1.Dihydroflavones in Rhododendron concinnum.
Lei ZHAO ; Dinghui WU ; Xiaohui YU ; Yan ZHANG
China Journal of Chinese Materia Medica 2010;35(6):722-724
OBJECTIVETo study the chemical constituents of the whole plant of Rhododendron concinnum.
METHODThe compounds were isolated and purified by chromatography on silica gel and polyamide. Their structures were identified on the basis of spectroscopic data (MS,1H-NMR and 13C-NMR) and chemical evidence.
RESULTFive dihydroflavones were isolated and identified as (2R)-farrerol-7-O-glucopyranoside (1), (2R,3R)-(-)-dihydroquercetin-3-O-beta-D-xylopyranoside(2), (2S,3S)-(-)-dihydroquercetin-3-O-beta-D-glucopyranoside(3), eriodictyol-7-O-beta-D-glucopyranoside (4) , (2R, 3R)-(+)-dihydroquercetin (5).
CONCLUSIONExcept compound 5, others were firstly isolated from the genus Rhododendron.
Antineoplastic Agents, Phytogenic ; pharmacology ; Cell Line, Tumor ; Cell Survival ; drug effects ; Chromatography, High Pressure Liquid ; methods ; Chromones ; chemistry ; Humans ; Inhibitory Concentration 50 ; Magnetic Resonance Spectroscopy ; Quercetin ; analogs & derivatives ; analysis ; pharmacology ; Rhododendron ; chemistry ; Silica Gel ; Silicon Dioxide ; analysis ; pharmacology
2.Hydrogen sulfide ameliorates high glucose-induced endothelial cell senes-cence by suppressing oxidative stress
Zhiming SONG ; Min WANG ; Yong LIU ; Baoshun HAO ; Haiming NIU ; Dinghui LIU ; Shujie YU ; Bin ZHOU ; Lin WU ; Xianguan YU ; Yesheng LING ; Pei PENG ; Jieming ZHU ; Lin CHEN ; Xiaoxian QIAN
Chinese Journal of Pathophysiology 2014;(8):1345-1350
AIM: To explore the effect of hydrogen sulfide on the senescence of human umbilical vein endothe -lial cells (HUVECs) induced by high glucose.METHODS: Senescence model was established by treating HUVECs with33 mmol/L glucose for 48 h.The parameters were detected to demonstrate the effect of hydrogen sulfide on senescence andthe mechanism involved was also investigated .RESULTS: In the cells treated with high glucose, the proliferation was attenuatedwith a higher number of senescence -associated β-galactosidase (SA-β-Gal) positive cells, and plasminogen activatorinhibitor 1 (PAI-1) protein expression, malondialdehyde (MDA) production and NF-κB p65 activity were increasedsignificantly, but the expression of superoxide dismutase 1 (SOD1) was decreased.However, the cell number and SOD1expression were increased, and the number of SA-β-Gal positive cells, PAI-1 protein expression, MDA production and theactivity of NF-κB p65 were decreased after sodium hydrosulfide (100 and 200 μmol/L) treatment.CONCLUSION: Exogenoushydrogen sulfide prevents HUVECs against high glucose -induced senescence by suppressing oxidative stress and NF -κB p65 activity.
3.Development of Biliary Contrast Agents Remote Pushing Device.
Haoyang ZHU ; Dinghui DONG ; Yu LUO ; Fenggang REN ; Jing ZHANG ; Wenjun TAN ; Aihua SHI ; Liangshuo HU ; Rongqian WU ; Yi LYU
Chinese Journal of Medical Instrumentation 2018;42(1):11-13
A biliary contrast agents pushing device, including a syringe pushing system and a remote controller is introduced. The syringe pushing system comprises an injector card slot, a support platform and an injection bolus fader. A 20 mL syringe can be fitted on the syringe pushing system and kept with the ground about 30 degree. This system can perform air bubble pumping back and contrast agents bolus injection as well as speed adjustment. Remote controller is an infrared remote control which can start and stop the syringe pushing system. With this device, the remote controlled cholangiography technology can be achieved, which can not only protect doctors from X-ray radiation but also improve the traditional T-tube cholangiography and the contrast effect, reduce postoperative complications in patients as well. The application of this device will improve the current diagnosis and treatment system, the device will benefit the majority of doctors and patients.
Contrast Media
;
administration & dosage
;
Humans
;
Injections
;
Postoperative Complications
;
Syringes
4.Research Progress of Magnetically Anchored Abdominal Video System.
Yang WU ; Ailiyaer AIKESHANJIANG ; Hui FENG ; Yifan CAI ; Lingzi ZHANG ; Yuhang ZHANG ; Hongfan DING ; Shanpei WANG ; Dinghui DONG ; Yi L ; Tao MA
Chinese Journal of Medical Instrumentation 2022;46(5):523-528
Magnetic anchoring technology provides a new development opportunity for current minimally invasive surgery. The magnetic anchoring abdominal video system based on this technology can effectively improve the operability and minimally invasiveness of single-port laparoscopic surgery. The development history of magnetically anchored abdominal video system was reviewed, and the design features and deficiencies of various types of magnetically anchored video devices were compared and analyzed. The evolution characteristics of the magnetic anchored video system are explained from minimally invasive and intelligent perspectives, and the challenges and opportunities of magnetic anchored video system are summarized and prospected.
Abdomen
;
Laparoscopy
;
Magnetics
;
Minimally Invasive Surgical Procedures
5.Development of Motion Unit of Simulated Intelligent Endotracheal Suctioning Robot.
Wenjun TAN ; Cunyi SHEN ; Yu LUO ; Haoyang ZHU ; Tao MA ; Dinghui DONG ; Aihua SHI ; Zhao XUE ; Rongqian WU ; Y LYU
Chinese Journal of Medical Instrumentation 2019;43(1):17-20
A motion unit for sucking robot with a stable motion, convenient operation and process simulation is introduced. The key parameters and process data of the sucking operation were obtained from the clinical work, which provided the basis for the design of the sucking robot motion unit. According to the points of sucking action, robotic thumb, forefinger and metacarpophalangeal joints were used to grip the suction tube, and the servo and arm structure were used to simulate the motion of the wrist and elbow to complete the rotation and push of the sputum suction tube. The feasibility is verified through the advanced sputum suction training model. The movement unit is stable in movement, and can smoothly complete the clamping, feeding, back off protection and rotating tube removal of the sputum suction tube, so as to achieve effective sputum suction.
Catheterization
;
Intubation, Intratracheal
;
Robotics
;
Suction