1.Analysis factors influencing left ventricular thrombus in patients with non-ischemic heart failure
Zhiyan WANG ; Hao ZHANG ; Wenjie LI ; Chang HUA ; Yangyang TANG ; Xinru LIU ; Yuling XIONG ; Qiang LYU ; Jianzeng DONG ; Xin DU
Chinese Journal of Cardiology 2024;52(10):1155-1161
		                        		
		                        			
		                        			Objective:To explore the influencing factors of left ventricular thrombus (LVT) in patients with non-ischemic heart failure (NIHF) and to construct a nomogram prediction model for NIHF patients with LVT.Methods:This study was a case-control study. A total of 2 592 patients with NIHF hospitalized in Beijing Anzhen Hospital affiliated to Capital Medical University from January 2018 to July 2022 were selected. Fifty-one patients with LVT identified by echocardiography and cardiac magnetic resonance were classified into LVT group. One hundred and sixty patients were selected as the non-LVT group using a 1∶3 propensity score matching based on age and gender. Multivariate logistic regression analysis was used to explore the influencing factors of LVT in patients with NIHF. A nomogram prediction model was constructed, and the area under (AUC) the receiver operating characteristic (ROC) curve was calculated to evaluate the predictive effect of the model.Results:A total of 211 patients were enrolled, with a median age of 40 years old and 160 males (76%). Compared with non-LVT group, LVT group had lower systolic blood pressure ((112±20) mmHg vs. (120±19) mmHg; 1 mmHg=0.133 kPa), lower left ventricular ejection fraction (LVEF; (27±12)% vs. (39±14)% ), lower proportion of patients with history of hypertension (28% (14/51) vs. 44% (70/160)) and atrial fibrillation (8% (4/51)vs.39% (62/160)), higher proportion of patients with New York Heart Association functional class Ⅲ to Ⅳ (class Ⅲ: 59% (30/51) vs. 41% (66/160); class Ⅳ: 28% (14/51) vs. 19% (31/160)), and larger left ventricular end-systolic diameter (LVESD; (56±14) mm vs. (50±15) mm). The levels of hemoglobin ((152±23) g/L vs. (142±30) g/L), D-dimer (508 (300, 1 105) μg/L vs. 158 (68, 379) μg/L), and N-terminal pro-brain natriuretic peptide (3 429 (2 462, 4 734) ng/L vs. 1 288 (422, 2 544) ng/L) were higher in LVT group than in non-LVT group ( P all<0.05). LVT group had a higher proportion of patients using beta-blockers (92% (47/51) vs. 78% (124/160)), angiotensin-converting enzyme inhibitors or angiotensin receptor blockers or angiotensin receptor neprilysin inhibitors (88% (45/51) vs. 72% (115/160)), and anticoagulant drugs (98% (50/51) vs. 32% (51/160)) than non-LVT group (all P <0.05). Multivariate logistic regression showed that reduced LVEF ( OR=1.08, 95% CI 1.02-1.15, P=0.008), decreased LVESD ( OR=1.07, 95% CI 1.01-1.12, P=0.013), and increased D-dimer levels ( OR=5.40, 95% CI 1.98-14.74, P=0.001) were independent influencing factors for LVT in patients with NIHF. The ROC curve showed that the AUC of the nomogram for predicting LVT in patients with NIHF was 0.793 (95% CI 0.710-0.876, P<0.001). Conclusion:Reduced LVEF, decreased LVESD, and elevated D-dimer are associated with LVT in NIHF patients. The predictive model developed based on the above indicators has certain value in predicting LVT in NIHF patients.
		                        		
		                        		
		                        		
		                        	
2.An Exploratory Study on the Effects of Interatrial Shunt for Patients With Heart Failure With Reduced Ejection Fraction
Sanshuai CHANG ; Wenhui WU ; Xinmin LIU ; Zhengming JIANG ; Yutong KE ; Qiang LYU ; Xin DU ; Jianzeng DONG ; Guangyuan SONG
Chinese Circulation Journal 2024;39(10):989-996
		                        		
