1.False Femoral Neck Fracture Detected during Shaft Nailing: A Mach Band Effect.
Kyu Hyun YANG ; Sungjun KIM ; Ji Do JEONG
Yonsei Medical Journal 2013;54(3):803-805
Femoral neck fractures are associated with femoral shaft fractures in 1% to 9% of cases. Undisplaced neck fractures are susceptible to displacement during shaft nailing. We report the case of a 57-year-old male patient in whom we performed standard intramedullary nailing for a femoral shaft fracture. In doing so, we identified a vertical radiolucent line at the femoral neck, which was thought to be further displacement of a hidden silent fracture or an iatrogenic fracture that developed during nail insertion. Consequently, we decided to switch to reconstructive femoral nailing. Postoperative hip imaging failed to show the femoral neck fracture that we saw in the operating room. Here, we discuss the aforementioned case and review the literature concerning this artifact.
*Artifacts
;
Femoral Fractures/diagnosis/*radiography/surgery
;
Femoral Neck Fractures/diagnosis/*radiography/surgery
;
Fracture Fixation, Intramedullary
;
Humans
;
Male
;
Middle Aged
2.Computer-assisted navigation systems for insertion of cannulated screws in femoral neck fractures: a comparison of bi-planar robot navigation with optoelectronic navigation in a Synbone hip model trial.
Jun-qiang WANG ; Chun-peng ZHAO ; Yong-gang SU ; Li ZHOU ; Lei HU ; Tian-miao WANG ; Man-yi WANG
Chinese Medical Journal 2011;124(23):3906-3911
BACKGROUNDComputer-assisted procedures have recently been introduced for navigated femoral neck screw placement. Currently there is little information available regarding accuracy and efficiency of the different navigated procedures. The aim of this study was to compare two fluoroscopic navigation tracking technologies, a novel bi-planar robot navigation and standardized optoelectronic navigation, versus standard freehand fluoroscopic insertion in a Synbone hip model.
METHODSEighteen fixed Synbone hip models were divided into 3 groups. C-arm navigated cannulated screws (AO-ASIF, diameter 7.3 mm) were inserted using freehand targeting (control group). A novel bi-planar robot system (TINAV, GD2000) and an optoelectronic system (Stryker OTS Navigation System) were used for the navigated procedures (robot group and optoelectronic group). Accuracy was measured using radiographic evaluation including the measurement of screw parallelism and decentralization, and joint penetration. To evaluate the efficiency, the number of guidewire passes, operative time and fluoroscopic images taken were noted.
RESULTSThe two computer-assisted systems provided significantly improved accuracy compared to the freehand technique. Each of the parameters, including guidewire passes and number of fluoroscopy images, was significantly lower when using the computer-assisted systems than for freehand-unguided insertion (P <0.05), but operative time was significantly shorter when using freehand-unguided insertion than for the computer-assisted systems (P <0.05). Accuracy, operative time and number of fluoroscopy images taken were similar among the two navigated groups (P >0.05), but guidewire passes in the robot group were significantly less than in the optoelectronic group (P <0.05).
CONCLUSIONSBoth bi-planar robot navigation and optoelectronic navigation were similarly accurate and have the potential to improve accuracy and reduce radiation for freehand fluoroscopic targeting for insertion of cannulated screws in femoral neck fractures. Guidewire passes in the robot group were significantly less than in the optoelectronic group. However, both navigated procedures were associated with time-consuming registration and high rates of failed matching procedures.
Bone Screws ; Femoral Neck Fractures ; surgery ; Hip ; diagnostic imaging ; surgery ; Humans ; Radiography ; Surgery, Computer-Assisted ; methods
3.Progression of a Fracture Site Impaction as a Prognostic Indicator of Impacted Femoral Neck Fracture Treated with Multiple Pinning.
Pil Whan YOON ; Young Ho SHIN ; Jeong Joon YOO ; Kang Sup YOON ; Hee Joong KIM
Clinics in Orthopedic Surgery 2012;4(1):66-71
BACKGROUND: We evaluated the clinical and radiologic results of impacted femoral neck fractures treated with multiple pinning and determined the influence of the progression of impaction at the fracture site on clinical outcome. METHODS: There were 34 patients with a mean age of 65.5 years. The mean follow-up period was 3.4 years. Progression of fracture site impaction was measured using an articulo-trochanteric distance index and the percentage decrease in the articulo-trochanteric distance index between follow-up intervals. The failure of treatment was clarified as non-union and avascular necrosis. Other characteristics of the patients, including mean waiting time for surgery, preoperative Singh index score, and body mass index, were also measured to evaluate the influence on the clinical outcome of surgery. RESULTS: There were 6 fractures which were not treated successfully (3 non-union, 8.8% and 3 avascular necrosis, 8.8%). The mean percentage decrease of the articulo-trochanteric distance index within the first 6 weeks after surgery was 4.5% in the successful group and 25.1% in the failure group (p < 0.001). There was also a significant mean percentage decrease in the articulo-trochanteric distance index between 6 weeks and 3 months (p < 0.001). CONCLUSIONS: Primary stabilization with Knowles pins for impacted femoral neck fractures had a reasonable clinical outcome with low morbidity. Despite a significant difference of a mean percentage decrease in the articulo-trochanteric distance index between the successful group and the failure group, we could not verify it as a risk factor for failure of treatment because the odds ratio was not statistically significant.
