1.Relationship between chicken cellular immunity and endotoxin levels in dust from chicken housing environments.
Katharine ROQUE ; Kyung Min SHIN ; Ji Hoon JO ; Hyoung Ah KIM ; Yong HEO
Journal of Veterinary Science 2015;16(2):173-177
Hazardous biochemical agents in animal husbandry indoor environments are known to promote the occurrence of various illnesses among workers and animals. The relationship between endotoxin levels in dust collected from chicken farms and various immunological markers was investigated. Peripheral blood was obtained from 20 broiler chickens and 20 laying hens from four different chicken farms in Korea. Concentrations of total or respirable dust in the inside the chicken farm buildings were measured using a polyvinyl chloride membrane filter and mini volume sampler. Endotoxin levels in the dust were determined by the Limulus Amebocyte Lysate Kinetic method. Interferon-gamma production by peripheral blood mononuclear cells stimulated with concanavalin A was significantly lower in broilers or layers from the farms with higher endotoxin concentrations than the chickens from the farms with lower endotoxin levels. An opposite pattern was observed for plasma cortisol concentrations with higher cortisol levels found in chickens from the farms with higher endotoxin levels. When peripheral lymphocytes were examined, the percentage of CD3-Ia+ B cells was lower in layers from farms with higher endotoxin levels than those from locations with lower endotoxin levels. Overall, these results suggest a probable negative association between dust endotoxin levels and cell-mediated immunity in chickens.
Animal Husbandry
;
Animals
;
Biomarkers/blood
;
Chickens/*immunology
;
Dust/*analysis
;
Endotoxins/*analysis
;
*Housing, Animal
;
*Immunity, Cellular
2.House Dust Mite Allergens in Domestic Homes in Cheonan, Korea.
Hae Seon NAM ; Robert SIEBERS ; Sun Hwa LEE ; Joon Soo PARK ; Yong Bae KIM ; Young Jin CHOI ; Sang Han LEE ; Julian CRANE
The Korean Journal of Parasitology 2008;46(3):187-189
House dust mites produce inhalant allergens of importance to allergic patients. We measured the major group 1 allergens, Der p 1 and Der f 1, from the house dust mites Dermatophagoides pteronyssinus and Dermatophagoides farina, respectively in 100 randomly selected domestic homes from Cheonan, Korea. Dust samples were collected by vacuuming from the living room floor and 1 mattress in each home. Der p 1 and Der f 1 were measured by double monoclonal ELISA. Der p 1 levels were very low, with geometric mean levels for floors and mattresses being 0.11 microgram/g (range: 0.01-4.05) and 0.14 microgram/g (range: 0.01-30.0), respectively. Corresponding levels of Der f 1 were higher, 7.46 microgram/g (range: 0.01-262.9) and 10.2 microgram/g (range: 0.01-230.9) for floors and mattresses, respectively. D. farinae appears to be the dominant house dust mite in Cheonan.
Animals
;
Antigens, Dermatophagoides/immunology/*isolation & purification
;
Bedding and Linens
;
Dust/analysis
;
Floors and Floorcoverings
;
Housing
;
Humans
;
Korea
;
Pyroglyphidae/*immunology
3.C3-containing IgE immune complexes in asthmatic patients.
Journal of Korean Medical Science 1996;11(3):217-221
Higher levels of IgE-containing immune complexes (IC) have been reported in sera from patients with allergic diseases than in sera from controls. To evaluate the possibility of an IC-mediated mechanism in the pathogenesis of bronchial asthma, we measured circulating C3-containing IgE IC (C3-IgE IC) using anti-C3 ELISA from 20 house dust mite (HDM)-sensitive asthmatics, 20 non-atopic asthmatics, and 14 non-atopic controls. C3-IgE IC levels were significantly higher in HDM-sensitive asthmatics (mean +/- S.D.: 12.2 +/- 7.8 AU/ml) than in non-atopic asthmatics (6.5 +/- 7.5 AU/ml) or controls (5.8 +/- 4.4 AU/ml). C3-IgE IC levels were significantly correlated with HDM-specific IgE levels (r = 0.50, p<0.05), but not with total IgE levels (r = 0.36, p< 0.05) in HDM-sensitive atopic asthmatics. C3-IgE IC levels in sera did not significantly change during HDM-bronchoprovocation test in six HDM-sensitive asthmatics who showed positive reaction. Part of C3-IgE IC could be precipitated by protein G coupled beads. In conclusion, C3-IgE IC levels were elevated in sera from HDM-sensitive asthmatics; moreover IgG antibodies might be a component of C3-IgE IC. Our results suggest that an IgE IC-mediated mechanism could be involved in the pathogenesis of atopic asthma.
