1.Accuracy of the Point-Based Image Registration Method in Integrating Radiographic and Optical Scan Images: A Pilot Study
Journal of Korean Dental Science 2020;13(1):28-34
Purpose:
The purpose of this study was to investigate the influence of different implant computer software on the accuracy of image registration between radiographic and optical scan data.
Materials and Methods:
Cone-beam computed tomography and optical scan data of a partially edentulous jaw were collected and transferred to three different computer softwares: Blue Sky Plan (Blue Sky Bio), Implant Studio (3M Shape), and Geomagic DesignX (3D systems). In each software, the two image sets were aligned using a point-based automatic image registration algorithm. Image matching error was evaluated by measuring the linear discrepancies between the two images at the anterior and posterior area in the direction of the x-, y-, and z-axes. Kruskal–Wallis test and a post hoc Mann–Whitney U-test with Bonferroni correction were used for statistical analyses. The significance level was set at 0.05.Result: Overall discrepancy values ranged from 0.08 to 0.30 μm. The image registration accuracy among the software was significantly different in the x- and z-axes (P=0.009 and <0.001, respectively), but not different in the y-axis (P=0.064).
Conclusion
The image registration accuracy performed by a point-based automatic image matching could be different depending on the computer software used.
2.Effect of image matching experience on the accuracy and working time for 3D image registration between radiographic and optical scan images
The Journal of Korean Academy of Prosthodontics 2021;59(3):299-304
Purpose:
The purpose of the present study was to investigate the effects of image matching experience of operators on the accuracy and working time of image registration between radiographic and optical scan images.
Materials and Methods:
Computed tomography and optical scan of a dentate dental arch were obtained. Image matching between the computed tomography and the optical scan (IDC S1, Amann Girrbach, Koblah, Austria) was performed using the point-based automatic registration method in planning software programs (Implant Studio, 3Shape, Copenhagen, Denmark) using two different experience conditions on image registration: experienced group and inexperienced group (n = 15 per group, N = 30). The accuracy of image registration in each group was evaluated by measuring linear discrepancies between matched images, and working time was recorded. Independent t test was used to statistically analyze the result data (α = .05).
Results:
In the linear deviation, no statistically significant difference was found between the experienced and inexperienced groups. Meanwhile, the working time for image registration was significantly shorter in the experienced group than in the inexperienced group (P = .007).
Conclusion
Difference in the image matching experience may not influence the accuracy of image registration of optical scan to computed tomography when the point-based automatic registration was used, but affect the working time for the image registration.
3.Fabrication of functionally customized fixed prosthesis in a hemimandibulectomy patient with fibular graft using double scan technique: A case report
The Journal of Korean Academy of Prosthodontics 2022;60(2):195-201
Hemimandibulectomy and free fibular flap (FFF) in patients with squamous cell carcinoma could disturb the functional movement of the mandible. The muscular function in the sectioned side was compromised because of the incompetency of the muscle attachment to the mandible, leading to the unstable occlusal contact in the centric and eccentric occlusion. In this report, we present a case of a 63-year-old male who underwent cancer surgery and reconstruction with fibular graft, and he needed a fixed dental prosthesis to restore tooth loss in the anterior region. Occlusal contact change and instability were found according to the bite force in the centric relation and eccentric movement. This case report aimed to present the prosthetic procedure for fabricating the functionally optimized fixed prosthesis wherein the functionally generated path (FGP) technique and digital imaging method were applied to replicate mandibular movement and vertical dimension of the patient.
4.Effect of image matching experience on the accuracy and working time for 3D image registration between radiographic and optical scan images
The Journal of Korean Academy of Prosthodontics 2021;59(3):299-304
Purpose:
The purpose of the present study was to investigate the effects of image matching experience of operators on the accuracy and working time of image registration between radiographic and optical scan images.
Materials and Methods:
Computed tomography and optical scan of a dentate dental arch were obtained. Image matching between the computed tomography and the optical scan (IDC S1, Amann Girrbach, Koblah, Austria) was performed using the point-based automatic registration method in planning software programs (Implant Studio, 3Shape, Copenhagen, Denmark) using two different experience conditions on image registration: experienced group and inexperienced group (n = 15 per group, N = 30). The accuracy of image registration in each group was evaluated by measuring linear discrepancies between matched images, and working time was recorded. Independent t test was used to statistically analyze the result data (α = .05).
Results:
In the linear deviation, no statistically significant difference was found between the experienced and inexperienced groups. Meanwhile, the working time for image registration was significantly shorter in the experienced group than in the inexperienced group (P = .007).
Conclusion
Difference in the image matching experience may not influence the accuracy of image registration of optical scan to computed tomography when the point-based automatic registration was used, but affect the working time for the image registration.
5.Burnishing effect on marginal misfit of implant-supported screw-and-cement retained prostheses: A case report
The Journal of Korean Academy of Prosthodontics 2020;58(3):239-243
When the marginal fit of fixed dental prosthesis decreases, biological and technical complications, such as plaque accumulation, periodontal disease, hypersensitivity, components fracture, cement loss, can happen. The complications affect the long-term success and survival of prostheses. This case report describes a clinical procedure to minimize the marginal gap of implant-supported screw-and-cement retained prosthesis by removing prosthesis-abutment complex and burnishing the interface area. The marginal gap was measured before and after the burnishing using a stereomicroscope and compared. This technique improves the marginal fit, thereby contributing the longevity of the prosthesis.
