1.Optimization of Image Tracking Algorithm Used in 4D Radiation Therapy.
Jongin PARK ; Eunhyuk SHIN ; Youngyih HAN ; Heechul PARK ; Jaiki LEE ; Doo Ho CHOI
Korean Journal of Medical Physics 2012;23(1):8-14
In order to develop a Patient respiratory management system includinga biofeedback function for4-dimentional radiation therapy, this study investigated anoptimal tracking algorithmfor moving target using IR (Infra-red) camera as well as commercial camera. A tracking system was developed by LabVIEW 2010. Motion phantom images were acquired using a camera (IR or commercial). After image process were conducted to convert acquired image to binary image by applying a threshold values, several edge enhance methods such as Sobel, Prewitt, Differentiation, Sigma, Gradient, Roberts, were applied. The targetpattern was defined in the images, and acquired image from a moving targetwas tracked by matching pre-defined tracking pattern. During the matching of imagee, thecoordinateof tracking point was recorded. In order to assess the performance of tracking algorithm, the value of score which represents theaccuracy of pattern matching was defined. To compare the algorithm objectively, we repeat experiments 3 times for 5 minuts for each algorithm. Average valueand standard deviations (SD) of score were automatically calculatedsaved as ASCII format. Score of threshold only was 706, and standard deviation was 84. The value of average and SD for other algorithms which combined edge detection method and thresholdwere 794, 64 in Sobel, 770, 101 in Differentiation, 754, 85 in Gradient, 763, 75 in Prewitt, 777, 93 in Roberts, and 822, 62 in Sigma, respectively. According to score analysis, the most efficient tracking algorithm is the Sigma method. Therefore, 4-dimentional radiation threapy is expected tobemore efficient if threshold and Sigma edge detection method are used together in target tracking.
Biofeedback, Psychology
;
Humans
;
Track and Field
2.Analysis of the Imaging Dose for IGRT/Gated Treatments.
Jung Suk SHIN ; Youngyih HAN ; Sang Gyu JU ; Eunhyuk SHIN ; Chae Seon HONG ; Yong Chan AHN
The Journal of the Korean Society for Therapeutic Radiology and Oncology 2009;27(1):42-48
PURPOSE: The introduction of image guided radiation therapy/four-dimensional radiation therapy (IGRT/4DRT) potentially increases the accumulated dose to patients from imaging and verification processes as compared to conventional practice. It is therefore essential to investigate the level of the imaging dose to patients when IGRT/4DRT devices are installed. The imaging dose level was monitored and was compared with the use of pre-IGRT practice. MATERIALS AND METHODS: A four-dimensional CT (4DCT) unit (GE, Ultra Light Speed 16), a simulator (Varian Acuity) and Varian IX unit with an on-board imager (OBI) and cone beam CT (CBCT) were installed. The surface doses to a RANDO phantom (The Phantom Laboratory, Salem, NY USA) were measured with the newly installed devices and with pre-existing devices including a single slice CT scanner (GE, Light Speed), a simulator (Varian Ximatron) and L-gram linear accelerator (Varian, 2100C Linac). The surface doses were measured using thermo luminescent dosimeters (TLDs) at eight sites-the brain, eye, thyroid, chest, abdomen, ovary, prostate and pelvis. RESULTS: Compared to imaging with the use of single slice non-gated CT, the use of 4DCT imaging increased the dose to the chest and abdomen approximately ten-fold (1.74+/-0.34 cGy versus 23.23+/-3.67 cGy ). Imaging doses with the use of the Acuity simulator were smaller than doses with the use of the Ximatron simulator, which were 0.91+/-0.89 cGy versus 6.77+/-3.56 cGy, respectively. The dose with the use of the electronic portal imaging device (EPID; Varian IX unit) was approximately 50% of the dose with the use of the L-gram linear accelerator (1.83+/-0.36 cGy versus 3.80+/-1.67 cGy). The dose from the OBI for fluoroscopy and low-dose mode CBCT were 0.97+/-0.34 cGy and 2.3+/-0.67 cGy, respectively. CONCLUSION: The use of 4DCT is the major source of an increase of the radiation (imaging) dose to patients. OBI and CBCT doses were small, but the accumulated dose associated with everyday verification need to be considered
Abdomen
;
Brain
;
Cone-Beam Computed Tomography
;
Electronics
;
Electrons
;
Eye
;
Female
;
Fluoroscopy
;
Four-Dimensional Computed Tomography
;
Humans
;
Light
;
Ovary
;
Particle Accelerators
;
Pelvis
;
Prostate
;
Thorax
;
Thyroid Gland
3.The Clinical Implementation of 2D Dose Distribution QA System for the Patient Specific Respiratory-gated Radiotherapy.