Adult
;
Animal
;
Antigen-Antibody Complex/*blood
;
Asthma/*immunology
;
Complement 3/*analysis
;
Dust
;
Human
;
Immunoglobulin E/*blood
;
Mites/immunology
4.Identification of major allergens from the house dust mites, Dermatophagoides farinae and Dermatophagoides pteronyssinus, by electroblotting.
Chein Soo HONG ; Mi Kyung LEE ; Sang Hwan OH
Yonsei Medical Journal 1991;32(1):24-32
The allergens were separated from the extracts of house dust mites by SDS-polyacrylamide gel electrophoresis (SDS-PAGE) and identified by autoradiography. Over 30 protein bands of the whole body extract of Dermatophagoides farinae were apparent on 10-20% gradient SDS-PAGE, and 13 bands with MW between 93KD and 12KD bound with specific IgE antibodies in patients' sera sensitive to house dust mites. The major allergenic component of the whole body extract of D. farinae was the protein of MW 14-15KD, which was detected in 95.7% of 47 patients' sera sensitive to house dust mites. The extract of Dermatophagoides pteronyssinus supplied by Bencard Company, England was thought to contain feces enriched material as noted in a few broad protein bands on SDS-PAGE. Seven allergenic components were shown by autoradiography. The protein band of MW 14-15KD was one of the most frequently revealed allergens on autoradiography, which has appeared in 32.5% of 40 patients' sera sensitive to house dust mites. The electrobotting technique used in the present study was fast, convenient and highly useful for both the identification of allergen components and the screening of specific IgE antibody. The individual variations of IgE immune responses to the allergenic components of the two house dust mites were discussed.
Allergens/*analysis
;
Animals
;
Autoradiography
;
Dust
;
Electrophoresis, Polyacrylamide Gel
;
Human
;
Immunoglobulin E/metabolism
;
Mites/*immunology
;
Support, Non-U.S. Gov't
5.Indoor mite allergen levels, specific IgE prevalence and IgE cross-inhibition pattern among asthmatic children in Haikou, southern China.
Yi-Wu ZHENG ; Shi CHEN ; Xu-Xin LAI ; Birgitte GJESING ; Nan-Shan ZHONG ; Michael D SPANGFORT
Chinese Medical Journal 2012;125(17):3059-3063
BACKGROUNDHaikou locates in tropical island with unique mite propagation. The aim of this stuy is to determine mite allergens levels in Haikou, and to investigate the prevalence of mite specific IgE-sensitization and IgE cross-reactivity between house dust mites.
METHODSAllergen and antigen concentrations against six mite species were tested by enzyme-linked immunosorbent assay (ELISA). Specific IgE concentrations and cross-inhibitions were measured with ADVIA Centaur(®).
RESULTSAllergen or antigen Dermatophagoides pteronyssinus (Der p 1), Blomia tropicalis (Blo t) and Tyrophagus putrescentia (Tyr p) were detected in dust samples. Dermatophagoides farinae (Der f 1), Lepidoglyphus destructor (Lep d 2), and Acarus siro (Aca s) were found in very few samples. Specific IgE tests showed high prevalence of sensitizations against all tested mites with high IgE levels to Der p, Der f, and Blo t. Storage mites, Blo t, Tyr p, Lep d, and Aca s, could inhibit Der p from 0 to 50%. Storage mites could inhibit Der f between 30% and 100%. Der p IgE could be inhibited by Der f with up to 90%, and vice versa. Der p could inhibit Blo t from 40% to 80%. Blo t was able to fully inhibit IgE binding to Lep d, Tyr p, and Aca s compared to partial inhibition by Der p.
