CO), cardiac index (CI) were recorded. Spearman correlation analysis was used to evaluate the correlations between perfused lung volumes, visual scores and hemodynamic parameters.Results:There were significant correlations between perfused lung volumes (30%-70% threshold) and mPAP ( rs values: from -0.414 to -0.302, all P<0.05). Among them, perfused lung volumes under the threshold of 40% and 45% were moderately correlated with mPAP ( rs values: -0.414, -0.412, both P<0.05). Perfused lung volume (40% threshold) was moderately negatively correlated with PASP, PADP ( rs values: -0.402, -0.440, both P<0.05), and slightly negatively correlated with PVR ( rs=-0.352, P<0.05). Visual scores were slightly positively correlated with the PADP ( rs=0.311, P<0.05), while there was no correlation between visual scores and other RHC hemodynamic parameters ( rs values: from -0.201 to 0.275, all P>0.05). Conclusion:Perfused lung volumes based on threshold-based segmentation in lung perfusion SPECT/CT imaging can accurately reflect hemodynamic status and may provide useful information for severity assessment of CTEPH.
3.Treatment of anterior dislocation of sternoclavicular joint with Kirschner wire minimally invasive fixation.
Cheng PENG ; Da-chuan SUN ; Jun-guang LI ; Chen-gang HE ; Chun-lin HU
China Journal of Orthopaedics and Traumatology 2010;23(2):151-153
OBJECTIVETo investigate the safety and efficacy of close reduction and percutaneous needle fixation for the treatment of anterior dislocation of sternoclavicular joint.
METHODSA retrospective analysis was performed with 6 cases of anterior sternoclavicular dislocation by close reduction and percutaneous needle fixation with Kirschner wire treated from January 2001 to February 2009, including 5 males and 1 female aged from 19 to 45 with an average of 28.8 years old. Among the 6 cases, 4 were on right lateral and 2 were on left lateral. The time from injured to treatment was from 6 hours to 12 days (averaged 4.5 days). The clinical effects were evaluated according to Rockwood scoring and the complications were observed.
RESULTSAll 6 patients were followed-up for 3 to 13 months (averaged 6 months). According to Rockwood scoring,the preoperative score was (7.00 +/- 0.89) points, postoperative score was (13.17 +/- 1.72) points; the results showed excellent in 5 cases and good in 1 case. No local infection, postoperative pain,recurrent dislocation,broken needle, and other complications were observed in this study.
CONCLUSIONThe treatment of anterior sternoclavicular joint dislocation with Kirschner wire minimally invasive fixation is an easy, reliable fixation with less complications.
Adult ; Bone Wires ; Female ; Fracture Fixation, Internal ; methods ; Humans ; Joint Dislocations ; diagnostic imaging ; surgery ; Male ; Middle Aged ; Minimally Invasive Surgical Procedures ; methods ; Radiography ; Sternoclavicular Joint ; injuries ; surgery
4.Treatment of contracture of achilles tendon with minimally invasive achilles tendon lengthening and system rehabilitation.
Cheng PENG ; Da-Chuan SUN ; Huai HUANG ; Chun-Lin HU
China Journal of Orthopaedics and Traumatology 2012;25(1):78-79
OBJECTIVETo investigate the safety and efficacy of minimally invasive achilles tendon lengthening and system rehabilitation for the treatment of contracture of achilles tendon.
METHODSFrom January 2002 to December 2010, 27 patients (31 feet) with contracture of achilles tendon were treated with minimally invasive achilles tendon lengthening and system rehabilitation. There were 11 males and 16 females with an average age of 35.5 years (ranged 3 to 65 years). Right foot was in 13 cases, left foot was in 10 cases, both feet were in 4 cases. Course of disease was from 1 to 5 years with an average of 2.3 years. The cause of contracture included postoperative complication of tibia fractures treated with intramedullary nailing in 7 feet, sequelae of lower leg compartment syndrome in 11 feet, congenital talipes equinovarus in 13 feet (both feet in 4). Before operation, all the patients walked with limping, plantar flexion anomaly was from 15 degrees to 50 degrees with an average of 35.5 degrees. The strength of quadriceps muscle of thigh was grade V in 27 feet, grade IV in 4 feet, the strength of musculus triceps surae was grade V in 24 feet, grade IV in 7 feet.
RESULTSAll the patients were followed-up for 6-24 months with an average of 11.3 months. According to standard of Arner-Lindholm to evaluate function of ankle joint, 29 feet obtained excellent results and 2 feet good. No infection, re-rupture or re-contracture was found.
