1.Trauma-induced pulmonary thromboembolism: What's update?
Chinese Journal of Traumatology 2022;25(2):67-76
Trauma-induced pulmonary thromboembolism is the second leading cause of death in severe trauma patients. Primary fibrinolytic hyperactivity combined with hemorrhage and consequential hypercoagulability in severe trauma patients create a huge challenge for clinicians. It is crucial to ensure a safe anticoagulant therapy for trauma patients, but a series of clinical issues need to be answered first, for example, what are the risk factors for traumatic venous thromboembolism? How to assess and determine the status of coagulation dysfunction of patients? When is the optimal timing to initiate pharmacologic prophylaxis for venous thromboembolism? What types of prophylactic agents should be used? How to manage the anticoagulation-related hemorrhage and to determine the optimal timing of restarting chemoprophylaxis? The present review attempts to answer the above questions.
Anticoagulants/adverse effects*
;
Hemorrhage
;
Humans
;
Pulmonary Embolism/prevention & control*
;
Risk Factors
;
Venous Thromboembolism/prevention & control*
2.Research on Shielding of Emboli with the Phase-Controlled Ultrasound.
Chinese Journal of Medical Instrumentation 2016;40(1):1-4
The postoperative neurological complications is associated with intraoperative cerebral emboli, which results from extracorporeal circulation and operation. It can effectively reduce the incidence of neurological complications with ultrasonic radiation. In fluids, a particle will change it's motion trail when it is acted by the radiation force generated by the ultrasound. This article mainly discuss how to shielding emboli with ultrasound. The equipment can transmit phased ultrasonic signals, which is designed on a FPGA development board. The board can generate a square wave, which is converted into a sine wave through a power amplifier. In addition, the control software has been developed on Qt development environment. The result indicates it's feasible to shielding emboli with ultrasonic radiation force. This article builds a strong foundation for the future research.
Humans
;
Intracranial Embolism
;
diagnostic imaging
;
prevention & control
;
Intraoperative Complications
;
prevention & control
;
Postoperative Complications
;
prevention & control
;
Ultrasonics
;
instrumentation
;
Ultrasonography
5.Fracture of a Tempofilter II: an Initial Case Report.
Hyung Jun KIM ; Nam Kyu CHANG ; Jae Hoon LIM ; Jae Kyu KIM
Korean Journal of Radiology 2011;12(5):626-628
Tempofilter II is a device that is used for pulmonary embolism prophylaxis. Since the appearance of the Tempofilter II following withdrawal of the Tempofilter I, it has been reported that the Tempofilter II is safe, effective and useful. Here we report on the first case of a fracture of one leg of the filter and this leg was embedded in the inferior vena cava wall in a 62-year-old man with deep vein thrombosis.
Device Removal
;
*Equipment Failure
;
Humans
;
Male
;
Middle Aged
;
Pulmonary Embolism/*prevention & control
;
*Vena Cava Filters
;
Venous Thrombosis/*complications/drug therapy
6.A Comparison of Infarct Size and Prognosis between Cardiogenic Embolic Infarction and Large Artery Atherosclerotic Infarction.
Ji Hoon JANG ; Byung Woo YOON ; Jae Kyu ROH
Journal of the Korean Neurological Association 2000;18(4):381-385
BACKGROUND: Cardiogenic embolic infarction is the most preventable type of ischemic stroke. This study was under-taken to compare the infarct size, prognosis, and risk factors between cardiogenic embolic infarction (CE) and large artery atherosclerotic infarction (LAA). METHODS:We reviewed the medical records and brain computed tomography/magnetic resonance image (CT/MRI) scans of patients with CE or LAA during the period between January 1996 and May 1998. Patients with lacunar and posterior circulation infarctions were excluded. A slice of brain CT/MRI scan showing the largest lesion was selected in each patient and the area of infarction was then measured. Prognosis was determined by the Modified Rankin Disability Scale (MRDS) and was grouped as either good (MDRS 0, 1, 2) or poor (MDRS 3, 4, 5). RESULTS: The study included 103 patients : 50 with CE (NVAF in 23, VHD with or without AF in 13, prosthetic valve in 6, and others in 8) and 53 with LAA (large artery thrombosis in 29, and artery to artery embolism in 24). The infarct size of CE (23.2+/-14.7 cm2) was significantly larger than that of LAA (11.4+/-10.5 cm2) (p<0.001). The infarct size of NVAF (29.0+/-19.1 cm2) was significantly larger than that of VHD with or without AF (19.2+/-11.5 cm2) (p<0.05). Patients with CE had a worse prognosis (poor in 46%) than those with LAA (poor in 23%) (p<0.05). CONCLUSIONS Our results showed that CE led to larger lesions and worse outcomes. Therefore, we emphasize the importance of primary and secondary preventions of stroke in patients with cardiogenic embolic sources.
Arteries*
;
Brain
;
Embolism
;
Heart Valve Diseases
;
Humans
;
Infarction*
;
Medical Records
;
Prognosis*
;
Risk Factors
;
Secondary Prevention
;
Stroke
;
Thrombosis
7.Carbon Dioxide Embolism during Laparoscopic Surgery.