Jin Sung KIM ; Eunhyuk SHIN ; Jung Suk SHIN ; Sang Gyu JU ; Youngyih HAN ; Hee Chul PARK ; Doo Ho CHOI
Korean Journal of Medical Physics 2010;21(2):127-136
Emerging technologies such as four-dimensional computed tomography (4D CT) is expected to allow clinicians to accurately model interfractional motion and to quantitatively estimate internal target volumes (ITVs) for radiation therapy involving moving targets. A need exists for a 4D radiation therapy quality assurance (QA) device that can incorporate and analyze the patient specific intrafractional motion as it relate to dose delivery and respiratory gating. We built a 4D RT prototype device and analyzed the patient-specific 4D radiation therapy QA for 2D dose distributions successfully. With more improvements, the 4D RT QA prototype device could be an integral part of a 4D RT decision process to confirm the dose delivery.
Four-Dimensional Computed Tomography
;
Humans
;
Polymethacrylic Acids
4.A Dose Volume Histogram Analyzer Program for External Beam Radiotherapy.
Jin Sung KIM ; Myonggeun YOON ; Sung Yong PARK ; Jung Suk SHIN ; Eunhyuk SHIN ; Sang Gyu JU ; Youngyih HAN ; Yong Chan AHN
The Journal of the Korean Society for Therapeutic Radiology and Oncology 2009;27(4):240-248
PURPOSE: To provide a simple research tool that may be used to analyze a dose volume histogram from different radiation therapy planning systems for NTCP (Normal Tissue Complication Probability), OED (Organ Equivalent Dose) and so on. MATERIALS AND METHODS: A high-level computing language was chosen to implement Niemierko's EUD, Lyman-Kutcher-Burman model's NTCP, and OED. The requirements for treatment planning analysis were defined and the procedure, using a developed GUI based program, was described with figures. The calculated data, including volume at a dose, dose at a volume, EUD, and NTCP were evaluated by a commercial radiation therapy planning system, Pinnacle (Philips, Madison, WI, USA) for comparison. RESULTS: The volume at a special dose and a dose absorbed in a volume on a dose volume histogram were successfully extracted using DVH data of several radiation planning systems. EUD, NTCP and OED were successfully calculated using DVH data and some required parameters in the literature. CONCLUSION: A simple DVH analyzer program was developed and has proven to be a useful research tool for radiation therapy.
5.Digital Tomosynthesis for Patient Alignment System Using Half-fan Mode CBCT Projection Images.
Justin C PARK ; Sung Ho PARK ; Jin Sung KIM ; Yongyih HAN ; Sang Gyu JU ; Eunhyuk SHIN ; Jung Suk SHIN ; Hee Chul PARK ; Yong Chan AHN ; Willian Y SONG
Korean Journal of Medical Physics 2010;21(4):360-366
To generate on-board digital tomosynthesis (DTS) for three-dimensionalimage-guided radiation therapy (IGRT) as an alternative to conventional portal imaging or on-board cone-beam computed tomography (CBCT), two clinical cases (liver and bladder) were selected to illustrate the capabilities of on-board DTS for IGRT. DTS images were generated from subsets of CBCT projection data (45, 162 projections) using half-fan mode scanning with a Feldkamp-type reconstruction algorithm. Digital tomosynthesis slices appeared similar to coincident CBCT planes and yielded substantially more anatomic information. Improved bony and soft-tissue visibility in DTS images is likely to improve target localization compared with radiographic verification techniques and might allow for daily localization of a soft-tissue target. Digital tomosynthesis might allow targeting of the treatment volume on the basis of daily localization.