Adult
;
Aged
;
Aged, 80 and over
;
Bone Nails
;
Female
;
Femoral Neck Fractures/complications/radiography/*surgery
;
Femur Head Necrosis/etiology/radiography
;
Follow-Up Studies
;
*Fracture Fixation, Internal
;
Fractures, Ununited/radiography
;
Hip Joint/*pathology/radiography
;
Humans
;
Male
;
Middle Aged
;
Odds Ratio
;
Treatment Outcome
4.Progression of a Fracture Site Impaction as a Prognostic Indicator of Impacted Femoral Neck Fracture Treated with Multiple Pinning.
Pil Whan YOON ; Young Ho SHIN ; Jeong Joon YOO ; Kang Sup YOON ; Hee Joong KIM
Clinics in Orthopedic Surgery 2012;4(1):66-71
BACKGROUND: We evaluated the clinical and radiologic results of impacted femoral neck fractures treated with multiple pinning and determined the influence of the progression of impaction at the fracture site on clinical outcome. METHODS: There were 34 patients with a mean age of 65.5 years. The mean follow-up period was 3.4 years. Progression of fracture site impaction was measured using an articulo-trochanteric distance index and the percentage decrease in the articulo-trochanteric distance index between follow-up intervals. The failure of treatment was clarified as non-union and avascular necrosis. Other characteristics of the patients, including mean waiting time for surgery, preoperative Singh index score, and body mass index, were also measured to evaluate the influence on the clinical outcome of surgery. RESULTS: There were 6 fractures which were not treated successfully (3 non-union, 8.8% and 3 avascular necrosis, 8.8%). The mean percentage decrease of the articulo-trochanteric distance index within the first 6 weeks after surgery was 4.5% in the successful group and 25.1% in the failure group (p < 0.001). There was also a significant mean percentage decrease in the articulo-trochanteric distance index between 6 weeks and 3 months (p < 0.001). CONCLUSIONS: Primary stabilization with Knowles pins for impacted femoral neck fractures had a reasonable clinical outcome with low morbidity. Despite a significant difference of a mean percentage decrease in the articulo-trochanteric distance index between the successful group and the failure group, we could not verify it as a risk factor for failure of treatment because the odds ratio was not statistically significant.
Adult
;
Aged
;
Aged, 80 and over
;
Bone Nails
;
Female
;
Femoral Neck Fractures/complications/radiography/*surgery
;
Femur Head Necrosis/etiology/radiography
;
Follow-Up Studies
;
*Fracture Fixation, Internal
;
Fractures, Ununited/radiography
;
Hip Joint/*pathology/radiography
;
Humans
;
Male
;
Middle Aged
;
Odds Ratio
;
Treatment Outcome
5.Long-Term Follow-Up Results of a Second-Generation Cementless Femoral Prosthesis with a Collar and Straight Distal Fixation Channels.
Chang Wook HAN ; Ick Hwan YANG ; Hye Yeon LEE ; Chang Dong HAN
Yonsei Medical Journal 2012;53(1):186-192
PURPOSE: We evaluated the results of more than 10 years of follow-up of total hip arthroplasty using a second-generation cementless femoral prosthesis with a collar and straight distal fixation channels. MATERIALS AND METHODS: One hundred five patients (129 hips) who underwent surgery between 1991 and 1996 for primary total hip arthroplasty using cementless straight distal fluted femoral stems were followed for more than 10 years. Ninety-four hips in 80 patients were available for clinical and radiologic analysis. The mean age at the time of surgery was 47 years, and the mean duration of follow-up was 14.3 years. RESULTS: The mean Harris hip scores had improved from 58 points to 88 points at the time of the 10-year follow-up. Activity-related thigh pain was reported in nine hips (10%). At the last follow-up, 93 stems (99%) were biologically stable and one stem (1%) was revised because of loosening. No hip had distal diaphyseal osteolysis. Proximal femoral stress-shielding was reported in 86 hips (91%). We found no significant relationship between collar-calcar contact and thigh pain, stem fixation status, or stress-shielding. The cumulative survival of the femoral stem was 99% (95% confidence interval, 98-100%) after 10 years. CONCLUSION: The long-term results of total hip arthroplasty using a second-generation cementless femoral prosthesis with a collar and straight distal fixation channels were satisfactory; however, the high rate of proximal stress-shielding and the minimal effect of the collar indicate the need for some changes in the stem design.
Adult
;
Aged
;
Arthroplasty, Replacement, Hip/*instrumentation/*methods
;
Bone Cements
;
Female
;
Femoral Neck Fractures/radiography/*surgery
;
Femur Head Necrosis/radiography/*surgery
;
Follow-Up Studies
;
*Hip Prosthesis
;
Humans
;
Male
;
Middle Aged
;
Osteoarthritis, Hip/radiography/*surgery
;
Time Factors
;
Treatment Outcome
8.Removal of a broken guide wire entrapped in a fractured femoral neck.
