1.Effects of polylactic acid-glycolic acid copolymer/lysine-grafted graphene oxide nanoparticle composite scaffolds on osteogenic differentiation of MC3T3 cells
Shuangqi YU ; Fan DING ; Song WAN ; Wei CHEN ; Xuejun ZHANG ; Dong CHEN ; Qiang LI ; Zuoli LIN
Chinese Journal of Tissue Engineering Research 2025;29(4):707-712
BACKGROUND:How to effectively promote bone regeneration and bone reconstruction after bone injury has always been a key issue in clinical bone repair research.The use of biological and degradable materials loaded with bioactive factors to treat bone defects has excellent application prospects in bone repair. OBJECTIVE:To investigate the effect of polylactic acid-glycolic acid copolymer(PLGA)composite scaffold modified by lysine-grafted graphene oxide nanoparticles(LGA-g-GO)on osteogenic differentiation and new bone formation. METHODS:PLGA was dissolved in dichloromethane and PLGA scaffold was prepared by solvent evaporation method.PLGA/GO composite scaffolds were prepared by dispersing graphene oxide uniformly in PLGA solution.LGA-g-GO nanoparticles were prepared by chemical grafting method,and the PLGA/LGA-g-GO composite scaffolds were constructed by blending LGA-g-GO nanoparticles at different mass ratios(1%,2%,and 3%)with PLGA.The micromorphology,hydrophilicity,and protein adsorption capacity of scaffolds of five groups were characterized.MC3T3 cells were inoculated on the surface of scaffolds of five groups to detect cell proliferation and osteogenic differentiation. RESULTS AND CONCLUSION:(1)The surface of PLGA scaffolds was smooth and flat under scanning electron microscope,while the surface of the other four scaffolds was rough.The surface roughness of the composite scaffolds increased with the increase of the addition of LGA-g-GO nanoparticles.The water contact angle of PLGA/LGA-g-GO(3%)composite scaffolds was lower than that of the other four groups(P<0.05).The protein adsorption capacity of PLGA/LGA-g-GO(1%,2%,and 3%)composite scaffolds was stronger than PLGA and PLGA/GO scaffolds(P<0.05).(2)CCK-8 assay showed that PLGA/LGA-g-GO(2%,3%)composite scaffold could promote the proliferation of MC3T3 cells.Alkaline phosphatase staining and alizarin red staining showed that the cell alkaline phosphatase activity in PLGA/LGA-g-GO(2%,3%)group was higher than that in the other three groups(P<0.05).The calcium deposition in the PLGA/GO and PLGA/LGA-g-GO(1%,2%,and 3%)groups was higher than that in the PLGA group(P<0.05).(3)In summary,PLGA/LGA-g-GO composite scaffold can promote the proliferation and osteogenic differentiation of osteoblasts,and is conducive to bone regeneration and bone reconstruction after bone injury.
2.Application of "balance-shaped sternal elevation device" in the subxiphoid uniportal video-assisted thoracoscopic surgery for anterior mediastinal masses resection
Jinlan ZHAO ; Weiyang CHEN ; Chunmei HE ; Yu XIONG ; Lei WANG ; Jie LI ; Lin LIN ; Yushang YANG ; Lin MA ; Longqi CHEN ; Dong TIAN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(03):308-312
Objective To introduce an innovative technique, the "balance-shaped sternal elevation device" and its application in the subxiphoid uniportal video-assisted thoracoscopic surgery (VATS) for anterior mediastinal masses resection. Methods Patients who underwent single-port thoracoscopic assisted anterior mediastinal tumor resection through the xiphoid process at the Department of Thoracic Surgery, West China Hospital, Sichuan University from May to June 2024 were included, and their clinical data were analyzed. Results A total of 7 patients were included, with 3 males and 4 females, aged 28-72 years. The diameter of the tumor was 1.9-17.0 cm. The operation time was 62-308 min, intraoperative blood loss was 5-100 mL, postoperative chest drainage tube retention time was 0-9 days, pain score on the 7th day after surgery was 0-2 points, and postoperative hospital stay was 3-12 days. All patients underwent successful and complete resection of the masses and thymus, with favorable postoperative recovery. Conclusion The "balance-shaped sternal elevation device" effectively expands the retrosternal space, providing surgeons with satisfactory surgical views and operating space. This technique significantly enhances the efficacy and safety of minimally invasive surgery for anterior mediastinal masses, reduces trauma and postoperative pain, and accelerates patient recovery, demonstrating important clinical significance and application value.
