1.Evaluation of Vitros 950 for Quantitative Analysis of Digoxin and Theophylline.
Jong Phil KIM ; Min KIM ; Myoung YUN ; Chang Jae LEE ; Jong Hee SHIN ; Soon Pal SUH ; Dong Wook RYANG
Korean Journal of Clinical Pathology 1999;19(4):409-413
BACKGROUND: We evaluated the Vitros 950 (Johnson & Johnson Clinical Diagnostics, Inc., NY, USA) in the measurement of digoxin and theophylline levels and compared its results to those of the TDxFLx II (Abbott Laboratories, IL, USA) used for therapeutic drug monitoring (TDM) world-widely in order to assess the utility of the Vitros 950 as a TDM instrument. METHODS: From June 1997 to August 1997, 125 and 135 candidates for TDM were randomly chosen to measure digoxin and theophylline, respectively, using the Vitros 950 and TDxFLx II. The relationship between its results and those of TDxFLx II were determined. The within-run and between-run precisions of the Vitros 950 were determined using two controls (Vitros Performance Verifier I and II; J & J Clinical Diagnostics, Inc., NY, USA). The high-concentration control (Vitros Performance Verifier II) was diluted in Vitros 7% BSA to 5 dilutions. And linearity for quantitative analysis of digoxin and theophylline were determined. RESULTS: The coefficients of variation (CV) for the within-run of the Vitro 950 were 0.8% - 4.4%. And the CV for between-run precision of the Vitro 950 were 1.7% - 12.3%. The linearity of digoxin and theophylline were relatively good. The correlations (r) of digoxin and theophylline levels with those determined by the Abbott TDxFLx II were 0.95 and 0.93, respectively (P <0.001). CONCLUSIONS: The recently developed dry slide method of the Vitros 950 proves to good precision and linearity for quantitative analysis of digoxin and theophylline. Its results correlate well with those of the TDxFLx II. The Vitros 950 does not require an elaborate preparatory protocol for the sample, and is easy to use and maintain.So it is considered a highly feasible instrument for stat test.
Digoxin*
;
Drug Monitoring
;
Theophylline*
2.A Case of Chronic Atrial Tachycardia Managed with Digoxin and Reserpine.
Young Hee KIM ; Young Ju CHOI ; Sang Il RHEE ; Sang Woo KIM
Journal of the Korean Pediatric Society 1984;27(1):79-83
No abstract available.
Digoxin*
;
Reserpine*
;
Tachycardia*
3.Differential Effects of Digoxin on Imiquimod-Induced Psoriasis-Like Skin Inflammation on the Ear and Back.
Marie MADSEN ; Tanja Xenia PEDERSEN ; Lars Bo NIELSEN ; Claus JOHANSEN ; Peter Riis HANSEN
Annals of Dermatology 2018;30(4):485-488
No abstract available.
Digoxin*
;
Ear*
;
Inflammation*
;
Skin*
4.Initial Experiences of the Interpretative Report System in Therapeutic Drug Monitoring Services.
Korean Journal of Clinical Pathology 1997;17(5):711-717
BACKGROUND: Therapeutic drug monitoring (TDM) has been shown to be effective in minimizing the risk for toxicity and maximizing the efficacy of the drugs. The application of pharmacokinetics principles to indiviualization and optimization of dosage is necessary. We evolved interpretative report system of digoxin determination in a view of individual's pharmacokinetics. The alto of the present study is to validate the effectiveness of the interpretative report system in digoxin therapeutic monitoring service. METHODS: We reviewed 125 inpatients of two groups. 4 group, before interpretative reporting, had 86 inpatients from February 1996 to March 1996. B group included 39 inpatients from September 1996 to October 1996 after the practice of the sytem. Digoxin concentrations were measured in serum by TDxFlex (Abbott Laboratories, U.S.A.). Each patient's digoxin pharmacokinetics was determined by using the Abbott-base Pharmacokinetics system (Abbott Laboratories, U.S.A.) . The interpretation for the assayed digoxin level, the recommendation of maintenance dosage and the simulation graph with predicted serum levels were included in the report. The effectiveness of the reporting system was evaluated by comparing the appropriateness of digoxin level measurement between both groups. RESULTS: It revealed that appropriate measurements of digoxin level were 59.5 % of the tests in A group and 77.1% of those in B group (p=0.006). Evaluation of serum digoxin concentrations stratified by digoxin concentration showed also significant difference among the percentage of tests in each concentration range between both groups (p=0.011). CONCLUSIONS: Interpretative report system for the assayed results caused to increase in the appropriateness of digoxin measurement. The report system with some improvement which is achieved through the active approach to physician helps us use TDM effectively. The system can be applied to the other TDM drugs.
