1.Bibliometric analysis on research hot and trends on neural stem cells
Feifei GE ; Xinying AN ; Jiaxue HUANG ; Hui CHI
Chinese Journal of Neurology 2012;(12):888-892
Objective To analyze international research status and research focus of neural stem cells.Methods Using bibliometric analysis,the paper analyzed the international neural stem cells research documents in web of science database by analysis tools such as Thomson Data Analyzer.Research status on neural stem cells was analyzed including the distributions of years,countries,institutions and currently hot topics of international research on neural stem cells were emphatically analyzed.Results Researches on neural stem cells have developed rapidly in the recent 10 years.Main research countries include the America,China,Japan,and European Union etc.The key research topics in the field of international neural stem cells included neural stem cells proliferation,differentiation,gene transcription,gene expression in basic research and research on neural stem cells transplantation therapy including Parkinson' s disease,spinal cord injuries,stroke,Alzheimer disease,Huntington disease etc.Conclusions Neural stem cells research has become a hot topic for international researchers,and inspiriting progress has been made.There are still many issues that need to he further explored.
2.Application of Z-form plasty with a nasal mucous membrane and alar cartilage flap to repair severe secondary nasal deformity after cleft lip operation
Shuxing GE ; Feifei SHI ; Baoshan SUN
Chinese Journal of Medical Aesthetics and Cosmetology 2008;14(2):73-75
Objective To investigate a repair method for unilateral complete cleft lip nasal deformities.Methods Based on the fullness of healthy nasal wing,Z-form plasty was designed with a nasal mucous membrane and alar cartilage flap,to prolong its curtate length of the deformed side through overlapping transposition,and then with suspension of the custom-crafted nasal wing to replace its abnormal structure,subsequently,to recover the normal anatomic structure of the nosewing,and to get the nasal deformity repaired.Results A total of 12 patients with the severe nasal deformity were treated by this method.and all had satisfactory results.Conclusion This technique is a good choice for repairing the severe secondary nasal deformity after single complete cleft lip operation.
3.Feasibility of reducing artifacts of spine metal implants at 3.0 T MRI
Feifei GAO ; Yi WEI ; Shufang WEI ; Xiaojing KAN ; Yinghui GE
Chinese Journal of Radiology 2017;51(7):519-524
Objective To investigate the feasibility of reducing spine metal artifacts with metal artifacts reduction technique (WARP) at 3.0 T MRI.Methods This study included 15 cervical and 14 lumbar spine cases.The image quality of WARP sequences and conventional sequences were compared (5 score evaluation scale) as well as the signal to noise ratio (SNR) and contrast noise ratio (CNR) of the image artifacts.The scanning time was recorded.Paired-t test and Mann-Whitney test were used respectively to compare the SNR and CNR,and qualitative scoring between the two sequences.P<0.05 was considered to indicate a significant difference.Results The image distortion and blur of the WARP sequences were obviously reduced as compared to the conventional sequences.The SNR and CNR of artifacts of the WARP sequences were lower than that of the conventional sequences (All P<0.05).The image quality scores of WARP sequences in cervical and lumbar spines[4(3 to 5) and 4(3 to 5)] were higher than that of conventional sequences[3(2 to 4),3(2 to 4)](P<0.05).The scanning time of cervical spines in WARP sequence(14 min 9 s) was increased by 64 s (8.2%),and the time of lumbar spines (13 min 41 s) decreased by 9 s (1.1%).Conclusion The WARP sequences at 3.0 T could effectively reduce the artifacts of metallic prosthesis in cervical and lumbar spine without prolonging the scanning time at 3.0 T MRI.
4.Effect on threshold of triggered angiographic acquisition of renal artery CTA by different iodine flow rate
Xiaojing KAN ; Ying GUO ; Shufang WEI ; Feifei GAO ; Pengming WANG ; Yinghui GE
Chinese Journal of Medical Imaging Technology 2017;33(7):1076-1079
Objective To evaluate the effect on threshold of triggered angiographic acquisition by different iodine flow rate on renal artery CTA using Smart Prep tracking technique.Methods A total of 420 patients were randomly divided into A-D group with iodine flow rate of 0.90 gI/s,1.11 gI/s,1.20 gI/s,1.48 gI/s on average respectively.And each group were divided 7 subgroups with threshold 140-<150 HU,150-< 160 HU,160-< 170 HU,170 <180 HU,180 <190 HU,190-<200 HU,200-210 HU respectively.The quality of the images were graded from 1 5 by 2 radiologists.The best image quality subgroups were achieved,and the scores were compared among the best image quality subgroups.Results Image quality of renal CTA in each group were best performed with a threshold of 170-< 190 HU,160-< 190 HU,170-< 180 HU,160-< 180 HU respectively.When the threshold were 170-<180 HU,image quality were good with all iodine flow rate groups.There was no significant difference among the scores of the best image quality subgroups (all P>0.05).Conclusion Different iodine flow rate with appropriate threshold can acquire better image quality of renal CTA.
