1.Effect of He's Santong Method of Acupuncture for Treatment of Cervical Spondylosis of Nerve-root Type
Dongqing PENG ; Yuxi DONG ; Yunxia LIU
Journal of Traditional Chinese Medicine 1993;0(03):-
Objective To observe the effect of He's Santong method (Three ways to remove obstruction) of acupuncture for treatment of cervical spondylosis of nerve-root type.Methods The 52 patients with nerve-root type cervical spondylosis were randomly divided into two groups, 26 in each. The treatment group was treated by He's Santong method of acupuncture while the control group was administered Gentongping Granule, 2 weeks as one course. The therapeutic effect was evaluated by comparing the scores of symptoms, visual analogue scale (VAS) and changes in hemorheology after treatment.Results The total effective rate of the treatment and control groups was 96.1% and 69.2% respectively with a significant difference between (P
2.Relationship between prepregnancy body mass index weight gain during pregnancy and offspring body composition during preschool age
Chinese Journal of School Health 2022;43(7):1090-1094
Objective:
To explore the relationship between prepregnancy body mass index, weight gain during pregnancy with preschool obesity and body composition in offspring, so as to provide evidence for gestational weight gain and childhood obesity prevention.
Methods:
A total of 1 333 preschool children were recruited from 3 kindergartens in Tianjin from September to December 2020. Structured questionnaire was used to collect children s lifestyle information. Height, weight and body fat mass of children were assessed, and body fat percentage (FM%), fat mass index (FMI) and non fat mass index (FFMI) were calculated. Maternal medical records were collected and the mothers were grouped according to their prepregnancy weight status and weight gain during pregnancy. χ 2 test, t test, linear regression model and Logistic regression were used to analyze the differences of obesity and body composition among different groups.
Results:
The prevalence of overweight and obesity in preschoolers was 12.7% and 7.7%. After adjusting maternal age and delivery, gestational age, gender, age and lifestyle of children, the correlation between maternal pre pregnancy BMI,gestational weight gain with obesity and body composition indexes of children in preschool age was statistically significant ( P <0.05). For mothers with normal weight before pregnancy, excessive weight gain during pregnancy increased risk of high FM% and high FMI in offspring ( OR=1.81, 1.68, P <0.05). There was no significant correlation between maternal weight gain during pregnancy with offspring obesity and body composition among mothers with prepregnant overweight or obesity.
Conclusion
Maternal weight status before pregnancy and weight gain during pregnancy are correlated with obesity and body composition in the preschool age of offspring. It is suggested that mothers should maintain appropriate weight status before and during pregnancy.
3.Identification of a novel CRYGC mutation in a pedigree affected with congenital cataracts.
Jing ZHANG ; Donglan SUN ; Yacong WANG ; Weihong MU ; Yuanyuan PENG ; Dongqing MI
Chinese Journal of Medical Genetics 2019;36(7):697-700
OBJECTIVE:
To explore the genetic basis for a Chinese pedigree affected with congenital cataracts.
METHODS:
Clinical data and peripheral blood samples were collected for the pedigree. Following extraction of genomic DNA, whole exome sequencing was carried out to detect genetic variants. Candidate variants were verified by familial co-segregation analysis and Sanger sequencing. Bioinformatics analysis was carried out to predict the function of mutant genes.
RESULTS:
By comparing variants identified among affected and unaffected individuals, a heterozygous variant, c.110 G>C (p.R37P), was identified in exon 2 of the CRYGC gene among all patients, which also matched the criteria for potential disease-causing mutations. The result was confirmed by Sanger sequencing.
CONCLUSION
The c.110G>C variant of the CRYGC gene probably underlay the congenital cataracts in this pedigree.
