1.Research and Application of Scalp Surface Laplacian Technique
Rui-Xin LUO ; Si-Ying GUO ; Xin-Yi LI ; Yu-He ZHAO ; Chun-Hou ZHENG ; Min-Peng XU ; Dong MING
Progress in Biochemistry and Biophysics 2025;52(2):425-438
Electroencephalogram (EEG) is a non-invasive, high temporal-resolution technique for monitoring brain activity. However, affected by the volume conduction effect, EEG has a low spatial resolution and is difficult to locate brain neuronal activity precisely. The surface Laplacian (SL) technique obtains the Laplacian EEG (LEEG) by estimating the second-order spatial derivative of the scalp potential. LEEG can reflect the radial current activity under the scalp, with positive values indicating current flow from the brain to the scalp (“source”) and negative values indicating current flow from the scalp to the brain (“sink”). It attenuates signals from volume conduction, effectively improving the spatial resolution of EEG, and is expected to contribute to breakthroughs in neural engineering. This paper provides a systematic overview of the principles and development of SL technology. Currently, there are two implementation paths for SL technology: current source density algorithms (CSD) and concentric ring electrodes (CRE). CSD performs the Laplace transform of the EEG signals acquired by conventional disc electrodes to indirectly estimate the LEEG. It can be mainly classified into local methods, global methods, and realistic Laplacian methods. The global method is the most commonly used approach in CSD, which can achieve more accurate estimation compared with the local method, and it does not require additional imaging equipment compared with the realistic Laplacian method. CRE employs new concentric ring electrodes instead of the traditional disc electrodes, and measures the LEEG directly by differential acquisition of the multi-ring signals. Depending on the structure, it can be divided into bipolar CRE, quasi-bipolar CRE, tripolar CRE, and multi-pole CRE. The tripolar CRE is widely used due to its optimal detection performance. While ensuring the quality of signal acquisition, the complexity of its preamplifier is relatively acceptable. Here, this paper introduces the study of the SL technique in resting rhythms, visual-related potentials, movement-related potentials, and sensorimotor rhythms. These studies demonstrate that SL technology can improve signal quality and enhance signal characteristics, confirming its potential applications in neuroscientific research, disease diagnosis, visual pathway detection, and brain-computer interfaces. CSD is frequently utilized in applications such as neuroscientific research and disease detection, where high-precision estimation of LEEG is required. And CRE tends to be used in brain-computer interfaces, that have stringent requirements for real-time data processing. Finally, this paper summarizes the strengths and weaknesses of SL technology and envisages its future development. SL technology boasts advantages such as reference independence, high spatial resolution, high temporal resolution, enhanced source connectivity analysis, and noise suppression. However, it also has shortcomings that can be further improved. Theoretically, simulation experiments should be conducted to investigate the theoretical characteristics of SL technology. For CSD methods, the algorithm needs to be optimized to improve the precision of LEEG estimation, reduce dependence on the number of channels, and decrease computational complexity and time consumption. For CRE methods, the electrodes need to be designed with appropriate structures and sizes, and the low-noise, high common-mode rejection ratio preamplifier should be developed. We hope that this paper can promote the in-depth research and wide application of SL technology.
2.Predicting Clinically Significant Prostate Cancer Using Urine Metabolomics via Liquid Chromatography Mass Spectrometry
Chung-Hsin CHEN ; Hsiang-Po HUANG ; Kai-Hsiung CHANG ; Ming-Shyue LEE ; Cheng-Fan LEE ; Chih-Yu LIN ; Yuan Chi LIN ; William J. HUANG ; Chun-Hou LIAO ; Chih-Chin YU ; Shiu-Dong CHUNG ; Yao-Chou TSAI ; Chia-Chang WU ; Chen-Hsun HO ; Pei-Wen HSIAO ; Yeong-Shiau PU ;
The World Journal of Men's Health 2025;43(2):376-386
Purpose:
Biomarkers predicting clinically significant prostate cancer (sPC) before biopsy are currently lacking. This study aimed to develop a non-invasive urine test to predict sPC in at-risk men using urinary metabolomic profiles.
