1.Minor external fixator for open comminuted phalangeal fractures with non-transarticular.
Nan WANG ; Feng SHEN ; Li-xiang WANG
China Journal of Orthopaedics and Traumatology 2015;28(12):1121-1124
OBJECTIVETo explore therapeutic effects of minor external fixator for open comminuted phalangeal fractures with non-transarticular.
METHODSFrom January 2013 to December 2014,13 patients with open comminuted phalangeal fractures were treated by minor external fixator with non-transarticular, including 9 males and 4 females aged from 18 to 56 years old with an average of 35 years old. According to Gustilo classification, 8 cases were type II, and 5 cases were type III. The time from injury to operation ranged from 2 to 7 h averaged 5 h. Seven patients were diagnosed as phalangeal fracture, 6 patients were involved with joint surface of phalangeal, which 1 case combined with inherent nerve damage and 1 case combined with soft tissue defect repaired at stage II. The patients were fixed by plaster for 2 weeks and removal external fixtor from 6 to 8 weeks after operation and received functional exercise.
RESULTSAll patients were followed up from 3 to 12 months with an average of 7 months. One case occurred metacarpophalangeal joints stiffness. No screw breakage, inflammation occurred. Skin soft tissue recovered well and obtained bone healing, the average time of bone healing was (4.6 ± 1.0) weeks. According to TAM scoring system used by Hand Surery Association of Chinese Medical Association, 7 cases got excellent results, 4 good, 1 moderate and 1 poor.
CONCLUSIONMinor external fixator for open comminuted phalangeal fractures with non-transarticular has advantages of simple operation, good stability, and could adjust at the later stage, less damage for soft tissue periosteum, low inflammatory rate, earlier functional exercise. It is worth to be popularized and applied.
Adolescent ; Adult ; External Fixators ; Female ; Finger Phalanges ; injuries ; Fractures, Comminuted ; surgery ; Humans ; Male ; Middle Aged
2.Research Status and Application of Piezoelectric Immunosensor
Feng WANG ; Dingcheng XIANG ; Zhongming LIU
Chinese Medical Equipment Journal 2003;0(10):-
The basic principles of piezoelectric quartz crystal immunosensor are reviewed. Its characteristics and applications in biomedicine are summarized. The feasibility of its application in detecting cardiac troponin I (cTnI) is briefly analyzed. There's no need of any signs and segregation steps in the technique, so the instrument is simple and easily-operated. Besides, it has a bright application future for its merits of rapid detection and precise quantification.
3.Application of Problem-based Learning Pattern to Vascular Surgery Clinical Teaching
Xiang FENG ; Zhinong WANG ; Zaiping JING
Chinese Journal of Medical Education Research 2003;0(03):-
Problem-based learning is a student-centered teaching mode,which is based on creating question circumstances.In our clinical teaching,we put up questions based on real cases and inspire students'enthusiasm,activity and creativity.The results show the PBL can elevate students' clinical ability and also can promote teachers'capability.
4.EFFECT OF HEMOPERFUSION WITH IMMOBILIZED SPECIFIC ABSORBENT ON SEPSIS IN RATS
Yang SHAO ; Xiang WANG ; Gang FENG
Medical Journal of Chinese People's Liberation Army 1982;0(03):-
To observe the changes in hemorheology, endotoxin and TNF ? in blood after hemoperfusion(HP) with adsorbent immobilized polymyxin B (PMB) on sepsis in rats. Wistar rats were randomly divided into three groups:LPS+HP+PMB,LPS+HP and LPS. All the rats received intravenously injection of lipopolysaccharide (LPS, Escherichia coil O111:B4,1mg/kg). Plasma of the rats in the group of LPS+HP+PMB was passed through a column containing sepharose coated activated charcoal immobilized polymyxin B at the 4th hour after LPS injection. The treated plasma was transfused bak after being mixed with blood cells. In LPS+HP group, the column did not contain immobilized polymyxin B. The animals of LPS group received LPS only. Quantitative endotoxin determination in blood was done with limulus amebocyte lysate test,TNF ? of the plasma assayed with ELISA, and hemorheology parameters were also observed after hemoperfusion. In LPS+HP+PMB group, the concentration of plasma was significantly decreased after hemoperfusion, but it was still significantly higher than the baseline value, and there was a decrease of blood cell ratio after hemoperfusion. The results suggest that specific adsorbent could remove endotoxin in the circulation and improve hemorheology.
