1.Diagnostic value of serum angiopoietin-2 level in pancreatic cancer.
Ru-Gen WAN ; De-Bao CHEN ; Yong-Gang LOU ; Mao-Feng WANG ; Qiao-Hong ZHANG ; Dan-Xia JIN ; Sun-Hong ZHOU
Chinese Journal of Oncology 2011;33(1):47-49
OBJECTIVETo evaluate the diagnostic value of serum angiopoietin-2 (Ang-2) level in pancreatic cancer patients.
METHODSSerum Ang-2 level was measured by enzyme-linked immunosorbent assays (ELISA) in samples from 116 patients with pancreatic cancer, 50 patients with chronic pancreatitis, and 50 normal control subjects.
RESULTSThe serum Ang-2 level in patients with pancreatic cancer [(1539.0 ± 449.3) ng/L] was significantly higher than those in patients with pancreatitis [(1044.6 ± 246.1) ng/L, P < 0.01] and normal control subjects [(1075.6 ± 228.2) ng/L, P < 0.01]. There was no significant difference of serum Ang-2 levels between patients with pancreatitis and normal controls. Pancreatic caner patients with lymph node metastasis had a significantly higher serum Ang-2 level [(1890.1 ± 354.9) ng/L] than those without metastasis [(1212.1 ± 224.2) ng/L, P < 0.01]. The area under ROC curve of serum Ang-2 level for diagnosis of pancreatic cancer was 0.819.
CONCLUSIONThe serum Ang-2 level can be a useful indicator for diagnosis of pancreatic cancer.
Adult ; Aged ; Angiopoietin-2 ; blood ; Enzyme-Linked Immunosorbent Assay ; Female ; Humans ; Lymphatic Metastasis ; Male ; Middle Aged ; Neoplasm Staging ; Pancreatic Neoplasms ; blood ; diagnosis ; pathology ; Pancreatitis ; blood ; ROC Curve ; Retrospective Studies
2.Calculation and Verification Method of Three-Dimensional Center of Gravity Based on Human Joint Points
Hao DING ; Dongyang XIA ; Siji DING ; Shimeng SHENG ; Xinru XU ; Kun SHANG
Journal of Medical Biomechanics 2024;39(1):157-163
Objective To explore the accuracy of the multiplication coefficient method and the moment synthesis method for determining the spatial position of the center of gravity(CoG)of the human body based on machine vision.Methods The mechanical measurement platform was built,and the three-dimensional(3D)human body CoG measurement method under static and dynamic conditions were designed to calculate the space coordinates of the CoG.Through experiments,the calculation accuracy of the multiplication coefficient and moment synthesis method were studied and analyzed.Results In the static experiments,the calculation results of the torque synthesis method were more accurate than those of the multiplication coefficient method for each dimension.The errors in the 3D CoG of the human body in the X,Y,and Z directions calculated using the torque synthesis method were 3.9%,4.1%,and 8.5%,respectively.In the dynamic experiment,the average and relative errors of the torque synthesis method in the X or Y direction were lower than those of the multiplication-coefficient method.When the action decomposition method was used to analyze the height direction of the CoG along the Z axis,the final rendering effect of the torque synthesis method improved.Conclusions The accuracy of the 3D CoG calculated by the moment synthesis method was relatively high,and was closer to the measurement data of the mechanical measurement platform.The 3D CoG calculated using the moment synthesis method can replace the mechanical measurement platform and can be used in subsequent studies.