Materials and Methods:
Urine samples from 934 at-risk subjects and 268 treatment-naïve PC patients were subjected to liquid chromatography/mass spectrophotometry (LC-MS)-based metabolomics profiling using both C18 and hydrophilic interaction liquid chromatography (HILIC) column analyses. Four models were constructed (training cohort [n=647]) and validated (validation cohort [n=344]) for different purposes. Model I differentiates PC from benign cases. Models II, III, and a Gleason score model (model GS) predict sPC that is defined as National Comprehensive Cancer Network (NCCN)-categorized favorable-intermediate risk group or higher (Model II), unfavorable-intermediate risk group or higher (Model III), and GS ≥7 PC (model GS), respectively. The metabolomic panels and predicting models were constructed using logistic regression and Akaike information criterion.
Results:
The best metabolomic panels from the HILIC column include 25, 27, 28 and 26 metabolites in Models I, II, III, and GS, respectively, with area under the curve (AUC) values ranging between 0.82 and 0.91 in the training cohort and between 0.77 and 0.86 in the validation cohort. The combination of the metabolomic panels and five baseline clinical factors that include serum prostate-specific antigen, age, family history of PC, previously negative biopsy, and abnormal digital rectal examination results significantly increased AUCs (range 0.88–0.91). At 90% sensitivity (validation cohort), 33%, 34%, 41%, and 36% of unnecessary biopsies were avoided in Models I, II, III, and GS, respectively. The above results were successfully validated using LC-MS with the C18 column.
Conclusions
Urinary metabolomic profiles with baseline clinical factors may accurately predict sPC in men with elevated risk before biopsy.
3.Predicting Clinically Significant Prostate Cancer Using Urine Metabolomics via Liquid Chromatography Mass Spectrometry
Chung-Hsin CHEN ; Hsiang-Po HUANG ; Kai-Hsiung CHANG ; Ming-Shyue LEE ; Cheng-Fan LEE ; Chih-Yu LIN ; Yuan Chi LIN ; William J. HUANG ; Chun-Hou LIAO ; Chih-Chin YU ; Shiu-Dong CHUNG ; Yao-Chou TSAI ; Chia-Chang WU ; Chen-Hsun HO ; Pei-Wen HSIAO ; Yeong-Shiau PU ;
The World Journal of Men's Health 2025;43(2):376-386
Purpose:
Biomarkers predicting clinically significant prostate cancer (sPC) before biopsy are currently lacking. This study aimed to develop a non-invasive urine test to predict sPC in at-risk men using urinary metabolomic profiles.
Materials and Methods:
Urine samples from 934 at-risk subjects and 268 treatment-naïve PC patients were subjected to liquid chromatography/mass spectrophotometry (LC-MS)-based metabolomics profiling using both C18 and hydrophilic interaction liquid chromatography (HILIC) column analyses. Four models were constructed (training cohort [n=647]) and validated (validation cohort [n=344]) for different purposes. Model I differentiates PC from benign cases. Models II, III, and a Gleason score model (model GS) predict sPC that is defined as National Comprehensive Cancer Network (NCCN)-categorized favorable-intermediate risk group or higher (Model II), unfavorable-intermediate risk group or higher (Model III), and GS ≥7 PC (model GS), respectively. The metabolomic panels and predicting models were constructed using logistic regression and Akaike information criterion.
Results:
The best metabolomic panels from the HILIC column include 25, 27, 28 and 26 metabolites in Models I, II, III, and GS, respectively, with area under the curve (AUC) values ranging between 0.82 and 0.91 in the training cohort and between 0.77 and 0.86 in the validation cohort. The combination of the metabolomic panels and five baseline clinical factors that include serum prostate-specific antigen, age, family history of PC, previously negative biopsy, and abnormal digital rectal examination results significantly increased AUCs (range 0.88–0.91). At 90% sensitivity (validation cohort), 33%, 34%, 41%, and 36% of unnecessary biopsies were avoided in Models I, II, III, and GS, respectively. The above results were successfully validated using LC-MS with the C18 column.
Conclusions
Urinary metabolomic profiles with baseline clinical factors may accurately predict sPC in men with elevated risk before biopsy.
4.Mechanism of Quanduzhong Capsules in treating knee osteoarthritis from perspective of spatial heterogeneity.