3.Analysis on Quality Standard of Sennae Folium(Cassia angustifolia) Dispensing Granules Based on Standard Decoctions
Jinxin LI ; Xue DONG ; Shuai DUAN ; Guiyun CAO ; Jinghua ZHANG ; Yongfu LUAN ; Yongqiang LIN ; Xiaodi DONG ; Zhaoqing MENG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(9):192-200
ObjectiveTo establish the quality standards for Sennae Folium(Cassia angustifolia) dispensing granules based on standard decoctions. MethodsHigh performance liquid chromatography(HPLC) specific chromatograms were established for 15 batches of Sennae Folium(C. angustifolia) standard decoctions and 10 of Sennae Folium(C. angustifolia) dispensing granules from different manufacturers, and the similarity evaluation, hierarchical cluster analysis(HCA) and principal component analysis(PCA) were performed. Linear calibration with two reference substances(LCTRS) and quantitative analysis of multi-components by single-marker(QAMS) were established for the common peaks in the specific chromatograms to determine the contents of main components in the decoction pieces, standard decoctions and dispensing granules, and to calculate their transfer rates from decoction pieces to standard decoctions and dispensing granules. ResultsThe similarities of specific chromatograms of 15 batches of Sennae Folium(C. angustifolia) standard decoctions and 10 batches of Sennae Folium(C. angustifolia) dispensing granules were all greater than 0.95, and a total of 8 characteristic peaks were calibrated, and five of them were identified, including kaempferol-3,7-O-diglucoside, apigenin-6,8-di-C-glucoside, quercetin-3-O-gentianoside, sennoside B and sennoside A. HCA and PCA results showed that there were certain differences in the composition of different batches of standard decoctions, but no clustering was observed in the production area. As the standard decoctions, the extract rate of 15 batches of samples was 26.54%-45.38%, the contents of kaempferol-3,7-O-diglucoside, apigenin-6,8-di-C-glucoside, quercetin-3-O-gentianoside, sennoside B and sennoside A were 12.16-19.26, 2.57-4.94, 3.27-5.11, 6.75-11.39, 4.69-7.79 mg·g-1, and their transfer rates from decoction pieces to standard decoctions were 45.41%-79.02%, 29.12%-55.07%, 40.52%-67.90%, 24.72%-49.12%, 27.54%-49.34%, respectively. The extract rates of Sennae Folium(C. angustifolia) dispensing granules(C8-C10) were 38.10%-39.50%, the transfer rates of the above five components from decoction pieces to dispensing granules were 72.85%-73.58%, 53.43%-53.94%, 40.19%-40.74%, 24.62%-25.00%, 28.65%-29.11%, respectively, which were generally consistent with the transfer rates from decoction pieces to standard decoctions. ConclusionCompared with the relative retention time method, LCTRS has higher prediction accuracy and is more suitable for chromatographic columns. The established quality control standard of Sennae Folium(C. angustifolia) dispensing granules based on standard decoction is reasonable and reliable, and all indicators of samples from different manufacturers are within the range specified based on the standard decoction, which can provide reference for the quality control and process research of this dispensing granules.