CONCLUSIONMinimally invasive achilles tendon lengthening and system rehabilitation in treating contracture of achilles tendon has advantage such as simple operation, less complication, lower recurrence rate, which is favourable for thoroughly rehabilitation of patients. But, the case in which the strength of quadriceps muscle of thigh or musculus triceps surae still less than grade III after preoperative rehabilitation care should not choose the method.
Achilles Tendon ; surgery ; Adolescent ; Adult ; Aged ; Bone Lengthening ; methods ; Child ; Child, Preschool ; Contracture ; rehabilitation ; surgery ; Female ; Humans ; Male ; Middle Aged ; Minimally Invasive Surgical Procedures ; methods
5.Analysis of influencing factors of portal vein tumor thrombus in primary liver cancer
Jing XU ; Lin TAN ; Xuewu GAO ; Jinling WANG ; Fengcheng LI
Cancer Research and Clinic 2018;30(9):610-612,616
Objective To investigate the influencing factors of portal vein tumor thrombus in patients with primary liver cancer(PLC).Methods A total of 483 patients with PLC in the Second People's Hospital of Fuyang from January 2012 to December 2016 were included in this retrospective study.Univariate analysis and multi-variate logistic regression analysis were employed to analyze the association between portal vein tumor thrombus and routine clinical parameters.Results The univariate analysis showed that alanine aminotransferase,aspartate aminotransferase,total bilirubin,γ-glutamyltranspeptidase,alkaline phosphatase,alpha-fetoprotein,the size and the number of tumors,ascites and center location of cancer performed a close relationship with the formation of portal vein tumor thrombus in patients with PLC,and the differences were statistically significant(P values were 0.010,0.000,0.010,0.000,0.001,0.000,0.000,0.004 and 0.010).Multivariate logistic regression analysis showed that potential significant predictors of portal vein tumor thrombus in patients with PLC were alpha-fetoprotein and ascites,and the differences were statistically significant(P values were 0.000 and 0.040).Conclusion PLC patients with high level of alpha-fetoprotein and ascites are easier to induce the formation of portal vein tumor thrombus.
6.Application of strontium polyphosphate with both radiopaque and osteogenic functions in calcium phosphate cement
Ziniu TANG ; Fengcheng CHU ; Kang WU ; Lin ZHANG ; Yanjie BAI ; Xiao LIN ; Huilin YANG ; Huan ZHOU ; Huiling LIU ; Lei YANG
Chinese Journal of Tissue Engineering Research 2024;28(22):3539-3547
BACKGROUND:Our previous studies found that adding barium sulfate could improve the mechanical and radiopaque properties of calcium phosphate cement.However,with the degradation of calcium phosphate,the remaining radiopaque agent is difficult to degrade,and the space-occupying and osteoclast effects at the implantation site affect the bone repair process.Therefore,it is necessary to develop a new biodegradable radiopaque material. OBJECTIVE:To discuss the radiopaque ability of bioactive degradable material strontium polyphosphate(SrPP)and its impact on the physicochemical properties and osteogenic effect of calcium phosphate cement. METHODS:(1)Calcium phosphate cement(CPC),starch modified calcium phosphate cement(CPS)and starch modified calcium phosphate cement(20%SrPP-CPN)containing SrPP(20%mass fraction of bone cement powder)were prepared respectively,and the physicochemical properties of the three groups of bone cements were characterized.(2)The three groups of bone cement extracts were co-cultured with rat bone marrow mesenchymal stem cells,respectively,to detect cell proliferation,energy metabolism,and osteogenic differentiation.(3)Bone defects with a diameter of 5 mm were made on each side of the top of the skull of 24 SD rats,and they were randomly divided into control group(without any intervention),CPC group,CPS group,and 20%SrPP-CPN group for intervention,with 6 rats in each group.Relevant tests were performed after 4 and 12 weeks of intervention. RESULTS AND CONCLUSION:(1)Compared with the other two groups of bone cement,20%SrPP-CPN had enhanced radiopaque ability,increased compressive strength and degradation rate,and prolonged curing time,and 20%SrPP-CPN could release Sr2+ stably during degradation.(2)CCK-8 assay showed that 20%SrPP-CPN did not affect the proliferation of bone marrow mesenchymal stem cells.Cell starvation test(serum-free culture)showed that 20%SrPP-CPN could promote the proliferation of bone marrow mesenchymal stem cells compared with the other two groups of bone cement.Compared with the other two groups of bone cements,20%SrPP-CPN increased adenosine triphosphate concentration in bone marrow mesenchymal stem cells.Alkaline phosphatase and alizarin red staining showed that 20%SrPP-CPN could promote osteogenic differentiation of bone marrow mesenchymal stem cells compared with the other two groups of bone cement.(3)In the rat skull defect experiment,Micro-CT scanning and histological observation(hematoxylin-eosin and Masson stainings)showed that bone cement in 20%SrPP-CPN group was significantly degraded compared with that in CPC and CPS groups,and a large number of new bone tissues were dispersed in degraded bone cement.Immunohistochemical staining showed that Runx2 protein expression was increased in 20%SrPP-CPN group compared with CPC group and CPS group(P<0.01).(4)These results show that 20%SrPP-CPN has good radiopaque ability and osteogenic properties.