Zhao-Chen MA ; Zi-Qing XIAO ; Chu ZHANG ; Yu-Dong LIU ; Ming-Zhu XU ; Xiao-Feng LI ; Zhi-Ping WU ; Wei-Jie LI ; Yi-Xin YANG ; Na LIN ; Yan-Qiong ZHANG
China Journal of Chinese Materia Medica 2025;50(8):2209-2216
This study aims to systematically characterize the targeted effects of Quanduzhong Capsules on cartilage lesions in knee osteoarthritis by integrating spatial transcriptomics data mining and animal experiments validation, thereby elucidating the related molecular mechanisms. A knee osteoarthritis model was established using Sprague-Dawley(SD) rats, via a modified Hulth method. Hematoxylin and eosin(HE) staining was employed to detect knee osteoarthritis-associated pathological changes in knee cartilage. Candidate targets of Quanduzhong Capsules were collected from the HIT 2.0 database, followed by bioinformatics analysis of spatial transcriptomics datasets(GSE254844) from cartilage tissues in clinical knee osteoarthritis patients to identify spatially specific disease genes. Furthermore, a "formula candidate targets-spatially specific genes in cartilage lesions" interaction network was constructed to explore the effects and major mechanisms of Quanduzhong Capsules in distinct cartilage regions. Experimental validation was conducted through immunohistochemistry using animal-derived biospecimens. The results indicated that Quanduzhong Capsules effectively inhibited the degenerative changes in the cartilage of affected joints in rats, which was associated with the regulation of Quanduzhong Capsules on the thioredoxin-interacting protein(TXNIP)-NOD-like receptor family pyrin domain containing 3(NLRP3)-bone morphogenetic protein receptor type 2(BMPR2)-fibronectin 1(FN1)-matrix metallopeptidase 2(MMP2) signal axis in the articular cartilage surface and superficial zones, subsequently inhibiting cartilage matrix degradation leading to oxidative stress and inflammatory diffusion. In summary, this study clarifies the spatially specific targeted effects and protective mechanisms of Quanduzhong Capsules within pathological cartilage regions in knee osteoarthritis, providing theoretical and experimental support for the clinical application of this drug in the targeted therapy on the inflamed cartilage.
Animals
;
Osteoarthritis, Knee/metabolism*
;
Drugs, Chinese Herbal/administration & dosage*
;
Rats, Sprague-Dawley
;
Rats
;
Male
;
Humans
;
Capsules
;
Female
;
Disease Models, Animal
5.Expert consensus on evaluation index system construction for new traditional Chinese medicine(TCM) from TCM clinical practice in medical institutions.
Li LIU ; Lei ZHANG ; Wei-An YUAN ; Zhong-Qi YANG ; Jun-Hua ZHANG ; Bao-He WANG ; Si-Yuan HU ; Zu-Guang YE ; Ling HAN ; Yue-Hua ZHOU ; Zi-Feng YANG ; Rui GAO ; Ming YANG ; Ting WANG ; Jie-Lai XIA ; Shi-Shan YU ; Xiao-Hui FAN ; Hua HUA ; Jia HE ; Yin LU ; Zhong WANG ; Jin-Hui DOU ; Geng LI ; Yu DONG ; Hao YU ; Li-Ping QU ; Jian-Yuan TANG
China Journal of Chinese Materia Medica 2025;50(12):3474-3482
Medical institutions, with their clinical practice foundation and abundant human use experience data, have become important carriers for the inheritance and innovation of traditional Chinese medicine(TCM) and the "cradles" of the preparation of new TCM. To effectively promote the transformation of new TCM originating from the TCM clinical practice in medical institutions and establish an effective evaluation index system for the transformation of new TCM conforming to the characteristics of TCM, consensus experts adopted the literature research, questionnaire survey, Delphi method, etc. By focusing on the policy and technical evaluation of new TCM originating from the TCM clinical practice in medical institutions, a comprehensive evaluation from the dimensions of drug safety, efficacy, feasibility, and characteristic advantages was conducted, thus forming a comprehensive evaluation system with four primary indicators and 37 secondary indicators. The expert consensus reached aims to encourage medical institutions at all levels to continuously improve the high-quality research and development and transformation of new TCM originating from the TCM clinical practice in medical institutions and targeted at clinical needs, so as to provide a decision-making basis for the preparation, selection, cultivation, and transformation of new TCM for medical institutions, improve the development efficiency of new TCM, and precisely respond to the public medication needs.
