1.Study on Absorbed Dose Determination of Electron Beam Quality for Cross-calibration with Plane-parallel Ionization Chamber.
Jeong Eun RAH ; Dong Oh SHIN ; So Hyun PARK ; Hojin JEONG ; Ui Jung HWANG ; Sung Hwan AHN ; Young Kyung LIM ; Dong Wook KIM ; Myonggeun YOON ; Dong Ho SHIN ; Se Byeong LEE ; Tae Suk SUH ; Sung Yong PARK
Korean Journal of Medical Physics 2009;20(2):97-105
Absorbed dose to water based protocols recommended that plane-parallel chambers be calibrated against calibrated cylindrical chambers in a high energy electron beam with R50>7 g/cm2 (E> or =16 MeV). However, such high-energy electron beams are not available at all radiotherapy centers. In this study, we are compared the absorbed dose to water determined according to cross-calibration method in a high energy electron beam of 16 MeV and in electron beam energies of 12 MeV below the cross-calibration quality remark. Absorbed dose were performed for PTW 30013, Wellhofer FC65G Farmer type cylindrical chamber and for PTW 34001, Wellhofer PPC40 Roos type plane-parallel chamber. The cylindrical and the plane-parallel chamber to be calibrated are compared by alternately positioning each at reference depth, zref=0.6R50-0.1 in water phantom. The DW of plane-parallel chamber are derived using across-calibration method at high-energy electron beams of 16, 20 MeV. Then a good agreement is obtained the DW of plane-parallel chamber in 12 MeV. The agreement between 20 MeV and 12 MeV are within 0.2% for IAEA TRS-398.
Electrons
;
Water
2.Estimation of Inhomogeneity Correction Factor in Small Field Dosimetry.
Hun Joo SHIN ; Young Nam KANG ; Jisun JANG ; Jae Hyuk SEO ; Ji Young JUNG ; Byung Ock CHOI ; Ihl Bohng CHOI ; Dong Joon LEE ; Soo Il KWON
Korean Journal of Medical Physics 2009;20(4):260-268
In this study, we estimated inhomogeneity correction factor in small field. And, we evaluated accuracy of treatment planning and measurement data which applied inhomogeneity correction factor or not. We developed the Inhomogeneity Correction Phantom (ICP) for insertion of inhomogeneity materials. The inhomogeneity materials were 12 types in each different electron density. This phantom is able to adapt the EBT film and 0.125 cc ion chamber for measurement of dose distribution and point dose. We evaluated comparison of planning and measurement data using ICP. When we applied to inhomogeneity correction factor or not, the average difference was 1.63% and 10.05% in each plan and film measurement data. And, the average difference of dose distribution was 10.09% in each measurement film. And the average difference of point dose was 0.43% and 2.09% in each plan and measurement data. In conclusion, if we did not apply the inhomogeneity correction factor in small field, it shows more great difference in measurement data. The planning system using this study shows good result for correction of inhomogeneity materials. In radiosurgery using small field, we should be correct the inhomogeneity correction factor, more exactly.
Electrons
;
Radiosurgery
3.Study on the Evaluation of TRS-398 Quality Factors with Central Electrode Corrections for Small Cylindrical Chambers.
Yeong Rok KANG ; Chang Yeol LEE ; Jin Ho KIM ; Young Min MOON ; Dong Won KWAK ; Sang Koo KANG ; Jeung Kee KIM ; Kwangmo YANG ; Dong Hyeok JEONG
Korean Journal of Medical Physics 2011;22(3):148-154
The quality factors (kQ,Q0) were evaluated by appling the results recently studied for the effect of central electrode in TRS-398 protocol. The PTW-31010 and IBA-CC13 chambers were used in this study. The quality factors were calculated as a function of beam quality for high energy electron and photon beams and compared with data currently used in TRS-398 protocol. In the PTW-31010 chamber using aluminium electrode, appling the new central electrode collections, the quality factors were 0.4% and 0.9% higher than current TRS-398 data for high energy photon and electron beams respectively. In the IBA-CC13 chamber using C-552 electrode, there are no variations in quality factors compared to TRS-398 data currently used.