3.Preliminary experience of endovascular revascularization for chronic long segment internal carotid artery occlusion
Dongyang CAI ; Tongyuan ZHAO ; Tianxiao LI ; Jiangyu XUE ; Kun ZHANG ; Jinchao XIA ; Bowen YANG ; Yingkun HE
Chinese Journal of Radiology 2018;52(6):457-462
Objective To explore the feasibility,safety and effect of endovascular revascularization for chronic long segment internal carotid artery occlusion. Methods The cases of chronic long segment internal carotid artery occlusion who were treated by endovascular revascularization in our center from May 2015 to April 2017 were reviewed. Eleven cases met the inclusion criteria:the duration of the occlusion was more than three weeks and the segment of the occlusion was beyond the petrosal segment of internal carotid arteries from the initial segment. All of the cases had the related symptoms and had declining cerebral perfusion. The analysis index included:baseline information,radiological information,perioperative results, clinical follow-up and imaging follow-up. The imaging follow-up index were the re-stenosis or re-occlusion of the revascularized artery. Results The occlusion was recanalized successfully in 9 of 11 patients,the two procedures were abandoned after repeated attempts and the guide wire could not reach the true lumen when navigating in the cavernous segment. Six cases of the nine successfully recanalized cases accepted perfusion-weighted imaging scan. Cerebral perfusion of all the cases were improved. Thrombus shifting was observed in one case and occluded a subbranch,mechanical thrombectomy was performed successfully,the case was recovered well without sequela. No symptomatic stroke or death was happened in the perioperative period. All of the nine cases who successfully recanalized acquired clinical follow-up,median follow-up time was ten months(4—28 months). No ischemic stroke and death happened after the procedures. Seven of nine cases improved in the clinical symptoms. Five cases accepted the imaging follow-up. The meantime was six months. No re-occlusion was happened. Conclusions Endovascular revascularization for chronic long segment internal carotid artery occlusion is feasible,safe,and short-term effective. More clinical research is needed to verify the long-term effect.
4.Effects of vitamin K on osteoblastic bone formation and osteoclastic bone absorption
Yizhong JIANG ; Tianshuang XIA ; Hailiang XIN ; Yu'e JIN ; Yiping JIANG ; Liming XUE
Journal of Pharmaceutical Practice 2020;38(4):340-345
Objective To compare the effects of vitamin K1 (VK1), vitamin K2 (MK4), vitamin K2 (MK7) and vitamin K3 (VK3) on bone formation and bone absorption. Methods Osteoblasts were isolated from calvaria of newborn rats and osteoclasts were induced by receptor activator of nuclear factor-κ B ligand (RANKL). ALP and TRAP activity were measured by diphenyl phosphate method. Osteoclast metabolic activity was measured by Celltiter kit. The inhibition of cathepsin K (CTSK) was measured by Z-FR-MCA fluorescent substrate and collagen substrate degradation. Results MK4 and MK7 at 0.1~1 μmol/L significantly increased the proliferation of osteoblasts (P<0.05) and at 1 μmol/L increased ALP activity and bone nodule formation area. VK3 inhibited bone nodule formation (P<0.05). VK1,VK3,MK4 and MK7 at 1 μmol/L had no effect on osteoclastic bone absorption. MK4 and MK7 significantly inhibited TRAP activity at 0.1~1 μmol/L (P<0.05), while VK1 and VK3 did not show the inhibitory effect. The inhibition of MK4 at 25 μmol/L on CTSK binding to Z-FR-MCA substrate activity is 58.9% and the inhibition of MK4 at 100 μmol/L on collagen degradation of CTSK activity is 73.2%. Conclusion Compared with VK1 and VK3, MK7 and MK4 significantly increase osteoblast activity and inhibit osteoclast bone absorption, MK4 inhibits osteoclast CTSK enzyme activity.
5.Experimental Study on Puncture Mechanical Properties of Biomimetic Materials
Mengfei KAN ; Hao DING ; Siji DING ; Yi ZHUANG ; Dongyang XIA ; Haoyu LIU
Journal of Medical Biomechanics 2022;37(1):E137-E141
Objective To obtain a more suitable puncture method for venipuncture robot through experiments.Methods By using different puncture speeds and angles for biomimetic materials, the force-time curves by various puncture methods were obtained. Results During puncture process, with the increase of the puncture angle, a smaller puncture force was required. The faster puncture speed would lead to a larger puncture force. Conclusions The 40°-45° puncture angleand the 120-300 mm/min puncture speed should be used for designing the puncture method of venipuncture robot. The results provide references for selecting the puncture angle and speed of the venipuncture robot.
