1.Contrast-enhanced ultrasonography of hepatocellular carcinoma: correlation between quantitative parameters and arteries in neoangiogenesis
Xiaoqing PEI ; Longzhong LIU ; Feifei ZUO ; Wei ZHENG ; Yuhong LI ; Feng HAN ; Anhua LI
Chinese Journal of Ultrasonography 2011;20(3):222-225
Objective To explore the relationships between the quantitative parameters for contrastenhanced ultrasonography(CEUS) in hepatocellular carcinoma (HCC) and arteries in neoangiogenesis.Methods One hundred and fifteen HCCs in CEUS were analyzed off-line with dynamic vascular curve of ImageArena and immunohistochemical stained in the tissue slices.Parameters including maximum of intensity(IMAX),rise time(RT),time to peak(TTP),mean trasit time corresponding to the center of gravity(mTT) ,rise slope(RS) and washout time(WT) were analyzed by statistics.Unpaired arteries(UAs)of 82 HCC cases were succesfully stained.Results The number of UAs had moderate correlation with RT (r = - 0.446),TTP (r = - 0.432) and RS (r = 0.431) (P < 0.05),and it had mild correlation with IMAX (r = 0.303) ,WT (r = 0.285) (P <0.05).Conclusions Neoangiogenesis is a functional adaptation to altered vascular dynamics.Quantitative parameters of CEUS,reflecting hemodynamics of tumors,are correlated with UAs.
2.Comparison of rheologic properties between Ca-alginate hydrogel microspheres suspension and whole blood.
Pei XU ; Xiang WANG ; Yaojin LI ; Feifei WANG ; Ming DUAN ; Li YANG
Journal of Biomedical Engineering 2013;30(1):100-104
Starting from the form of red blood cells and the hematocrit (Hct, about 45 vol% of whole blood), we tried to prepare a kind of microspheres suspension to imitate non-Newtonian fluid property of whole blood, exploring its potentiality to be applied in blood viscosity quality control substance. In our study, we produced Ca-alginate hydrogel microspheres using emulsion polymerization, then we suspended the microspheres in 0.9 wt% NaCl solution to obtain a kind of liquid sample with the microspheres taking 45% volume. Then we used two types of viscometers to measure and analyse the changes of sample viscosity at different shear rate. We observed the forms of Ca-alginate hydrogel microspheres with microscope, and found them to be relatively complete, and their diameters to be normally distributed. Diameters of about 90% of the microspheres were distributed in a range from 6 to 22 micron. The samples were examined with viscometer FASCO-3010 and LG-R-80c respectively, both of which have shown a shear-thinning effect. After 5-week stability test, the CV of viscosity results corresponding to the two instruments were 7.3% to 13.8% and 8.9% to 14.2%, respectively. Although some differences existed among the results under the same shear rate, the general variation trends of the corresponding results were consistent, so the sample had the potentiality to be widely used in calibrating a different type of blood viscometer.
Alginates
;
chemistry
;
Blood Viscosity
;
Calcium
;
chemistry
;
Glucuronic Acid
;
chemistry
;
Hexuronic Acids
;
chemistry
;
Humans
;
Hydrogel, Polyethylene Glycol Dimethacrylate
;
chemistry
;
Microspheres
;
Plasma Substitutes
;
chemistry
;
Rheology
;
instrumentation
;
Suspensions
;
chemistry
3.Study on preparation and property of a new adsorbent for endotoxin removal in blood purification.
Feifei WANG ; Xiang WANG ; Yanlian XIONG ; Pei XU ; Xinxin JIN ; Jinlong TANG ; Jinchun MAO
Journal of Biomedical Engineering 2013;30(3):635-640
In order to remove the endotoxin from the blood of endotoxemia patients, we prepared a new adsorbent with heparin space arm and polymyxin B (PMB) ligand. The carrier of chloromethyl polystyrene resin was activated and heparin space arm was grafted, and then PMB ligand was immobilized onto adsorbent with glutaraldehyde. We employed in vitro FITC-lipopolysaccharide (FITC-LPS) static adsorption to characterize the adsorption properties on the adsorbent, and conducted in vitro lipopolysaccharide (LPS) static adsorption to measure quantitavely the adsorption capacity and rate, and then evaluated the blood compatibility. The in vitro static adsorption indicated that the adsorbent had the removal rate of LPS above 70% with the adsorption equilibrium time for 2 hours. Blood compatibility experiment showed that the adsorbent had little negative effects on blood cells and plasma protein, and their adsorption rates were less than 10% for hemocytes and 20% for plasma protein respectively. This adsorbent exhibited high selectivity, high adsorption capacity and good biocompatibility, and presented a promising clinical application in the treatment of endotoxemia.