Electrodes
;
Electrons
4.Verification of the PMCEPT Monte Carlo dose Calculation Code for Simulations in Medical Physics.
Korean Journal of Medical Physics 2008;19(1):21-34
The parallel Monte Carlo electron and photon transport (PMCEPT) code [Kum and Lee, J. Korean Phys. Soc. 47, 716 (2006)] for calculating electron and photon beam doses has been developed based on the three dimensional geometry defined by computed tomography (CT) images and implemented on the Beowulf PC cluster. Understanding the limitations of Monte Carlo codes is useful in order to avoid systematic errors in simulations and to suggest further improvement of the codes. We evaluated the PMCEPT code by comparing its normalized depth doses for electron and photon beams with those of MCNP5, EGS4, DPM, and GEANT4 codes, and with measurements. The PMCEPT results agreed well with others in homogeneous and heterogeneous media within an error of 1~3% of the dose maximum. The computing time benchmark has also been performed for two cases, showing that the PMCEPT code was approximately twenty times faster than the MCNP5 for 20-MeV electron beams irradiated on the water phantom. For the 18-MV photon beams irradiated on the water phantom, the PMCEPT was three times faster than the GEANT4. Thus, the results suggest that the PMCEPT code is indeed appropriate for both fast and accurate simulations.
Electrons
;
Water
5.Comparison of the Efficacy of 2D Dosimetry Systems in the Pre-treatment Verification of IMRT.
Chae Seon HONG ; Jongsoo LIM ; Sang Gyu JU ; Eunhyuk SHIN ; Youngyih HAN ; Yong Chan AHN
The Journal of the Korean Society for Therapeutic Radiology and Oncology 2009;27(2):91-102
PURPOSE: To compare the accuracy and efficacy of EDR2 film, a 2D ionization chamber array (MatriXX) and an amorphous silicon electronic portal imaging device (EPID) in the pre-treatment QA of IMRT. MATERIALS AND METHODS: Fluence patterns, shaped as a wedge with 10 steps (segments) by a multi-leaf collimator (MLC), of reference and test IMRT fields were measured using EDR2 film, the MatriXX, and EPID. Test fields were designed to simulate leaf positioning errors. The absolute dose at a point in each step of the reference fields was measured in a water phantom with an ionization chamber and was compared to the dose obtained with the use of EDR2 film, the MatriXX and EPID. For qualitative analysis, all measured fluence patterns of both reference and test fields were compared with calculated dose maps from a radiation treatment planning system (Pinnacle, Philips, USA) using profiles and gamma evaluation with 3%/3 mm and 2%/2 mm criteria. By measurement of the time to perform QA, we compared the workload of EDR2 film, the MatriXX and EPID. RESULTS: The percent absolute dose difference between the measured and ionization chamber dose was within 1% for the EPID, 2% for the MatriXX and 3% for EDR2 film. The percentage of pixels with gamma%>1 for the 3%/3 mm and 2%/2 mm criteria was within 2% for use of both EDR2 film and the EPID. However, differences for the use of the MatriXX were seen with a maximum difference as great as 5.94% with the 2%/2 mm criteria. For the test fields, EDR2 film and EPID could detect leaf-positioning errors on the order of -3 mm and -2 mm, respectively. However it was difficult to differentiate leaf-positioning errors with the MatriXX due to its poor resolution. The approximate time to perform QA was 110 minutes for the use of EDR2 film, 80 minutes for the use of the MatriXX and approximately 55 minutes for the use of the EPID. CONCLUSION: This study has evaluated the accuracy and efficacy of EDR2 film, the MatriXX and EPID in the pre-treatment verification of IMRT. EDR2 film and the EPID showed better performance for accuracy, while the use of the MatriXX significantly reduced measurement and analysis times. We propose practical and useful methods to establish an effective QA system in a clinical environment.
Electronics
;
Electrons
;
Silicon
;
Water
6.The Role of Positron Emission Tomography/Computed Tomography in the Initial Staging of Colon Cancer.
Annals of Coloproctology 2014;30(1):3-4
No abstract available.
Colon*
;
Colonic Neoplasms*
;
Electrons*
7.Effect of internal stress on cyclic fatigue failure in .06 taper ProFile.