5.A study of the correlation between dental trauma and the personality of school-aged children
Feifei GUO ; Xinxin LAI ; Zhifei ZHOU ; Yujiang CHEN ; Xin GE ; Xiaojing WANG
Journal of Practical Stomatology 2019;35(1):51-54
Objective: To study the influence of personality on the occurrence of dental trauma of school-aged children. Methods:The school-aged children with dental trauma who came to visit our department were randomly recruited. The Eysenck Personality Scale was used to test the subjects who met the inclusion criteria. Results: 306 children were included in the study. There was a statistically significant association between personality type and the number of traumatic teeth (P < 0. 05) and the number of traumatic teeth in children with extroversion was higher than that of children with neutrality or introversion (P < 0. 05) . Conclusion: Extroverted personality is a significant correlation factor affecting the severity of dental trauma in children, and it is of great significance to provide scientific guidance and warning for them to prevent tooth trauma.
6.CT spectral imaging assessment of synovial hemosiderin deposition in knee joint in patients with hemophilic arthropathy
Shufang WEI ; Minghua SUN ; Feifei GAO ; Huina LIU ; Pingchong LEI ; Yinghui GE
Chinese Journal of Medical Imaging Technology 2018;34(6):924-928
Objective To observe the value of CT spectral imaging in assessment of synovial hemosiderin deposition (SHD) in the knee joint in patients with hemophilic arthropathy (HA).Methods Twenty-five HA patients (40 assessable knees) underwent CT spectral imaging and MR scanning.According to the MRI international prophylaxis study group (IPSG) score of SHD,the knees were divided into mild group and severe group.CT value,iron (water) concentration (FeC),water (iron) concentration (WC),effective atomic number (Eff-Z) and average spectral curve slope (aSCS) of SHD area were measured and calculated,respectively.Meanwhile,the adjacent semi-membrane muscles in the same slice were taken as controls.The spectral parameters of CT were compared with One-Way ANOVA,and ROC curves were plotted to obtain the spectral parameters and the optical diagnostic threshold of SHD.Results CT value,FeC,and aSCS of SHD area were statistically significant among three groups (F=148.08,307.88,7.80,364.62 and 261.50,P<0.01),and the differences of parameters between any two groups except WC were statistically significant (all P<0.05).The area under ROC curve of SHD evaluated with aSCS was the largest,and the thresholds for the diagnosis of severe and mild SHD of aSCS was 1.84 and 0.42,respectively.Conclusion Multiple parameter analysis of CT spectral imaging is of great value for assessment of the severity of SHD in the knee joint in HA patients,therefore having important clinical significance.
7.The assessment of imaging diagnosis of brucellar spondylitis
Huina LIU ; Feifei GAO ; Shufang WEI ; Yuxia ZHANG ; Tianming CHENG ; Yinghui GE
Chinese Journal of Radiology 2019;53(1):40-45
Objective To explore the imaging features of brucellar spondylitis (BS).Methods The imaging data of 49 cases who were diagnosed as brucellar spondylitis by a positive standard tube agglutination titer test (≥1:100) and (or) the isolation of brucella species from blood or other tissue at our institution between September 2012 and October 2016 were retrospectively reviewed.X-ray,CT scan and MRI examination was performed in 49,28 and 42 cases,respectively,of which 19 cases underwent both CT scan and MRI examination.The imaging manifestations of the spine were analyzed.The x2 test or Fisher's exact test were applied to compare the imaging manifestations of the patients who underwent both CT scan and MRI examination.Results Of the 49 patients,34 patients (69.4%) had involvement of the lumbar vertebra.Forty-five patients (91.8%) had contiguous involvement at adjacent 2 vertebral bodies.There were 10 cases (20.4%) with bony spur or bone bridge,3 cases (6.1%) with spondylolisthesis and 3 cases (6.1%)with slightly kyphosis deformity.There were 8 cases (28.6%) showing bone destruction of more than half of the vertebral body and 6 cases (21.4%) with sequestra on CT.There were 14 cases (33.3%) with psoas abscesses,of which 2 (4.8%) had migrating abscess.Epidural abscesses with dural sac compression were found in 17 cases (40.5%) and 3 cases (7.1%) showed nerve roots compression.There were statistically significant differences in the detection of vertebral bone destruction,bone marrow edema,hyperosteogeny,intervertebral disc changes,abscess formation and sequestrum between CT and MRI (P<0.05).Conclusion BS has characteristic imaging features.The presence of bone destruction,sequestrum,and migrating abscess should warrant the possibility of BS.
