1.Rapid determination of 8 urinary carbamate pesticides by liquid chromatography-tandem mass spectrometry.
Hualiang LIU ; Yuan WANG ; E-mail: LHL-1@163.COM. ; Baoli ZHU
Chinese Journal of Industrial Hygiene and Occupational Diseases 2015;33(11):857-859
OBJECTIVETo establish a method for simultaneously determining the urinary concentrations of 8 carbamate pesticides.
METHODSAfter being purified by acetonitrile precipitation, urine samples were transferred to a liquid chromatography-tandem mass spectrometry system, and the concentrations of 8 carbamate pesticides were determined by external standard method. A C18 column was used for ultra-high-performance liquid chromatography; methanol/ammonium acetate solution was used as the mobile phase for gradient elution; the mass spectrometer was operated in a multi-reaction monitoring mode.
RESULTSThe calibration curves were linear when the urinary concentrations of these carbamate pesticides were 20~800 µg/L, and the recovery rates were 61.0%~121% at spiked levels of 20, 200 and 800 µg/L, with a relative standard deviation of 1.7%~5.5%.
CONCLUSIONThis determination method meets the Guide for establishing occupational health standards-part 5: Determination methods of chemicals in biological materials, and can be used for simultaneous determination of 8 carbamate pesticides in the urine of poisoning patients.
Calibration ; Carbamates ; urine ; Chromatography, High Pressure Liquid ; Humans ; Pesticides ; urine ; Tandem Mass Spectrometry