Qing-hua ZHU ; Tian-wen YE ; Yong-fei GUO ; Chong-li WANG ; Ai-min CHEN
Chinese Journal of Traumatology 2013;16(4):237-239
Guide wire plays an important role in the fixation of femoral neck fracture with dynamic hip screw (DHS). Breakage of a guide wire during operation is a very rare condition. We met such a dilemma in DHS fixation of a 54-year-old male patient who sustained Garden type IV fracture of the right femoral neck. The distal end of the guide wire broke and was entrapped in the fractured femoral neck. We tried to get the broken part out by a cannulated drill. Reaming was started with the cannulated drill slowly rotating around the guide K-wire until the reamer fully contained the target under fluoroscope. A bone curette was used to get the broken wire out but failed, so we had to use the cannuated drill to dredge this bone tunnel. Finally the broken wire end was taken out, mixed with blood and bone fragments. Through the existing drilling channel, DHS fixation was easily finished. The patient had an uneventful recovery without avascular necrosis of femoral head or non-union of the fracture at one year's follow-up. A few methods can be adopted to deal with the broken guide wire. The way used in our case is less invasive but technically challenging. When the guide wire is properly positioned, this method is very practical and useful.
Bone Wires
;
adverse effects
;
Device Removal
;
Femoral Neck Fractures
;
diagnostic imaging
;
surgery
;
Fracture Fixation, Internal
;
methods
;
Humans
;
Male
;
Middle Aged
;
Radiography
9.Prosthetic replacement in treatment of subcapital femoral neck fractures in the elderly.
Xinxiang XU ; Yi LIU ; Jianguo LIU ; Yinliang LI
Chinese Journal of Traumatology 2002;5(1):28-31
OBJECTIVETo compare the results of femoral head replacement (FHR) and total hip replacement (THR) in treatment of subcapital femoral neck fractures (SFNF).
METHODSBetween May 1987 and July 1998, 56 elderly patients (6 5-90 years; average 73.5 years) with SFNF were treated with prosthetic replacement. Six cases were treated with unipolar FHR, 18 cases with Bateman bipolar FHR, and 32 cases with Bateman bipolar THR. All domestic prostheses were installed with cement.
RESULTSThere was no significant difference between the 2 groups in operating time and blood transfusion. Forty-nine patients were followed-up for an average of 5 years and 10 months. No wound infection or death was related to surgery. Complications in Group FHR were significantly higher than that i n Group THR.
CONCLUSIONSSince FHR is difficult to fit the bony acetabulum, it is only indicated for senile cases with poor conditions. However, the bi polar THR installed with cement is indicated for most elderly patients. Since th e femoral head and acetabulum can fit each other completely, it is more stable for taking weight-bearing earlier with less complications.
Aged ; Aged, 80 and over ; Arthroplasty, Replacement, Hip ; Bone Cements ; Female ; Femoral Neck Fractures ; diagnostic imaging ; surgery ; Hip Prosthesis ; Humans ; Male ; Radiography ; Treatment Outcome
10.The Targon FN System for the Management of Intracapsular Neck of Femur Fractures: Minimum 2-Year Experience and Outcome in an Independent Hospital.
Donald OSARUMWENSE ; Elizabeth TISSINGH ; Kakra WARTENBERG ; Saurabh AGGARWAL ; Fikry ISMAIL ; Sam ORAKWE ; Farid KHAN
Clinics in Orthopedic Surgery 2015;7(1):22-28
BACKGROUND: The Targon FN implant was developed in 2007 to treat intracapsular neck of femur fractures. Early results from the design centre have shown good results in terms of fracture complications. We wished to see if these results can be reproduced in an independent institution. METHODS: The records of consecutive patients, treated with this implant between 2008 and 2011 at Queen Elizabeth Hospital, were identified and collected for this study. Operations were performed by all grades of surgeons under supervision as appropriate. These patients went on to have both clinical and radiological assessment for fracture healing and function. RESULTS: Fifty-one patients were identified with 43 patients available for final follow-up. The average age was 66 years with a minimum follow-up of 24 months. A non-union rate of 0% in the undisplaced fracture group and 1 in 12 (8%) in the displaced fracture group was observed. An avascular necrosis rate of 6% and 8% was observed for undisplaced and displaced fracture types, respectively. No significant change in premorbid to postoperative ambulation was observed and there was no wound complication. CONCLUSIONS: Our study shows similar results with those of the design centre and which are superior to those currently found in the literature for the more traditional fixation methods. It also shows that the promising results with this new implant as seen from the design institutions can be reproduced by all cadres of surgeons in non-specialist practice.
Adult
;
Aged
;
Aged, 80 and over
;
*Bone Plates
;
Bone Screws
;
Female
;
Femoral Neck Fractures/radiography/*surgery
;
Follow-Up Studies
;
Fracture Fixation, Internal/*instrumentation/methods
;
Humans
;
Male
;
Middle Aged
;
Prosthesis Design
;
Retrospective Studies
;
Young Adult