1.Intravascular Ultrasound Assessment of the Coronary Intervention.
Moo Hyun KIM ; Won Suk ANN ; Sung Jin BAE ; Byung Cheol KIM ; Ji Won SON ; Hyun Kuk DHO ; Seong Eun KIM ; Jong Seong KIM
Korean Circulation Journal 1995;25(5):930-941
BACKGROUND: Coronary arterigraphy has been used as a tool to assess the degree of coronary artery narrowing and the result of balloon angioplasty, which frequently underestimates the degree of atherosclerosis. Intravascular ultrasound(IVUS) can give more delicate information about plaque morphology and the result of coronary intervention. We compared qualitaive and quantitative measurement between IVUS and coronary angiography after coronary intervention. METHODS: We used 30 or 20 MHz intravascular ultrasound catheter which was connected to Hewlett Packard Sonos 1500 Intravasscular equiment in 5 coronary balloon angiopasty and 3 Palmaz-Schatz stent implantation cases. Sites of intervention were at the left anterior descending coronary artery in 7 patients and at the left circumflex artery in one patient. Quantitative coronary angiography(QCA) was done by CAAS II system. We measured referenc diameter(RD), minimal lumen diamter(MLD), Lumen and vessel cross sectional areas(LCSA,VCSA) obstraction area(OA) and plaque area(PA) and also analysed plaque morphology. RESULTS: 1) IVUS is more sensitive in the detection of eccentricity, Calcification and dissection. 2) Before intervention, the mean reference diameter was 2.87+/-0.42mm,3.07+/-0.39mm,% diameter stenosis was 52.4+/-11.6%,65.3+/-9.22% and MLD was 1.32+/-0.24mm, 1.07+/-0.23mm in IVUS and QCA, respectively, which were no statistical significance between these parameters(p>0.05). After intervention, MLD and OA increased significantly(p<0.01) com pared with basal values but there were no significant difference between MLD and OA between 2 measurements(p>0.05). Plaque area measured by IVUS decreased from 9.84 to 7.26mm2 without statistical significance(p>0.05). 3) There was a good correlation in the measurement of the reference segments before intervention but this correlation was much lower after intervention in the reference and stenosis segments between 2 methods(r=0.8723 vs 0.6538, p<0.01). CONCLUSION: IVUS is considered as a sensitive tool in the detection of calcification, eccentricity and dissection and in evaluationg the results of the coronary intervention.
Angioplasty, Balloon
;
Arteries
;
Atherosclerosis
;
Catheters
;
Constriction, Pathologic
;
Coronary Angiography
;
Coronary Vessels
;
Humans
;
Stents
;
Ultrasonography*
2.Blood Pressure Difference between Right and Left Arms of Some College Freshmen.
Ha Jin KIM ; Chang Won WON ; Eun Suk ANN ; Jung Ju JUNG ; Byung Sung KIM ; Hyun Rim CHOI
Journal of the Korean Academy of Family Medicine 2003;24(2):166-171
BACKGROUND: Hypertension is a main cause of heart blood vessel disease. To diagnose and treat hypertension, it is necessary to measure blood pressure accurately. There are various factors that influence blood pressure. According to real clinical demonstrators and some recent studies, blood pressure differences between right and left arms are often observed. This study was intended to know whether the differences are really found and wheather the correlation exists between mid-arm circumferences and the blood pressure differences according to right-handed or left-handed which were considered as an important factor in affecting blood pressures. METHODS: One hundred sixty nine college freshmen of year 2001 were chosen. Among them, 103 were right- handed and 66 left-handed. Which arms to be checked first were determined randomly. This sequence was repeated two times on each person. Their mid-arm circumferences were measured, also. RESULTS: For right-handed persons, systolic blood pressure in right arm (119.2+/-12.3 mmHg) was significantly higher than in left arm (118.0+/-12.0 mmHg) (P<0.005). But diastolic blood pressure differences between right arm (75.3+/-10.0 mmHg) and left arm (75.0+/-9.5 mmHg) was not significant statistically. For left-handed persons, systolic blood pressure was 120.3+/-9.9 mmHg in right arm and 120.0+/-10.3 mmHg in left arm. However, diastolic blood pressure in right arm (76.7 9.4 mmHg) was significantly higher than in left arm (75.0+/-8.6 mmHg) (P<0.005). For right handed persons, their arm circumferences (26.2+/-2.8 cm) were significantly thicker than left ones (25.9+/-2.9 cm). For left-handed, left arm circumference (25.9+/-2.7 cm) was significantly thicker than right one (25.5+/-2.6 cm). As for the blood pressure difference in arm tested order, the first measured systolic blood pressure (right arm; 120.9+/-11.7 mmHg, left arm; 120.0+/-11.9 mmHg) was significantly higher than the second measured one (right arm; 118.3+/-11.8 mmHg, left arm; 117.8+/-11.6 mmHg) (P<0.005). However, the first measured diastolic blood pressure (right arm; 76.3+/-10.5 mmHg, left arm; 75.5+/-9.4 mmHg) did not have more significance than the second measured one (right arm; 75.4+/-9.9 mmHg, left arm; 74.6+/-10.8 mmHg). CONCLUSION: The right-handed person's blood pressure was higher in the right arm, but for the left-handed persons it was not significantly different in both arms. The second measurement of blood pressure was lower than the first measurement in both arms. The arm circumference depending on the right/left-handedness influenced the blood pressure, but clear correlation between them was not observed. Therefore, if possible, when the blood pressure is measured, it is advised to check blood pressure in both arms before diagnosing hypertension.
