1.Is Easier the Better in a Feasibility Study of Questionnaires?.
Journal of Neurogastroenterology and Motility 2013;19(1):3-4
No abstract available.
Feasibility Studies
2.Development of Quality Assessment Tool and Application to Customer-Oriented Hospital Foodservice Management.
Hae Young LEE ; Seung Hee CHANG ; Il Sun YANG
The Korean Journal of Nutrition 2004;37(4):329-338
The purposes of this study were to : a) develop the quality assessment tool of hospital foodservice management, b) evaluate the S hospital's foodservice quality by this tool, and c) do the feasibility study about this tool in hospital foodservice field by establishing quality management strategies. The developed quality assessment tool of hospital foodservice management was consisted of 20 items for quality evaluation by Likert 5 point scale and two additional questions with the most satisfactory item and the most unsatisfactory item. As a result of evaluation, S hospital's foodservice quality was somewhat high, on the factor 'personnel attitude', especially. The IPA technique proved nine items including Q5, Q7, Q8, Q11, Q12, Q13, Q15, Q16, Q17 were in 'Doing Great, Keep It Up' and seven items such as Q1, Q2, Q3, Q6, Q9, Q18, Q19 that got high expectation and low perception needed to be focused in quality management strategy.
Feasibility Studies
3.Feasibility Study of the Real-Time IMRT Dosimetry Using a Scintillation Screen.
Sang Wook LIM ; Byong Yong YI ; Young Eun KO ; Young Hoon JI ; Jong Hoon KIM ; Seung Do AHN ; Sang Wook LEE ; Seong Soo SHIN ; Soo Il KWON ; Eun Kyoung CHOI
The Journal of the Korean Society for Therapeutic Radiology and Oncology 2004;22(1):64-68
PURPOSE: To study the feasibility of verifying real-time 2-D dose distribution measurement system with the scintillation screen for the quality assurance. MATERIALS AND METHODS: The water phantom consisted of a scintillation screen (LANEX fast screen, Kodak, USA) that was axially located in the middle of an acrylic cylinder with a diameter of 25 cm. The charge-coupled device (CCD) camera was attached to the phantom in order to capture the visible light from the scintillation screen. To observe the dose distribution in real time, the intensity of the light from the scintillator was converted to a dosage. The isodose contours of the calculations from RTP and those of the measurements using the scintillation screen were compared for the arc therapy and the intensity modulated radiation therapy (IMRT). RESULTS: The kernel, expressed as a multiplication of two error functions, was obtained in order to correct the sensitivity of the CCD of the camera and the scintillation screen. When comparing the calculated isodose and measured isodose, a discrepancy of less than 8 mm in the high dose region was observed. CONCLUSIONS: Using the 2-D dosimetry system, the relationship between the light and the dosage could be found, and real-time verification of the dose distribution was feasible.
Feasibility Studies*
;
Light
;
Water
4.How Can We Develop and Make Use of the Quality Assessment Tool of Web-Based Instruction(WBI) for Nutrition Education?.
Hae Young LEE ; Il Sun YANG ; Yeo Hwa KANG ; Hye Young KIM
The Korean Journal of Nutrition 2004;37(4):310-315
The purposes of this study were to: a) develop the quality assessment tool of Web-based Instruction (WBI) for nutrition education, b) evaluate the operated WBI (NutriZone) by this tool, and c) do the feasibility study about quality assessment tool for WBI by establishing the instruction and operating strategies. The developed quality assessment tool of WBI for nutrition education was divided into three categories of instructional design, contents and support & operation. And a total of forty items were measured by Likert 5 point scale, computed as one point per item, and amounted to forty points in all. As a result of evaluation, NutriZone got 21.79 out of 40 points and fulfillment rate of 54.5%. The IPA (Importance-Performance Analysis) was applied to establish the instruction and operating strategies, and nine items characterized as attractiveness, multimedia, and learner-initiative were in 'Doing Great, Keep It Up', and so it was regarded as program designed with concern in WBI's characteristics unlike the conventional face-to-face education. But twelve items such as 'Errors on switch to other screens are few.', 'Ready correction leads to be out of systemic error.', 'Highlight marks and moving pictures were used in sign of importance.' and etc. that got high importance and low performance needed to be focused in instructional strategy.
Education*
;
Feasibility Studies
;
Multimedia
5.Conceptual Source Design and Dosimetric Feasibility Study for Intravascular Treatment: A Proposal for Intensity Modulated Brachytherapy.
