1.Micron three-dimensional reconstruction image of a rabbit lower limb lymphedema model: Feasibility of synchrotron radiation in-line phase contrast imaging technique
Dongyue LI ; Lu ZHANG ; Hongli SHI ; Shuqian LUO
Chinese Journal of Tissue Engineering Research 2009;13(48):9451-9454
BACKGROUND: The conventional X-ray imaging has low absorption contrast for lymphoedema, and the resolution is about mm level, which is not conducive to early diagnosis. Micro-imaging of biological soft tissues can be achieved by phase-contras imaging technique. OBJECTIVE: Using synchrotron radiation in-line phase contrast imaging technique to achieve the lymphoedema model imaging and observe the lesions characteristic of lymphatic vessels. DESIGN, TIME AND SETTING: Observational experiment. The lymphoedema model was prepared at the Capital Medical University from May to June in 2009. And the experiment was completed in Shanghai Synchrotron Radiation Facility (SSRF) BL13W1 in June 2009. MATERIALS: Five New Zealand rabbits were prepared for lower extremity lymphoedema models. METHODS: The lower extremity lymph node eradicates operation was performed on rabbits to result in lower extremity lymphoedema. And the synchrotron radiation in-line phase contrast imaging technology was used to collect the projected image of specimens within the 180°, and to reconstruct three-dimensional image. MAIN OUTCOME MEASURES: Severity of lymphatic vessels and the wall thickness. RESULTS: The lymphatic vessel was swollen, bent and distorted. And the lymphatic vessel generates lateral branches in order to promote lymphatic drainage, which was clearly observed from the image obtained by phase contrast imaging technology.CONCLUSION: The use of synchrotron radiation type coaxial imaging technology can be achieved for lymphedema model for micro-imaging, which has certain significance to the early diagnosis of lymphedema.
2.Establishment and Application of TaqMan Real-Time PCR assay for Diagnosis of Streptococcus Pneumoniae
Dongyue LU ; Helu LIU ; Yue HE ; Peipei LI ; Hong LIANG ; Shue ZHU
Journal of Modern Laboratory Medicine 2014;(5):60-63
Objective To develop TaqMan real-time PCR assay for detection and identification of streptococcus pneumonia iso-lated from children CAP.Methods Based on the sequences of lytA gene,primers and probe were designed and the assay was optimized.Then 1 504 sputum samples were detected by culture and the developed assay with double-blind testing.Results The lower limit of detection in the developed real-time PCR assay was 18.75 cfu/PCR,and had no cross reaction.141 strep-tococcus pneumonia strains were detected from 1 504 samples and 140 were isolated by culture.The whole process just nee-ded 2.5 h.Conclusion The established assay is rapid,simple,high sensitivity and specificity.It is not only valuable for the i-dentification of streptococcus pneumonia,but also provide evidence for antibiotic therapy.
3.Clinical Applification of Combined Detection of Pencilliosis Marneffei in a Non-HIV-infected Child
Weina HE ; Danhong SU ; Dongyue LU ; Hua DING ; Jianjiang HUA ; Yue HE ; Hong LIANG
Journal of Modern Laboratory Medicine 2015;(4):87-90
Objective To study the diagnostic value of pencilliosis marneffei (PM)in a non-HIV-infected child with the com-bined detection of aspergillosis galactomannan,fungus Glucan(1-3)-β-D and boold culuture.Methods The venous blood specimen from the child was collected for the quantified detection of aspergillosis galactomannan,fungus Glucan(1-3)-β-D. The growth and colonial morphology of fungus was inspected with the positive blood culture and the characteristics of fun-gus smear were observed under microscope.Results The result of aspergillosis galactomannan was 14.45 μg/L and fungus Glucan (1-3)-β-D 77.14 pg/ml.Penicillium marnrffei was identified using blood culture.It was mycelia form under 25℃ and the salouraud medium produced water soluble claret-red pigment produced.It was mycelia form under 35℃ and the colony was gyri creases,the characteristic broom-like hypha and separation hypha could be found under microscope.Conclusion It is effective for the early diagnosis and therapy of PM with the combination detection of aspergillosis galactomannan,fungus Glucan (1-3)-β-D and boold culuture and have better clinical diagnosis value.
4.Phase contrast imaging and three-dimensional reconstruction of mouse liver under different conditions.
Lu ZHANG ; Dongyue LI ; Hongli SHI ; Shuqian LUO
Chinese Journal of Medical Instrumentation 2010;34(2):86-88
The liver sample of mouse under different conditions is investigated in this paper, and the three-dimensional vessel system of mouse liver is established. The experiments were performed at X-ray imaging and biomedical application beamline (BL13W1) of Shanghai Synchrotron Radiation Facility (SSRF). The results show that dry liver sample has the best imaging quality. By the approach of filter back projection (FBP), the tomography images are obtained. The vessel tree is reconstructed by the use of surface rendering. It reveals that in-line phase contrast imaging technique has the ability to visualize structures inside mouse liver and has the potential to be used in liver imaging in the future.
Animals
;
Imaging, Three-Dimensional
;
methods
;
Liver
;
diagnostic imaging
;
Mice
;
Mice, Inbred Strains
;
Tomography, X-Ray Computed
;
methods
5.Early-onset facioscapulohumeral muscular dystrophy with Coats syndrome: a case report
Yiqi LIU ; Dongyue YUE ; Hua LIU ; Wenhua ZHU ; Wei ZHANG ; Chongbo ZHAO ; Jiahong LU
Chinese Journal of Neurology 2019;52(1):46-48
Early-onset facioscapulohumeral muscular dystrophy is a rare clinical syndrome characterized by severe muscle weakness started in early childhood,with extramuscular manifestations such as retinal vascular tortuosity,sensorineural hearing loss and epilepsy.Herein we report a case with early-onset facioscapulohumeral muscular dystrophy and Coats syndrome.Early diagnosis of Coats syndrome is critical for the prognosis.
6. The value of protection device in microwave ablation at canine liver risk area
Guangbin HE ; Xiao LU ; Dongyue GU ; Qian YANG ; Yue ZHANG ; Haiying QIN ; Xiaodong ZHOU
Chinese Journal of Ultrasonography 2018;27(7):630-635
Objective:
To explore the application value of protective device in microwave ablation at canine liver risk area, and the role of the device in reducing complications during ablation.
Methods:
Six healthy mongrel dogs were randomly divided into two groups: group A, used protective devices; group B, unprotected. Conventional gray-scale ultrasound and contrast-enhanced ultrasound (CEUS) were performed before treatment to identify the ablation area (the right lobe of the liver near diaphragm, 1 cm from the surface of the liver). The two groups were treated percutaneous puncture liver microwave ablation under real time ultrasound-guided with the same ablation power (50 W) and equivalent ablation time (600 s). Liver specimens were evaluated histological examination to evaluate the necrotic area of ablation and the degree of diaphragm′s injury.
Results:
①There was no significance difference in the ablation range between two groups[ (3.3±0.1)cm vs (3.5±0.1)cm,