Cone-Beam Computed Tomography
;
Humans
;
Patient Positioning
6.Efficacy of a Respiratory Training System on the Regularity of Breathing.
Eunhyuk SHIN ; Hee Chul PARK ; Youngyih HAN ; Sang Gyu JU ; Jung Suk SHIN ; Yong Chan AHN
The Journal of the Korean Society for Therapeutic Radiology and Oncology 2008;26(3):181-188
PURPOSE: In order to enhance the efficiency of respiratory gated 4-dimensional radiation therapy for more regular and stable respiratory period and amplitude, a respiration training system was designed, and its efficacy was evaluated. MATERIALS AND METHODS: The experiment was designed to measure the difference in respiration regularity following the use of a training system. A total of 11 subjects (9 volunteers and 2 patients) were included in the experiments. Three different breathing signals, including free breathing (free-breathing), guided breathing that followed training software (guided-breathing), and free breathing after the guided-breathing (post guided-breathing), were consecutively recorded in each subject. The peak-to-peak (PTP) period of the breathing signal, standard deviation (SD), peak-amplitude and its SD, area of the one cycle of the breathing wave form, and its root mean square (RMS) were measured and computed. RESULTS: The temporal regularity was significantly improved in guided-breathing since the SD of breathing period reduced (free-breathing 0.568 vs guided-breathing 0.344, p=0.0013). The SD of the breathing period representing the post guided-breathing was also reduced, but the difference was not statistically significant (free-breathing 0.568 vs. guided-breathing 0.512, p=ns). Also the SD of measured amplitude was reduced in guided-breathing (free-breathing 1.317 vs. guided-breathing 1.068, p=0.187), although not significant. This indicated that the tidal volume for each breath was kept more even in guided-breathing compared to free-breathing. There was no change in breathing pattern between free-breathing and guided-breathing. The average area of breathing wave form and its RMS in postguided-breathing, however, was reduced by 7% and 5.9%, respectively. CONCLUSION: The guided-breathing was more stable and regular than the other forms of breathing data. Therefore, the developed respiratory training system was effective in improving the temporal regularity and maintaining a more even tidal volume.
7.Development of Movement Analysis Program and Its Feasibility Test in Streotactic Body Radiation Threrapy.
Eunhyuk SHIN ; Youngyih HAN ; Hee Chul PARK ; Jin Sung KIM ; Jung Suk SHIN ; Sang Gyu JU ; Jihea LEE ; Jong Ho AHN ; Jaiki LEE ; Doo Ho CHOI
Korean Journal of Medical Physics 2011;22(3):107-116
Respiratory gated radiation therapy and stereotactic body radiation therapy require identical tumor motions during each treatment with the motion detected in treatment planning CT. Therefore, this study developed a tumor motion monitoring and analysis system during the treatments employing RPM data, gated setup OBI images and a data analysis software. A respiratory training and guiding program which improves the regularity of breathing was used to patients. The breathing signal was obtained by RPM and the recorded data in the 4D console was read after treatment. The setup OBI images obtained gated at 0% and 50% of breathing phases were used to detect the tumor motion range in crenio-caudal direction. By matching the RPM data recorded at the OBI imaging time, a factor which converts the RPM motion to the tumor motion was computed. RPM data was entered to the institute developed data analysis software and the maximum, minimum, average of the breathing motion as well as the standard deviation of motion amplitude and period was computed. The computed result is exported in an excel file. The conversion factor was applied to the analyzed data to estimate the tumor motion. The accuracy of the developed method was tested by using a moving phantom, and the efficacy was evaluated for 10 stereotactic body radiation therapy patients. For the sine wave motion of the phantom with 4 sec of period and 2 cm of peak-to-peak amplitude, the measurement was slightly larger (4.052 sec) and the amplitude was smaller (1.952 cm). For patient treatment, one patient was evaluated not to qualified to SBRT due to the usability of the breathing, and in one patient case, the treatment was changed to respiratory gated treatment due the larger motion range of the tumor than treatment planed motion. The developed method and data analysis program was useful to estimate the tumor motion during treatment.
