1.A primary study of endoscopic closure of acute gastric perforation using twin grasper combined with endoloops in a porcine survival model
Fangfen DONG ; Yingying HE ; Yuzhen CHEN ; Kai LIN ; Zeyu SONG ; Liangliang XU ; Zhaofei XIE ; Hong SHI
Chinese Journal of Digestive Endoscopy 2017;34(5):354-357
Objective To evaluate the feasibility and efficacy of twin grasper combined with endoloops on closing acute stomach perforation.Methods Two experimental porcines of stomach perforation underwent endoscopic closure by twin grasper combined with endoloops.Survival conditions and closure of perforating were observed.Results Mild infection and abdominal adhesions were observed in one week after operation.The nylon rope fell off and an ulcer-like lesion was presented in the closed position.The methylene blue leak test was negative.Histologic examination revealed chronic inflammatory cells infiltration,granulation,fibroplasias,and regenerative mucous membrane crawling toward the center of perforation.Conclusion The technique of twin grasper combined with nylon ropes in closing the acute stomach perforation is feasible and effective.
2.Application of virtual reality technology in teaching course of radiotherapy technology
Xiaobo LI ; Fangfen DONG ; Wenfang SONG ; Lifang CHEN ; Dongdong ZHANG ; Jianmin YAO ; Benhua XU
Chinese Journal of Radiation Oncology 2018;27(12):1093-1096
Objective To discuss the necessity and feasibility of application of virtual reality (VR) technology in the teaching course of radiotherapy technology based on the contradictions between the theory and practice of current teaching mode.Methods After in-depth analysis of the characteristics of the existing disciplinary teaching mode,VR technology was introduced to design software,glasses,operating handles and establish a special interactive platform. The teaching courses could be delivered via mobile phone side AR, helmet and AR, touch screen and PC virtual simulation with VR virtual simulation, etc. Six processes of radiotherapy were tested through online courses and offline groups to analyze the feasibility of this technology applied in the training of radiotherapy professionals. Results After the design of software and hardware and the analysis of test results,the online teaching could be utilized to write interactive programs,build virtual experience scenes, create course resource database and construct practical training courses and teaching system. The offline practice test could be applied to the simulation learning of feedback of the whole process, which possessed feasibility and development value. It could be applied to the theory and practice teaching of radiation therapy technology,making the teaching more convenient,vivid and intuitive. Conclusions VR technique combined with radiotherapy technology training can be delivered through online and offline teaching courses of theory and practice by using the plane and virtual simulation technology, which is convenient, quick and highly efficient and deserves widespread application.
3.Study of setup error and dosimetry of postoperative intensity-modulated radiotherapy for breast cancer using skin lead marker and iSCOUT image-guided positioning system
Fangfen DONG ; Liyan DAI ; Miaoyun HUANG ; Xing WENG ; Liuqing JIANG ; Benhua XU ; Xiaobo LI
Chinese Journal of Radiation Oncology 2021;30(10):1059-1064
Objective:To explore the application value of skin lead marker combined with iSCOUT image-guided positioning system in monitoring and correcting the setup error of intensity-modulated radiotherapy (IMRT) for breast cancer and calculate the PTV margin, aiming to provide reference for clinical practice.Methods:25 breast cancer patients treated with IMRT after modified radical mastectomy in Fujian Medical University Union Hospital from April to August 2019 were enrolled in this study. The skin lead marker combined with iSCOUT image-guided positioning system was employed for image-guided positioning based on the gold standard registration algorithm. Initial setup errors on the x (lateral), y (craniocaudal) and z (anteroposterior) axis and residual errors after the position correction were recorded and analyzed. The effect of the errors before and after image-guided correction upon the plan dose was compared and the reasonable PTV margin was calculated.Results:25 patients received 150 times of positioning verification using skin lead marker combined with iSCOUT image-guided positioning system. The absolute residual errors on the x-, y-and z-axis were (1.53±0.96), (1.30±0.99) and (1.34±0.92) mm, significantly smaller than the initial setup errors of (2.63±2.12), (2.41±2.45) and (3.07±2.77) mm (all P<0.001). The percentage of dose deviation due to residual errors was also smaller than that of the initial errors. Significant differences were observed in D 98%, D 2%, D max of PTV, D max of the heart, D max of the healthy breast, and D mean of the affected lung and both lungs. The percentage deviation from the original plan was decreased from 2.18%, 3.19%, 10.66%, 8.75%, 48.21%, 10.50%, and 3.66% to 0.38%, 0.23%, 2.31%, 0.04%, 13.78%, 6.35% and 0.41%, respectively (all P<0.05). PTV margins on the x-, y-and z-axis after correction were calculated as 1.87, 1.75 and 1.69 mm, respectively. Conclusion:It is feasible and valuable to apply the skin lead marker combined with iSCOUT image-guided positioning system in the positioning verification and correction of breast cancer radiotherapy position, providing novel reference for clinical PTV margin.
