1.A case of neurofibroma with malignant potential in infant.
Journal of the Korean Society of Plastic and Reconstructive Surgeons 1993;20(6):1336-1339
No abstract available.
Humans
;
Infant*
;
Neurofibroma*
2.Pott's Paraplegia with Secondary Esophageal Fistula: 1 Case Report.
Eung Ha KIM ; Ji Sup LEE ; Duck Yun CHO
Journal of Korean Society of Spine Surgery 1997;4(1):175-179
No abstract available.
Esophageal Fistula*
;
Tuberculosis, Spinal*
3.Multiple Thoracic Disc Herniations: A Case Report.
Duck Yun CHO ; Eung Ha KIM ; Kwang Jin SONG
Journal of Korean Society of Spine Surgery 1997;4(1):170-174
No abstract available.
5.A STUDY ON THE ACCURACY OF THE IMPRESSION BODY ACCORDING TO MATERIALS AND FORMS OF THE INDIVIDUAL TOOTH TRAY.
Duck Woo RYU ; Ju Hwan LIM ; In Ho CHO
The Journal of Korean Academy of Prosthodontics 2000;38(2):242-254
Accurate impression is very important to achieve desirable prosthesis and there are many factors in taking a good impression. For example, types of impression material, types of impression tray, impression taking methods and so on. Recently individual tooth tray technique is accepted as obtaining good impression that can be applied to multiple abutment impression, heavy salivated patient, to minimize the effect of natural teeth' s undercuts and to reduce pain during cord packing procedures. The purpose of this study was to compare the accuracy according to materials and forms of the individual tooth tray which is clinically applied nowadays. Used materials in experiment were divided into 3 types (acrylic resin, Futar' occlusion, Blu-mousse) and forms were divided into 2 types (forming occlusal vent hole or not and forming marginal vent space or not). Stone master model from impression body and metal master model were measured by X-PLAN360d to compare occlusal surface discrepancy and marginal discrepancy. The results were as follows 1. In comparison of occlusal surface discrepancy and marginal discrepancy according to materials, groups with three materials showed no statistical difference. 2. In comparison of occlusal surface discrepancy and marginal discrepancy according to occlusal vent hole, groups with occlusal vent hole showed significantly less marginal discrepancy than groups with no occlusal vent hole(p<0.05). 3. In comparison of occlusal surface discrepancy and marginal discrepancy according to 0.5mm marginal-vent-space, groups with no 0.5mm-marginal-vent-space showed significantly less mar ginal discrepancy than groups with 0.5mm-marginal-vent-space(p<0.05). In summary, these results suggest that individual tooth tray made of 3 types of materials with occlusal vent hole and individual tooth tray made of acrylic resin with no marginal vent space showed good accuracy of impression. In addition, individual tooth tray which is made of bite registration materials may be more useful because of advantage in facility and timesaving aspect of fabrication.
Humans
;
Jaw Relation Record
;
Prostheses and Implants
;
Tooth*
6.A STUDY ON THE ACCURACY OF THE IMPRESSION BODY ACCORDING TO MATERIALS AND FORMS OF THE INDIVIDUAL TOOTH TRAY.
Duck Woo RYU ; Ju Hwan LIM ; In Ho CHO
The Journal of Korean Academy of Prosthodontics 2000;38(2):242-254
Accurate impression is very important to achieve desirable prosthesis and there are many factors in taking a good impression. For example, types of impression material, types of impression tray, impression taking methods and so on. Recently individual tooth tray technique is accepted as obtaining good impression that can be applied to multiple abutment impression, heavy salivated patient, to minimize the effect of natural teeth' s undercuts and to reduce pain during cord packing procedures. The purpose of this study was to compare the accuracy according to materials and forms of the individual tooth tray which is clinically applied nowadays. Used materials in experiment were divided into 3 types (acrylic resin, Futar' occlusion, Blu-mousse) and forms were divided into 2 types (forming occlusal vent hole or not and forming marginal vent space or not). Stone master model from impression body and metal master model were measured by X-PLAN360d to compare occlusal surface discrepancy and marginal discrepancy. The results were as follows 1. In comparison of occlusal surface discrepancy and marginal discrepancy according to materials, groups with three materials showed no statistical difference. 2. In comparison of occlusal surface discrepancy and marginal discrepancy according to occlusal vent hole, groups with occlusal vent hole showed significantly less marginal discrepancy than groups with no occlusal vent hole(p<0.05). 3. In comparison of occlusal surface discrepancy and marginal discrepancy according to 0.5mm marginal-vent-space, groups with no 0.5mm-marginal-vent-space showed significantly less mar ginal discrepancy than groups with 0.5mm-marginal-vent-space(p<0.05). In summary, these results suggest that individual tooth tray made of 3 types of materials with occlusal vent hole and individual tooth tray made of acrylic resin with no marginal vent space showed good accuracy of impression. In addition, individual tooth tray which is made of bite registration materials may be more useful because of advantage in facility and timesaving aspect of fabrication.
Humans
;
Jaw Relation Record
;
Prostheses and Implants
;
Tooth*
7.Impact of Subsidies for Labor and Management-directed Health Promotion Activities on Industrial Accidents Prevention.