Humans
;
Respiration
;
Statistics as Topic
8.Comparison of the Efficacy of 2D Dosimetry Systems in the Pre-treatment Verification of IMRT.
Chae Seon HONG ; Jongsoo LIM ; Sang Gyu JU ; Eunhyuk SHIN ; Youngyih HAN ; Yong Chan AHN
The Journal of the Korean Society for Therapeutic Radiology and Oncology 2009;27(2):91-102
PURPOSE: To compare the accuracy and efficacy of EDR2 film, a 2D ionization chamber array (MatriXX) and an amorphous silicon electronic portal imaging device (EPID) in the pre-treatment QA of IMRT. MATERIALS AND METHODS: Fluence patterns, shaped as a wedge with 10 steps (segments) by a multi-leaf collimator (MLC), of reference and test IMRT fields were measured using EDR2 film, the MatriXX, and EPID. Test fields were designed to simulate leaf positioning errors. The absolute dose at a point in each step of the reference fields was measured in a water phantom with an ionization chamber and was compared to the dose obtained with the use of EDR2 film, the MatriXX and EPID. For qualitative analysis, all measured fluence patterns of both reference and test fields were compared with calculated dose maps from a radiation treatment planning system (Pinnacle, Philips, USA) using profiles and gamma evaluation with 3%/3 mm and 2%/2 mm criteria. By measurement of the time to perform QA, we compared the workload of EDR2 film, the MatriXX and EPID. RESULTS: The percent absolute dose difference between the measured and ionization chamber dose was within 1% for the EPID, 2% for the MatriXX and 3% for EDR2 film. The percentage of pixels with gamma%>1 for the 3%/3 mm and 2%/2 mm criteria was within 2% for use of both EDR2 film and the EPID. However, differences for the use of the MatriXX were seen with a maximum difference as great as 5.94% with the 2%/2 mm criteria. For the test fields, EDR2 film and EPID could detect leaf-positioning errors on the order of -3 mm and -2 mm, respectively. However it was difficult to differentiate leaf-positioning errors with the MatriXX due to its poor resolution. The approximate time to perform QA was 110 minutes for the use of EDR2 film, 80 minutes for the use of the MatriXX and approximately 55 minutes for the use of the EPID. CONCLUSION: This study has evaluated the accuracy and efficacy of EDR2 film, the MatriXX and EPID in the pre-treatment verification of IMRT. EDR2 film and the EPID showed better performance for accuracy, while the use of the MatriXX significantly reduced measurement and analysis times. We propose practical and useful methods to establish an effective QA system in a clinical environment.
Electronics
;
Electrons
;
Silicon
;
Water
9.Analysis of changes in dose distribution due to respiration during IMRT.