CONCLUSIONSDer p is the dominating mite and has the highest specific IgE prevalence among asthmatic children. Blo t represents an important source of storage mite sensitization and some patients may be independently sensitized to both Der p and Blo t. High prevalence of sensitization to Der f may be due to IgE-mediated cross-reactivity with Der p and Blo t.
Adolescent ; Air Pollution, Indoor ; Allergens ; analysis ; Animals ; Antigens, Dermatophagoides ; analysis ; Arthropod Proteins ; analysis ; Asthma ; immunology ; Child ; Child, Preschool ; China ; Cross Reactions ; Cysteine Endopeptidases ; analysis ; Dust ; Humans ; Immunoglobulin E ; blood ; immunology ; Mites ; immunology
6.House dust mite allergen (Derp1 and Blot5) levels in asthmatics' home in Hongkong.
Bao-qing SUN ; Adrian WU ; Albert CHAN ; Stanley CHIK ; Dorothy WONG ; Nan-shan ZHONG
Chinese Medical Sciences Journal 2004;19(3):185-188
OBJECTIVETo measure Derp1 and Blot5 allergen levels in asthmatics' homes in Hongkong.
METHODSSeventy houses were enrolled for a mite indoor environment study. Dust samples were obtained from two sites of each patients' house: bed and floor. Derp1 and Blot5 levels were quantified by a two-site monoclonal antibody-based ELISA technique.
RESULTSThe levels of Derp1 allergens found in bed (geometric mean (GM) 3.43 microg/g of dust; 95%CI, 1.89-4.96 microg/g) and on the floor (GM 1.12 microg/g of dust; 95%CI, 0.71-1.53 microg/g) indicated significant differences (P=0.005). However, the levels of Blot5 allergens found in bed (GM 19.00 microg/g of dust; 95%CI, 0.89-38.90 microg/g) and on the floor (GM 6.14 microg/g of dust; 95%CI, 0.40-11.90 microg/g) showed no statistically significant difference. In addition, in regards to the exposure index for Derp1 and Blot5 allergens found in bed and on the floor, 17.6% in bed and 8.6% on the floor had levels of Blot5 > or = 10 microg/g of dust, higher than those obtained for Derp1 (7.2% and 0% in bed and on the floor respectively, P<0.05); higher percentages in bed and on the floor (25.0% and 35.7%) were observed for levels of Blot5 = 0 microg/g of dust as compared with Derp1 in bed and on the floor (4.3% and 14.5% respectively, P<0.05).
CONCLUSIONSDerp1 and Blot5 are the major allergens found in this regional study, Blot5 is a more potent allergen in Hongkong, probably reflecting the high level of exposure to Blomia tropicalis (Bt). Bt and Dermatophagoides pteronyssinus (Dp) allergens should be included for precise diagnosis and effective immuno-therapeutic treatment of mite allergy in Hongkong.
Allergens ; analysis ; Animals ; Antigens, Dermatophagoides ; analysis ; Arthropod Proteins ; Asthma ; immunology ; Bedding and Linens ; Cysteine Endopeptidases ; Dermatophagoides pteronyssinus ; immunology ; Dust ; analysis ; Environmental Exposure ; Floors and Floorcoverings ; Hong Kong ; Housing ; Humans ; Humidity ; Mites ; immunology
7.Effect of Bedding Control on Amount of House Dust Mite Allergens, Asthma Symptoms, and Peak Expiratory Flow Rate.
