1.Verification of the PMCEPT Monte Carlo dose Calculation Code for Simulations in Medical Physics.
Korean Journal of Medical Physics 2008;19(1):21-34
The parallel Monte Carlo electron and photon transport (PMCEPT) code [Kum and Lee, J. Korean Phys. Soc. 47, 716 (2006)] for calculating electron and photon beam doses has been developed based on the three dimensional geometry defined by computed tomography (CT) images and implemented on the Beowulf PC cluster. Understanding the limitations of Monte Carlo codes is useful in order to avoid systematic errors in simulations and to suggest further improvement of the codes. We evaluated the PMCEPT code by comparing its normalized depth doses for electron and photon beams with those of MCNP5, EGS4, DPM, and GEANT4 codes, and with measurements. The PMCEPT results agreed well with others in homogeneous and heterogeneous media within an error of 1~3% of the dose maximum. The computing time benchmark has also been performed for two cases, showing that the PMCEPT code was approximately twenty times faster than the MCNP5 for 20-MeV electron beams irradiated on the water phantom. For the 18-MV photon beams irradiated on the water phantom, the PMCEPT was three times faster than the GEANT4. Thus, the results suggest that the PMCEPT code is indeed appropriate for both fast and accurate simulations.
Electrons
;
Water
2.Study on the Evaluation of TRS-398 Quality Factors with Central Electrode Corrections for Small Cylindrical Chambers.
Yeong Rok KANG ; Chang Yeol LEE ; Jin Ho KIM ; Young Min MOON ; Dong Won KWAK ; Sang Koo KANG ; Jeung Kee KIM ; Kwangmo YANG ; Dong Hyeok JEONG
Korean Journal of Medical Physics 2011;22(3):148-154
The quality factors (kQ,Q0) were evaluated by appling the results recently studied for the effect of central electrode in TRS-398 protocol. The PTW-31010 and IBA-CC13 chambers were used in this study. The quality factors were calculated as a function of beam quality for high energy electron and photon beams and compared with data currently used in TRS-398 protocol. In the PTW-31010 chamber using aluminium electrode, appling the new central electrode collections, the quality factors were 0.4% and 0.9% higher than current TRS-398 data for high energy photon and electron beams respectively. In the IBA-CC13 chamber using C-552 electrode, there are no variations in quality factors compared to TRS-398 data currently used.
Electrodes
;
Electrons
3.Study on Absorbed Dose Determination of Electron Beam Quality for Cross-calibration with Plane-parallel Ionization Chamber.
Jeong Eun RAH ; Dong Oh SHIN ; So Hyun PARK ; Hojin JEONG ; Ui Jung HWANG ; Sung Hwan AHN ; Young Kyung LIM ; Dong Wook KIM ; Myonggeun YOON ; Dong Ho SHIN ; Se Byeong LEE ; Tae Suk SUH ; Sung Yong PARK
Korean Journal of Medical Physics 2009;20(2):97-105
Absorbed dose to water based protocols recommended that plane-parallel chambers be calibrated against calibrated cylindrical chambers in a high energy electron beam with R50>7 g/cm2 (E> or =16 MeV). However, such high-energy electron beams are not available at all radiotherapy centers. In this study, we are compared the absorbed dose to water determined according to cross-calibration method in a high energy electron beam of 16 MeV and in electron beam energies of 12 MeV below the cross-calibration quality remark. Absorbed dose were performed for PTW 30013, Wellhofer FC65G Farmer type cylindrical chamber and for PTW 34001, Wellhofer PPC40 Roos type plane-parallel chamber. The cylindrical and the plane-parallel chamber to be calibrated are compared by alternately positioning each at reference depth, zref=0.6R50-0.1 in water phantom. The DW of plane-parallel chamber are derived using across-calibration method at high-energy electron beams of 16, 20 MeV. Then a good agreement is obtained the DW of plane-parallel chamber in 12 MeV. The agreement between 20 MeV and 12 MeV are within 0.2% for IAEA TRS-398.