5.Not Available.
Journal of Forensic Medicine 2021;37(5):736-738
6.Experiment research of nifedipine and vitamin K3 on ureteral action potential and urine flow in rabbits.
Ming-Jiang WANG ; Xin-Jun WANG ; Gui-Xiang FENG
Chinese Journal of Applied Physiology 2007;23(1):50-65
Action Potentials
;
Animals
;
Female
;
Male
;
Nifedipine
;
pharmacology
;
Rabbits
;
Ureter
;
drug effects
;
physiology
;
Urination
;
drug effects
;
Vitamin K 3
;
pharmacology
7.Fabrication and in vitro biocompatibility of porous Ti/chitason/hydroxyapatite composite scaffold
Xiang LI ; Chendong FENG ; Lin WANG ; Chengtao WANG
Chinese Journal of Orthopaedic Trauma 2016;18(1):6-10
Objective To evaluate the feasibility of the porous titanium/chitosan/hydroxyapatite (Ti/Ch/HA) composite scaffold as a bone repair substitute.Methods Additive manufacturing (3D printing) technology was used to fabricate porous Ti scaffolds as supporting structures.Chitosan/hydroxyapatite (Ch/HA) sponge was prepared within the macro-pores of Ti scaffolds using freeze drying technology.Thus,a kind of composite porous Ti/Ch/HA scaffold with good cell affinity was obtained.Osteoblastic cells were seeded and cultured in pure porous Ti scaffolds and composite Ti/Ch/HA scaffolds for 7 days.The cellular morphology,seeding efficiency and proliferation were examined and compared between the 2 kinds of scaffolds using scanning electron microscopy (SEM) and MTT assay.Results The SEM examination showed that the macro-pores of Ti/Ch/HA scaffolds were full of the composite sponge structure of Ch/HA,with a micropore size of 50 to 200 μm.Like the pure porous Ti scaffolds,composite Ti/Ch/HA ones have a compressive strength of 168.2 to 192.6 MPa,a yielding strength of 137.1 to 154.1 MPa,and a Young's modulus of 3.21 to 4.51 GPa.After culture for 7 days,a large number of flat cells adhered onto the surface of Ti scaffolds while the cells adhering onto the Ti/Ch/HA composite scaffolds were fusiform.The seeding efficiency of osteoblastic cells in the composite Ti/Ch/HA scaffolds (73.218% ± 3.748%) was significantly higher than that in the pure porous Ti scaffolds (21.352% ±4.365%) (P <0.05);the OD value of the composite Ti/Ch/HA scaffolds (0.783 ±0.043) was significantly higher than that of the pure porous Ti scaffolds (0.382 ± 0.036) (P < 0.05).Conclusions Ti/Ch/HA composite scaffolds can match human bone in mechanical properties.Compared with pure porous Ti scaffolds,the Ti/Ch/HA composite ones are more suitable for adhesion and proliferation of osteoblasts,making them an ideal kind of bone repair substitute.
8.Influence of long-term microwave radiation on contents of amino acids and monoamines in urine of Wistar rats.
Li-feng WANG ; Xiang-jun HU ; Rui-yun PENG
Chinese Journal of Industrial Hygiene and Occupational Diseases 2010;28(6):445-448
Amino Acids
;
urine
;
Animals
;
Biogenic Monoamines
;
metabolism
;
urine
;
Male
;
Microwaves
;
Rats
;
Rats, Wistar