		                        			
		                        			Objectives:To explore the effects of interatrial shunt on cardiac function and clinical prognosis of patients with heart failure with reduced ejection fraction(HFrEF). Methods:This study was a prospective single-arm study.From December 2021 to December 2022,15 consecutive patients with HFrEF from Beijing Anzhen Hospital were enrolled in this study.Interatrial shunt was performed with a D-Shant atrial shunt device.Right heart catheterization was performed before and immediately after device implantation,pulmonary capillary wedge pressure(PCWP),mean right atrial pressure(RAP),interatrial gradient pressure,mean pulmonary artery pressure,total pulmonary resistance(TPR),pulmonary vascular resistance(PVR),cardiac index(CI),and pulmonary/systemic blood flow ratio(Qp/Qs)were measured.Patients were followed-up for 12 months after procedure,changes in cardiac structure and function were evaluated by echocardiography.NYHA classification,6-minute walking distance(6MWD),and Kansas City cardiomyopathy questionnaire(KCCQ)were observed.All-cause mortality and rehospitalization for heart failure served as clinical endpoints. Results:Interatrial shunt procedure was successful in all patients.Compared with preoperative value,PCWP,interatrial gradient pressure,mean pulmonary artery pressure,and TPR were significantly decreased,while Qp/Qs was significantly increased immediately after procedure(all P<0.01).There were no significant changes in RAP,PVR,and CI post procedure(all P>0.05).There were no significant differences in shunt size,shunt velocity,and shunt pressure difference between postoperative immediately and at 12-months follow-up(all P>0.05).At 12 months,left ventricular ejection fraction was significantly higher than baseline level(P<0.05),and there were no significant changes in right atrial diameter and right ventricular fractional area change(both P>0.05).Compared with preoperative status,NYHA classification was improved,KCCQ score was increased,and the number of patients with 6MWD>450 m was increased at 12 months(all P<0.05).N-terminal pro-B-type natriuretic peptide value was significantly decreased at 12 months(P<0.05).No patient died during the 12-months follow-up period,and there were no device-related adverse events.Two patients experienced hospital readmission for heart failure. Conclusions:Implantation of interatrial shunt device could effectively improve hemodynamic parameters in patients with HFrEF and is related to significantly improved cardiac function at 12-months follow-up.
		                        		
		                        		
		                        		
		                        	
3.Application and Prospects of Polygenic Risk Score (PRS) in Genetic Disease Research: a Review of Data Analysis Methods
Shu-Xin HE ; Chang-Shun YU ; Xiao-Dong JIA ; Jian-Chun CHEN ; Ke-Qiang YAN
Progress in Biochemistry and Biophysics 2024;51(8):1797-1808
		                        		
		                        			
		                        			Lower-cost genotyping technology has promoted the generation of large genetic datasets with the evolving next-generation sequencing technology. The emergence of genome-wide association studies (GWAS) has facilitated researchers’ understanding of common complex diseases. GWAS refers to finding the sequence variations present in the human genome and screening out disease-related single nucleotide polymorphisms (SNPs). These SNPs are considered as the basis for assessing the stability of complex diseases. However, a single variation is not sufficient to assess an individual’s risk of disease. Polygenic risk score (PRS) is an emerging genetic data analysis method for quantitatively estimating an individual’s genetic risk for complex diseases by comprehensively considering multiple genetic variation sites. A single-value estimate of an individual’s genetic risk for a certain phenotype can be calculated as the cumulative impact of multiple genetic variants by building a PRS model. The finally expected risk score is weighted by the strength and direction of association of each SNP with the phenotype based on the number of alleles carried by each SNP. With the continuous development of various PRS calculation methods and the constant accumulation of genomic data, PRS has received widespread attention in the field of genetics. So far, quite a few studies at home and abroad have shown that PRS is valuable in risk prediction of different types of human traits or complex diseases, and its effectiveness has been further verified in clinical applications. At present, many studies have established PRS models based on GWAS summary statistics to quantify the genetic risk of susceptibility loci and clinical characteristics on diseases such as lung cancer, breast cancer, coronary heart disease, diabetes and Alzheimer’s disease. The disease-susceptible populations can be recognized through comparing the relative risk and absolute risk of the disease in different risk groups according to the population risk stratification results. Additionally, individual-level genotype data and omics data can also be used as data sources for PRS analysis research, especially the latter can dynamically reflect the short-term or long-term effects of environmental factors on human gene expression, and has potential application value in building early warning models to assess health risks. Since the calculation of PRS involves a large amount of genomic data analysis, there are big differences in the methods for data selection, model building and validation. Different PRS construction methods and software have different performances in disease risk prediction, and even the performance of same algorithm varies across diseases. It is worth noting that the PRS model often needs to be re-evaluated and verified for different groups of people, because PRS is affected by race and region. This review combines currently published PRS-related research and algorithms to describe the basic principles of PRS, compares their construction and verification methods, and discusses their applications and prospects. As a powerful genetic risk assessment tool, PRS has great potential in analyzing the genetic code of complex diseases and achieving precise diagnosis and personalized treatment. 
		                        		