Electrons
;
Water
4.Estimation of Inhomogeneity Correction Factor in Small Field Dosimetry.
Hun Joo SHIN ; Young Nam KANG ; Jisun JANG ; Jae Hyuk SEO ; Ji Young JUNG ; Byung Ock CHOI ; Ihl Bohng CHOI ; Dong Joon LEE ; Soo Il KWON
Korean Journal of Medical Physics 2009;20(4):260-268
In this study, we estimated inhomogeneity correction factor in small field. And, we evaluated accuracy of treatment planning and measurement data which applied inhomogeneity correction factor or not. We developed the Inhomogeneity Correction Phantom (ICP) for insertion of inhomogeneity materials. The inhomogeneity materials were 12 types in each different electron density. This phantom is able to adapt the EBT film and 0.125 cc ion chamber for measurement of dose distribution and point dose. We evaluated comparison of planning and measurement data using ICP. When we applied to inhomogeneity correction factor or not, the average difference was 1.63% and 10.05% in each plan and film measurement data. And, the average difference of dose distribution was 10.09% in each measurement film. And the average difference of point dose was 0.43% and 2.09% in each plan and measurement data. In conclusion, if we did not apply the inhomogeneity correction factor in small field, it shows more great difference in measurement data. The planning system using this study shows good result for correction of inhomogeneity materials. In radiosurgery using small field, we should be correct the inhomogeneity correction factor, more exactly.
Electrons
;
Radiosurgery
5.A Novel Aromatic Fluorine-18 Labeling Method Using Iodonium Salts Precursor.
Byung Seok MOON ; Byung Chul LEE ; Sang Eun KIM
Nuclear Medicine and Molecular Imaging 2009;43(1):1-9
As many new drug substances contained various aromatic rings and fluorine attached to an electron rich aromatic ring or on the meta-position, a strategy towards improvement in aromatic fluorination of these compounds is highly desirable. The introduction of fluorine-18 onto aromatic rings showed in the limited condition containing electron withdrawing group (EWG) on the para- or ortho-position to get reasonable radiochemical yield so far. No-carrier added (NCA) [18F]fluoroarene syntheses by iodonium salts recently reported that has the potential to greatly increase the yield in systems or positions that normally not reactive enough to give sufficient yields in simple model reaction. This review describes the methodological approach towards effective aromatic fluorination by diaryliodonium salts and future prospects in an application of novel PET radiotracer.
Electrons
;
Fluorine
;
Halogenation
;
Salts
6.Chamber-to-chamber Variations in the Same Type of a Cylindrical Chamber for the Measurements of Absorbed Doses.
Seong Hoon KIM ; Hyundo HUH ; Sang Hyun CHOI ; Hyeog Ju KIM ; Chunil LIM ; Dong Oh SHIN ; Jinho CHOI
Korean Journal of Medical Physics 2010;21(1):120-125
For the measurements of an absorbed dose using the standard dosimetry based on an absorbed dose to water the variety of factors, whether big, small, or tiny, may influence the accuracy of dosimetry. The beam quality correction factor kappa(Q, Q(0))of an ionization chamber might also be one of them. The cylindrical type of ionization chamber, the PTW30013 chamber, was chosen for this work and 9 chambers of the same type were collected from several institutes where the chamber types are used for the reference dosimetry. They were calibrated from the domestic Secondary Standard Dosimetry Laboratory with the same electrometer and cable. These calibrated chambers were used to measure absorbed doses to water in the reference condition for the photon beam of 6 MV and 10 MV and the electron beam of 12 MeV from Siemens ONCOR. The biggest difference among chambers amounts to 2.4% for the 6 MV photon beam, 0.8% for the 10 MV photon beam, and 2.4% for the 12 MeV electron beam. The big deviation in the photon of 6 MV demonstrates that if there had been no problems with the process of measurements application of the same kappa(Q, Q(0)) to the chambers used in this study might have influenced the deviation in the photon 6 MV and that how important an external audit is.