Medicine, Chinese Traditional/standards*
;
Humans
;
Consensus
;
Drugs, Chinese Herbal/therapeutic use*
;
Surveys and Questionnaires
6.Forty years of construction and innovative development of scientific regulation system of traditional Chinese medicine in China.
Jun-Ning ZHAO ; Zhi-Shu TANG ; Hua HUA ; Rong SHAO ; Jiang-Yong YU ; Chang-Ming YANG ; Shuang-Fei CAI ; Quan-Mei SUN ; Dong-Ying LI
China Journal of Chinese Materia Medica 2025;50(13):3489-3505
Since the promulgation of the first Drug Administration Law of the People's Republic of China 40 years ago in 1984, China has undergone four main stages in the traditional Chinese medicine(TCM) regulation: the initial establishment of TCM regulation rules(1984-1997), the formation of a modern TCM regulatory system(1998-2014), the reform of the review and approval system for new TCM drugs(2015-2018), and the construction of a scientific regulation system for TCM(2019-2024). Over the past five years, a series of milestone achievements of TCM regulation in China have been achieved in the six aspects, including its strategic objectives and the establishment of a science-based regulatory system, the reform of the review and approval system for new TCM drugs, the optimization and improvement of the TCM standard system and its formation mechanism, comprehensive enhancement of regulatory capabilities for TCM safety, international harmonization of TCM regulation and its role in promoting innovation. Looking ahead, centered on advancing TCMRS to establish a sound regulatory framework tailored to the unique characteristics of TCM, TCM regulation will evolve into new reform patterns, advancing and extending across eight critical fronts, including the legal framework and policy architecture, the review and approval system for new TCM drugs, the quality standard and management system of TCM, the comprehensive quality & safety regulation and traceability system, the research and transformation system for TCMRS, AI-driven innovations in TCM regulation, the coordination between high-quality industrial development and high-level regulation, and the leadership in international cooperation and regulatory harmonization. In this way, a unique path for the development of modern TCM regulation with Chinese characteristics will be pioneered.
Humans
;
China
;
Drugs, Chinese Herbal/standards*
;
History, 20th Century
;
History, 21st Century
;
Medicine, Chinese Traditional/trends*
7.Research progress on the characteristics of magnetoencephalography signals in depression.
Zhiyuan CHEN ; Yongzhi HUANG ; Haiqing YU ; Chunyan CAO ; Minpeng XU ; Dong MING
Journal of Biomedical Engineering 2025;42(1):189-196
Depression, a mental health disorder, has emerged as one of the significant challenges in the global public health domain. Investigating the pathogenesis of depression and accurately assessing the symptomatic changes are fundamental to formulating effective clinical diagnosis and treatment strategies. Utilizing non-invasive brain imaging technologies such as functional magnetic resonance imaging and scalp electroencephalography, existing studies have confirmed that the onset of depression is closely associated with abnormal neural activities and altered functional connectivity in multiple brain regions. Magnetoencephalography, unaffected by tissue conductivity and skull thickness, boasts high spatial resolution and signal-to-noise ratio, offering unique advantages and significant value in revealing the abnormal brain mechanisms and neural characteristics of depression. This review, starting from the rhythmic characteristics, nonlinear dynamic features, and connectivity characteristics of magnetoencephalography in depression patients, revisits the research progress on magnetoencephalography features related to depression, discusses current issues and future development trends, and provides insights for the study of pathophysiological mechanisms, as well as for clinical diagnosis and treatment of depression.
Humans
;
Magnetoencephalography/methods*
;
Brain/physiopathology*
;
Depression/diagnosis*
;
Electroencephalography
;
Magnetic Resonance Imaging
8.Early clinical outcomes of 3D-printed individualised customised prostheses in hip revision combined severe bone defect.
Hong-Ping WANG ; Ming-You WANG ; Xiao-Qin YANG ; Zhuo-Dong TANG ; Xun-Zhou SONG ; Yu-Ping LAN
China Journal of Orthopaedics and Traumatology 2025;38(2):163-169
OBJECTIVE:
To explore the early clinical outcomes of 3D printed individualised customised prostheses for in hip revision in patients with combined severe bone defects.
