1.A study on CT brain scanning of the patients without neurologicsigns in the patient group who had visited an emergency room.
Seon Hyang JANG ; Nam Hyen CHOI ; Jong Tae CHOI ; Eui Shik CHUNG
Journal of the Korean Academy of Family Medicine 1991;12(8):28-37
No abstract available.
Brain*
;
Emergencies*
;
Emergency Service, Hospital*
;
Humans
2.Two Cases of Graves Disease Associated The Empty Sella Syndrome
Yeun Jong CHOI ; Hong Seung KIM ; Eui Ryun PARK ; Young Gu SHIN ; Choon Hee CHUNG
Journal of Korean Society of Endocrinology 1996;11(4):517-522
The empty sella syndrome is characterized by obesity, frequent pregnancy, headache and high blood pressure, but its exact cause remains unknown. Usually the incomplete diaphragmatic sella has been considered as the cause of the empty sella syndrome, but some authors recently have suggested that the antipituitary antibody way be related to development of pituitary atrophy and the pituitary empty sella syndrome, and thus it may be clinically useful as screening test for the empty sella syndrome. We experienced two empty sella syndromes associated Graves disease and applied the antipituitary antibody as the diagnostic tool of the empty sella syndrome. But none of this two patients had antipituitary antibody and we report these cases with reviews of literatures.
Atrophy
;
Empty Sella Syndrome
;
Graves Disease
;
Headache
;
Humans
;
Hypertension
;
Mass Screening
;
Obesity
;
Pregnancy
3.The relationship between medical students' epistemological beliefs and achievement on a clinical performance examination.
Sun A OH ; Eun Kyung CHUNG ; Eui Ryoung HAN ; Young Jong WOO ; Deiter KEVIN
Korean Journal of Medical Education 2016;28(1):29-34
PURPOSE: This study was to explore the relationship between clinical performance examination (CPX) achievement and epistemological beliefs to investigate the potentials of epistemological beliefs in ill-structured medical problem solving tasks. METHODS: We administered the epistemological beliefs questionnaire (EBQ) to fourth-year medical students and correlated the results with their CPX scores. The EBQ comprised 61 items reflecting five belief systems: certainty of knowledge, source of knowledge, rigidity of learning, ability to learn, and speed of knowledge acquisition. The CPX included scores for history taking, physical examination, and patient-physician interaction. RESULTS: The higher epistemological beliefs group obtained significantly higher scores on the CPX with regard to history taking and patient-physician interaction. The epistemological beliefs scores on certainty of knowledge and source of knowledge were significantly positively correlated with patient-physician interaction. The epistemological beliefs scores for ability to learn were significantly positively correlated with those for history taking, physical examination, and patient-physician interaction. CONCLUSION: Students with more sophisticated and advanced epistemological beliefs stances used more comprehensive and varied approaches in the patient-physician interaction. Therefore, educational efforts that encourage discussions pertaining to epistemological views should be considered to improve clinical reasoning and problem-solving competence in the clinic setting.
*Achievement
;
Adult
;
*Attitude
;
*Clinical Competence
;
*Culture
;
*Education, Medical, Undergraduate
;
Educational Measurement
;
Female
;
Humans
;
*Knowledge
;
Male
;
Medical History Taking
;
Physical Examination
;
Physician-Patient Relations
;
Problem-Based Learning
;
Republic of Korea
;
Schools, Medical
;
*Students, Medical
;
Surveys and Questionnaires
;
Thinking
;
Young Adult
4.Medical Residents' Job Satisfaction and Their Related Factors.
Eun Kyung CHUNG ; Eui Ryoung HAN ; Young Jong WOO
Korean Journal of Medical Education 2013;25(1):39-46
PURPOSE: This study was conducted to investigate medical residents' job satisfaction and their related factors to improve the quality of residency program. METHODS: The study subjects were 159 medical residents being trained at Chonnam National University Hospital, South Korea, in 2011. The participants were asked to complete a short form Minnesota satisfaction questionnaire (MSQ). RESULTS: The mean score for 20 items on the short form MSQ varied between 2.91 and 3.64 on a 5-point Likert scale. The assessment of related factors with job satisfaction revealed that medical residents had higher levels for job satisfaction, particularly those who were women (beta=0.200, p=0.022), and those who had mentorship experience (beta=0.219, p=0.008). CONCLUSION: This study results indicate that we should expand and support the mentorship program during medical residency to promote job satisfaction.
Female
;
Humans
;
Internship and Residency
;
Job Satisfaction
;
Mentors
;
Minnesota
;
Republic of Korea
;
Surveys and Questionnaires
5.Clinical Investigation of P Wave Amplitude and Atrial Synchronous Ventricular Pacing in Different Body Position and Physical Activity with a Single-Pass Lead VDD Pacing.