Adsorption
;
Endotoxemia
;
therapy
;
Endotoxins
;
isolation & purification
;
Hemofiltration
;
instrumentation
;
methods
;
Heparin
;
chemistry
;
Humans
;
Ion Exchange Resins
;
chemistry
;
Ligands
;
Polymyxin B
;
chemistry
;
Sorption Detoxification
;
methods
4.Research on the management effect of information nurse in sterilization supply center in new surgical instruments
Ruifang HUA ; Ying LIU ; Chunli DU ; Feifei PEI ; Xiaoli LI ; Yi SU
Chinese Journal of Practical Nursing 2023;39(26):2001-2006
Objective:To explore the management effect of information nurses in the reception of new surgical instruments and to provide a reference for improving the quality of instrument management in central sterile supply department.Methods:This was a quasi-experimental study. A total of 45 packages of 227 pieces received from January to July 2021 in central sterile supply department of the First Affiliated Hospital of Zhengzhou University were selected as the control group by convenience sampling method, and the conventional mode was used to receive new surgical instruments. Another 51 packages of 259 pieces received from November 2021 to June 2022 were selected as the observation group, and the information nurse management system was set up to receive new surgical instruments. The observation and comparison of the time to complete the receipt of new surgical instruments in central sterile supply department, the incidence of adverse events in the operation process and the satisfaction of medical and nursing staff with the management of new surgical instruments were conducted.Results:The receiving time for newly added surgical instruments of the observation group was 6.00(5.00, 8.00) hours and that of the control group was 28.00(20.00, 42.50) hours, with a statistically significant difference between the two groups ( Z = - 8.26, P<0.01). The incidence of adverse events of new surgical instruments was 0.4%(1/259) in the observation group and 6.2%(14/227) in the control group, there was significant difference between the two groups ( χ2 = 13.52, P<0.01). The satisfaction degree of medical staff in the observation group was 100% (50/50), higher than 72% (36/50) in the control group, and the difference between the two groups was statistically significant ( χ2 = 16.28, P<0.01). Conclusions:The implementation of the post of information nurse in the special post responsibility system in the management of new surgical instruments can effectively manage the specifications of surgical instruments, reduce the receiving time and the occurrence of adverse events, improve the satisfaction of medical staff.
5.Expression level of SET gene in acute myeloid leukemia and its clinical significance.
Peipei YE ; Mengxia YU ; Qitian MU ; Feifei CHEN ; Renzhi PEI ; Zhimei CHEN ; Jiyu LOU ; Wenbin QIAN ; Haitao MENG ; Hongyan TONG ; Wenyuan MAI ; Huanping WANG ; Jie JIN ;
Chinese Journal of Hematology 2014;35(5):397-402
OBJECTIVETo investigate the expression level of SET gene in patients with acute myeloid leukemia (AML) and evaluate its significance.
METHODSThe expression level of SET gene in 141 de novo AML patients was determined by real time quantitative PCR (RQ-PCR), and its relationship with the clinical features and outcomes of these patients were analyzed.
RESULTSSET gene transcript level was detected in 141 AML patients with the median expression level of 0.86(range 0.02-15.69). AML patients with higher SET gene expression had a higher level of white blood cell (WBC ≥ 100 × 10⁹/L) count than of lower SET gene expression ones (31.0% vs 11.4%, P=0.005). In the 136 patients who received treatment after diagnosis, higher SET gene expression group had lower complete remission rate (50.0%) than of lower expression cohort (73.5%) after two cycles of chemotherapy (P=0.005). Survival analysis showed that patients with higher SET gene expression had significantly shorter overall survival(OS) (10 months vs 22 months, P=0.001) and event-free survival (EFS) (2 months vs 14 months, P=0.005) than of lower SET gene expression ones. Multivariate COX regression analysis showed SET overexpression was an independent prognostic factor for OS. In the patients with the normal karyotype, higher SET expression group also had significantly shorter OS (12 months vs 35 months, P=0.010) and EFS (4 months vs 14 months, P=0.026) than of lower SET expression ones.
CONCLUSIONHigh expression of SET gene was associated with poor prognosis and might be a prognostic molecular marker of AML.
Disease-Free Survival ; Gene Expression Regulation, Neoplastic ; Histone Chaperones ; genetics ; Humans ; Leukemia, Myeloid, Acute ; genetics ; Prognosis ; Remission Induction ; Transcription Factors ; genetics
6.Application of B-ultrasound-guided transabdominal villus and amniocentesis in prenatal diagnosis of thalassemia
Lanlan ZHANG ; Fenfang HUANG ; Feifei GONG ; Haiyan CAI ; Xuemei HU ; Yanhua HUANG ; Pei LIANG ; Yijuan CHEN
China Modern Doctor 2024;62(3):13-15
Objective To explore the clinical application of ultrasound-guided transabdominal villus and amniocentesis in the prenatal diagnosis of thalassemia,and to find a suitable method for the prenatal diagnosis of thalassemia in Qinzhou.Methods A total of 531 high-risk pregnant women with severe or intermediate thalassemia during single pregnancy who were treated in the Department of Medical Genetics and Prenatal Diagnosis,Qinzhou Maternal and Child Health Hospital from March 2021 to April 2022 were selected for the study.According to different sampling methods,they were divided into control group(amniocentesis,n=415)and study group(transabdominal villus puncture,n=116).The success rate,complication rate of the two groups were compared.Results The success rate of puncture in the control group was 100%,2 cases were aborted within 2 weeks after surgery,17 cases were diagnosed with severe alpha-thalassemia,10 cases with severe β-thalassemia and 64 cases with intermediate thalassemia,48 cases with moderate and severe thalassemia induced labor.The success rate of puncture in the research group was 100%,10 cases were diagnosed with severe alpha-thalassemia,4 cases with severe β-thalassemia and 17 cases with intermediate thalassemia,and 26 cases with moderate severe thalassemia were induced labor.There was no significant difference in puncture success rate and abortion rate between the two methods(P>0.05).Conclusion Both methods are safe and effective.Transabdominal villus sampling can detect fetal thalassemia in early pregnancy,and it is worth promoting and applying in clinical practice.