METHODS:
Twenty-two patients from January 2021 to May 2023 underwent hip revision using 3D printed personalised customised prostheses were retrospective analyzed, including 10 males and 12 females, age 28 to 78 with a mean of (58.9±12.8) years old. All of patients were combined with severe bone defects (Parprosky type Ⅲ). Among of them, 9 patients had periprosthetic infections and 13 patients had aseptic prosthesis loosening. All patients were treated with a 3D printed personalised prosthesis protocol, patients with the periprosthetic infection received a second stage revision after infection control. The operation time, preoperative waiting time, intraoperative and postoperative complications were recorded, and the clinical efficacy were evaluated at the final follow-up using the visual analogue scale (VAS) for pain, the Harris hip score.
RESULTS:
One patient was lost to follow-up and the remaining 21 patients were followed up for 10 to 15 with a mean of (12.91±1.44) months after surgery. All patients completed surgery as planned, with an operative time of 135 to 390 with a mean of (165.4±39.3) minutes and a preoperative waiting time of 7 to 16 with a mean of (10.5±3.3) days. Regarding patient complications:one patient had a severe intraoperative periprosthetic femoral fracture due to the combination of severe osteoporosis; one patient had an intraoperative greater trochanteric femur fracture. At the latest follow-up, all patients had good position of the custom-made prosthesis and no loosening of the prosthesis;all patients had good wound healing and no local redness or swelling. The total Harris score at the final follow-up (85.86±7.04) was significantly improved compared to the preoperative (44.86±2.36), P<0.001. The VAS at the last follow-up (2.19±0.87) was significantly improved compared with preoperative (7.41±0.96), P<0.001.
CONCLUSION
The clinical efficacy of 3D-printed personalised customised prosthesis in combined severe bone defect hip revision is satisfactory, but due to the increased preoperative waiting time of the patients and certain risks, certain indications should be mastered when applying in the clinic.
Humans
;
Male
;
Female
;
Printing, Three-Dimensional
;
Middle Aged
;
Aged
;
Adult
;
Retrospective Studies
;
Hip Prosthesis
;
Arthroplasty, Replacement, Hip
;
Reoperation
;
Prosthesis Design
;
Treatment Outcome
9.Comparison of application and efficacy of domestic HURWA and imported Smith & Nephew Cori robots in total knee arthroplasty.
Ming-You WANG ; Zhuo-Dong TANG ; Yu-Ping LAN ; Heng XIAO ; Ming-Li WANG ; Xun-Zhou SONG ; Hong-Ping WANG
China Journal of Orthopaedics and Traumatology 2025;38(10):1027-1036
OBJECTIVE:
Investigation on the clinical application of HURWA robot and Smith & Nephew Cori robot in total knee arthroplasty(TKA).
METHODS:
A retrospective analysis was performed on 84 patients with knee osteoarthritis who underwent robotic-assisted TKA (RATKA) between June 2023 and March 2025. According to the different robotic systems used, the patients were divided into the domestic HUARUN robotic-assisted total knee arthroplasty group (HRATKA group) and the Smith & Nephew Cori robotic-assisted total knee arthroplasty group (CRATKA group). There were 42 patients in the HRATKA group, including 16 males and 26 females; the age ranged from 56 to 73 years old, with an average of (64.70±8.30) years old;the body mass index (BMI) was (25.10±2.30) kg·m-2;21 cases were on the right side and 21 cases on the left side;in terms of Kellgren-Lawrence(K-L) classification, there were 15 cases of Grade Ⅲ and 27 cases of Grade Ⅳ;the disease duration ranged from 3 to 25 years, with an average of (15.5±7.5) years. The CRATKA group also included 42 patients, with 14 males and 28 females;the age ranged from 58 to 74 years old, with an average of (65.60±7.50) years old;the BMI was (24.50±2.70) kg·m-2; 20 cases were on the right side and 22 cases on the left side;regarding K-L classification, there were 11 cases of Grade Ⅲ and 31 cases of Grade Ⅳ;the disease duration ranged from 2 to 26 years, with an average of (16.5±8.8) years. Collect general data of all patients, including age, gender, height, weight, surgical site, K-L classification, incision length, and operation time. To evaluate prosthesis position, compare the frontal tibia component (FTC) angle, lateral femoral component (LFC) angle, lateral tibia component (LTC) angle, and frontal femoral component angle between the two groups of patients after surgery. Measure the deviation of the hip-knee-ankle (HKA) angle to assess lower limb alignment. Additionally, compare the following indicators between the two groups:Knee Society Score (KSS), Visual Analogue Scale (VAS) for pain, knee range of motion (ROM), hemoglobin (HB) level, hematocrit (HCT) level, complication rate, and in-hospital satisfaction.
