1.Coumarins from Peucedanum harry-smithii var. subglabrum.
Wen LI ; Shilan FENG ; Fangdi HU ; Erlin CHEN
China Journal of Chinese Materia Medica 2009;34(10):1231-1234
The root of Peucedanum harry-smithii var. subglabrum was extracted with methanol, then separated with solvents at different polarity into four fractions: aqueous (H2O), ethyl acetate (AcOEt), chloroform (CHCl3) and petroleum ether (DAB-6). From AcOEt psoralen, bargapten, xanthotoxin, marmesin, umbelliferone, scopoletin, (+/-) peuformosin, Pd-I b, (+/-) selinidin, praeruptorin D were isolated by column chromatography on silica gel, using petroleum ether/ethyl acetate as eluent. The structures of the coumarins were identified by 1H-NMR and 13C-NMR.
Apiaceae
;
chemistry
;
Coumarins
;
chemistry
;
isolation & purification
;
Magnetic Resonance Spectroscopy
;
methods
;
Plant Roots
;
chemistry
;
Umbelliferones
;
chemistry
2.Risk factors for axial deviation in treatment of tibial bone defects by bone transport with Orthofix unilateral external fixator
Dongwei FENG ; Yaxin ZHANG ; Yanshi LIU ; Xuefeng LUO ; Erlin CHENG ; Qiyu JIA ; Dongsheng CHEN ; Jian GUO ; Chuang MA
Chinese Journal of Orthopaedic Trauma 2022;24(6):471-477
Objective:To investigate the risk factors for axial deviation in the treatment of tibial defect susing Orthofix unilateral external fixator and proximal tibial osteotomy for bone transport.Methods:A retrospective study was performed to analyze the clinical data of 90 patients who had been treated for tibial bone defects by the Orthofix unilateral external fixator at Department of Microrepair and Reconstruction, The First Hospital Affiliated to Xinjiang Medical University from May 2012 to June 2019. There were 77 males and 13 females with a mean age of 41.2 years (from 17 to 63 years).The bone defects ranged from 4 to 13 cm in length. According to the Paley criteria for axial deviation, the 90 patients were divided into 2 groups: a deviation-free group with no axial deviation or an axial deviation ≤5° and a deviation group with an axial deviation>5°. The 2 groups were compared in terms of age, number of prior surgery, defect length, placement angle of Schanz screws, external fixation time, external fixation index and bending degree of Schanz screws at the last follow-up.The factors with P<0.05 were analyzed by multivariate logistic regression to find the risk factors for coronal axial deviation. Results:The 90 patients were followed up for an average of 23 months (from 12 to 40 months). The incidence of axial deviation in this cohort was 36.7% (33/90).The deviation group had a significantly larger number of prior surgery [5 (3, 6) times], a significantly longer defect length [8 (8, 9) cm], a significantly longer external fixation time [400.0 (341.8, 426.3) d], and a significantly greater bending degree of Schanz screws at the last follow-up [1.2° (0.4°, 3.5°)] than the deviation-free group [3 (2, 3) times, 6 (5, 8) cm, 340.8 (226.5, 422.8) d, and 0.8° (0.2°, 3.7°)] (all P<0.05). Multivariate logistic regression analysis showed that the number of prior surgery ( OR=2.581, 95% CI: 1.496-4.450, P=0.001) and the defect length ( OR=5.310, 95% CI: 1.952-14.442, P=0.001) were the risk factors for the axial deviation. Conclusion:In the treatment of tibial defect susing Orthofix unilateral external fixator and proximal tibial osteotomy for bone transport, the more prior surgeries and the longer a bone defect, the higher the risk for axial deviation.
3.A unified deep-learning network to accurately segment insulin granules of different animal models imaged under different electron microscopy methodologies.
Xiaoya ZHANG ; Xiaohong PENG ; Chengsheng HAN ; Wenzhen ZHU ; Lisi WEI ; Yulin ZHANG ; Yi WANG ; Xiuqin ZHANG ; Hao TANG ; Jianshe ZHANG ; Xiaojun XU ; Fengping FENG ; Yanhong XUE ; Erlin YAO ; Guangming TAN ; Tao XU ; Liangyi CHEN
Protein & Cell 2019;10(4):306-311