1.A Study on Hormonal Change of Lh, FSH, and Testosterone and Testicular Volumes in Pubertal Mal Children.
Heung Dong KIM ; Duk Hi KIM ; Ki Keun OH
Journal of the Korean Pediatric Society 1986;29(9):51-59
No abstract available.
Child*
;
Humans
;
Testosterone*
2.Congenital Syphilis: Radiologic Findings of Early Congenital Syphilis.
Dong Kun KIM ; Jung Bock LEE ; Ki Keun OH
Korean Journal of Dermatology 1985;23(1):39-44
A retrospective study was made of the previous medical records of 32 infants with congenital syphilis borne from mothers with untreated syphilis at Severence Hospital, Yonsei University College of Medicine during the years 1,972 through 19g3, These infants had a VDRL titer higher than 1: 8 with reactive FTA-ABS test and were also subjected to radiologic examinations. Radiologic changes and clinical features were analyzed, The following results were obtained: Of the total of 32 infants with congenital syphilis under 5 months of age, those under 1 month of age, were the most common group numbering a total of twelve. Of 32 infants with congenital syphilis, twenty-nine(91%) showed skeletal changes upon radiologic examination, Among them the different sites of bone involvernent revealed that the femur(92%) was the most commonly affected bone, followed by the humerus(88%), tibia(81%,), fibula(80%), ulna(72%), radius (68%). Among the same 29 infants a study of the presence of various abnormal bone changes showed that periostitis was the most common, being involved in 83%, the others being metaphysitis and periostitis(72%), metaphysitis(66%). 3. Among the clinicaI features presented in the 32 infants with congenital syphilis, hepatomegaly was the most common(63%,), followed by erythema with desquamation(47%), pneumonia(38%), maulopapules(34%).
Erythema
;
Fluorescent Treponemal Antibody-Absorption Test
;
Hepatomegaly
;
Humans
;
Infant
;
Medical Records
;
Mothers
;
Periostitis
;
Radius
;
Retrospective Studies
;
Syphilis
;
Syphilis, Congenital*
3.Surgical treatment of cervical tuberculosis lymphadenitis.
Jee Soo KIM ; Dong Young NOH ; Seung Keun OH
Journal of the Korean Surgical Society 1992;43(2):157-166
No abstract available.
Lymphadenitis*
;
Tuberculosis*
4.Effect of growth factors and differentiation inducer DMSO on the anaplastic thyroid carcinoma cell line, SNU-80.
Seung Keun OH ; Dong Young NOH ; Jae Gahb PARK
Journal of the Korean Cancer Association 1991;23(2):237-246
No abstract available.
Cell Line*
;
Dimethyl Sulfoxide*
;
Intercellular Signaling Peptides and Proteins*
;
Thyroid Gland*
;
Thyroid Neoplasms*
5.Recurrent carcinoma of the thyroid.
Byung In MOON ; Dong Young NOH ; Seung Keun OH
Journal of the Korean Cancer Association 1992;24(3):422-427
No abstract available.
Thyroid Gland*
6.A Clinical Study On The Occurrence Of Food Impaction.
Jae Hoon JUNG ; Sang Chun OH ; Jin Keun DONG
The Journal of Korean Academy of Prosthodontics 2000;38(1):50-58
The purpose of this study was to investigate the causes of food impaction and to explore solutions as well. For this study, 39 patients with food impaction wee selected. 77 contact areas in these patients were investigated mobility, tightness of contact area, gingival index, plaque index, attachment loss, alveolar bone loss, proximal caries, marginal ridge distance and occlusal relationships. The results were as follows ; 1. Teeth without distal support were found to be the most frequent site of food impaction (41.6%). Food impaction was found to be more frequent in the upper teeth (66.2%) than the lower teeth (33.8%). 2. Food impaction was found in tight contact cases (71.4%). Alveolar bone loss was not found in the early stage of food impaction (83.1%) 3. The distance between the marginal ridges of food impaction sites (mean=0.48mm) was shorter than that of the control group. (mean=0.77mm) (p<0.001) 4. In 18.2% of t he cases, proximal carries were found at the food impaction site. 5. Food impaction affected patient's occlusion with the following frequencies ; cusp to marginal ridge relationship (72.7%), cusp to fossa relationship (3.9%) and stepped relationship (23.4%).
Alveolar Bone Loss
;
Humans
;
Periodontal Index
;
Tooth
7.Flexure strength of acrylic resin temporary brigde by pontic design.
Sang Chun OH ; Tai Ho JIN ; Jin Keun DONG
The Journal of Korean Academy of Prosthodontics 1992;30(1):65-72
No abstract available.
