1.Coronary Artery Lumen Segmentation Using Location– Adaptive Threshold in Coronary Computed Tomographic Angiography: A Proof-of-Concept
Cheong-Il SHIN ; Sang Joon PARK ; Ji-Hyun KIM ; Yeonyee Elizabeth YOON ; Eun-Ah PARK ; Bon-Kwon KOO ; Whal LEE
Korean Journal of Radiology 2021;22(5):688-696
Objective:
To compare the lumen parameters measured by the location-adaptive threshold method (LATM), in which the inter- and intra-scan attenuation variabilities of coronary computed tomographic angiography (CCTA) were corrected, and the scan-adaptive threshold method (SATM), in which only the inter-scan variability was corrected, with the reference standard measurement by intravascular ultrasonography (IVUS).
Materials and Methods:
The Hounsfield unit (HU) values of whole voxels and the centerline in each of the cross-sections of the 22 target coronary artery segments were obtained from 15 patients between March 2009 and June 2010, in addition to the corresponding voxel size. Lumen volume was calculated mathematically as the voxel volume multiplied by the number of voxels with HU within a given range, defined as the lumen for each method, and compared with the IVUS-derived reference standard. Subgroup analysis of the lumen area was performed to investigate the effect of lumen size on the studied methods.Bland-Altman plots were used to evaluate the agreement between the measurements.
Results:
Lumen volumes measured by SATM was significantly smaller than that measured by IVUS (mean difference, 14.6 ㎣ ; 95% confidence interval [CI], 4.9–24.3 ㎣ ); the lumen volumes measured by LATM and IVUS were not significantly different (mean difference, -0.7 ㎣ ; 95% CI, -9.1–7.7 ㎣ ). The lumen area measured by SATM was significantly smaller than that measured by LATM in the smaller lumen area group (mean of difference, 1.07 ㎟ ; 95% CI, 0.89–1.25 ㎟ ) but not in the larger lumen area group (mean of difference, -0.07 ㎟ ; 95% CI, -0.22–0.08 ㎟ ). In the smaller lumen group, the mean difference was lower in the Bland-Altman plot of IVUS and LATM (0.46 ㎟ ; 95% CI, 0.27–0.65 ㎟ ) than in that of IVUS and SATM (1.53 ㎟ ; 95% CI, 1.27–1.79㎟ ).
Conclusion
SATM underestimated the lumen parameters for computed lumen segmentation in CCTA, and this may be overcome by using LATM.
2.Sex differences in weight perception and weight gain among Black college students in the USA
Jounghee LEE ; Jaesin SA ; Jean-Philippe CHAPUT ; James HEIMDAL ; Beatrice NELSON ; Beom-Young CHO ; Elizabeth KWON
Osong Public Health and Research Perspectives 2021;12(2):96-104
Objectives:
The aims of this study were to examine the prevalence of overweight/obesity and to explore sex differences in body weight perceptions and correlates of weight gain among Black students at 2 historically Black colleges and universities (HBCUs) in the USA.
Methods:
Participants completed a paper-based survey, and their height and weight weremeasured (67% completion rate).
Results:
The overweight and obesity rates were 33.8% and 26.9%, respectively. More females than males accurately assessed their weight (p < 0.05). Body weight underestimation was associated with male sex, excellent/very good perceived overall health, and not being informed by a doctor of having overweight or obesity (p <0.01). Higher odds of ≥5% weight gain were related to female sex, living on campus, and not being informed by a doctor of having overweight or obesity (p <0.05).
Conclusion
Given the high overweight and obesity rates among Black students, HBCUs in the USA should develop intervention strategies for the prevention and management of overweight and obesity. College health educators at HBCUs need to provide regular check-ups or health screenings that help male students perceive their weight accurately and prevent weight underestimation. It is important for HBCUs to monitor and address weight gain among Black students as early as possible.
3.Coronary Artery Lumen Segmentation Using Location– Adaptive Threshold in Coronary Computed Tomographic Angiography: A Proof-of-Concept
Cheong-Il SHIN ; Sang Joon PARK ; Ji-Hyun KIM ; Yeonyee Elizabeth YOON ; Eun-Ah PARK ; Bon-Kwon KOO ; Whal LEE
Korean Journal of Radiology 2021;22(5):688-696
Objective:
To compare the lumen parameters measured by the location-adaptive threshold method (LATM), in which the inter- and intra-scan attenuation variabilities of coronary computed tomographic angiography (CCTA) were corrected, and the scan-adaptive threshold method (SATM), in which only the inter-scan variability was corrected, with the reference standard measurement by intravascular ultrasonography (IVUS).
Materials and Methods:
The Hounsfield unit (HU) values of whole voxels and the centerline in each of the cross-sections of the 22 target coronary artery segments were obtained from 15 patients between March 2009 and June 2010, in addition to the corresponding voxel size. Lumen volume was calculated mathematically as the voxel volume multiplied by the number of voxels with HU within a given range, defined as the lumen for each method, and compared with the IVUS-derived reference standard. Subgroup analysis of the lumen area was performed to investigate the effect of lumen size on the studied methods.Bland-Altman plots were used to evaluate the agreement between the measurements.
Results:
Lumen volumes measured by SATM was significantly smaller than that measured by IVUS (mean difference, 14.6 ㎣ ; 95% confidence interval [CI], 4.9–24.3 ㎣ ); the lumen volumes measured by LATM and IVUS were not significantly different (mean difference, -0.7 ㎣ ; 95% CI, -9.1–7.7 ㎣ ). The lumen area measured by SATM was significantly smaller than that measured by LATM in the smaller lumen area group (mean of difference, 1.07 ㎟ ; 95% CI, 0.89–1.25 ㎟ ) but not in the larger lumen area group (mean of difference, -0.07 ㎟ ; 95% CI, -0.22–0.08 ㎟ ). In the smaller lumen group, the mean difference was lower in the Bland-Altman plot of IVUS and LATM (0.46 ㎟ ; 95% CI, 0.27–0.65 ㎟ ) than in that of IVUS and SATM (1.53 ㎟ ; 95% CI, 1.27–1.79㎟ ).
Conclusion
SATM underestimated the lumen parameters for computed lumen segmentation in CCTA, and this may be overcome by using LATM.
4.Sex differences in weight perception and weight gain among Black college students in the USA
Jounghee LEE ; Jaesin SA ; Jean-Philippe CHAPUT ; James HEIMDAL ; Beatrice NELSON ; Beom-Young CHO ; Elizabeth KWON
Osong Public Health and Research Perspectives 2021;12(2):96-104
Objectives:
The aims of this study were to examine the prevalence of overweight/obesity and to explore sex differences in body weight perceptions and correlates of weight gain among Black students at 2 historically Black colleges and universities (HBCUs) in the USA.
Methods:
Participants completed a paper-based survey, and their height and weight weremeasured (67% completion rate).
Results:
The overweight and obesity rates were 33.8% and 26.9%, respectively. More females than males accurately assessed their weight (p < 0.05). Body weight underestimation was associated with male sex, excellent/very good perceived overall health, and not being informed by a doctor of having overweight or obesity (p <0.01). Higher odds of ≥5% weight gain were related to female sex, living on campus, and not being informed by a doctor of having overweight or obesity (p <0.05).
Conclusion
Given the high overweight and obesity rates among Black students, HBCUs in the USA should develop intervention strategies for the prevention and management of overweight and obesity. College health educators at HBCUs need to provide regular check-ups or health screenings that help male students perceive their weight accurately and prevent weight underestimation. It is important for HBCUs to monitor and address weight gain among Black students as early as possible.