Kyung Eui KANG ; Chung Whee CHOUE ; Heung Sun KANG ; Kwon Sam KIM ; Jung Sang SONG ; Jong Hwa BAE
Korean Circulation Journal 1999;29(10):1082-1088
BACKGROUND: Single pass lead VDD pacing preserves atrioventricular synchrony with a single lead system which incorporates floating atrial electrodes. The objectives of this study were to measure whether different body postures and physical activities cause significant changes of the atrial electrogram amplitudes and to evaluate the effectiveness of its atrial sensing, ventricular sensing and pacing. METHOD: Prospective study was done in 7 patients with high degree AV block and normal sinus node function in whom a single lead VDD pacing system was implanted. The P wave amplitude was been measured in different condition during follow-up period. RESULTS: 1) During follow-up period, the P wave amplitude showed variation with changes in posture and respiration, but there was no consistent increase or decrease in amplitude. The lowest P wave amplitude was above the minimal atrial sensing value of 0.2 mV. 2) The percentage of atrial synchronous ventricular pacing recorded in Holter ECG and during Treadmill exercise test was more than 99%. 3) Atrial oversensing or VA cross sensing were not observed in any of the patients. CONCLUSIONS: Despite floating atrial electrode, the single pass lead VDD pacing maintains reliable atrial sensing and ventricular pacing in different body position and physical activity, so it may offer an excellent alternative in patients with high grade AV block and intact sinus node function.
Atrioventricular Block
;
Electrocardiography
;
Electrodes
;
Electrophysiologic Techniques, Cardiac
;
Exercise Test
;
Follow-Up Studies
;
Humans
;
Motor Activity*
;
Posture
;
Prospective Studies
;
Respiration
;
Sinoatrial Node
6.Clinical Investigation of P Wave Amplitude and Atrial Synchronous Ventricular Pacing in Different Body Position and Physical Activity with a Single-Pass Lead VDD Pacing.
Kyung Eui KANG ; Chung Whee CHOUE ; Heung Sun KANG ; Kwon Sam KIM ; Jung Sang SONG ; Jong Hwa BAE
Korean Circulation Journal 1999;29(10):1082-1088
BACKGROUND: Single pass lead VDD pacing preserves atrioventricular synchrony with a single lead system which incorporates floating atrial electrodes. The objectives of this study were to measure whether different body postures and physical activities cause significant changes of the atrial electrogram amplitudes and to evaluate the effectiveness of its atrial sensing, ventricular sensing and pacing. METHOD: Prospective study was done in 7 patients with high degree AV block and normal sinus node function in whom a single lead VDD pacing system was implanted. The P wave amplitude was been measured in different condition during follow-up period. RESULTS: 1) During follow-up period, the P wave amplitude showed variation with changes in posture and respiration, but there was no consistent increase or decrease in amplitude. The lowest P wave amplitude was above the minimal atrial sensing value of 0.2 mV. 2) The percentage of atrial synchronous ventricular pacing recorded in Holter ECG and during Treadmill exercise test was more than 99%. 3) Atrial oversensing or VA cross sensing were not observed in any of the patients. CONCLUSIONS: Despite floating atrial electrode, the single pass lead VDD pacing maintains reliable atrial sensing and ventricular pacing in different body position and physical activity, so it may offer an excellent alternative in patients with high grade AV block and intact sinus node function.
Atrioventricular Block
;
Electrocardiography
;
Electrodes
;
Electrophysiologic Techniques, Cardiac
;
Exercise Test
;
Follow-Up Studies
;
Humans
;
Motor Activity*
;
Posture
;
Prospective Studies
;
Respiration
;
Sinoatrial Node
7.The Correlations between Donor Endothelial Lenticule Thickness and Visual Prognosis in DSAEK.
Jong Chul HAN ; Ji Hyun BAE ; Tae Young CHUNG ; Eui Sang CHUNG
Journal of the Korean Ophthalmological Society 2013;54(2):210-214
PURPOSE: To determine the correlations between donor endothelial lenticule thickness and visual prognosis in Descemet's stripping automated endothelial keratoplasty (DSAEK). METHODS: The present study included 22 patients (22 eyes), who underwent DSAEK surgery in our clinic due to endothelial decompensation. BCVA (log MAR) was compared at 1 month, 3 months and 6 months postoperatively between the thin lenticule group and thick lenticule group (> or =130 micrometer). RESULTS: The BCVA (log MAR) at 1 month postoperatively was 0.46 +/- 0.22 in the thin lenticule group, and 0.71 +/- 0.26 in the thick lenticule group, and significant statistical correlations between donor lenticule thickness and visual acuity were observed (p = 0.025). However, no significant correlations were observed at 3 months (p = 0.129) and 6 months (p = 0.141) postoperatively. CONCLUSIONS: The thin donor lenticule (<130 micrometer) can result in better visual acuity at 1 month postoperatively than the thick donor lenticule (> or =130 micrometer), however, there is no difference in visual acuity between the 2 groups at 3 and 6 months postoperatively.
