2.Appraisal of occupational stressor in petrochemical industry workers.
Xiao-ping TANG ; Hong-er TIAN ; Tong HUANG ; Zhi-yuan LI ; Ke-ming HU ; Xi-yong GE ; Lei JIN ; Qi GAO ; Jing-jing ZHANG ; Yu WANG ; Wen-he LIU
Chinese Journal of Industrial Hygiene and Occupational Diseases 2009;27(12):730-733
OBJECTIVETo discuss the origin of occupational stress among petrochemical industry workers and to access the main occupational stressors that impact job satisfaction and mental health of petrochemical industry workers.
METHODSA survey on occupational stressor was carried out by Occupational Stress Indicator (OSI) in 532 petrochemical industry workers (345 chemical and 187 logistic workers).
RESULTSThe environment in workplace of chemical group was worse than that of contrast. The chemical workers had less control over job and they experienced more hazards, monotonous as well as role stressors than the logistic group. The scores of job satisfaction and mental health of chemical group (36.867 +/- 0.656, 43.734 +/- 0.542, respectively) were higher than that of contrast (40.321 +/- 0.901, 46.714 +/- 0.745, respectively) (P < 0.05).
CONCLUSIONThe occupational stressors exist in chemical workers which affect chemical workers' job satisfaction and mental health with different levels.
Adult ; Analysis of Variance ; Burnout, Professional ; Chemical Industry ; Female ; Humans ; Job Satisfaction ; Male ; Middle Aged ; Petroleum ; Regression Analysis ; Young Adult
3.Analysis on hepatitis C virus genotypes among 118 HCV-infected patients in Xinjiang region.
Abuduheilili Xi ER-NAYI ; Guang-Ying SHI ; Shuang SHI ; Fang-Ping HE ; Feng LU ; Jie WANG ; Yue-Xin ZHANG ; Hui ZHUANG
Chinese Journal of Hepatology 2011;19(2):127-128
Not Abstract.
4.Role of Treg in the immune pathogenesis of subacute thyroiditis
Xiao-Ling WANG ; He-Zuo LYU ; Huai-Yong GAN ; Ping XIANG ; Xiao-Feng HANG ; Er-Qin XU ; Xiao-Yan PEI ; Guo-Xi JIN
Basic & Clinical Medicine 2018;38(2):218-223
Objective To explore the role of regulatory T-lymphocytes(Treg) in the immune pathogenesis of suba-cute thyroiditis (SAT). Methods The proportion of Treg in CD4+T cells in peripheral blood of 46 SAT patients and15 controls was detected using flow cytometry. And the concentration of interleukin-10(IL-10), transforming growth factor-beta1(TGF-β1) and prostaglandin E2(PGE2) in serum of 46 SAT patients and 15 controls was measured with ELISA. In addition, the Forkhead box protein 3 (Foxp3) positive cells in thyroid tissue of 29 SAT patients and20 controls was detected by immunohistochemistry. Results The proportion of Treg in peripheral blood of SAT pa-tients was significantly lower than that of controls (P<0.05). And the concentration of TGF-β1 in serum of SAT patients was apparently higher than that of controls(P<0.05). Additionally, the positive rate of Foxp3 in thyroid tissue of SAT patients was markedly higher than that of controls(P<0.05).Conclusions The decrease of Treg may play an important role in the immune pathogenesis of SAT.
5.Development of LabVIEW-based loading system for cellular shear stress and its experimental validation
dong Ze YAN ; ping Er LUO ; Pan WANG ; wan Meng LIU ; ming Ming ZHAI ; hui Xu ZHANG ; yu Xi LIU ; Da JING
Chinese Medical Equipment Journal 2017;38(11):5-9
Objective To develop a cellular shear stress loading system with an adjustable stress mode and relevant parameters, and subsequently verify the effectiveness and feasibility of this system. Methods The hardware of the system was developed by using a peristaltic pump and self-designed multi-channel flow chamber, and the mode control program of shear stress based on LabVIEW was designed to control the device via RS485 interfacing and Modbus protocol. Additionally, the relationship between the shear stress and system parameters was calibrated, and finite element analysis was also conducted. Finally, the feasibility of the system was confirmed via the in vitro cell experiment. Results The mode and magnitude of shear stress of the system could be controlled via either the peristaltic pump or computer, and the cellular long-term effect was also able to be detected. The calibration results of the system indicated that the level of shear stress exhibited significantly linear positive correlation with the revolution of the peristaltic pump (P<0.001). Finite element analysis demonstrated that the level of shear stress on the slide was uniformly distributed and the result of simulation was accordant with calibration. Cytoskeleton staining suggested that cellular morphology of MLO-Y4 cells was changed, and microfilament increased and arrayed along fluid flow direction. Conclusion The system is stable and reliable enough to provide different loading modes and magnitude of cellular shear stress to offer a convictive platform of the research for different cellular stress signal transduction mecha-nisms.