Yonsei Medical Journal 2003;44(2):313-322
This quasi-experimental study was designed to investigate the effect of bedding control on the amount of house dust mite (HDM) allergens, asthma symptoms, and peak expiratory flow rate (PEFR) in asthmatics sensitive to HDMs. The subjects in the study were drawn from patients receiving treatment at the allergy clinics of three university-affiliated hospitals in Seoul. Forty-two patients without prior practice of the bedding control used in this study were selected. They commonly showed bronchial asthma caused by HDMs, and exhibited strong positive points (more than 3 points) in skin prick test (D. farinae, D. pteronyssinus), and positive response in both fluoro-allergosorbent test (FAST), and PC20 methacholine test. Of the subjects, alternatively, 22 were assigned to the experimental group and 20 to control group. Bedding control consisted of the use of outer cotton covers, boiling them for 10 minutes fortnightly, and disinfecting bedding by sunlight fortnightly. The experimental group was under bedding control for 4 weeks. The data were collected from October 2000 to January 2001. The results were as follows: 1. After bedding control, the total amount of HDM allergens decreased significantly in the experimental group. However there was no significant difference in the decrease of the amount of HDM allergens between the two groups. 2. Of the asthma symptoms, there was significant difference only in the decrease of the frequency of dyspnea, and in the increase of sleeping disturbance between the two groups after bedding control. 3. After bedding control, PEFR increased in the experimental group whereas it decreased in the control group. However, neither change was significant. The above findings indicate that bedding control improved several asthma symptoms in asthmatics sensitive to HDMs. Accordingly, we suggest that bedding control is adopted as a useful nursing intervention in the field.
Adult
;
Aged
;
Allergens/*analysis
;
Animals
;
Antigens, Dermatophagoides/analysis
;
Asthma/*prevention & control
;
*Bedding and Linens
;
Dust
;
Female
;
Human
;
Male
;
Middle Aged
;
Mites/*immunology
;
*Peak Expiratory Flow Rate
8.Effect of an Air Cleaner with Electrostatic Filter on the Removal of Airborne House Dust Mite Allergens.
Santosh Rani AGRAWAL ; Hak Joon KIM ; Yong Won LEE ; Jung Ho SOHN ; Jae Hyun LEE ; Yong Jin KIM ; Sung Hwa LEE ; Chein Soo HONG ; Jung Won PARK
Yonsei Medical Journal 2010;51(6):918-923
PURPOSE: The effects of air cleaners on the removal of airborne indoor allergens, especially house dust mites (HDM), are still controversial. The objective of this study is to evaluate the effect of an air cleaner with an electrostatic filter on the removal of airborne mite allergens. MATERIALS AND METHODS: A dried HDM culture medium that contained mite body particles and excretions was dispersed in a chamber equipped with an electrostatic air cleaner. The number of airborne particles was recorded continuously by a dust spectrometer for 60 minutes. Airborne particles in the chamber were collected on a sampling filter at a flow rate of 10 L/min and the Der f 1 concentration in the filter extracts was measured by two-site ELISA. RESULTS: The air cleaner efficiently removed airborne HDM particles. The air cleaner removed airborne HDM particles (size 2-12.5 microm) 11.4 +/- 2.9 fold (cleaner operating for 15 minutes), 5.4 +/- 0.7 fold (cleaner operating for 30 minutes), and 2.4 +/- 0.2 fold (cleaner operating for 60 minutes) more than the removal of HDM particles by natural settle down. Removal kinetics differed according to the particle size of the airborne particles. The air cleaner decreased the concentration of Der f 1 in the extraction of airborne particles collected on the air sampling filter by 60.3%. CONCLUSION: The electrostatic air cleaner can remove airborne HDM allergens and may be useful as a supplementary environmental control tool for HDM sensitized respiratory allergic patients.
Air Pollution, Indoor/*analysis
;
Allergens/analysis
;
Animals
;
Antigens, Dermatophagoides/*analysis/*immunology
;
Culture Media/metabolism
;
Dust/analysis/immunology
;
Environment
;
Environmental Monitoring/methods
;
Enzyme-Linked Immunosorbent Assay/methods
;
Filtration
;
Humans
;
Kinetics
;
Mites
;
Particle Size
;
Static Electricity
9.The study of correlation between allergen and chronic rhinosinusitis.
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2009;23(14):633-638
OBJECTIVE:
To explore the effects of allergic factors in chronic sinusitis.