Corneal Transplantation
;
Humans
;
Prognosis
;
Tissue Donors
;
Visual Acuity
8.Three cases of posterior circulation infarction related with cervical manipulation or trauma.
Key Chung PARK ; Sang Soo YOON ; Jung Hyuk PARK ; Dae Il CHANG ; Eui Jong KIM ; Woo Suck CHOI ; Kyung Cheon CHUNG
Journal of the Korean Neurological Association 1997;15(4):858-866
BACKGROUND AND SIGNIFICANCE: Neck manipulation or trauma uncommonly be associated with serious and even fatal vascular complications. We presented the clinical and radiologic findings in 3 patients of brainstem and/or cerebellar infarct with basilar artery occlusion and extracranial vertebral artery stenosis or occlusion,. Cases : In the patient 1, the infarction of pons and lsft cerebellar hemisphere outbroke just after being seized by the collar. The angiographic findings were complete occlusion of basilar artery and left vertebral artery on C1 level and vertebrobasilar junctional occlusion of right vertebral artery. In the patient 2, extensive infarction of pons and left cerebellar hemisphere developed just after chiropractic manipulation of the neck. The angiographic findings were occlusions of left vertebral artery and distal portion of the basilar artery. In the patient 3, right cerebellar and medullary infarction of posteroinferior cerebellar artery territory occurred just after autobicycle accident. The angiographic finding was complete occlusion of left vertebral artery on C1 lever. They had not another risk factor of the stroke. CONCLUSIONS: We experienced and presented 3 cases of posterior circulation infarctio with vertebrobasilar stenoocclusion just following cervical manipulation or neck trauma.
Arteries
;
Basilar Artery
;
Brain Stem
;
Humans
;
Infarction*
;
Manipulation, Chiropractic
;
Manipulation, Spinal*
;
Neck
;
Pons
;
Risk Factors
;
Stroke
;
Vertebral Artery
;
Vertebrobasilar Insufficiency
9.Cases of Hemolytic Anemia with Periprosthetic Leaks Evaluated by Real-Time 3-Dimensional Transesophageal Echocardiography.
Eui Jong CHUNG ; Tae Yop KIM ; Jong Min HWANG ; Sang Phil KIM ; Hyun Suk YANG
Journal of Cardiovascular Ultrasound 2012;20(1):52-56
Hemolytic anemia is recognized as a rare complication of mitral valve replacement or repair. We report on a 44-year-old man with shortness of breath and hemolytic anemia, 23 years after mitral valve replacement (Hall-Kaster), and a 63-year-old woman diagnosed of hemolytic anemia, 4 years after mitral and tricuspid annuloplasty (Tailor ring, An-core ring). Routine 2-dimensional transthoracic echocardiography revealed paravalvular leakage around the prosthesis. Subsequent real-time 3-dimensional (3D)transesophageal echocardiography helped the perceptional appreciation of the leakage and the measuring of the regurgitant orifice area using the anatomically correct plane. Surgical findings of each case fit those of 3D volumetric images.
Adult
;
Anemia, Hemolytic
;
Dyspnea
;
Echocardiography
;
Echocardiography, Three-Dimensional
;
Echocardiography, Transesophageal
;
Female
;
Humans
;
Middle Aged
;
Mitral Valve
;
Prostheses and Implants
10.Cases of Hemolytic Anemia with Periprosthetic Leaks Evaluated by Real-Time 3-Dimensional Transesophageal Echocardiography.
Eui Jong CHUNG ; Tae Yop KIM ; Jong Min HWANG ; Sang Phil KIM ; Hyun Suk YANG
Journal of Cardiovascular Ultrasound 2012;20(1):52-56
Hemolytic anemia is recognized as a rare complication of mitral valve replacement or repair. We report on a 44-year-old man with shortness of breath and hemolytic anemia, 23 years after mitral valve replacement (Hall-Kaster), and a 63-year-old woman diagnosed of hemolytic anemia, 4 years after mitral and tricuspid annuloplasty (Tailor ring, An-core ring). Routine 2-dimensional transthoracic echocardiography revealed paravalvular leakage around the prosthesis. Subsequent real-time 3-dimensional (3D)transesophageal echocardiography helped the perceptional appreciation of the leakage and the measuring of the regurgitant orifice area using the anatomically correct plane. Surgical findings of each case fit those of 3D volumetric images.
Adult
;
Anemia, Hemolytic
;
Dyspnea
;
Echocardiography
;
Echocardiography, Three-Dimensional
;
Echocardiography, Transesophageal
;
Female
;
Humans
;
Middle Aged
;
Mitral Valve
;
Prostheses and Implants