RESULTS:
All patients successfully completed the surgery as scheduled, and all were followed up after the operation. The follow-up period ranged from 5 to 17 months with an average of (11.2±6.1) months. There were 4 cases of venous thrombosis in the HRATKA group and 3 cases in the CRATKA group;each group had 2 cases of wound exudation. No mechanical-related complications, pulmonary embolism, or other severe complications occurred. Comparison of the incision length and hospital stay between the HRATKA group and the CRATKA group showed no statistically significant difference (P>0.05). The operation time in the HRATKA group was (96.80±7.10) minutes, which was longer than that in the CRATKA group (90.10±8.80) minutes, and the difference was statistically significant (P<0.05). In the HRATKA group, the HKA angle was (178.93±1.11) degree, the FFC angle was (89.00±0.91)°, and the LFC angle was (7.31±2.17) degree;the corresponding values in the CRATKA group were (178.05±1.34)°, (87.88±1.74)°, and (10.60±2.84) degree respectively. The differences in these three indicators between the two groups were all statistically significant (P<0.05). However, there were no statistically significant differences in the FTC angle or LTC angle between the two groups (P>0.05). There was also no statistically significant difference in the total perioperative blood loss between the two groups (P>0.05). At 3 days after surgery, the VAS score for movement in the HRATKA group (5.95±1.45) points was higher than that in the CRATKA group (4.50±0.97) points, with a statistically significant difference (P<0.05);at 90 days after surgery, there was no statistically significant difference in the movement VAS score between the two groups (P>0.05). Additionally, no statistically significant differences were observed between the two groups in the KSS, ROM at 3 and 90 days after surgery, or satisfaction degree during hospitalization (all P>0.05).
CONCLUSION
The domestic HURWA robot demonstrates excellent performance in osteotomy efficiency and lower limb alignment recovery. The Smith & Nephew Cori robot has a significant advantage in soft tissue assessment and joint stability optimization. Both robotic systems offer high-quality surgical treatments that significantly improve short-term knee function.
Humans
;
Male
;
Female
;
Arthroplasty, Replacement, Knee/instrumentation*
;
Aged
;
Middle Aged
;
Retrospective Studies
;
Robotic Surgical Procedures/methods*
;
Osteoarthritis, Knee/surgery*
10.Protocol for development of Guideline for Interventions on Cervical Spine Health.
Jing LI ; Guang-Qi LU ; Ming-Hui ZHUANG ; Xin-Yue SUN ; Ya-Kun LIU ; Ming-Ming MA ; Li-Guo ZHU ; Zhong-Shi LI ; Wei CHEN ; Ji-Ge DONG ; Le-Wei ZHANG ; Jie YU
China Journal of Orthopaedics and Traumatology 2025;38(10):1083-1088
Cervical spine health issues not only seriously affect patients' quality of life but also impose a heavy burden on the social healthcare system. Existing guidelines lack sufficient clinical guidance on lifestyle and work habits, such as exercise, posture, daily routine, and diet, making it difficult to meet practical needs. To address this, relying on the China Association of Chinese Medicine, Wangjing Hospital of China Academy of Chinese Medical Sciences took the lead and joined hands with more than ten institutions to form a multidisciplinary guideline development group. For the first time, the group developed the Guidelines for Cervical Spine Health Intervention based on evidence-based medicine methods, strictly following the standardized procedures outlined in the World Health Organization Handbook for Guideline Development and the Guiding Principles for the Formulation/Revision of Clinical Practice Guidelines in China (2022 Edition). This proposal systematically explains the methods and steps for developing the guideline, aiming to make the guideline development process scientific, standardized, and transparent.
Humans
;
Practice Guidelines as Topic/standards*
;
Cervical Vertebrae
;
China

Result Analysis
Print
Save
E-mail