Academies and Institutes
;
Electrons
;
Water
7.Applicationof Positron Emission Tomography in Gastrointestimal Carcinomas.
The Korean Journal of Hepatology 1996;2(2):129-133
No abstract available.
Electrons*
;
Positron-Emission Tomography*
8.External Auditing on Absorbed Dose Using a Solid Water Phantom for Domestic Radiotherapy Facilities.
Chang Heon CHOI ; Jung In KIM ; Jong Min PARK ; Yang Kyun PARK ; Kun Woo CHO ; Woon Kap CHO ; Chun Il LIM ; Sung Joon YE
The Journal of the Korean Society for Therapeutic Radiology and Oncology 2010;28(1):50-56
PURPOSE: We report the results of an external audit on the absorbed dose of radiotherapy beams independently performed by third parties. For this effort, we developed a method to measure the absorbed dose to water in an easy and convenient setup of solid water phantom. MATERIALS AND METHODS: In 2008, 12 radiotherapy centers voluntarily participated in the external auditing program and 47 beams of X-ray and electron were independently calibrated by the third party's American Association of Physicists in Medicine (AAPM) task group (TG)-51 protocol. Even though the AAPM TG-51 protocol recommended the use of water, water as a phantom has a few disadvantages, especially in a busy clinic. Instead, we used solid water phantom due to its reproducibility and convenience in terms of setup and transport. Dose conversion factors between solid water and water were determined for photon and electron beams of various energies by using a scaling method and experimental measurements. RESULTS: Most of the beams (74%) were within +/-2% of the deviation from the third party's protocol. However, two of 20 X-ray beams and three of 27 electron beams were out of the tolerance (+/-3%), including two beams with a >10% deviation. X-ray beams of higher than 6 MV had no conversion factors, while a 6 MV absorbed dose to a solid water phantom was 0.4% less than the dose to water. The electron dose conversion factors between the solid water phantom and water were determined: The higher the electron energy, the less is the conversion factor. The total uncertainty of the TG-51 protocol measurement using a solid water phantom was determined to be +/-1.5%. CONCLUSION: The developed method was successfully applied for the external auditing program, which could be evolved into a credential program of multi-institutional clinical trials. This dosimetry saved time for measuring doses as well as decreased the uncertainty of measurement possibly resulting from the reference setup in water.
Electrons
;
Phenylpropionates
;
Uncertainty
;
Water
9.Development of Electronic Medical Chart for Radiation Oncology.
Sam Ju CHO ; Su Jung SHIM ; Suk LEE ; Sang Hoon LEE ; Kwang Hwan CHO ; Hyun Do HUH ; Sangwook LIM ; Jin Ho CHOI ; Jun Young CHOI ; Hyong Geun YUN ; Dong Oh SHIN
Korean Journal of Medical Physics 2009;20(3):167-173
As the radiotherapy technique development, the needs for using of medical electronic chart in the department of radiation oncology is growing. However, the complexity of affairs of radiation oncology make it difficult to develop a electronic medical chart. In this study, we introduce the electronic medical chart developed by domestic hospital. The function and example of electronic medical chart designed as radiation treatment progress was showed and the future study was presented.
Electronics
;
Electrons
;
Radiation Oncology
10.Development of Electronic Medical Chart for Radiation Oncology.
Sam Ju CHO ; Su Jung SHIM ; Suk LEE ; Sang Hoon LEE ; Kwang Hwan CHO ; Hyun Do HUH ; Sangwook LIM ; Jin Ho CHOI ; Jun Young CHOI ; Hyong Geun YUN ; Dong Oh SHIN
Korean Journal of Medical Physics 2009;20(3):167-173
As the radiotherapy technique development, the needs for using of medical electronic chart in the department of radiation oncology is growing. However, the complexity of affairs of radiation oncology make it difficult to develop a electronic medical chart. In this study, we introduce the electronic medical chart developed by domestic hospital. The function and example of electronic medical chart designed as radiation treatment progress was showed and the future study was presented.
Electronics
;
Electrons
;
Radiation Oncology