Digoxin
;
Drug Monitoring*
;
Humans
;
Inpatients
;
Pharmacokinetics
5.Initial Experiences of the Interpretative Report System in Therapeutic Drug Monitoring Services.
Korean Journal of Clinical Pathology 1997;17(5):711-717
BACKGROUND: Therapeutic drug monitoring (TDM) has been shown to be effective in minimizing the risk for toxicity and maximizing the efficacy of the drugs. The application of pharmacokinetics principles to indiviualization and optimization of dosage is necessary. We evolved interpretative report system of digoxin determination in a view of individual's pharmacokinetics. The alto of the present study is to validate the effectiveness of the interpretative report system in digoxin therapeutic monitoring service. METHODS: We reviewed 125 inpatients of two groups. 4 group, before interpretative reporting, had 86 inpatients from February 1996 to March 1996. B group included 39 inpatients from September 1996 to October 1996 after the practice of the sytem. Digoxin concentrations were measured in serum by TDxFlex (Abbott Laboratories, U.S.A.). Each patient's digoxin pharmacokinetics was determined by using the Abbott-base Pharmacokinetics system (Abbott Laboratories, U.S.A.) . The interpretation for the assayed digoxin level, the recommendation of maintenance dosage and the simulation graph with predicted serum levels were included in the report. The effectiveness of the reporting system was evaluated by comparing the appropriateness of digoxin level measurement between both groups. RESULTS: It revealed that appropriate measurements of digoxin level were 59.5 % of the tests in A group and 77.1% of those in B group (p=0.006). Evaluation of serum digoxin concentrations stratified by digoxin concentration showed also significant difference among the percentage of tests in each concentration range between both groups (p=0.011). CONCLUSIONS: Interpretative report system for the assayed results caused to increase in the appropriateness of digoxin measurement. The report system with some improvement which is achieved through the active approach to physician helps us use TDM effectively. The system can be applied to the other TDM drugs.
Digoxin
;
Drug Monitoring*
;
Humans
;
Inpatients
;
Pharmacokinetics
6.A Case of Digoxin-induced Catatonic Stupor.
Tae Ick CHUNG ; Jin Kook PARK ; Soung Kyeong PARK ; Joon Seok KIM ; Dong Won YANG ; Beum Saeng KIM
Journal of the Korean Neurological Association 2001;19(4):438-439
We experienced a rare clinical manifestation of a digoxin induced catatonic stupor without other features of digoxin toxicity. This case suggests that the neurological manifestation of digoxin toxicity can occur without the usual side effects. Also, a serum digoxin level should be checked in any elderly patient presenting with abnormal cerebral func-tions, irrespective of whether or not the dose of digoxin has been changed. (J Korean Neurol Assoc 19(4):438~439, 2001)
Aged
;
Digoxin
;
Humans
;
Neurologic Manifestations
;
Stupor*
7.A Study on Relation betwen Red Cell Electrolyte Concentractions and Serum Digoxin Level.
Seong Yun KIM ; Jung Kun LIM ; Ye Hwe KIM ; Young Woo LEE ; Sung Ho LEE
Korean Circulation Journal 1981;11(1):69-86
For the purpose of elucidating relation between red cell electrolyte concentrations and serum digoxin level, measurement of red cell electrolyte concentrations and seum digoxin level by radioimmunoassay were done in 46 normal controls and 63 patients of CHF including 8 patients with digitalis intoxication. The results obtained were as follows: 1. Red cell sodium concentration and ratio of red cell sodium to red cell potassium concentration in normal males were significantly higher than those of females, and red cell potassium concentration in normal males was significantly lower than that of normal females. 2. Red cell potassium concentration in patients of CHF was significantly higher than that of normal controls, but there was no difference in the red cell sodium concentration between the groups. 3. There was no relation between red cell electrolyte concentrations and serum digoxin level, and red cell electrolyte concentration did not exactly estimate serum digoxin level. 4. Red cell electrolyte concentrations in the patient of CHF were valuable in detecting digitalis toxicity.
Digitalis
;
Digoxin*
;
Female
;
Humans
;
Male
;
Potassium
;
Radioimmunoassay
;
Sodium
8.The Clinical Value of the 24-hour Ambulatory ECG Monitoring in Patients with Chronic Atrial Fibrillation.