		                        		
		                        		
		                        	
4.Study on evaluation method of circular small shadow profusion in chest CT reconstruction images of pneumoconiosis
Chang LIU ; Ming YANG ; Qiang WANG ; Jing BAI ; Zheng DUAN ; Huitai DONG
Chinese Journal of Industrial Hygiene and Occupational Diseases 2024;42(5):359-369
		                        		
		                        			
		                        			Objective:To select chest CT image patterns for the diagnosis of pneumoconiosis and establish a method for determining the profusion of circular small shadows in chest CT.Methods:In April 2021, 66 cases of occupational pneumoconiosis patients with digital radiography (DR) chest radiographs and chest CT imaging data with circular small shadow as the main manifestations were selected as the study objects. 1.5 mm and 5 mm chest CT axial images, 1 mm and 5 mm chest CT coronal multi-plane recombination (MPR) images, and 5 mm chest CT coronal maximum intensity projection (MIP) images were used to observe the different characteristics of pneumoconiosis patients, and were compared and analyzed with DR chest radiographs to establish the experimental chest CT standards. The consistency of the profusion results between the experimental chest CT standards and GBZ 70-2015 Diagnosis of Occupational Pneumoconiosis was verified.Results:All the 66 objects were male, including 33 cases of stage Ⅰ pneumoconiosis, 17 cases of stage Ⅱ pneumoconiosis and 16 cases of stage Ⅲ pneumoconiosis. By observing five chest CT images of 66 objects, we found that chest CT images of different modes could clearly display and identify abnormal images such as small circular shadow, large shadow, small shadow aggregation, honeycomb glass shadow, flake glass shadow, uniform low-profusion glass shadow, mesh glass shadow, cable shadow, linear shadow, subpleural spinous shadow, subpleural nodules, various kinds of emphysema and lung texture distortion and fracture. Small shadow aggregation was usually accompanied by the appearance of large shadow. The vascular shadows in 5 mm CT images had good ductility, and small nodules were easy to distinguish. The coronal MIP image of 5 mm chest CT used edge enhancement technology, which was prone to small shadow fusion and fibrotic shadow fusion. The coronal MPR image of 5 mm chest CT was highly consistent with the DR chest radiographs in terms of the integrity of film reading. GBZ 70-2015 standard was used to compare the profusion of DR chest radiographs and 5 mm chest CT coronal MPR images of 66 objects, and the consistency test Kappa=0.64. GBZ 70-2015 standard and experimental chest CT standard were used to compare the profusion results of DR chest radiographs and 5 mm chest CT coronal MPR images of 66 objects, respectively, and the consistency test Kappa=0.80, with high consistency.Conclusion:5 mm coronal MPR image is suitable for chest CT imaging in the diagnosis of pneumoconiosis. Following the selection path and method of GBZ 70-2015 profusion criterion, the established experimental chest CT standard in determining the profusion of small circular shadows in 5 mm coronal MPR images of chest CT with pneumoconiosis has a high consistency with GBZ 70-2015 standard.
		                        		
		                        		
		                        		
		                        	
5.Study on evaluation method of circular small shadow profusion in chest CT reconstruction images of pneumoconiosis
Chang LIU ; Ming YANG ; Qiang WANG ; Jing BAI ; Zheng DUAN ; Huitai DONG
Chinese Journal of Industrial Hygiene and Occupational Diseases 2024;42(5):359-369
		                        		