Eun Young PARK ; Ja Young KWON ; Ki Jun KIM
Yonsei Medical Journal 2012;53(3):459-466
Clinically significant carbon dioxide embolism is a rare but potentially fatal complication of anesthesia administered during laparoscopic surgery. Its most common cause is inadvertent injection of carbon dioxide into a large vein, artery or solid organ. This error usually occurs during or shortly after insufflation of carbon dioxide into the body cavity, but may result from direct intravascular insufflation of carbon dioxide during surgery. Clinical presentation of carbon dioxide embolism ranges from asymptomatic to neurologic injury, cardiovascular collapse or even death, which is dependent on the rate and volume of carbon dioxide entrapment and the patient's condition. We reviewed extensive literature regarding carbon dioxide embolism in detail and set out to describe the complication from background to treatment. We hope that the present work will improve our understanding of carbon dioxide embolism during laparoscopic surgery.
Carbon Dioxide/*adverse effects
;
Embolism, Air/*diagnosis/epidemiology/prevention & control/surgery
;
Humans
;
Insufflation/adverse effects
;
Laparoscopy/*adverse effects
8.Postoperative subacute static progressive stretch does not increase the risk of distal lower limb venous thromboembolism.
Jun-Kun ZHU ; Feng-Feng WU ; Rui-Feng YANG ; Fen-Fen XU ; Ya-Li LIN ; Miao-Fang YE
Chinese Journal of Traumatology 2023;26(3):178-182
PURPOSE:
Static progressive stretch (SPS) can be applied to treat chronic joint stiffness. However, the impacts of subacute application of SPS to the distal lower limbs, where deep vein thrombosis (DVT) is common, on venous thromboembolism remain unclear. This study aims to explore the risk of venous thromboembolism events following subacute application of SPS.
METHODS:
A retrospective cohort study was conducted on patients diagnosed with DVT following a lower extremity orthopedic surgery before being transferred to the rehabilitation ward from May 2017 to May 2022. Patients with unilateral lower limb comminuted para-articular fractures, transferred to rehabilitation ward for further treatment within 3 weeks after operation, followed up more than 12 weeks since initial manual physiotherapy, and diagnosed DVT by ultrasound before rehabilitation course were included in the study. Patients with polytrauma, without evidence of previous peripheral vascular disease or incompetence, had medication for thrombosis treatment or prophylaxis before the operation, detected with paralysis due to nervous system impairment, infected after operation during the regime, or with acute progression of DVT were excluded. The included patients were randomized to the standard physiotherapy and the SPS integrated groups for observation. Associated DVT and pulmonary embolism data were collected during the physiotherapy course to compare the groups. SSPS 28.0 and GraphPad Prism 9 were used for data processing. A p < 0.05 was set significant difference.
RESULTS:
In total of 154 patients with DVT participating in this study, 75 of them were treated with additional SPS for postoperative rehabilitation. The participants in the SPS group showed improved range of motion (12.3° ± 6.7°). However, in the SPS group, there was no difference in thrombosis volume between the start and termination (p = 0.106, p = 0.787, respectively), although difference was seen intra-therapy (p < 0.001). Contingency analysis revealed the pulmonary embolism incidence (OR = 0.703) in the SPS group compared to the mean physiotherapy.
CONCLUSION
The SPS technique is a safe and reliable option to prevent potential joint stiffness without aggravating the risk of distal DVT for postoperative patients suffering from relevant trauma.
Humans
;
Venous Thromboembolism/prevention & control*
;
Venous Thrombosis/etiology*
;
Retrospective Studies
;
Pulmonary Embolism/complications*
;
Lower Extremity
;
Risk Factors
9.Application of damage control concept in severe limbs fractures combining with multiple trauma.
Er-gu-le BAYIN ; Hong-bing JIN ; Ming LI
China Journal of Orthopaedics and Traumatology 2015;28(9):811-814
OBJECTIVETo discuss the application and clinical effect of damage control concept in the treatment of severe limbs fractures combining with multiple trauma.
METHODSFrom July 2009 to July 2012, 30 patients with severe limbs fractures combining with multiple trauma were treated with the damage control concept, included 20 males and 10 females with an average age of (34.03 ± 12.81) years old ranging from 20 to 60 years old; the ISS averaged (35.00 ± 12.81) points (ranged from 26 to 54 points). And the control group also contained 30 patients with severe limbs fractures combining with multiple trauma treated by the traditional operation from June 2006 to June 2009, there were 23 males and 7 females with an average age of (34.23 ± 11.04) years old ranging from 18 to 65 years old. The ISS averaged (35.56 ± 11.04) points (ranged from 26 to 51 points). The age, gender, ISS, Gustilo classification, operation time, intraoperative blood loss, blood transfusion,postoperative complications and mortality rate were observed and compared.
RESULTSIn the damage control concept group,there were 28 cases surviving and 2 cases (6.7%) death; 6 cases of postoperative complication included 2 cases of adult respiratory distress syndrome, 1 case of multiple organ failure, 1 case of disseminated intravascular coagulation and 2 cases of wound infection. In the control group, there were 22 cases surviving and 8 cases death(26.7%); 13 cases of postoperative complication included 4 cases of adult respiratory distress syndrome,2 cases of multiple organ failure, 2 cases of disseminated intravascular coagulation and 3 cases of wound infection. There were no statistically significant differences between two groups in age, gender, ISS, Gustilo classfication and complication (P > 0.05), however there were statistically significant differences in mortality rate, operation time, blodd loss, blodd transfusion between two groups (P < 0.05).
CONCLUSIONDamage control concept is used to treat severe limbs fractures combining with multiple trauma which has the rapid and effective therapy, can improve survival rate and reduce complication.
Adolescent ; Adult ; Aged ; Embolism, Fat ; prevention & control ; Extremities ; injuries ; Female ; Humans ; Male ; Middle Aged ; Multiple Trauma ; surgery ; Postoperative Complications ; prevention & control