Asian Continental Ancestry Group
;
Cataract
;
congenital
;
genetics
;
China
;
Heterozygote
;
Humans
;
Mutation
;
Pedigree
;
gamma-Crystallins
;
genetics
4.Tolerance range of breast cancer patients with set?up errors after volume modulated radiotherapy
Dongqing LI ; Tao LIN ; Jingping YU ; Xinchu NI ; Liugang GAO ; Mingya PENG
Chinese Journal of Radiological Medicine and Protection 2018;38(11):819-823
Objective To predict the tolerance range of set-up errors in clinical practice by predicting the virtual set-up errors of postoperative radiotherapy patients for breast cancer. Methods A retrospective analysis was made of the patients who underwent radiotherapy after breast cancer surgery in recent 3 years. According to different treatment method, 10 cases of breast cancer after modified radical mastectomy and 10 cases after breast conserving radical mastectomy were selected. The target area was delineated, the volume modulated radiation therapy plan was made, the virtual moving error of the center point of the plan was moved, and the maximum moving error was 5 mm by 1 mm step. After recalculating the dose, the corresponding data including the clinical target areas ( CT ) , CTV ( V50 ) , average heart volume, V20 of the affected lung and CTV volume were recorded. SPSS 19. 0 software was used for statistical analysis, and repeated measurement of variance analysis was used to analyze the changes of the actual dose in the target area after moving the center point. Linear regression analysis method was used to analyze the correlation between the CTV volume and the dose change after the CTV moving midline. Results The virtual set-up error had little influence on the axis direction of the approximate mammary tangent direction, while the vertical direction of the approximate mammary tangent direction had greater influence. After moving more than 3 mm on the vertical axis, the CTV ( V50 ) decreased to below 90%, which was lower than the general requirement for the target area of CTV. Statistical analysis of set-up errors in all directions showed that there was significant difference in dosimetric changes ( F=34. 182, 12. 877, 16. 443, 9. 846, 46. 829, 10. 122, 57. 931, P <0. 05) in all directions except the B direction of left breast set-up errors (P>0. 05). Between breast conserving surgery and modified radical mastectomy, there was little effect on target movement. Through correlation analysis, it was found that the volume of CTV in the target area of breast cancer patients was linearly related to the errors caused by the movement of B, C and B directions of left breast and right breast(F=5. 733, 18. 496, 6. 630, P<0. 05). Conclusions In postoperative radiotherapy for breast cancer, the errors perpendicular to the section of breast should be paid special attention to whether left or right breast. When the error of this direction exceeds 3 mm, CTV is obviously less than V50 below 83. 85%. The effect of set-up error on the dose of CTV was not related to the operation mode of breast cancer and there was no obvious correlation with the volume of the target area.
5.Effects of Different Posterior Tibial Slopes in Unicompartmental Knee Arthroplasty on the Wear and Function of Prosthesis
Kunneng WU ; Gaiping ZHAO ; Dongqing LIU ; Shengqi HANG ; Peng LIANG ; Pengxiang LI ; Tong MA ; Yihui TU
Journal of Medical Biomechanics 2021;36(4):E618-E624
Objective To establish the three-dimensional (3D) finite element model of unicompartmental knee arthroplasty (UKA) with 3° and 7° posterior tibial slope at different knee flexion angles, and to study biomechanical properties and prosthetic wear of the knee joints with two types of posterior tibia slope and their effects on knee function. Methods Combining CT and MRI images of human knee joints with the 3rd-generation Oxford prosthesis, the finite element UKA model with 3° and 7° posterior tibia slope were established. The 1 kN load was applied to center point of the medial and lateral condyles of the femur to simulate the standing load of human body. The maximum stresses and distributions of the prosthesis and articular cartilage at different knee flexion angles were analyzed. ResultsThe maximum stress of the meniscus liner with 3° posterior tibia slope at 0°, 30°, 60°, 90°, 120° knee flexion angles increased by 28.06%, 68.99%, 19.45%, 21.06% and 53.38%, the distribution area was concentrated from the side of the meniscus liner to the central area, and the stress concentration was obvious at 120° knee flexion. The maximum stress of prosthesis with 3° posterior tibia slope was greater than that with 7 ° posterior tibia slope. The expansion of stress concentration area would cause wear and loosening of the prosthesis, contact stress and concentration area of the articular cartilage would subsequently increase with posterior tibia slope increasing, and stress concentration would be more obvious at high knee flexion angles. Conclusions Tibial prosthesis has the higher stress and greater wear under the condition of 3° posterior tibia slope than 7° posterior tibia slope. The research findings provide theoretical basis for the UKA design in clinic.