		                        			
		                        			Objective:To select chest CT image patterns for the diagnosis of pneumoconiosis and establish a method for determining the profusion of circular small shadows in chest CT.Methods:In April 2021, 66 cases of occupational pneumoconiosis patients with digital radiography (DR) chest radiographs and chest CT imaging data with circular small shadow as the main manifestations were selected as the study objects. 1.5 mm and 5 mm chest CT axial images, 1 mm and 5 mm chest CT coronal multi-plane recombination (MPR) images, and 5 mm chest CT coronal maximum intensity projection (MIP) images were used to observe the different characteristics of pneumoconiosis patients, and were compared and analyzed with DR chest radiographs to establish the experimental chest CT standards. The consistency of the profusion results between the experimental chest CT standards and GBZ 70-2015 Diagnosis of Occupational Pneumoconiosis was verified.Results:All the 66 objects were male, including 33 cases of stage Ⅰ pneumoconiosis, 17 cases of stage Ⅱ pneumoconiosis and 16 cases of stage Ⅲ pneumoconiosis. By observing five chest CT images of 66 objects, we found that chest CT images of different modes could clearly display and identify abnormal images such as small circular shadow, large shadow, small shadow aggregation, honeycomb glass shadow, flake glass shadow, uniform low-profusion glass shadow, mesh glass shadow, cable shadow, linear shadow, subpleural spinous shadow, subpleural nodules, various kinds of emphysema and lung texture distortion and fracture. Small shadow aggregation was usually accompanied by the appearance of large shadow. The vascular shadows in 5 mm CT images had good ductility, and small nodules were easy to distinguish. The coronal MIP image of 5 mm chest CT used edge enhancement technology, which was prone to small shadow fusion and fibrotic shadow fusion. The coronal MPR image of 5 mm chest CT was highly consistent with the DR chest radiographs in terms of the integrity of film reading. GBZ 70-2015 standard was used to compare the profusion of DR chest radiographs and 5 mm chest CT coronal MPR images of 66 objects, and the consistency test Kappa=0.64. GBZ 70-2015 standard and experimental chest CT standard were used to compare the profusion results of DR chest radiographs and 5 mm chest CT coronal MPR images of 66 objects, respectively, and the consistency test Kappa=0.80, with high consistency.Conclusion:5 mm coronal MPR image is suitable for chest CT imaging in the diagnosis of pneumoconiosis. Following the selection path and method of GBZ 70-2015 profusion criterion, the established experimental chest CT standard in determining the profusion of small circular shadows in 5 mm coronal MPR images of chest CT with pneumoconiosis has a high consistency with GBZ 70-2015 standard.
		                        		
		                        		
		                        		
		                        	
6.A single-center study on the safety and effectiveness of a novel non-implant interatrial shunt device
San-Shuai CHANG ; Xin-Min LIU ; Zheng-Ming JIANG ; Yu-Tong KE ; Qian ZHANG ; Qiang LÜ ; Xin DU ; Jian-Zeng DONG ; Guang-Yuan SONG
Chinese Journal of Interventional Cardiology 2024;32(8):425-433
		                        		
		                        			
		                        			Objective To preliminarily evaluate the safety and effectiveness of a novel non-implantable atrial shunt device based on radiofrequency ablation for the treatment of chronic heart failure(CHF).Methods This was a prospective single-arm study.From January 2023 to December 2023,five eligible CHF patients were consecutively enrolled at Beijing Anzhen Hospital,Capital Medical University,and underwent inter-atrial shunt using Shenzhen Betterway atrial shunt device.Pulmonary capillary wedge pressure(PCWP),right atrial pressure(RAP),pulmonary artery pressure(PAP),total pulmonary resistance(TPR),pulmonary vascular resistance(PVR),and pulmonary/systemic blood flow ratio(Qp/Qs)were measured using right heart catheterization before and immediately after procedure.Patients were followed up for 90 days,and echocardiography,right heart catheterization,and cardiac functional indicators were evaluated.The primary endpoint was procedural success.Secondary endpoints included clinical success,echocardiographic changes,6-minute walk distance(6MWD)changes,New York Heart Association(NYHA)class changes,Kansas city cardiomyopathy questionnaire(KCCQ)score changes,and amino-terminal probrain natriuretic peptide(NT-proBNP)level changes at 90 days.The safety endpoint was major cardiovascular and cerebrovascular adverse events and device-related adverse events.Results All five patients successfully achieved left-to-right atrial shunt.Compared with baseline,PCWP decreased significantly immediately after procedure in all five patients,with a procedural success rate of 100%.There were no significant changes in RAP,PAP,TPR,and PVR before and immediately after procedure.After 90 days follow-up,four patients had persistent left-to-right atrial shunt,and PCWP was significantly lower than baseline,with a clinical success rate of 80%.Compared with baseline,LVEF increased,left ventricular end-diastolic diameter decreased,and tricuspid annular plane systolic excursion and right ventricular fractional area change were not impaired in all five patients at 90 days.KCCQ scores and 6MWT improved,NT-proBNP decreased,and NYHA class did not change significantly.There were no deaths,rehospitalizations for heart failure,stroke-related adverse events,or device-related adverse events during the follow-up.Conclusions The novel non-implantable atrial shunt catheter can safely and effectively improve hemodynamic,echocardiographic,and cardiac functional indicators in patients with heart failure.However,larger-scale clinical studies are still needed to validate its long-term clinical effectiveness.
		                        		