7.Measuring laryngotracheal stenosis by extracting centerline based on CT 3D reconstruction.
Xiao Lin WEI ; Xiao Yu LIN ; Feng ZHAO ; Wen Wu WANG ; Hui Ying CHEN ; Wan Yun YAN ; Ji Ping SU
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2022;57(8):948-956
Objective: To compare the accuracy of the centerline extracted based on CT 3D reconstruction and conventional CT 3D reconstruction in measuring the length and degree of laryngotracheal stenosis. Methods: A retrospective analysis was performed on 35 patients with laryngotracheal stenosis (including 19 cases without tracheotomy and 16 cases with tracheotomy) treated in the Department of Otorhinolaryngology Head and Neck Surgery of the First Affiliated Hospital of Guangxi Medical University from March 2006 to March 2016, including 20 males and 15 females, whose ages ranged from 1 to 73 years, with a median age of 40.5 years. And CT data of 20 normal subjects were included in the same period, including 10 males and 10 females, whose ages ranged from 20 to 63 years, with a median age of 37.0 years. The continuous cross-sectional area of the airway perpendicular to the centerline was obtained by Mimics software. The area was compared with the discontinuous cross-sectional areas reconstructed by conventional CT 3D reconstruction software advantage workstation, also the length of cervical trachea, the length of stenosis, and the minimum airway area were compared. Multi-factor linear stepwise regression method was used to analyze the factors influencing the measuring difference between the two methods. Three patients with laryngotracheal stenosis were selected, and the measured stenosis length was compared with the surgical specimens to evaluate the accuracy of the two methods. SPSS 26.0 software was used for statistical analysis. Results: In normal people, the areas of thyroid cartilage notch, glottis, inferio thyroid cartilage margin, inferio cricoid cartilage margin, and suprasternal notch planes measured by Mimics centerline method were smaller than those measured by conventional CT 3D reconstruction (t thyroid cartilage notch=4.685, tglottis=3.791, tlower thyroid cartilage margin=5.621, tlower cricoid cartilage margin=6.312, tsuprasternal notch plane=6.436, P<0.05). And the airway length measured by Mimics centerline method from the inferior thyroid cartilage to the superior sternal notch was longer (t=9.79, P<0.001). In laryngotracheal stenosis, in the non-tracheotomy group, the minimum airway area measured by Mimics centerline method was smaller and the stenosis length was longer than those measured by the conventional CT 3D reconstruction, and the difference was statistically significant (tminimum airway area=2.562, tstenosis length=5.240, P<0.05). In the tracheotomy group, the stenosis length measured by Mimics centerline method was longer than that measured by conventional CT 3D reconstruction, and the difference was statistically significant (tstenosis length=2.854, P<0.05). Multi-factor linear regression analysis showed that different CT thickness had a statistically significant effect on the difference in the length of stenosis measured by the two methods (b=-5.370, t=-3.306, P=0.004), and different tracheal forward angle had a statistically significant effect on the difference in the minimum airway area measured by the two methods (b=-0.419, t=-2.208, P=0.04). The difference between the measured length of the Mimics centerline method and the intraoperative specimens was less than 0.5 mm. Conclusion: The centerline extracted based on CT 3D reconstruction can precisely reflect the laryngotracheal morphology and measure laryngotracheal stenosis more accurately.
Adolescent
;
Adult
;
Aged
;
Child
;
Child, Preschool
;
China
;
Constriction, Pathologic
;
Female
;
Humans
;
Imaging, Three-Dimensional
;
Infant
;
Laryngostenosis/surgery*
;
Male
;
Middle Aged
;
Retrospective Studies
;
Tomography, X-Ray Computed
;
Tracheal Stenosis/surgery*
;
Young Adult