Arm*
;
Blood Pressure*
;
Blood Vessels
;
Hand
;
Heart
;
Humans
;
Hypertension
3.Comparison of exit site infection and peritonitis incidences between povidone-iodine and normal saline use for chronic exit site care in peritoneal dialysis patients.
Su Mi LEE ; Hwa Seong NAM ; Eu Gene JEONG ; Young Ki SON ; Seong Eun KIM ; Won Suk ANN
Kidney Research and Clinical Practice 2014;33(3):144-149
BACKGROUND: Catheter-related exit site infection is a major risk factor for the development of peritonitis and can contribute to failure of treatment maintenance in peritoneal dialysis (PD) patients. Although povidone-iodine can be used for exit site care, the irritation induced by the local application of povidone-iodine could lead to secondary infection. Therefore, we evaluated the clinical effectiveness of normal saline compared with povidone-iodine as a method of exit site care in chronic PD patients. METHODS: In all, 126 patients undergoing PD treatment for>46 months between January 2006 and December 2009 were enrolled. Data were retrospectively analyzed for the incidence of exit site infection and peritonitis for 2 years prior to and after December 2007. In addition, we identified the incidences of catheter- related infections during follow-ups from January 2010 to December 2013. RESULTS: The participants' mean age was 58.87+/-12.9 years. The incidences of exit site infection and peritonitis were one episode per 64.6 patients-months and one episode per 40.4 patients-months in the povidone-iodine group, respectively, whereas these were one episode per 57.5 patients-months and one episode per 45.6 patients-months in the normal saline group, respectively. Whereas Gram-positive bacteria most frequently caused catheter-related infections in both groups, culture-negative infections were dominant in the normal saline group. CONCLUSION: Exit site care using normal saline did not increase the incidence of exit site infection and peritonitis. Therefore, normal saline may be an alternative treatment for exit site care in patients receiving PD.
Catheter-Related Infections
;
Coinfection
;
Follow-Up Studies
;
Gram-Positive Bacteria
;
Humans
;
Incidence*
;
Peritoneal Dialysis*
;
Peritonitis*
;
Povidone-Iodine*
;
Retrospective Studies
;
Risk Factors
4.Effects of low-dose niacin on dyslipidemia and serum phosphorus in patients with chronic kidney disease.
Hyo Jin KANG ; Do Kyong KIM ; Su Mi LEE ; Kyung Han KIM ; Seung Hee HAN ; Ki Hyun KIM ; Seong Eun KIM ; Young Ki SON ; Won Suk ANN
Kidney Research and Clinical Practice 2013;32(1):21-26
BACKGROUND: Niacin supplementation improves dyslipidemia and lowers serum phosphorus levels in patients with chronic kidney disease (CKD). We evaluated whether low-dose niacin supplementation can improve dyslipidemia, lower serum phosphorus levels, and be administered with a low frequency of adverse effects in patients with CKD. METHODS: We retrospectively analyzed the clinical records of patients with CKD who had taken niacin from January 2009 to June 2011. We excluded patients with CKD stage 1 and 5. We then enrolled 31 patients with CKD who had taken niacin at a fixed dose of 500mg/day for 6 months. We also randomly selected 30 patients with CKD who had been taking statin for 9 months as a control group. RESULTS: Among the 34 patients with CKD who were prescribed niacin, five (14%) complained of adverse effects, and three (8%) discontinued niacin. The proportion of patients in the niacin group who had been taking a statin or omega-3 fatty acids was 67.7% and 48.8%, respectively. In the niacin group, high-density lipoprotein cholesterol level was significantly increased and triglyceride level was significantly decreased at 12 and 24 weeks compared with baseline levels (P < 0.05). In the niacin group, phosphorous level (P < 0.05) was significantly decreased, and glomerular filtration rate (GFR) was significantly increased (P < 0.05) at 24 weeks compared with baseline values. CONCLUSION: Low-dose niacin had a low frequency of adverse effects and also improved dyslipidemia, lowered serum phosphorus level, and increased GFR in patients with CKD. Further studies are needed to evaluate the long-term effects of low-dose niacin for renal progression of CKD.