Hye Rim JUNG ; Jin Woo KIM ; Kyung Mo CHO ; Se Hee PARK
Restorative Dentistry & Endodontics 2012;37(2):79-83
OBJECTIVES: The purpose of this study was to evaluate the relation between intentionally induced internal stress and cyclic fatigue failure of .06 taper ProFile. MATERIALS AND METHODS: Length 25 mm, .06 taper ProFile (Dentsply Maillefer), and size 20, 25, 30, 35 and 40 were used in this study. To give the internal stress, the rotary NiTi files were put into the .02 taper, Endo-Training-Bloc (Dentsply Maillefer) until auto-stop by torque controlled motor. Rotary NiTi files were grouped by the number of induced internal stress and randomly distributed among one control group and three experimental groups (n = 10, Stress 0 [control], Stress 1, Stress 2 and Stress 3). For cyclic fatigue measurement, time for separation of the rotary NiTi files was recorded. The fractured surfaces were observed by field emission scanning electron microscope (FE-SEM, SU-70, Hitachi). The time for separation was statistically analyzed using two-way ANOVA and post-hoc Scheffe test at 95% level. RESULTS: In .06 taper ProFile size 20, 25, 30, 35 and 40, there were statistically significant difference on time for separation between control group and the other groups (p < 0.05). CONCLUSION: In the limitation of this study, cyclic fatigue failure of .06 taper ProFile is influenced by internal stress accumulated in the files.
Electrons
;
Fatigue
;
Intention
;
Torque
8.Development of Electronic Medical Chart for Radiation Oncology.
Sam Ju CHO ; Su Jung SHIM ; Suk LEE ; Sang Hoon LEE ; Kwang Hwan CHO ; Hyun Do HUH ; Sangwook LIM ; Jin Ho CHOI ; Jun Young CHOI ; Hyong Geun YUN ; Dong Oh SHIN
Korean Journal of Medical Physics 2009;20(3):167-173
As the radiotherapy technique development, the needs for using of medical electronic chart in the department of radiation oncology is growing. However, the complexity of affairs of radiation oncology make it difficult to develop a electronic medical chart. In this study, we introduce the electronic medical chart developed by domestic hospital. The function and example of electronic medical chart designed as radiation treatment progress was showed and the future study was presented.
Electronics
;
Electrons
;
Radiation Oncology
9.Development of Electronic Medical Chart for Radiation Oncology.
Sam Ju CHO ; Su Jung SHIM ; Suk LEE ; Sang Hoon LEE ; Kwang Hwan CHO ; Hyun Do HUH ; Sangwook LIM ; Jin Ho CHOI ; Jun Young CHOI ; Hyong Geun YUN ; Dong Oh SHIN
Korean Journal of Medical Physics 2009;20(3):167-173
As the radiotherapy technique development, the needs for using of medical electronic chart in the department of radiation oncology is growing. However, the complexity of affairs of radiation oncology make it difficult to develop a electronic medical chart. In this study, we introduce the electronic medical chart developed by domestic hospital. The function and example of electronic medical chart designed as radiation treatment progress was showed and the future study was presented.
Electronics
;
Electrons
;
Radiation Oncology
10.A Novel Aromatic Fluorine-18 Labeling Method Using Iodonium Salts Precursor.
Byung Seok MOON ; Byung Chul LEE ; Sang Eun KIM
Nuclear Medicine and Molecular Imaging 2009;43(1):1-9
As many new drug substances contained various aromatic rings and fluorine attached to an electron rich aromatic ring or on the meta-position, a strategy towards improvement in aromatic fluorination of these compounds is highly desirable. The introduction of fluorine-18 onto aromatic rings showed in the limited condition containing electron withdrawing group (EWG) on the para- or ortho-position to get reasonable radiochemical yield so far. No-carrier added (NCA) [18F]fluoroarene syntheses by iodonium salts recently reported that has the potential to greatly increase the yield in systems or positions that normally not reactive enough to give sufficient yields in simple model reaction. This review describes the methodological approach towards effective aromatic fluorination by diaryliodonium salts and future prospects in an application of novel PET radiotracer.
Electrons
;
Fluorine
;
Halogenation
;
Salts