Chang Heon YANG ; Young Jo KIM ; Bong Sup SHIM ; Hyun Woo LEE
Yeungnam University Journal of Medicine 1989;6(1):99-107
24-hour ambulatory ECG monitoring has been examined for the evaluation of heart rate and longest pause in 34 patients with chronic atrial fibrillation (20 patients treated with digoxin and 14 patients without treatment). Following results were obtained: 1. In 34 patients, the mean of average heart rates was 75.7±13.8/minute, fastest heart rates 148.0±32.4/minute, slowest heart rates 48.1±8.4/minute, difference between fastest and slowest heart rates in individual patients 99.9±29.0/minute and longest pauses 2.95±1.06seconds. The longest pauses of more than 4.0 seconds occurred in 4 of the 34 patients and made an exception of comparison groups. 2. In 27 of the 34 patients, ventricular premature contractures were developed and in 11 of 27, mainly occurred less than 100/24 hours and aberrant conduction occurred in all patients. 3. In 20 patients treated with digoxin (0.25 mg/day), the mean of average heart rates was 78.4±13.7/minute, fastest heart rates 152.5±33.1/minute, slowest heart rates 48.9±8.5/minute, difference between fastest and slowest heart rates in individual patients 103.6±31.7/minute and longest pauses 2.55±0.50 seconds. 4. In 10 patients without treatment, the mean of average heart rates was 78.0±10.7/minute, fastest heart rates 154.5±26.8/minute, slowest heart rates 50.6±7.1/minute, difference between fastest and slowest heart rates in individual patients 103.9±22.2/minute and longest pauses 2.66±0.39 seconds. 5. The difference of heart rates and longest pauses between patients with treatment and without treatment were statistically not significant (P>0.05). In summary, authors seemed to consider that 24-hour ambulatory ECG was useful and safe method for clinical evaluation of patients with chronic atrial fibrillation.
Atrial Fibrillation*
;
Contracture
;
Digoxin
;
Electrocardiography*
;
Heart Rate
;
Humans
;
Methods
9.Annual Report on the External Quality Assessment Scheme for Therapeutic Drug Monitoring and Testing for Drugs of Abuse in Korea (2014).
Dae Hyun KO ; Tae Dong JEONG ; Gum Gyoung GU ; Sail CHUN ; Jeong Ho KIM
Journal of Laboratory Medicine and Quality Assurance 2015;37(1):12-22
As the Therapeutic Drug Monitoring Subcommittee (TDMS) of the Korean Association of Quality Assurance for Clinical Laboratories (KAQACL), we organised two trials as an external quality assessment of therapeutic drug monitoring (TDM) and testing for drugs of abuse (DOA) in 2014. In each trial, low and high level control materials for TDM testing, and positive and negative control materials for DOA testing, were requested from institutions. The number of participating laboratories was 107 for the first trial and 106 for the second. The average number of drug items provided was 5.7 per institution. The most commonly tested substances were, in descending order, valproic acid, digoxin, tacrolimus, phenytoin, and vancomycin. The mean inter-laboratory coefficients of variation for low- and high-level TDM control materials were 8.5% and 7.2%, respectively. The most widely used TDM analysers were the Architect i System (Abbott Diagnostics, USA), followed by the Cobas Integra (Roche Diagnostics, Switzerland) and the Cobas c501 analyser (Roche Diagnostics). The number of participating laboratories for DOA testing was 23% higher that than in 2013. In 96.9% of cases, our analysis confirmed the suitability of the tests at participating DOA laboratories in both trials. In the external quality assessment of TDM by the TDMS of KAQACL in 2014, the overall performance of TDM testing was found to be similar to that observed in the previous years, and inter-laboratory precision was higher than that in 2013. Continuous quality improvement of TDM testing by participation in a proficiency-testing program is necessary.
Digoxin
;
Drug Monitoring*
;
Korea
;
Laboratory Proficiency Testing
;
Phenytoin
;
Quality Improvement
;
Street Drugs*
;
Tacrolimus
;
Valproic Acid
;
Vancomycin
10.Transplacental Fetal Therapy for a Case of Fetal Supraventricular Tachycardia which Caused Fetal Hydrops.
Cheong Rae ROH ; E Suk KANG ; Jong Taek MOON ; Soon Ha YANG ; Jae Hyun CHUNG ; Heung Jae LEE ; Je Ho LEE
Korean Journal of Obstetrics and Gynecology 1997;40(10):2145-2152
A case of fetal supraventricular tachycardia which caused fetal hydrops was diagnosed at 29 weeks of gestation by fetal echocardiography. Transplacental fetal therapy with ma-ternal intravenous digoxin administration resulted in restoration of normal fetal sinus rhythm and disappearance of fetal hydrops on 7th day after initiation of treatment when the mat-ernal serum digoxin level was 2.11 ng/mL. The fetus showed normal sinus rhythm when evaluated by fetal echocardiography during the remainder of pregnancy with maternal oral digoxin maintenence. At birth, the infant did not show any cardiac arrhythmia and hydropic appearance.
Arrhythmias, Cardiac
;
Digoxin
;
Echocardiography
;
Fetal Therapies*
;
Fetus
;
Humans
;
Hydrops Fetalis*
;
Infant
;
Parturition
;
Pregnancy
;
Tachycardia, Supraventricular*