Cholesterol
;
Dyslipidemias
;
Fatty Acids, Omega-3
;
Glomerular Filtration Rate
;
Humans
;
Hydroxymethylglutaryl-CoA Reductase Inhibitors
;
Lipoproteins
;
Niacin
;
Phosphorus
;
Renal Insufficiency, Chronic
;
Retrospective Studies
5.Effects of low-dose niacin on dyslipidemia and serum phosphorus in patients with chronic kidney disease.
Hyo Jin KANG ; Do Kyong KIM ; Su Mi LEE ; Kyung Han KIM ; Seung Hee HAN ; Ki Hyun KIM ; Seong Eun KIM ; Young Ki SON ; Won Suk ANN
Kidney Research and Clinical Practice 2013;32(1):21-26
BACKGROUND: Niacin supplementation improves dyslipidemia and lowers serum phosphorus levels in patients with chronic kidney disease (CKD). We evaluated whether low-dose niacin supplementation can improve dyslipidemia, lower serum phosphorus levels, and be administered with a low frequency of adverse effects in patients with CKD. METHODS: We retrospectively analyzed the clinical records of patients with CKD who had taken niacin from January 2009 to June 2011. We excluded patients with CKD stage 1 and 5. We then enrolled 31 patients with CKD who had taken niacin at a fixed dose of 500mg/day for 6 months. We also randomly selected 30 patients with CKD who had been taking statin for 9 months as a control group. RESULTS: Among the 34 patients with CKD who were prescribed niacin, five (14%) complained of adverse effects, and three (8%) discontinued niacin. The proportion of patients in the niacin group who had been taking a statin or omega-3 fatty acids was 67.7% and 48.8%, respectively. In the niacin group, high-density lipoprotein cholesterol level was significantly increased and triglyceride level was significantly decreased at 12 and 24 weeks compared with baseline levels (P < 0.05). In the niacin group, phosphorous level (P < 0.05) was significantly decreased, and glomerular filtration rate (GFR) was significantly increased (P < 0.05) at 24 weeks compared with baseline values. CONCLUSION: Low-dose niacin had a low frequency of adverse effects and also improved dyslipidemia, lowered serum phosphorus level, and increased GFR in patients with CKD. Further studies are needed to evaluate the long-term effects of low-dose niacin for renal progression of CKD.
Cholesterol
;
Dyslipidemias
;
Fatty Acids, Omega-3
;
Glomerular Filtration Rate
;
Humans
;
Hydroxymethylglutaryl-CoA Reductase Inhibitors
;
Lipoproteins
;
Niacin
;
Phosphorus
;
Renal Insufficiency, Chronic
;
Retrospective Studies
6.Practice guideline for the performance of breast ultrasound elastography.
Su Hyun LEE ; Jung Min CHANG ; Nariya CHO ; Hye Ryoung KOO ; Ann YI ; Seung Ja KIM ; Ji Hyun YOUK ; Eun Ju SON ; Seon Hyeong CHOI ; Shin Ho KOOK ; Jin CHUNG ; Eun Suk CHA ; Jeong Seon PARK ; Hae Kyoung JUNG ; Kyung Hee KO ; Hye Young CHOI ; Eun Bi RYU ; Woo Kyung MOON
Ultrasonography 2014;33(1):3-10
Ultrasound (US) elastography is a valuable imaging technique for tissue characterization. Two main types of elastography, strain and shear-wave, are commonly used to image breast tissue. The use of elastography is expected to increase, particularly with the increased use of US for breast screening. Recently, the US elastographic features of breast masses have been incorporated into the 2nd edition of the Breast Imaging Reporting and Data System (BI-RADS) US lexicon as associated findings. This review suggests practical guidelines for breast US elastography in consensus with the Korean Breast Elastography Study Group, which was formed in August 2013 to perform a multicenter prospective study on the use of elastography for US breast screening. This article is focused on the role of elastography in combination with B-mode US for the evaluation of breast masses. Practical tips for adequate data acquisition and the interpretation of elastography results are also presented.
Breast*
;
Consensus
;
Elasticity Imaging Techniques*
;
Information Systems
;
Mass Screening
;
Ultrasonography*