Yunjeong YI ; Hye Sun JUNG ; Duck Yeon CHO ; Bokim LEE
Korean Journal of Occupational Health Nursing 2013;22(3):249-256
PURPOSE: This study was conducted to compare the rates of industrial accidents in workplaces that adopted the 2011 Workplace Health Promotion Subsidy Scheme before and after the implementation. METHODS: The study analyzed the raw data of industrial accidents of 304 workplaces which received subsidies for health promotion activities in 2011. The raw data covered the period from February 2010 to July 2012, based on the dates of industrial accidents. RESULTS: Workplaces subsidized for health promotion activities reported fewer occurrences in staff injuries and illnesses than before the subsidization, as the total number of industrial accident victims dropped from 0.35 to 0.24. The rate of industrial accidents also dropped from 0.49 to 0.35, with the number of working days decreased from 35,433 to 23.867, about 33%. CONCLUSION: The study showed that financial support for health-promoting activities contributed to the decease in industrial accidents, which is an important indication advocating the need for corporate and government investment on workers health promotion programs. Furthermore, this study is also significant as it is the first research conducted in Korea to examine the impact of a workers health promotion project using a direct indicator, the rate of industrial accidents.
Accidents, Occupational
;
Financial Support
;
Health Promotion
;
Investments
;
Korea
9.A Clinical Outcome of Automated Percutaneous Lumbar Discectomy: more than 4 years follow up.
Eung Ha KIM ; Chang Wan SEON ; Duck Yun CHO
The Journal of the Korean Orthopaedic Association 1998;33(3):819-825
An automated percutaneous lumbar discectomy(APLD) have been apphed for contained lumbar disc herniation. But suggested that more exclusion criteria than disc containment was needed to improve success rate. The purposes of this study are to evaluate cIinical outcome of more than 4 years follow up of APLD, to analysis the cause of failure for longer follow up period, and to define prognostic factor of APLD. The l04 patients with contained lumbar disc herniation were treated with APLD from March 1990 to November 1992 in National Medical Center. The surgical candidates were contained focal disc herniation in MRI, sciatica than back pain, failure to conservative management at least 6 weeks and clinical and radiological correlation. And patient were excluded from this data if they had history of previous lumbar surgery and compensation claims. Among them 74 cases were followed up for over 4 years (Mean: 5.3 years). The results were accessed by questionnaire using telephone or OPD follow up. The overall success rate was 84% on 3 months follow up, but 68.9% on more than 4 years follow up by four subjective criterias (Onik, 1987). Causes of decreasing success rate were reoperation, recurrence without specific cause or after sprain and heavy work. 76% of failed cases occurred within 1 year and 40% of them underwent open discectomy. The patient sex, treated level, duration of symptom were not influenced on success rate, but age was factor related to success rate. In this study we can assess the effectiveness of APLD within 3 months in most cases and then change treatment option according to patients status, and it seems that we need more exclusion criteria than disc containment in MRI and refined patient selection in order to decrease the failures.
Back Pain
;
Compensation and Redress
;
Containment of Biohazards
;
Diskectomy*
;
Follow-Up Studies*
;
Humans
;
Magnetic Resonance Imaging
;
Patient Selection
;
Surveys and Questionnaires
;
Recurrence
;
Reoperation
;
Sciatica
;
Sprains and Strains
;
Telephone
10.A Comparison of Flexible and Rigid Rods System in Transpedicular Dcrew Fixation of Degenerative Lumbar Spine.
Eung Ha KIM ; Kyu Bo LEE ; Duck Yun CHO
The Journal of the Korean Orthopaedic Association 1999;34(1):103-110
The transpedicular screw fixation is known to be capable of providing more secure correctional, force and rigid fixation to the spine. But it is often accompanied by various complications, including stress shield effects, loosening in osteoporotic spine, pseudoarthrosis, hardware problems and long-term change in motion behaviors at the adjacent motion segment and etc. The purpose of this study is to compare the flexible and rigid rods system in terms of complications and problems for various degenerative lumbar diseases. From September 1991 to November 1994, 41 patients were operated with the flexible rods system (group A) and 39 patients with the rigid rods system (group B). They were followed up for more than 4 years. The flexible rods system was composed of 41 cases of Wiltse system and the rigid rods system was composed of 29 cases of Diapason, 8 cases of TSRH and 2 cases of CD instrument. The resuits of the study were as follows: 1. By standard Cobb lateral measurement, 7 cases in group A and 10 cases in group B showed significant loss of sagittal angle (>4), post-operatively. 2. Hardware failure was noted in 7 cases in group A and 10 cases in group B. In group A, rod bending was seen in 4 cases, rod breakage in 2 and screw loosening in one. In group B, screw loosening was observed in 5 and screw-rod locking mechanism failure in 5 cases. 3. In spondylolisthesis patients, 10 cases in group A and 14 in group B, there was no statistically significant differences between the two groups in the reduction rate immediately after surgery and loss of reduction at the last follow up. 4. Clinical results were good to excellent in 85.4% of patients in group A and 82.1% of group B. No statistically significant differences between the two groups were found, 5. No statistically significant differences between the two groups were found with respect to degenerative changes at the adjacent motion segment to the fused level and pseudoarthrosis.
Follow-Up Studies
;
Humans
;
Pseudarthrosis
;
Spine*
;
Spondylolisthesis