		                        		
		                        		
		                        	
7.HbA1c comparison and diagnostic efficacy analysis of multi center different glycosylated hemoglobin detection systems.
Ping LI ; Ying WU ; Yan XIE ; Feng CHEN ; Shao qiang CHEN ; Yun Hao LI ; Qing Qing LU ; Jing LI ; Yong Wei LI ; Dong Xu PEI ; Ya Jun CHEN ; Hui CHEN ; Yan LI ; Wei WANG ; Hai WANG ; He Tao YU ; Zhu BA ; De CHENG ; Le Ping NING ; Chang Liang LUO ; Xiao Song QIN ; Jin ZHANG ; Ning WU ; Hui Jun XIE ; Jina Hua PAN ; Jian SHUI ; Jian WANG ; Jun Ping YANG ; Xing Hui LIU ; Feng Xia XU ; Lei YANG ; Li Yi HU ; Qun ZHANG ; Biao LI ; Qing Lin LIU ; Man ZHANG ; Shou Jun SHEN ; Min Min JIANG ; Yong WU ; Jin Wei HU ; Shuang Quan LIU ; Da Yong GU ; Xiao Bing XIE
Chinese Journal of Preventive Medicine 2023;57(7):1047-1058
		                        		
		                        			
		                        			Objective: Compare and analyze the results of the domestic Lanyi AH600 glycated hemoglobin analyzer and other different detection systems to understand the comparability of the detection results of different detectors, and establish the best cut point of Lanyi AH600 determination of haemoglobin A1c (HbA1c) in the diagnosis of diabetes. Methods: Multi center cohort study was adopted. The clinical laboratory departments of 18 medical institutions independently collected test samples from their respective hospitals from March to April 2022, and independently completed comparative analysis of the evaluated instrument (Lanyi AH600) and the reference instrument HbA1c. The reference instruments include four different brands of glycosylated hemoglobin meters, including Arkray, Bio-Rad, DOSOH, and Huizhong. Scatter plot was used to calculate the correlation between the results of different detection systems, and the regression equation was calculated. The consistency analysis between the results of different detection systems was evaluated by Bland Altman method. Consistency judgment principles: (1) When the 95% limits of agreement (95% LoA) of the measurement difference was within 0.4% HbA1c and the measurement score was≥80 points, the comparison consistency was good; (2) When the measurement difference of 95% LoA exceeded 0.4% HbA1c, and the measurement score was≥80 points, the comparison consistency was relatively good; (3) The measurement score was less than 80 points, the comparison consistency was poor. The difference between the results of different detection systems was tested by paired sample T test or Wilcoxon paired sign rank sum test; The best cut-off point of diabetes was analyzed by receiver operating characteristic curve (ROC). Results: The correlation coefficient R2 of results between Lanyi AH600 and the reference instrument in 16 hospitals is≥0.99; The Bland Altman consistency analysis showed that the difference of 95% LoA in Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180) was -0.486%-0.325%, and the measurement score was 94.6 points (473/500); The difference of 95% LoA in the Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant II) was -0.727%-0.612%, and the measurement score was 89.8 points; The difference of 95% LoA in the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT) was -0.231%-0.461%, and the measurement score was 96.6 points; The difference of 95% LoA in the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT) was -0.469%-0.479%, and the measurement score was 91.9 points. The other 14 hospitals, Lanyi AH600, were compared with 4 reference instrument brands, the difference of 95% LoA was less than 0.4% HbA1c, and the scores were all greater than 95 points. The results of paired sample T test or Wilcoxon paired sign rank sum test showed that there was no statistically significant difference between Lanyi AH600 and the reference instrument Arkray HA8180 (Z=1.665,P=0.096), with no statistical difference. The mean difference between the measured values of the two instruments was 0.004%. The comparison data of Lanyi AH600 and the reference instrument of all other institutions had significant differences (all P<0.001), however, it was necessary to consider whether it was within the clinical acceptable range in combination with the results of the Bland-Altman consistency analysis. The ROC curve of HbA1c detected by Lanyi AH600 in 985 patients with diabetes and 3 423 patients with non-diabetes was analyzed, the area under curve (AUC) was 0.877, the standard error was 0.007, and the 95% confidence interval 95%CI was (0.864, 0.891), which was statistically significant (P<0.001). The maximum value of Youden index was 0.634, and the corresponding HbA1c cut point was 6.235%. The sensitivity and specificity of diabetes diagnosis were 76.2% and 87.2%, respectively. Conclusion: Among the hospitals and instruments currently included in this study, among these four hospitals included Nanjing Maternity and Child Health Care Hospital in Jiangsu Province (reference instrument: Arkray HA8180), Tibetan Traditional Medical Hospital of TAR (reference instrument: Bio-Rad Variant Ⅱ), the People's Hospital of Chongqing Liang Jiang New Area (reference instrument: Huizhong MQ-2000PT), and the Taihe Hospital of traditional Chinese Medicine in Anhui Province (reference instrument: Huizhong MQ-2000PT), the comparison between Lanyi AH600 and the reference instruments showed relatively good consistency, while the other 14 hospitals involved four different brands of reference instruments: Arkray, Bio-Rad, DOSOH, and Huizhong, Lanyi AH600 had good consistency with its comparison. The best cut point of the domestic Lanyi AH600 for detecting HbA1c in the diagnosis of diabetes is 6.235%.
		                        		