4.Analysis on Quality Standard of Hedyotis Herba Dispensing Granules Based on Standard Decoction
Jinghua ZHANG ; Nana WU ; Yanan LYU ; Guiyun CAO ; Jiacheng XU ; Yongqiang LIN ; Xiaodi DONG ; Jinxin LI ; Zhaoqing MENG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(10):210-217
ObjectiveTo establish the specific chromatogram and quantitative analysis of multi-components by single-marker(QAMS) based on linear calibration using two reference substances(LCTRS), explore the consistency between Hedyotis Herba dispensing granules and standard decoction, and evaluate the quality of the dispensing granules. MethodsHigh performance liquid chromatography(HPLC) specific chromatogram was established based on 15 batches of Hedyotis Herba standard decoction and 10 batches of the dispensing granules, and LCTRS was used to locate chromatographic peaks. The actual retention times of 7 characteristic peaks in the specific chromatogram was measured on 24 different types of C18 columns, taking deacetyl asperulosidic acid and asperulosidic acid as the dual standard compounds, the retention times of the other 5 characteristic peaks were predicted and validated. Based on this, QAMS was developed to determine the contents of four components(deacetyl asperulosidic acid, deacetyl asperulosidic acid methyl ester, asperulosidic acid, and p-coumaric acid). Then, the relative correction factors of deacetyl asperulosidic acid, deacetyl asperulosidic acid methyl ester and p-coumaric acid were calculated using the reference peak of asperulosidic acid in the dual standard compounds, and each component was quantified accordingly. Finally, the consistency between the dispensing granules and standard decoction was assessed by taking extract rate of the standard decoction, consistency of the specific chromatograms, contents and transfer rates of the indicator components as indexes, and the quality of the dispensing granules was evaluated. ResultsThere were 7 common peaks in the characteristic chromatogram of samples of Hedyotis Herba standard decoction and the dispensing granules, and four of them were identified by reference standards, namely deacetyl asperulosidic acid(peak 1), deacetyl asperulosidic acid methyl ester(peak 3), asperulosidic acid(peak 6) and p-coumaric acid(peak 7). The similarity between the dispensing granules and the standard decoction was >0.9. The absolute deviation in the predicted retention time for each component by LCTRS was lower than that of the relative retention time method. The extract rate of the 15 batches of Hedyotis Herba standard decoction ranged from 7.89% to 14.60%, the contents of deacetyl asperulosidic acid, deacetyl asperulosidic acid methyl ester, asperulosidic acid and p-coumaric acid were 6.62-19.70, 3.83-17.99, 1.57-6.69, 1.62-4.52 mg·g-1, and the transfer rates of these components from decoction pieces to the standard decoction were 22.89%-39.60%, 34.03%-62.24%, 24.25%-43.70%, and 40.58%-73.71%, respectively. The extract rate, index component contents and transfer rates from decoction pieces to the three batches of Hedyotis Herba dispensing granules(P1-P3), produced by manufacturer A, were similar to those of the standard decoction prepared from the same batch of decoction pieces, and all fell within the specified range. The contents of the 4 indicator components in 7 batches of the dispensing granules(P4-P10) from manufacturers B-E were all within the range of the content converted from the standard decoction based on the quantity of the dispensing granules. ConclusionThe established specific chromatogram and QAMS based on LCTRS are reasonable and reliable. Based on the evaluation indicators of standard decoction yield, consistency of specific chromatograms, contents and transfer rates of the four index components, the 10 batches of Hedyotis Herba dispensing granules from various manufacturers have exhibited good consistency with the standard decoction, indicating that the current production process is relatively reasonable.
5.Quality Evaluation of Chuanxiong Rhizoma Dispensing Granules Based on HPLC Specific Chromatogram and Two Reference Substances for Determination of Multiple Components
Jinxin LI ; Xue DONG ; Shuai DUAN ; Guiyun CAO ; Jinghua ZHANG ; Yongfu LUAN ; Yongqiang LIN ; Xiaodi DONG ; Zhaoqing MENG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(11):246-253
ObjectiveTo establish the specific chromatogram of Chuanxiong Rhizoma dispensing granules(CRdg), and to evaluate its quality by chemometrics and two reference substances for determination of multiple components(TRSDMC). MethodsHigh performance liquid chromatography(HPLC) specific chromatograms were established using 13 batches of CRdg from 7 manufacturers, and preliminary quality evaluation was performed by similarity evaluation and chemometrics analysis. Eight characteristic peaks in the specific chromatogram of CRdg were measured on 22 different types of C18 columns, and the actual retention times were recorded. Taking chlorogenic acid(peak 1) and senkyunolide A(peak 8) as double standard compounds, the retention times of the eight characteristic peaks were predicted by linear calibration using two reference substances(LCTRS), and the method was validated on three other columns of different brands. Taking chlorogenic acid as reference peak, the relative correction factor method(RCFM) was used to quantify cryptochlorogenic acid, caffeic acid, ferulic acid, senkyunolide I and senkyunolide A, and the results were compared with the external standard method(ESM). ResultsThe similarities of specific chromatograms of 13 batches of CRdg were all >0.90, and a total of 8 characteristic peaks were calibrated, and six of them were identified, including chlorogenic acid(peak 1), cryptochlorogenic acid(peak 2), caffeic acid(peak 3), ferulic acid(peak 5), senkyunolide I(peak 6) and senkyunolide A(peak 8). Through chemometric analysis, it was found that ferulic acid, chlorogenic acid, senkyunolide I and cryptochlorogenic acid were the main components causing quality difference in CRdg, and the accuracy of LCTRS in predicting the retention time of 8 characteristic peaks was superior to that of the relative retention time method(RRT). Further comparison of the results obtained from RCFM and ESM showed that there was no statistically significant difference between the two methods. ConclusionA quality evaluation method for CRdg based on HPLC specific chromatogram and TRSDMC is established, its qualitative accuracy is better than that of RRT, the quantitative accuracy is similar to that of ESM, and 4 quality-differentiated components among different manufacturers are found. This method is stable and reliable, and has reference value for the quality evaluation of other dispensing granules.