6.Digital approach for fabrication of zirconia restoration with optimal gingival adaptation after tooth extraction: A case report
The Journal of Korean Academy of Prosthodontics 2020;58(3):217-220
Conventionally, when a zirconia fixed dental restoration is planned, the interim restoration is made manually and the final restoration is fabricated by the silicone impression taking at the prosthodontic stage. This conventional workflow does not provide direct relation between interim and final restorations. Moreover, the predictability of the final restoration could be low. Nowadays, the CAD/CAM based restoration fabrication and related digital techniques are developed and being applied in dentistry in multiple ways. This case report introduces a digital workflow for fabricating an optimal gingival adaptation and predictability of monolithic zirconia restoration by using CAD/CAM interim restoration, intra oral scan, and image superimposition technique in a case that required tooth extraction.
7.In vitro evaluation methods on adaptation of fixed dental prosthesis.
Hyunho LEE ; Du Hyeong LEE ; Kyu Bok LEE
Journal of Dental Rehabilitation and Applied Science 2017;33(2):63-70
Clinically, the fit of fixed prosthesis is an essential element for successful restoration. The fit of prosthesis is largely classified into marginal fit and internal fit, and various methods to assess these have been introduced including microscopic margin measurement, cross-sectional measurement, silicone replica technique, 3-dimensional scanning data superposition, weight technique and micro CT scanning. Thus, this study is aimed at proposing a more convenient and accurate measurement method of fits in a digital environment by comparatively analyzing the advantages and disadvantages of each known method based on existing literature.
Crowns
;
Dental Prosthesis*
;
In Vitro Techniques*
;
Methods*
;
Prostheses and Implants
;
Replica Techniques
;
Silicon
;
Silicones
;
Tomography, X-Ray Computed
8.Ectopic pregnancy following laparoscopic tubal sterilization.
Hyeong Jong LEE ; Deok Man KIM ; Ki Hyun CHO ; Taek Hoon KIM ; Du Ryong LEE ; Young Wook SUH
Korean Journal of Obstetrics and Gynecology 1991;34(11):1611-1618
No abstract available.
Female
;
Pregnancy
;
Pregnancy, Ectopic*
;
Sterilization, Tubal*
9.Analysis of implant strain value exerted using different screw tightening protocols in screw-retained 3-unit prostheses
Sang-Beom KIM ; Du-Hyeong LEE ; Cheong-Hee LEE
The Journal of Korean Academy of Prosthodontics 2020;58(4):321-327
Purpose:
The purpose of this study was to measure and compare the strain value exerted on the cervical area using different screw tightening protocols in implant-supported, screw-retained 3-unit prostheses.
Materials and methods:
Strain gauges were attached to four implants: two external and two internal. Thereafter, two study model were designed each type using acrylic resin. CAD-CAM was used to design hex and nonhex abutments for each group (EH, ENH, IH, and INH group) and Screw-cement-retained prostheses were also designed using a nonprecious base metal. Abutment was fixed with 10 Ncm torque, and the prosthesis was cemented. Screws were fixed with 30 Ncm torque using different three protocols. After 5 min, the strain gauge level was measured, and group analysis was performed (α=.05).
Results:
External group showed significantly lower strain values than internal group and the EH group showed significantly lower strain values than the ENH group (P<.05). There was no difference in strain value based on the types of screw tightening protocols in same group (P>.05). The IH group exhibited significantly higher strain values than the INH group and the IH group showed a significant difference in strain values based on the types of screw tightening protocols used (P<.05).
Conclusion
There was no significant effect on the external type in the implant-supported, screw-retained prostheses. However, strain values were high in the internal type, and the types of screw tightening protocol significantly affected these implants.
10.Comparison of digitalized fabrication method for interim removable partial denture: case reports
Yoon-Jeong SHIN ; Cheong-Hee LEE ; Du-Hyeong LEE
The Journal of Korean Academy of Prosthodontics 2023;61(4):379-385
With the recent development of digital dentistry, fully digitalized methods for fabricating dentures, using intraoral scans and computer-aided design/computer-aided manufacturing (CAD-CAM), are getting popular. Digital methods have the advantage of simplifying the fabrication process in the clinic and laboratory, supplementing digital data. This case report shows a fully digital fabrication method for interim removable dentures in a patient with anterior tooth loss in which implant placement is impossible or delayed. Interim removable dentures were fabricated using two methods. One method is printing tooth and base parts separately and combining, and the other method is printing the whole denture at one time and coloring on the base part. Afterward, dentures were delivered and adaptation was evaluated using the triple scan technique. The extracted site was scanned intraorally (first scan) and the interim removable denture was digitally scanned both intraorally (second scan) and, after removal extraorally (Third scan). In both method, denture adaptation was shown favorable. We report this case report as both the patient and the operator were satisfied with a simplified process using a fully digital method in the clinic.