6.Puncture and Needle Picking Action of Venipuncture Manipulator
Hao DING ; Yi ZHUANG ; Mengfei KAN ; Dongyang XIA ; Siji DING ; Shimeng SHENG ; Xinru XU ; Kun SHANG ; Geer YANG ; Jie LÜ
Journal of Medical Biomechanics 2023;38(2):E375-E381
Objective To propose a new multi-joint series venipuncture system, explore the mechanics and kinematics-based related control problems involved in needle insertion and needle picking during the puncture process, and verify feasibility of this system. Methods A puncture manipulator was built, and needle displacement control algorithm was proposed by combing with the puncture mechanics model. The the forward kinematics was calculated by using DH method, so as to obtain the tip coordinates. Then the inverse kinematics was calculated by using the geometric method. The forward and inverse processes were closely connected. The position error of the end coordinates before and after needle picking was compared by using the method of kinematics positive solution-inverse solution-re-positive solution. Finally, experimental verification and simulation were conducted by combining with the physical object. Results Through simulation and experiments, accuracy of the theoretical model was verified. The needle insertion algorithm could be used to achieve success with only one needle insertion, which provided theoretical basis for the control of robot arm. The position error before and after needle picking could be controlled within 1 mm from the end trajectory. The end needle tip of robot arm was almost kept fixed during the needle picking process. Therefore, this needle picking scheme was feasible and could basically verify that the needle picking action of robot arm met the accuracy and safety requirements. Conclusions The venipuncture manipulator truly simulates the needle insertion and needle picking action during the puncture process, and can safely and accurately realize the needle insertion and needle picking action with needle tip as the fixed point, indicating that it has certain clinical value.
7.A phase Ⅲ clinical trial study on the safety and immunogenicity of ACYW135 group meningococcal conjugate vaccine inoculated in 3 month old infants
Zhiqiang XIE ; Dongyang ZHAO ; Haitao HUANG ; Jinbo GOU ; Wei ZHANG ; Yongli YANG ; Lili HUANG ; Yanxia WANG ; Xue WANG ; Lifeng XU ; Tao ZHU ; Shengli XIA
Chinese Journal of Preventive Medicine 2020;54(9):947-952
The aim of this study was to evaluate the safety and immunogenicity of the first domestic ACYW135 meningococcal conjugate vaccine and a control vaccine named AC group meningococcal conjugate vaccine for 3 months (90-119 days) infants. From February 2017 to June 2018, a randomized, blinded, and similar vaccine-controlled clinical trial design was adopted at the Henan Vaccine Clinical Research Base. The subjects were 3 months old healthy infants, a total of 720, based on a 1∶1 ratio. The random allocation table for entry was randomly assigned to the experimental group and the control group. According to the 3, 4, and 5 month-old vaccination procedures, the subjects were vaccinated with test vaccine (ACYW135 group meningococcal conjugate vaccine) and control vaccine (group A group C meningococcal polysaccharide conjugate vaccine), of which 720 were given the first dose, 696 were given the second dose (test group: 346; control group: 350), and 692 were given the third dose (test group: 344; Control group: 348). The overall adverse reaction rate of the test vaccine was 21.90% (230 cases), which was lower than the 32.04% (339 cases) of the control vaccine (<0.001). The incidence of systemic adverse reactions was 19.52% (205 cases), which was lower than that of the control vaccine (27.69%) (293 cases) (<0.001). The local adverse reaction rate was 3.04% (32 cases), which was lower than the control group (7.84%) (83 cases) (<0.001). The graded adverse reaction test vaccine was 0.57% (6 cases), which was lower than the control group of 2.36% (25 cases) (<0.001). The positive conversion rate of anti-bacterial serum antibodies showed that there was no significant difference between the test vaccine group A (91.42%), C (88.76%) and the control vaccine (92.92%) (87.02%) (>0.05). Group Y and W135 was 88.17% (298 cases), 99.41% (336 cases), respectively. The GMT results showed that the test vaccine group A was 56.24, the control vaccine was 57.43 (>0.05); the group C test vaccine (43.53) was higher than the control group (27.28) (<0.001). The group Y and W135 are 89.22 and 140.66, respectively. Among them, the proportion of the group C GMT antibody ≥ 1∶128 for test vaccine (31.07%, 105 cases) was higher than the control vaccine (16.22%, 55 cases) (<0.001). ACYW135 group meningococcal conjugate vaccine has more safety and immunogenicity after application to 3 month old infants.
Antibodies, Bacterial
;
Humans
;
Infant
;
Meningococcal Vaccines
;
adverse effects
;
immunology
;
Vaccines, Conjugate