6.Establishment and validation for a 3D finite element model of cervicothoracic junction C5-T2
Gai-ping ZHAO ; Xin-guo FANG ; Chen-xi WANG ; Lei-lei BAI ; Qing-hua ZHAO ; Shi-xiong XU ; Er-yun CHEN
Journal of Medical Biomechanics 2015;30(1):E056-E061
Objective To establish a 3D finite element model of cervicothoracic spinal segments C5-T2 based on CT images and test its validity and effectiveness. Methods By using the Mimics, Geomagic and Hypermesh software, the 3D model of cervicothoracic spinal segments C5-T2 was reconstructed, repaired and pre-processed. Moment of ±0.5, 1, 1.5, 2 N•m were applied on top of the model to simulate loads produced during the flexion and extension movement of human body. The range of motion (ROM) of the segments C5-T2 during flexion and extension was calculated by ANSYS, and the reliability of the model was verified by comparing the experimental results in the previous literature with the finite element analysis results obtained in this study. Results Under the moment of 1 N•m, the ROMs of C5-6, C6-7, C7-T1 and T1-2 during flexion were 4.30°,3.21°,1.66° and 1.41°, and those during extension were 3.47°, 2.86°, 0.96° and 0.92°, respectively. The maximum stress during flexion appeared on the front of the vertebral body, while that during extension appeared on the back of the vertebral body. The trends of ROM and stress distributions were consistent with results reported in the previous literature. Conclusions The 3D model established in this study is accurate and realistic, and conforms to biomechanical properties of the cervicothoracic spine. The simulation results can be further used to explore clinical pathology of the spine and provide theoretical references for evaluation on cervicothoracic spine surgery.
7.Finite element analysis on different spine reconstruction methods after total spondylectomy of cervicothoracic spine
Xin-guo FANG ; Gai-ping ZHAO ; Chen-xi WANG ; Lei-lei BAI ; Er-yun CHEN ; Qing-hua ZHAO
Journal of Medical Biomechanics 2015;30(3):E220-E225
Objective To establish 3D finite element of human cervicothoracic spine C5-T2 based on CT images, and explore effects on stability of the cervicothoracic spine after total spondylectomy (TS) by using various combinations of internal fixation devices (pedicle screw, titanium mesh, steel plate), including the stress distributions on these internal fixation devices. Methods The intact finite element model of cervicothoracic spine C5-T2 was established and validated by comparing the model’s range of motion (ROM) with that of other in vitro experiments. Then four reconstruction models after TS of cervical spine segment C7 were established: TM+AP+DPS model (titanium mesh + anterior plate + posterior double-segmental pedicle screw), TM+AP+SPS model (titanium mesh + anterior plate + posterior single-segmental pedicle screw), TM+DPS model (titanium mesh + posterior double-segmental pedicle screw), AP+DPS model (anterior plate + posterior double-segmental pedicle screw). ROM of each reconstruction model under flexion, extension, lateral bending and rotation and stress distributions on these internal fixation devices were then analyzed. Results ROM of the reconstruction segments was greatly reduced by over 93% as compare to that of the intact model. Stress concentration phenomenon appeared on the titanium mesh in the TM+AP+SPS model. Conclusions The fixation effects of four reconstruction models are similar. Stresses on 3 DPS fixed-models are more evenly distributed, indicating that the overall stability of DPS fixed-model is superior to that of SPS fixed-model.
8.Finite element analysis on inferior cervical spine biomechanics after semi-constrained cervical intervertebral disc arthroplasty and anterior cervical discectomy and fusion
Lei-lei BAI ; Gai-ping ZHAO ; Cheng-xi WANG ; Nan-xin CHEN ; Yan-mei SONG ; Er-yun CHEN ; Qing-hua ZHAO
Journal of Medical Biomechanics 2016;31(3):E247-E253
Objective To study biomechanical properties such as range of motion (ROM), intervertebral disc stress, ligament tension of inferior cervical spinal segment after the treatment of Discover, Prodisc-C artificial intervertebral disc replacement, and anterior cervical discectomy and fusion (ACDF), as well as mechanical property changes of the prosthesis after implantation. Methods Three kinds of operation plan on C5-6 cervical disc degeneration were established: Discover model, Prodisc-C model and ACDF model, as well as C4-7 segment original model of cervical vertebra. Biomechanical property changes after operation in cervical spine C4-7 segment in sagittal, coronal and transverse section were analyzed. Results ROM changes of cervical segment C5-C6 were as following: in Discover model it increased by 12.7%-73.1%, Prodisc-C model increased by 74%-98%, ACDF decreased by 55.8%-71.8%. The stress of C4-5 intervertebral disc after Discover artificial disc replacement showed no obvious increase, while the stress of C6-7 intervertebral disc decreased by 33.2%-54.2% under flexion, extension and axial rotation conditions. The amplification of ligament tension in Discover model decreased by 30%-40% as compared to that in Prodisc-C model. The maximum stress of Discover model (36.72 MPa) appeared under flexion condition, which was smaller than that in Prodisc-C model. Conclusions Artificial disc replacement can help to keep movement performance for segment after surgery. As a newly developed artificial intervertebral disc prosthesis, Discover makes some progress in the aspect of decreasing ligament stress and maintaining spinal stability. The research findings will provide theoretical basis for the clinical study on ACDF and artificial cervical intervertebral disc replacement surgeries.