6.Construction and Validation of a Large Language Model-Based Intelligent Pre-Consultation System for Traditional Chinese Medicine
Yiqing LIU ; Ying LI ; Hongjun YANG ; Linjing PENG ; Nanxing XIAN ; Kunning LI ; Qiwei SHI ; Hengyi TIAN ; Lifeng DONG ; Lin WANG ; Yuping ZHAO
Journal of Traditional Chinese Medicine 2025;66(9):895-900
ObjectiveTo construct a large language model (LLM)-based intelligent pre-consultation system for traditional Chinese medicine (TCM) to improve efficacy of clinical practice. MethodsA TCM large language model was fine-tuned using DeepSpeed ZeRO-3 distributed training strategy based on YAYI 2-30B. A weighted undirected graph network was designed and an agent-based syndrome differentiation model was established based on relationship data extracted from TCM literature and clinical records. An agent collaboration framework was developed to integrate the TCM LLM with the syndrome differentiation model. Model performance was comprehensively evaluated by Loss function, BLEU-4, and ROUGE-L metrics, through which training convergence, text generation quality, and language understanding capability were assessed. Professional knowledge test sets were developed to evaluate system proficiency in TCM physician licensure content, TCM pharmacist licensure content, TCM symptom terminology recognition, and meridian identification. Clinical tests were conducted to compare the system with attending physicians in terms of diagnostic accuracy, consultation rounds, and consultation duration. ResultsAfter 100 000 iterations, the training loss value was gradually stabilized at about 0.7±0.08, indicating that the TCM-LLM has been trained and has good generalization ability. The TCM-LLM scored 0.38 in BLEU-4 and 0.62 in ROUGE-L, suggesting that its natural language processing ability meets the standard. We obtained 2715 symptom terms, 505 relationships between diseases and syndromes, 1011 relationships between diseases and main symptoms, and 1 303 600 relationships among different symptoms, and constructed the Agent of syndrome differentiation model. The accuracy rates in the simulated tests for TCM practitioners, licensed pharmacists of Chinese materia medica, recognition of TCM symptom terminology, and meridian recognition were 94.09%, 78.00%, 87.50%, and 68.80%, respectively. In clinical tests, the syndrome differentiation accuracy of the system reached 88.33%, with fewer consultation rounds and shorter consultation time compared to the attending physicians (P<0.01), suggesting that the system has a certain pre- consultation ability. ConclusionThe LLM-based intelligent TCM pre-diagnosis system could simulate diagnostic thinking of TCM physicians to a certain extent. After understanding the patients' natural language, it collects all the patient's symptom through guided questioning, thereby enhancing the diagnostic and treatment efficiency of physicians as well as the consultation experience of the patients.