METHOD:
Skin prick test and specific serum IgE of 194 patients with chronic sinusitis were performed in our department before endoscopic sinus surgery from October, 2007 to October, 2008, and correlation between test results and clinical classification was analyzed retrospectively.
RESULT:
(1) Result of skin prick test was analyzed. Positive rate of house dust was 20. 6% (40/194), of dust mites 16.0% (30/194), of house dust mites 14.9% (29/194). (2) Positive rate of allergic specific serum IgE and skin prick test in experimental group was compared with that of control group. Positive rate of house dust mites, dust mites and house dust between groups were significantly different (P < 0.05). (3) Clinical classification of chronic sinusitis had a negative correlation with the specific serum IgE (house dust mites ,house dust and dust mites) about experimental group (P < 0.05).
CONCLUSION
Allergic factors was associated with etiopathogenesis and course of disease of chronic sinusitis.
Adolescent
;
Adult
;
Aged
;
Aged, 80 and over
;
Allergens
;
analysis
;
Animals
;
Asthma
;
etiology
;
immunology
;
Chronic Disease
;
Dust
;
immunology
;
Female
;
Humans
;
Immunoglobulin E
;
blood
;
Middle Aged
;
Pyroglyphidae
;
immunology
;
Retrospective Studies
;
Sinusitis
;
etiology
;
immunology
;
Skin Tests
;
Young Adult
10.Role of specific IgE, IgG and IgG4 antibodies to corn dust in exposed workers.
Hae Sim PARK ; Dong Ho NAHM ; Hee Yeon KIM ; Chang Hee SUH ; Kyu Sang KIM
The Korean Journal of Internal Medicine 1998;13(2):88-94
BACKGROUND AND METHODS: To evaluate the role of specific antibodies to corn dust (CD) and their relationship to respiratory dysfunction, we detected serum specific IgE(slgE) and IgG4(slgG4) antibodies by ELISA in 42 employees working in the animal feed industry and 27 unexposed controls. RESULTS: Our survey revealed that 15 (34.9%) subjects had work-related respiratory dysfunction associated with or without nasal symptoms. Among these subjects, eight had airway hyper-responsiveness to methacholine. Significant differences were noted in slgE and slgG4 between exposed and unexposed groups (p = 0.04, p = 0.00 respectively), but no difference was noted in slgG (p = 0.1). Although there was no significant differences in the prevalence of specific IgE antibody between symptomatic (29%) and asymptomatic groups (19%, p = 0.55), the specific IgE levels were significantly higher in symptomatic workers than in asymptomatic workers (p = 0.03). Specific IgG antibody was detected in 1 (6%) symptomatic and 4 (15%) asymptomatic workers (p = 0.46). Specific IgG4 antibody was detected in 11 (73%) of symptomatic and 21 (78%) of asymptomatic workers (p = 0.90). The higher prevalence of slgG4 antibody was noted in workers with slgE antibody (p = 0.001). The correlation between slgG and exposure duration was significant (r = 0.36, p = 0.02). There was no association between the prevalence of slgE, slgG, and slgG4 to exposure intensity, smoking or atopic status. CONCLUSION: These results suggested that the existence of slgG and slgG4 might represent a response to CD exposure, and that some unexposed subjects had slgG to CD. Specific IgE might play a role in the development of respiratory symptoms.
Analysis of Variance
;
Antibodies, Anti-Idiotypic/analysis*
;
Asthma/immunology*
;
Asthma/epidemiology
;
Chi-Square Distribution
;
Comparative Study
;
Corn/adverse effects*
;
Dust/adverse effects*
;
Enzyme-Linked Immunosorbent Assay
;
Human
;
IgE/analysis*
;
IgG/analysis*
;
Male
;
Occupational Diseases/immunology*
;
Occupational Diseases/epidemiology
;
Occupational Exposure/adverse effects
;
Reference Values
;
Respiratory Hypersensitivity/immunology*
;
Skin Tests
;
Smoking/immunology
;
Substances: IgE
;
Substances: IgG
;
Substances: Antibodies, Anti-Idiotypic