8.Improved ability of demonstrating ocular masses on 3.0 T MR scanner using PROPELLER: a multi-center study
Hong JIANG ; Guanghui BAI ; Qinghe HAN ; Meiyun WANG ; Feifei WANG ; Bocheng WANG ; Shijun WANG ; Huaizhi GE ; Qinghai YUAN ; Chuanliang CHEN ; Jingliang CHENG ; Xiaofeng TAO ; Junfang XIAN
Chinese Journal of Radiology 2022;56(9):989-995
Objective:To investigate the value of periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) in improving ability of demonstrating ocular masses on 3.0 T MR scanner.Methods:This study was a multi-center prospective study involving 6 centers. From July 2018 to January 2020, totally 413 patients with ocular masses from 6 centers were prospectively enrolled, and all of them underwent T 1WI and T 2WI, PROPELLER T 1 FLAIR and T 2WI, and contrast-enhanced scans. The signal intensity of eyelid, vitreous body, lacrimal gland, intraorbital segment of optic nerve, and orbital masses of eyelid, intraocular, lacrimal gland and retrobulbar were measured by two radiologists, and the signal to noise ratio (SNR) and contrast noise ratio (CNR) were calculated. The 5-point scoring method was used to evaluate the motion artefacts, tumor edges and the relationship between the tumor and adjacent structures, and the overall score of image quality was calculated. Paired t-test or Wilcoxon signed rank test was used to compare the image quality between PROPELLER and non-PROPELLER images. Results:The SNR and CNR of PROPELLER T 2WI were higher than those of non-PROPELLER T 2WI (all P<0.001). The SNR and CNR of PROPELLER T 1 FLAIR were lower than those of non-PROPELLER T 1WI (all P<0.05). The scores of artefacts and overall image quality in PROPELLER images were higher than those in non-PROPELLER images (all P<0.001). The tumor edge and the relationship between the tumor and adjacent structures scores of eyelid, intraocular, and lacrimal gland masses in PROPELLER images were higher than those in non-PROPELLER images (all P<0.001),while compared to non-PROPELLER images, retro-global masses in PROPELLER images showed no significant differences (all P>0.05). Conclusion:PROPELLER can reduce ocular motion artefacts, effectively improve image quality and ability of demonstrating anterior (eyelid, intraocular, and lacrimal gland) masses.
9.Improved ability of demonstrating ocular masses on 3.0 T MR scanner combined with an 8-channel eye surface phased array coil: a multi-center study
Shijun WANG ; Hong JIANG ; Feifei WANG ; Meiyun WANG ; Guanghui BAI ; Qinghe HAN ; Bocheng WANG ; Jingliang CHENG ; Chuanliang CHEN ; Huaizhi GE ; Qinghai YUAN ; Xiaofeng TAO ; Junfang XIAN
Chinese Journal of Radiology 2023;57(1):41-47
Objective:To investigate the value of the 8-channel eye surface phased array coil in improving image quality and demonstrating ocular masses on 3.0 T MR scanner.Methods:From July 2018 to January 2020, the data of orbital MRI in 692 patients with ocular masses on 6 medical centers were prospectively collected. The patients were simple randomly assigned into 8-channel eye surface phased array coil group (413 patients) or 8-channel head phased array coil group (279 patients), with the same MRI sequences. The signal to noise ratio (SNR) and contrast to noise ratio (CNR) were calculated in orbital anatomy structures and masses (eyelid mass, intraocular mass, lacrimal mass and orbital mass). The image quality scores including motion artifact, mass margin, the relationship between the mass and adjacent structures, and overall image quality were recorded. The differences of image quality between the two groups were compared by two independent sample t-test or Wilcoxon rank test. Results:The SNR and CNR were higher in eye surface coil group than those in head coil group ( P<0.05). The scores of ocular movement artifacts were higher in head coil group than those in surface coil group ( P<0.05). The scores of intraocular mass margin, the relationship between the mass and adjacent structures, and overall image quality were higher in surface coil group than those in head coil group ( P<0.001). There were no significant differences in mass margin, the relationship between the mass and adjacent structures, and overall image quality scores of eyelid, lacrimal gland, and orbital mass between the two groups ( P>0.05). Conclusion:3.0 T MR scanner combined with the 8-channel eye surface phased array coil can improve the SNR and CNR of orbital MR images, the demonstration of the intraocular mass margin and the relationship between the mass and adjacent structures.
10. Effect of hydrogen-rich saline on the CD4+ CD25+ Foxp3+ Treg cells of allergic rhinitis guinea pigs model
Feifei XU ; Shaoqing YU ; Chuanliang ZHAO ; Na CHE ; Ling JIN ; Qiuli WANG ; Rongming GE
Chinese Journal of Otorhinolaryngology Head and Neck Surgery 2017;52(7):506-511
Objective:
To explore the effect of hydrogen-rich saline on the CD4+ CD25+ Foxp3+ Treg cells in a guinea pig model of allergic rhinitis (AR) and investigate the underling anti-inflammatory mechanism.
Methods:
Using random number table, eighteen guinea pigs were divided into three groups (control group/AR group/HRS group,