Jung Suk SHIN ; Eunhyuk SHIN ; Youngyih HAN ; Sang Gyu JU ; Jin Sung KIM ; Sung Hwan AHN ; Tae Gyu KIM ; Bae Kwon JEONG ; Hee Chul PARK ; Young Chan AHN ; Doo Ho CHOI
Radiation Oncology Journal 2011;29(3):206-213
PURPOSE: Intensity modulated radiation therapy (IMRT) is a high precision therapy technique that can achieve a conformal dose distribution on a given target. However, organ motion induced by respiration can result in significant dosimetric error. Therefore, this study explores the dosimetric error that result from various patterns of respiration. MATERIALS AND METHODS: Experiments were designed to deliver a treatment plan made for a real patient to an in-house developed motion phantom. The motion pattern; the amplitude and period as well as inhale-exhale period, could be controlled by in-house developed software. Dose distribution was measured using EDR2 film and analysis was performed by RIT113 software. Three respiratory patterns were generated for the purpose of this study; first the 'even inhale-exhale pattern', second the slightly long exhale pattern (0.35 seconds longer than inhale period) named 'general signal pattern', and third a 'long exhale pattern' (0.7 seconds longer than inhale period). One dimensional dose profile comparisons and gamma index analysis on 2 dimensions were performed RESULTS: In one-dimensional dose profile comparisons, 5% in the target and 30% dose difference at the boundary were observed in the long exhale pattern. The center of high dose region in the profile was shifted 1 mm to inhale (caudal) direction for the 'even inhale-exhale pattern', 2 mm and 5 mm shifts to exhale (cranial) direction were observed for 'slightly long exhale pattern' and 'long exhale pattern', respectively. The areas of gamma index >1 were 11.88%, 15.11%, and 24.33% for 'even inhale-exhale pattern', 'general pattern', and 'long exhale pattern', respectively. The long exhale pattern showed largest errors. CONCLUSION: To reduce the dosimetric error due to respiratory motions, controlling patient's breathing to be closer to even inhaleexhale period is helpful with minimizing the motion amplitude.
Humans
;
Respiration
10.Development of an Offline Based Internal Organ Motion Verification System during Treatment Using Sequential Cine EPID Images.
Sang Gyu JU ; Chae Seon HONG ; Woong HUH ; Min Kyu KIM ; Youngyih HAN ; Eunhyuk SHIN ; Jung Suk SHIN ; Jing Sung KIM ; Hee Chul PARK ; Sung Hwan AHN ; Do Hoon LIM ; Doo Ho CHOI
Korean Journal of Medical Physics 2012;23(2):91-98
Verification of internal organ motion during treatment and its feedback is essential to accurate dose delivery to the moving target. We developed an offline based internal organ motion verification system (IMVS) using cine EPID images and evaluated its accuracy and availability through phantom study. For verification of organ motion using live cine EPID images, a pattern matching algorithm using an internal surrogate, which is very distinguishable and represents organ motion in the treatment field, like diaphragm, was employed in the self-developed analysis software. For the system performance test, we developed a linear motion phantom, which consists of a human body shaped phantom with a fake tumor in the lung, linear motion cart, and control software. The phantom was operated with a motion of 2 cm at 4 sec per cycle and cine EPID images were obtained at a rate of 3.3 and 6.6 frames per sec (2 MU/frame) with 1,024x768 pixel counts in a linear accelerator (10 MVX). Organ motion of the target was tracked using self-developed analysis software. Results were compared with planned data of the motion phantom and data from the video image based tracking system (RPM, Varian, USA) using an external surrogate in order to evaluate its accuracy. For quantitative analysis, we analyzed correlation between two data sets in terms of average cycle (peak to peak), amplitude, and pattern (RMS, root mean square) of motion. Averages for the cycle of motion from IMVS and RPM system were 3.98+/-0.11 (IMVS 3.3 fps), 4.005+/-0.001 (IMVS 6.6 fps), and 3.95+/-0.02 (RPM), respectively, and showed good agreement on real value (4 sec/cycle). Average of the amplitude of motion tracked by our system showed 1.85+/-0.02 cm (3.3 fps) and 1.94+/-0.02 cm (6.6 fps) as showed a slightly different value, 0.15 (7.5% error) and 0.06 (3% error) cm, respectively, compared with the actual value (2 cm), due to time resolution for image acquisition. In analysis of pattern of motion, the value of the RMS from the cine EPID image in 3.3 fps (0.1044) grew slightly compared with data from 6.6 fps (0.0480). The organ motion verification system using sequential cine EPID images with an internal surrogate showed good representation of its motion within 3% error in a preliminary phantom study. The system can be implemented for clinical purposes, which include organ motion verification during treatment, compared with 4D treatment planning data, and its feedback for accurate dose delivery to the moving target.
Diaphragm
;
Human Body
;
Lung
;
Particle Accelerators
;
Track and Field