Siyong KIM ; Eunyoung HAN ; Jatinder R PALTA ; Sung W HA
The Journal of the Korean Society for Therapeutic Radiology and Oncology 2003;21(2):158-166
PURPOSE: To propose a conceptual design of a novel source for intensity modulated brachytherapy. MATERIALS AND METHODS: The source design incorporates both radioactive and shielding materials (stainless steel or tungsten), to provide an asymmetric dose intensity in the azimuthal direction. The intensity modulated intravascular brachytherapy was performed by combining a series of dwell positions and times, distributed along the azimuthal coordinates. Two simple designs for the beta-emitting sources, with similar physical dimensions to a 90Sr/Y Novoste Beat-Cath source, were considered in the dosimetric feasibility study. In the first design, the radioactive and materials each occupy half of the cylinder and in the second, the radioactive material occupies only a quater of the cylinder. The radial and azimuthal dose distributions around each source were calculated using the MCNP Monte Carlo code. RESULTS: The preliminary hypothetical simulation and optimization results demonstrated the 87% difference between the maximum and minimum doses to the lumen wall, due to off-centering of the radiation source, could be reduced to less than 7% by optimizing the azimuthal dwell positions and times of the partially shielded intravascular brachytherapy sources. CONCLUSION: The novel brachytherapy source design, and conceptual source delivery system, proposed in this study show promising dosimetric characteristics for the realization of intensity modulated brachytherapy in intravascular treatment. Further development of this concept will center on building a delivery system that can precisely control the angular motion of a radiation source in a small-diameter catheter.
Brachytherapy*
;
Catheters
;
Feasibility Studies*
;
Steel
6.Real-time Body Surface Motion Tracking using the Couch Based Computer-controlled Motion Phantom (CBMP) and Ultrasonic Sensor: A Feasibility Study.
Suk LEE ; Dae Sik YANG ; Young Je PARK ; Dongho SHIN ; Hyun Do HUH ; Sang Hoon LEE ; Sam Ju CHO ; Sangwook LIM ; Jisun JANG ; Kwang Hwan CHO ; Hun Joo SHIN ; Chul Yong KIM
Korean Journal of Medical Physics 2007;18(1):27-34
Respiration gating radiotherapy technique developed in consideration of the movement of body surface and internal organs during respiration, is categorized into the method of analyzing the respiratory volume for data processing and that of keeping track of fiducial landmark or dermatologic markers based on radiography. However, since these methods require high-priced equipments for treatment and are used for the specific radiotherapy. Therefore, we should develop new essential method whilst ruling out the possible problems. This study aims to obtain body surface motion by using the couch based computer-controlled motion phantom (CBMP) and US sensor, and to develop respiration gating techniques that can adjust patients' beds by using opposite values of the data obtained. The CBMP made to measure body surface motion is composed of a BS II microprocessor, sensor, host computer and stepping motor etc. And the program to control and operate it was developed. After the CBMP was adjusted by entering random movement data, and the phantom movements were acquired using the sensors, the two data were compared and analyzed. And then, after the movements by respiration were acquired by using a rabbit, the real-time respiration gating techniques were drawn by operating the phantom with the opposite values of the data. The result of analyzing the acquisition-correction delay time for the data value shows that the data value coincided within 1% and that the acquisition-correction delay time was obtained real-time (2.34 x 10(-4) sec). And the movement was the maximum movement was 6 mm in Z direction, in which the respiratory cycle was 2.9 seconds. This study successfully confirms the clinical application possibility of respiration gating techniques by using a CBMP and sensor.
Feasibility Studies*
;
Microcomputers
;
Radiography
;
Radiotherapy
;
Respiration
;
Ultrasonics*
7.Feasibility Study of the Radiophotoluminescent Glass Dosimeter for High-energy Electron Beams.
Kihong SON ; Haijo JUNG ; Sang Hun SHIN ; Hyun Ho LEE ; Sunghyun LEE ; Mi Sook KIM ; Young Hoon JI ; Kum Bae KIM
Korean Journal of Medical Physics 2011;22(1):52-58
Our goal is to assess the suitability of a glass dosimeter on detection of high-energy electron beams for clinical use, especially for radiation therapy. We examined the dosimetric characteristics of glass dosimeters including dose linearity, reproducibility, angular dependence, dose rate dependence, and energy dependence of 5 different electron energy qualities. The GD was irradiated with high-energy electron beams from the medical linear accelerator andgamma rays from a cobalt-60 teletherapy unit. All irradiations were performed in a water phantom. The result of the dose linearity for high-energy electron beams showed well fitted regression line with the coefficient of determination; R2 of 0.999 between 6 and 20 MeV. The reproducibility of GDs exposed to the nominal electron energies 6, 9, 12, 16, and 20 MeV was +/-1.2%. In terms of the angular dependence to electron beams,GD response differences to the electron beam were within 1.5% for angles ranging from 0degrees to 90degrees and GD's maximum response differencewas 14% lower at 180degrees. In the dose rate dependence, measured dose values were normalized to the value obtained from 500 MU/min. The uncertainties of dose rate were measured within +/-1.5% except for the value from 100 MU/min. In the evaluation of the energy dependence of the GD at nominal electron energies between 6 and 20 MeV, we obtained lower responses between 1.1% and 4.5% based on cobalt-60 beam. Our results show that GDs have a considerable potentiality for measuring doses delivered by high-energy electron beams.