		                        		
		                        		
		                        			Pregnancy
		                        			;
		                        		
		                        			Child
		                        			;
		                        		
		                        			Humans
		                        			;
		                        		
		                        			Female
		                        			;
		                        		
		                        			Glycated Hemoglobin
		                        			;
		                        		
		                        			Cohort Studies
		                        			;
		                        		
		                        			Diabetes Mellitus/diagnosis*
		                        			;
		                        		
		                        			Sensitivity and Specificity
		                        			;
		                        		
		                        			ROC Curve
		                        			
		                        		
		                        	
8.Overcoming chemoresistance in non-angiogenic colorectal cancer by metformin via inhibiting endothelial apoptosis and vascular immaturity
Guang-Yue LI ; Shu-Jing ZHANG ; Dong XUE ; Yue-Qi FENG ; Yan LI ; Xun HUANG ; Qiang CUI ; Bo WANG ; Jun FENG ; Tao BAO ; Pei-Jun LIU ; Shao-Ying LU ; Ji-Chang WANG
Journal of Pharmaceutical Analysis 2023;13(3):262-275
		                        		
		                        			
		                        			The development of chemoresistance which results in a poor prognosis often renders current treatments for colorectal cancer(CRC).In this study,we identified reduced microvessel density(MVD)and vascular immaturity resulting from endothelial apoptosis as therapeutic targets for overcoming chemoresistance.We focused on the effect of metformin on MVD,vascular maturity,and endothelial apoptosis of CRCs with a non-angiogenic phenotype,and further investigated its effect in overcoming chemoresistance.In situ transplanted cancer models were established to compare MVD,endothelial apoptosis and vascular maturity,and function in tumors from metformin-and vehicle-treated mice.An in vitro co-culture system was used to observe the effects of metformin on tumor cell-induced endothelial apoptosis.Transcriptome sequencing was performed for genetic screening.Non-angiogenic CRC developed inde-pendently of angiogenesis and was characterized by vascular leakage,immaturity,reduced MVD,and non-hypoxia.This phenomenon had also been observed in human CRC.Furthermore,non-angiogenic CRCs showed a worse response to chemotherapeutic drugs in vivo than in vitro.By suppressing endo-thelial apoptosis,metformin sensitized non-angiogenic CRCs to chemo-drugs via elevation of MVD and improvement of vascular maturity.Further results showed that endothelial apoptosis was induced by tumor cells via activation of caspase signaling,which was abrogated by metformin administration.These findings provide pre-clinical evidence for the involvement of endothelial apoptosis and subsequent vascular immaturity in the chemoresistance of non-angiogenic CRC.By suppressing endothelial apoptosis,metformin restores vascular maturity and function and sensitizes CRC to chemotherapeutic drugs via a vascular mechanism.
		                        		
		                        		
		                        		
		                        	
            
Result Analysis
Print
Save
E-mail