4.Research and development of remote training system for radiotherapy CT simulation based on virtual reality technology
Fen ZHENG ; Benhua XU ; Miaoyun HUANG ; Liuqing JIANG ; Fangfen DONG ; Lanyan GUO ; Jianmin YAO ; Yuangui CHEN ; Xiaobo LI
Chinese Journal of Radiation Oncology 2020;29(12):1070-1074
Objective:To develop a remote training system for CT simulation positioning of radiotherapy using virtual reality technology, and to explore a new method of medical training.Methods:The 3DMax and Maya were employed to establish the 3D model. The unity3D engine was adopted to develop 3D virtual operation and interaction system. Java spring MVC architecture was utilized as the system background service. MySQL was used as the background database system. The users were assigned into two roles: teacher and student, and the modes were divided into teaching and assessment modes.Results:The function of the system covered the whole process of CT simulation positioning, mainly including modules of patient information management, CT simulation positioning machine cognition, body position fixation technology, CT positioning scanning, and emergency handling, etc. Since it was put into use in 2018, the system has been running stably, with 14 920 pages views and an 86.66% pass rate. Compared with the traditional training, the training efficiency has been significantly improved and has received unanimous recognition.Conclusions:The remote training system can effectively improve the clinical practice ability and humanistic care ability of the trainees, which has good autonomy, sharing, and innovation. At present, the system has been put online and has strong popularization with prospects for broad application.
5.Experimental study of percutaneous transhepatic implantation of recoverable fiducial marker in Cyberknife tracking therapy
Xianzhi DENG ; Jing CHEN ; Zhanghua LIN ; Nuoxi LI ; Fangfen DONG ; Shanting HE ; Jianping ZHANG ; Benhua XU ; Jiajun MA ; Xiaobo LI
Chinese Journal of Radiological Medicine and Protection 2023;43(2):81-86
Objective:To evaluate the feasibility of a novel liver fiducial marker implantation method for internal fixation and removal of rabbit livers, in order to use in Cyberknife tracking therapy.Methods:Experiments were conducted in vivo and in vitro. In the in vivo experiment, three fiducial markers were implanted percutaneously in each liver of ten rabbits under anesthesia, and the fourth fiducial marker with an external catheter and fixed thin wire was implanted ten days later. After the reference group (the first and the second maker), and the casing group (the first and the fourth marker) were respectively registered and tracked with the Cyberknife, the implantation success rate, registration accuracy, and removal safety of fiducial markers were assessed. The tensile test was performed using liver in vitro by measuring the resistance required to dislodge the spring coil fiducial markers and the fiducial markers without spring coil from liver. Results:The intrahepatic catheter implantation and removal of fiducial marker in rabbit liver had a success rate of 100% and no distant migration. The operation-related and postoperative complications were not occurred. All fiducial markers were successfully traced. Compared to the reference group, the casing group had slightly higher translational errors in supero-inferior and antero-posterior directions ( Z=-11.77, -4.57, P<0.05), and lower translational errors in left-right direction ( Z=-2.52, P<0.05). The dislodgement forces for spring coil fiducial markers was (2.23±0.85) N, significantly different with (0.81±0.13) N for fiducial markers without spring coil ( Z=- 2.31, P < 0.05). Conclusions:The spiral coil structure provides superior fixation in the punctured needle channel, the thin line limits the distant displacement of the fiducial marker outside the liver, and the catheter establishes a channel for the removal. The general operation is simple and easy.
6.Development and application of the virtual simulation teaching experiment software of the bronchoscopy intelligent navigation-based fiducial marker implantation technology
Fenfang FU ; Jing CHEN ; Xianzhi DENG ; Minghui CHEN ; Nuoxi LI ; Fangfen DONG ; Fen ZHENG ; Jianmin YAO ; Benhua XU ; Xiaobo LI
Chinese Journal of Radiological Medicine and Protection 2023;43(5):343-350
Objective:To investigate the necessity and feasibility of the virtual simulation teaching experiment software of the bronchoscopy intelligent navigation-based fiducial marker implantation technology in the clinical application of radiotherapy.Methods:This study developed a 3D virtual operation and interactive system using the Unity3D engine, tools including 3Dmax and Maya, and the SQL database. The scenes in the system were produced using the currently popular next-generation production process. Targeting the priorities and difficulties in the implantation of fiducial markers, the system developed in this study allowed for simulated demonstration and training based on 12 steps and 10 knowledge points. Internal tests and remote evaluation tests were adopted in this system to obtain the test result of each subject. Then, the application value of the system was analyzed based on the test result.Results:As of May 1, 2022, the system had received 2 409 views and 425 test participants, with an test completion rate of 100% and an experiment pass rate of 96.5%. Moreover, this system won unanimous praise from 167 users, primarily including the students majoring in multilevel medical imaging technology and medical imaging science from the Fujian Medical University, as well as the radiotherapy-related staff of this university.Conclusions:The virtual simulation teaching experiment software of the bronchoscopy intelligent navigation-based fiducial marker implantation technology can be applied to the teaching of students and the training of related professionals.
