1.A study on the pathological type and surgical therapy of chronic pancreatitis
Fazhi ZHAO ; Siming XIE ; Yonghua CHEN ; Yunqiang CAI ; Xing WANG ; Nengwen KE ; Xubao LIU
Chinese Journal of General Surgery 2015;30(1):7-10
Objective To evaluate surgical therapies for chronic pancreatitis.Method The clinical data of 229 patients admitted for chronic pancreatitis during March 2009 to November 2013 in our hospital was retrospectively analyzed,different operation method and their clinical outcome were compared.Results Drainage operations or resection operations were made to all these 229 patients according to different types.57 patients underwent longitudinal pancreaticojejunostomy (LPJ procedure).118 patients received local resection of the head of pancreas combined with longitudinal pancreaticojejunostomy (Frey procedure in 105 cases,Berne procedure in 6 cases,Beger procedure in 7 cases).7 patients received pancreaticoduodenectomy,21 patients received distal pancreas resection,26 patients received other procedures.Post-operative pain relief rate was 89.3%,overall morbidity was 19.6%.Conclusions In cases of chronic pancreatitis,different surgical types are adopted according to their individual indications.Operation in accordance with pathological types guarantees clinical outcome.
2.Basic Magnesium Carbonate-Based Diffusive Gradients in Thin Films Technique for in situ Measurement of Dissolved Phosphorus in Eutrophic Waters
Fazhi XIE ; Tingting HU ; Haohan FU ; Xuan LUO ; Xianbiao WANG ; Dandan SHENG ; Haibin LI ; Xuechun WANG ; Zhiyong XIE
Chinese Journal of Analytical Chemistry 2016;44(6):965-969
A technique of diffusive gradients in thin films (DGT) was developed for the in situ measurement of reactive phosphorus species in natural waters, sediments and potentially soils. Polyacrylamide / basic magnesium carbonate was used as the novel binding phase of DGT. Various factors, such as initial concentration, deployment time, pH and ionic strength, which may affect the adsorption of phosphate to the DGT were investigated. H2 SO4(0. 25 mol/ L, 10 mL) was used for elution of phosphate from the binding gel, and an elution efficiency of 85±5% was obtained. The DGT measurement was independent of ionic strength (0. 001-0. 05 mol/ L) and pH (4. 10-9. 15). The results indicated that the maximum adsorption capacities of DGT were limited to 20. 4 μg per disc ( T = 25℃, pH = 7. 00, [ P] = 2 mg / L). Good agreement was obtained between the measurement results of DGT method and molybdenum blue method in the P concentration from 0. 001 to 20 mg / L. The method detection limit (MDL) was 102. 4 ng / L. Field performances of DGT in synthetic seawater, the coastal seawater of Xiamen, Lake Yihai, Lake Chaohu and Nanfei River indicated that the basic magnesium carbonate-DGT method was more reliable than the commonly used ferrihydrite-DGT method.