Electrons
;
Feasibility Studies
;
Glass
;
Particle Accelerators
;
Water
8.Feasibility Study of Vertical Multileaf Collimator for Determination of Irradiation Size.
Chang Yeol LEE ; Kihong SON ; Sang Hun SHIN ; Seungwoo PARK ; Donghan LEE ; Haijo JUNG ; Munsik CHOI ; Won Young OH ; Kum Bae KIM ; Gwang Mo YANG ; Young Hoon JI
Korean Journal of Medical Physics 2011;22(1):3-11
The purpose of this study was to evaluate feasibility of Vertical Multileaf Collimator for determination of irradiation size using Vertical Multileaf Collimator and lead block to determine 4 different irradiation shape in case of Co-60 gamma-ray and 6 MV X-ray. We chose ion chamber, glass dosimeter and EBT chromic film to compare with Vertical Multileaf Collimator results and lead block results. In case of Co-60 gamma-ray and 6 MV X-ray, the central axis point dose normalized at reference field of lead block with ion chamber results for Vertical Multileaf Collimator were estimated higher than lead block about 5.1%, 4.2%. In case of Co-60 gamma-ray, the central axis point dose normalized at reference field of lead block with glass dosimeter results for Vertical Multileaf Collimator were estimated higher than lead block about 2.2%, 7.8%, 7.2%, 4.0% for reference, circle, triangle, cross field, respectively. In case of 6 MV X-ray, the central axis point dose normalized at reference field of lead block with glass dosimeter results for Vertical Multileaf Collimator were estimated higher than lead block about 6.7%, 6.2%, 3.8%, 6.2% for reference, circle, triangle, cross field, respectively. The results of EBT chromic film, Vertical Multileaf Collimator of penumbra size for all irradiation shape was smaller than lead block of those size that 2.0~3.5 mm for Co-60 gamma-ray, 0.5~1.0 mm for 6 MV X-ray. The results from this study, radiation treatment volume that results in shielding block can be minimized. In addition, during radiation treatment for 2, 3-dimensional radiation therapy using a Vertical Multileaf Collimator of this survey can be used to determine variety of irradiation fields.
Axis, Cervical Vertebra
;
Feasibility Studies
;
Glass
9.The Feasibility Study on the Application of Global Medical Device Nomenclature(GMDN).
Wanjuan YANG ; Jian ZHENG ; Jun LI ; Ying HUANG ; Chunqing ZHANG ; Jingli LI
Chinese Journal of Medical Instrumentation 2015;39(5):349-352
The article has analyzed the policy co-ordination, Industry coverage and technical experience of the global medical device nomenclature (GMDN) to our country, argued the feasibility on the application of GMDN in our medical device administration system, provided some reference on building the naming system of medical device in our country.
Equipment and Supplies
;
Feasibility Studies
;
Industry
;
Terminology as Topic
10.Feasibility of Preheating at 41 ℃ to Correct Red Blood Cell Parameters in the Presence of High-titer Cold Agglutinins.
Hong-Xiang XIE ; Yan SHEN ; Zhen-Zhen PANG ; Bin SUN ; Zhen-Ni WANG ; Shu-Hui XIE ; Yong-Lie ZHOU
Acta Academiae Medicinae Sinicae 2021;43(4):507-512
Objective To explore the feasibility of preheating in 41 ℃ water bath for 30 minutes to correct the red blood cell parameters in the specimens containing high-titer cold agglutinins(CAs). Methods Two specimens containing high-titer CAs were selected during work,and the parameters of complete blood count at room temperature or after preheating in 37 ℃ or 41 ℃ water bath were compared.The smears were stained,and the distribution of red blood cells was observed with a microscope.Further,74 specimens without CAs were collected for complete blood count,and then the test results at room temperature and after preheating at 41 ℃ were compared. Results At room temperature,the specimens containing high-titer CAs showed significantly reduced red blood cell count(RBC)and hematocrit(HCT),abnormally increased mean corpuscular hemoglobin(MCH)and mean cell hemoglobin concentration(MCHC),abnormal percents of hemoglobin(HGB)and RBC,and aggregation of a large number of red blood cells.After being preheated at 37 ℃ for a certain time,the specimens demonstrated obviously improved parameters while still aggregation of a small number of red blood cells.After being preheated at 41 ℃ for 30 minutes,the specimens showed significantly increased RBC,normal HCT,MCH,and MCHC,and evenly distributed red blood cells.The 74 specimens without CAs showed the comparability was ≥80% between room temperature and preheating at 41 ℃ for 30 minutes or 60 minutes. Conclusion We can preheat the specimens containing high-titer CAs in a water bath at 41 ℃ to obtain accurate red blood cell parameters.
Cryoglobulins
;
Erythrocyte Count
;
Erythrocytes
;
Feasibility Studies
;
Hematocrit