7.The remote training system for quality assurance of medical electronic linear accelerators based on extended reality technology
Jing CHEN ; Xing WENG ; Liuqing JIANG ; Fangfen DONG ; Fen ZHENG ; Lanyan GUO ; Jianmin YAO ; Xiaobo LI
Chinese Journal of Radiation Oncology 2023;32(3):248-253
Objective:To improve the quality assurance (QA) skills of radiotherapy personnel and medical students and reduce the radiation risk of training by developing a remote training system for QA of medical electronic linear accelerators.Methods:This training system was built based on radiotherapy technology and quality control contents of medical electronic linear accelerators, and a virtual reality interactive software was developed using extended reality (XR) technology Unity 3D. A remote control module of multi-terminal platform was also developed. A multi-perspective evaluation system was adopted and a questionnaire was designed to analyze the application value of this system.Results:The training system reproduced the live environment and physical objects of medical electronic linear accelerator treatment room. It built a multi-terminal virtual simulation training system with radiotherapy technology as well as QA knowledge system. This system could provide 5G remote control of medical electronic linear accelerator for off-site quality control demonstration and guidance. By March 1, 2022, a total number of 133 people had been trained using this system, 76 valid questionnaires had been taken, of which 90.79% (69/76) of the respondents trusted the experimental results shown by the system and 88.16% (67/76) of the respondents considered the training system necessary.Conclusions:The training effect of this system is widely recognized. It fundamentally reduces the training radiation hazard and provides reference for the reform and progress of QA training mode of medical electronic linear accelerators.
8.Accuracy of the optically guided tracking system in radiotherapy
Zhanghua LIN ; Xianzhi DENG ; Fangfen DONG ; Jing CHEN ; Fen ZHENG ; Xing WENG ; Benhua XU ; Xiaobo LI
Chinese Journal of Radiological Medicine and Protection 2023;43(9):698-704
Objective:To explore the tracking accuracy of the surface optically guided tracking system (OGTS) in radiotherapy.Methods:Phantom verification and clinical trial verification were adopted. Specialized equipment was employed for the phantom verification. Specifically, the displacement of the optical markers as they moved from a predetermined position to the target position on the reflector ball platform was captured using the OGTS, and then the obtained displacement was compared with the fixed distance within the phantom to calculate the accuracy and repeatability of the OGTS. For the clinical trial verification, 45 patients treated with radiotherapy, which consisted of 15 cases with head, breast, and rectal tumors each, were selected to investigate the tracking accuracy and repeatability of the OGTS. For each patient, the values derived from the image-guided positioning system (IGPS) and the OGTS before and after image-guided setup error correction during three times of fractionated radiotherapy were randomly obtained. The translational errors of each error correction were also recorded. Before radiotherapy, patients′ setup errors were corrected and relevant data were obtained using the IGPS. The correction result of translation errors obtained using the IGPS served as a gold standard to verify the accuracy of the OGTS in monitoring the translational motion of patients. Finally, the comprehensive translational deviation of both method was calculated.Results:The phantom measurements showed that the comprehensive translational deviation for tracking accuracy and tracking repeatability of the OGTS had a maximum deviation and a standard deviation of 0.18 mm and 0.03 mm, respectively. The clinical trial result indicated that the tracking accuracy of IGPS and OGTS exhibited statistically significant differences only for the head in the z direction ( t = 2.21, P < 0.05). Conversely, no statistically significant differences were observed for the head in the remaining directions or for the breast and rectum in the three translational directions ( P > 0.05). The analysis showed that comprehensive translational deviations for the head, breast, and rectum derived from OGTS and IGPS were (0.91±0.62), (1.64±1.30), and (1.52±1.29) mm, respectively, satisfying the requirement that the deviations should be below 2 mm. Conclusions:The OGTS, featuring easy operation and high tracking accuracy, can assist the IGPS in real-time respiratory monitoring during radiotherapy.