Denture, Partial, Fixed*
8.Incidence and Risk Factors of Periventricular and Intraventricular Hemorrhage in Low Birth Weight Infants.
Chul LEE ; Heung Dong KIM ; Ki Keun OH ; Dong Gwan HAN
Journal of the Korean Pediatric Society 1986;29(11):19-26
No abstract available.
Hemorrhage*
;
Humans
;
Incidence*
;
Infant*
;
Infant, Low Birth Weight*
;
Infant, Newborn
;
Risk Factors*
9.A STUDY ON THE MICROSTRUCTURE OF IPS EMPRESS CERAMICS ACCORDING TO THE HEAT TREATMENT AND SPRUE TYPE.
The Journal of Korean Academy of Prosthodontics 1998;36(5):772-785
This study was undertaken to clarify the microstructure of the different IPS Empress ingots by etching and to observe the change of leucite crystal structure according to subsequent heat treatment and the crystal distribution according to sprue types(0 2.8mm, single sprue; 0 1.8mm, double sprue) by scanning electron microscopy. IPS Empress T1, O1 ingots used for staining technique, and Dentin(A2) ingots used for layering technique were selected for this study. To observe the microstructures of these ingots before pressing, the specimens were prepared in splinters(3x3x3mm) taken from the original ingots. And to estimate crystal distribution and microstructural change by sprue type and subsequent heat treatment, the specimens(3x3x3mm) were heat-pressed through the two types of sprues with different diameters and numbers, and all specimens were fired according to the recommended firing schedule. The observed surface was ground with waterproof papers(#800~#1800) on the grind polisher and was cleaned ultrasonically. All specimen were etched with 0.5% hydrofluoric acid. After etching, the surface was treated by ion sputter coating for SEM observation at an accelerating voltage of 20kV. In all specimens, the central area of ground surface was observed because there was less difference in microstructure between the peripheral area and the central area. The results were as follows ; 1. In the microstructure according to the ingot type, there was a wide difference between the staining (T1,O1) and layering(Dentin A2) ingots, but there was not a considerable difference between the T1 ingot and the O1 ingot for staining technique. 2. In all specimens, the crystal dispersion of IPS Empress ceramic using double sprue was significantly more scattered than that of IPS Empress ceramic using single sprue. The degree of scattering was strongest in the Dentin(A2) specimen and weakest in the O1 ingot. 3. In the microstructural change according to the subsequent heat treatment, all of ingots had some microcracks in the inside of the leucite crystal and the glass matrix after pressing. The inner splinters of the leucite crystal became smaller, and more microcracks occurred in the glass matrix due to increasing heat treatment times. 4. The size of leucite crystals varied from 1micrometerto 5micrometer. The mean size of mature crystals was about 5micrometer. The form of the crystal was similar to a circle when it was smaller and similar to an ellipse when it was larger.
Appointments and Schedules
;
Celiac Disease*
;
Ceramics*
;
Fires
;
Glass
;
Hot Temperature*
;
Hydrofluoric Acid
;
Microscopy, Electron, Scanning
10.A STUDY ON THE FLEXURAL STRENGH OF HEAT-PRESSED CERAMICS ACCORDING TO SPRUE DESIGNS.
The Journal of Korean Academy of Prosthodontics 1997;35(1):130-143
A heat-pressed technique(IPS-Empress, Ivoclar) has been described to construct single unit crown, inlay/onlay and veneers using a partially pre-cerammed and pre-colored glass-leucite ingot that has the greateast strength by the combination of heat-pressed procedure through the small-diameter sprue and heat treatment procedure. The purpose of this study was to evaluate the flexure strength of a heat-pressed ceramic material(IPS-Empress) without simulated firing treatments according to pontic designs. Two groups of 9 disks(1.4mm thick, 14mm in diameter) each using two types of sprues with different diameters(phi2.8, phi1.8) and numbers were prepared. The specimens were mounted in the testing jig. The flexural strengths were determined, by means of the bi-axial bending test, by loading the center of disk to failure using a universal testing machine(Zwick 145141, Zwick, Germany) at a cross-head speed of 1.0 mm/min. The means flexural strength value of one group using a sprue with phi2.8 was 140.4+/-8.0 Mpa. That of the other group using two sprues with phi1.8 was 151.8+/-10.3 Mpa. After analysis, results showed that there was a statistical difference between groups(t=2.33m p<0.05). No clnical implications were drawn from these data because of absence of simulated firing treatment.
Celiac Disease*
;
Ceramics*
;
Crowns
;
Denture, Partial, Fixed
;
Fires
;
Hot Temperature