7.Quality Evaluation of Chuanxiong Rhizoma Dispensing Granules Based on HPLC Specific Chromatogram and Two Reference Substances for Determination of Multiple Components
Jinxin LI ; Xue DONG ; Shuai DUAN ; Guiyun CAO ; Jinghua ZHANG ; Yongfu LUAN ; Yongqiang LIN ; Xiaodi DONG ; Zhaoqing MENG
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(11):246-253
ObjectiveTo establish the specific chromatogram of Chuanxiong Rhizoma dispensing granules(CRdg), and to evaluate its quality by chemometrics and two reference substances for determination of multiple components(TRSDMC). MethodsHigh performance liquid chromatography(HPLC) specific chromatograms were established using 13 batches of CRdg from 7 manufacturers, and preliminary quality evaluation was performed by similarity evaluation and chemometrics analysis. Eight characteristic peaks in the specific chromatogram of CRdg were measured on 22 different types of C18 columns, and the actual retention times were recorded. Taking chlorogenic acid(peak 1) and senkyunolide A(peak 8) as double standard compounds, the retention times of the eight characteristic peaks were predicted by linear calibration using two reference substances(LCTRS), and the method was validated on three other columns of different brands. Taking chlorogenic acid as reference peak, the relative correction factor method(RCFM) was used to quantify cryptochlorogenic acid, caffeic acid, ferulic acid, senkyunolide I and senkyunolide A, and the results were compared with the external standard method(ESM). ResultsThe similarities of specific chromatograms of 13 batches of CRdg were all >0.90, and a total of 8 characteristic peaks were calibrated, and six of them were identified, including chlorogenic acid(peak 1), cryptochlorogenic acid(peak 2), caffeic acid(peak 3), ferulic acid(peak 5), senkyunolide I(peak 6) and senkyunolide A(peak 8). Through chemometric analysis, it was found that ferulic acid, chlorogenic acid, senkyunolide I and cryptochlorogenic acid were the main components causing quality difference in CRdg, and the accuracy of LCTRS in predicting the retention time of 8 characteristic peaks was superior to that of the relative retention time method(RRT). Further comparison of the results obtained from RCFM and ESM showed that there was no statistically significant difference between the two methods. ConclusionA quality evaluation method for CRdg based on HPLC specific chromatogram and TRSDMC is established, its qualitative accuracy is better than that of RRT, the quantitative accuracy is similar to that of ESM, and 4 quality-differentiated components among different manufacturers are found. This method is stable and reliable, and has reference value for the quality evaluation of other dispensing granules.
8.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
9.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.
10.Ultrasound-guided attenuation parameter for identifying metabolic dysfunction-associated steatotic liver disease: a prospective study
Yun-Lin HUANG ; Chao SUN ; Ying WANG ; Juan CHENG ; Shi-Wen WANG ; Li WEI ; Xiu-Yun LU ; Rui CHENG ; Ming WANG ; Jian-Gao FAN ; Yi DONG
Ultrasonography 2025;44(2):134-144
Purpose:
This study assessed the performance of the ultrasound-guided attenuation parameter (UGAP) in diagnosing and grading hepatic steatosis in patients with metabolic dysfunctionassociated steatotic liver disease (MASLD). Magnetic resonance imaging proton density fat fraction (MRI-PDFF) served as the reference standard.
Methods:
Patients with hepatic steatosis were enrolled in this prospective study and underwent UGAP measurements. MRI-PDFF values of ≥5%, ≥15%, and ≥25% were used as references for the diagnosis of steatosis grades ≥S1, ≥S2, and S3, respectively. Spearman correlation coefficients and area under the receiver operating characteristic curves (AUCs) were calculated.
Results:
Between July 2023 and June 2024, the study included 88 patients (median age, 40 years; interquartile range [IQR], 36 to 46 years), of whom 54.5% (48/88) were men and 45.5% (40/88) were women. Steatosis grades exhibited the following distribution: 22.7% (20/88) had S0, 50.0% (44/88) had S1, 21.6% (19/88) had S2, and 5.7% (5/88) had S3. The success rate for UGAP measurements was 100%. The median UGAP value was 0.74 dB/cm/MHz (IQR, 0.65 to 0.82 dB/ cm/MHz), and UGAP values were positively correlated with MRI-PDFF (r=0.77, P<0.001). The AUCs of UGAP for the diagnoses of ≥S1, ≥S2, and S3 steatosis were 0.91, 0.90, and 0.88, respectively. In the subgroup analysis, 98.4% (60/61) of patients had valid controlled attenuation parameter (CAP) values. UGAP measurements were positively correlated with CAP values (r=0.65, P<0.001).
Conclusion
Using MRI-PDFF as the reference standard, UGAP demonstrates good diagnostic performance in the detection and grading of hepatic steatosis in patients with MASLD.

Result Analysis
Print
Save
E-mail