1.Respiratory prediction algorithm based on adaptive neuro-fuzzy inference system
Dan ZHU ; Shanda MA ; Wei WANG ; Dongshan FU
International Journal of Biomedical Engineering 2018;41(1):44-50
Objective To study an accurate prediction algorithm for irregular respiratory movements,effectively compensate for the time delay of radiotherapy systems,so as to improve the target accuracy of imageguided tracking or gated radiotherapy for thoracic and abdominal tumors.Methods A prediction algorithm based on an adaptive neuro-fuzzy inference system (ANFIS) was proposed to precisely predict irregular respiratory motion.The ANFIS model structure adopted the position and velocity of respiratory motion as input parameters to construct an N×N fuzzy set that combines position and velocity,and to establish a training set through historical data.In the prediction,if the position or velocity in the latest input signal was out of the range of the training set,the position or velocity would be adjusted accordingly and treated as the input parameter of the ANFIS model for prediction.The ANFIS was evaluated using 20 cases of irregular respiratory clinical data from CyberKnife-treated thoracic and abdominal tumors patients.The accuracy of the four typical prediction algorithms,including ANFIS,neural network (NN),support vector machine (SVM),and CyberKnife Synchrony,was compared by retrospective offline analysis.Results The ANFIS algorithm showed better performance than NN,SVM and Synchrony in normalized root mean square error (nRMSE),the maximum error (Max),and the number of errors greater than 1 mm.Conclusions The accuracy and robustness of the ANFIS algorithm are superior to NN,SVM and CyberKnife Synchrony.The ANFIS can better predict irregular respiratory signals.
2.Research status of solutions for main problems in clinical application of cone-beam CT
Chinese Journal of Radiation Oncology 2021;30(10):1099-1104
Since the application of image-guided radiotherapy in clinical practice, cone-beam CT (CBCT) has become the most widely employed image-guided device. However, some problems remain to be cautioned in the application of CBCT, such as certain errors in the setup errors before and after the correction of CBCT, the failure of CBCT to correct dynamic changes, whether the influence of application frequency of CBCT on patients’ boundary of clinical target volume can be reduced, imaging conditions of CBCT lack of a certain degree of flexibility, and the effect of clinical value and application cost on the practicality of CBCT. Only by fully understanding the problems in CBCT application can CBCT be applied more reasonably and scientifically.