9.Preliminary establishment of integration of Alzheimer's disease and blood stasis syndrome tree shrew model and evaluation of intervention of Panax notoginseng saponins.
Ben CHEN ; Mei-Chun QIN ; Jin-Lan HUANG ; Deng-Pan WU ; Er-Chu GUO ; Zhi-Ping LIU ; Zhe-Hao XU ; Xi-Xi GUO ; Zhen-Guo ZHONG
China Journal of Chinese Materia Medica 2017;42(6):1175-1182
To establish the integration of Alzheimer's disease(AD) and blood stasis syndrome tree shrew model. Panax notoginseng saponins (PNS) was used to intervene the model to testify the stability of the model. The level of blood stasis of each group in the tree shrew model was evaluated by analyzing five traditional Chinese medicine(TCM) characterizations, four blood coagulation indexes, plasma nitric oxide (NO) level, plasma superoxide dismutase (SOD) level in each group. Hematoxylin and eosin(HE) staining was used to observe the morphological changes of brain hippocampal neuron cell of each group. Immunohistochemical staining was used to assay the ChAT and SYP levels in brain hippocampus of each group.The blood stasis characterization of the integration of disease and syndrome group was more obvious than the AD group, and that of the drug administration group was lower than that of the integration of disease and syndrome group. Aβ1-42, APP, P-Tau, ChAT and SYP level of AD group were lower than those in the blank group, which were further reduced in the model of integration of disease and syndrome. However, the administration of PNS relieved the reduction, indicating that the AD and blood stasis integration syndrome tree shrew model is stable.
10.Role of Liquid-based Cytology and Cell Block in the Diagnosis of Endometrial Lesions.
Hui ZHANG ; Jia WEN ; Pi-Li XU ; Rui CHEN ; Xi YANG ; Lian-Er ZHOU ; Ping JIANG ; An-Xia WAN ; Qin-Ping LIAO
Chinese Medical Journal 2016;129(12):1459-1463
BACKGROUNDLiquid-based cytology (LBC) offers an alternative method to biopsy in screening endometrial cancer. Cell block (CB), prepared by collecting residual cytological specimen, represents a novel method to supplement the diagnosis of endometrial cytology. This study aimed to compare the specimen adequacy and diagnostic accuracy of LBC and CB in the diagnosis of endometrial lesions.
METHODSA total of 198 women with high risks of endometrial carcinoma (EC) from May 2014 to April 2015 were enrolled in this study. The cytological specimens were collected by the endometrial sampler (SAP-1) followed by histopathologic evaluation of dilatation and curettage or biopsy guided by hysteroscopy. The residual cytological specimens were processed into paraffin-embedded CB after LBC preparation. Diagnostic accuracies of LBC and CB for detecting endometrial lesions were correlated with histological diagnoses. Chi-square test was used to compare the specimen adequacies of LBC and CB.
RESULTSThe specimen inadequate rate of CB was significantly higher than that of LBC (22.2% versus 7.1%, P < 0.01). There were 144 cases with adequate specimens for LBC and CB preparation. Among them, 29 cases were atypical endometrial hyperplasia (11 cases) or carcinoma (18 cases) confirmed by histology evaluation. Taking atypical hyperplasia and carcinoma as positive, the diagnostic accuracy of CB was 95.1% while it was 93.8% in LBC. When combined LBC with CB, the diagnostic accuracy was improved to 95.8%, with a sensitivity of 89.7% and specificity of 97.4%.
CONCLUSIONSCB is a feasible and reproducible adjuvant method for screening endometrial lesions. A combination of CB and LBC can improve the diagnostic accuracy of endometrial lesions.
Adult ; Aged ; Biopsy ; methods ; Cross-Sectional Studies ; Cytodiagnosis ; methods ; Early Detection of Cancer ; methods ; Endometrial Hyperplasia ; diagnosis ; Endometrial Neoplasms ; diagnosis ; Endometrium ; pathology ; Female ; Humans ; Middle Aged ; Sensitivity and Specificity ; Specimen Handling