1.Comparison of four malignancy risk indices in the detection of malignant ovarian masses.
Erhan AKTURK ; Riza Efendi KARACA ; Ibrahim ALANBAY ; Murat DEDE ; Emre KARASAHIN ; Mufit Cemal YENEN ; Iskender BASER
Journal of Gynecologic Oncology 2011;22(3):177-182
OBJECTIVE: The aim of this study was to evaluate the ability of four risk of malignancy indices (RMI) to detect malignant ovarian tumors. METHODS: This is a prospective study of 100 women admitted to the Department of Obstetrics and Gynecology of Gulhane Military Medicine Academy for surgical exploration of pelvic masses. To diagnose malignant ovarian tumors, the sensitivity, specificity, negative and positive predictive values and diagnostic accuracy of four RMIs (RMI 1, RMI 2, RMI 3, and RMI 4) were obtained. RESULTS: In our study we found that there is no statistically significant difference in the performance of four different RMIs in discriminating malignancy. We think that malignancy risk indices is more reliable than the menopausal status, serum CA-125 levels, ultrasound features and tumor size separately in detecting malignancy. CONCLUSION: We concluded that any of the four malignancy risk indices described can be used for selection of cases for optimal therapy. These methods are simple techniques that can be used even in less-specialized gynecology clinics to facilitate the selection of cases for referral to an oncological unit.
Female
;
Gynecology
;
Humans
;
Military Medicine
;
Obstetrics
;
Ovarian Neoplasms
;
Prospective Studies
;
Referral and Consultation
;
Sensitivity and Specificity
2.Evaluation of corrosion resistance of Co-Cr alloys fabricated with different metal laser sintering systems
Süleyman Hakan TUNA ; Erhan KARACA ; İsmail ASLAN ; Gürel PEKKAN ; Nuran Özçiçek PEKMEZ
The Journal of Advanced Prosthodontics 2020;12(3):114-123
PURPOSE:
. The aim of this study was to evaluate the corrosion resistance of the specimens produced by five different commercial metal laser sintering (MLS) systems with their recommended Co-Cr alloy powders.
MATERIALS AND METHODS:
. The MLS machines and the alloy powders used were, ProX 100-ST2724G (St-Pro), Mysint 100-EOS SP2 (SP2-Mys), EOSINT 270-EOS SP2 (SP2-EOS), SLM 100-Starbond CoS (SB-SLM), and MLab Cusing-Remanium® Star (RS-MLab), respectively. Eight specimens from each group were prepared. Open circuit potential (Eocp) and electrochemical impedance spectroscopy (EIS) measurements of polished surfaces of the specimens were conducted in a three-electrode cell using a potentiostat-galvanostat in Fusayama-Meyer artificial saliva (AS). Specimens from each group were immersed in AS and de-ionized water for seven days. Eocp, charge transfer resistance (Rct) values, and released ions (μg/cm2 × 7d) in different solutions were determined. The specimen surfaces were observed with SEM/EDS. Results were analyzed statistically.
RESULTS:
. Eocp values have shifted to potentials that are more positive over time. Steady-state Eocp values were from high to low as follows, SB-SLM, SP2-Mys, SP2-EOS, RS-MLab, and ST-Pro, respectively. After 60 mins, RS-MLab specimens had the highest Rct value, followed by SP2-Mys, SB-SLM, SP2-EOS, and ST-Pro. In all groups, ion release was higher in AS than that in de-ionized water.
CONCLUSION
. There were small differences among the corrosion resistances of the Co-Cr alloy specimens produced with MLS systems; meanwhile, the corrosion resistances were quite high for all specimens.