1.Repair of diaphragmatic injury and placement of tube thoracostomy during right upper quadrant peritonectomy.
Nejat OZGUL ; Derman BASARAN ; Gokhan BOYRAZ ; M Coskun SALMAN
Journal of Gynecologic Oncology 2016;27(1):e6-
OBJECTIVE: Patients with advanced or recurrent ovarian cancer often have metastatic disease in the upper abdominal region, especially to the right hemidiaphragm, which requires diaphragmatic resection in order to achieve optimal cytoreduction. The aim of this surgical video is to demonstrate repair of a diaphragmatic injury and placement of tube thoracostomy during right upper quadrant peritonectomy in a patient with recurrent ovarian cancer. METHODS: This is the case of a 45-year-old woman presented with platinum sensitive recurrent ovarian cancer. Abdomen computed tomography also confirmed peritoneal carcinomatosis and pelvic recurrent mass. HIPEC was administered after complete cytoreduction including bilateral upper quadrant peritonectomy, during which diaphragmatic injury occurred near the central tendon and pleural cavity was entered. We inserted a chest tube through the 6th intercostal space in the anterior axillary line in order to prevent postoperative massive pleural effusion. Diaphragmatic defect was closed primarily after the tube placement. The chest tube was withdrawn on the third postoperative day and the patient was discharged on postoperative day 25 without any complications. RESULTS: The central tendon of diaphragm is the most vulnerable part for lacerations. Diaphragmatic repairs could be performed by various techniques; interrupted or continuous, locking or non-locking sutures, with either permanent or absorbable materials. In our view, all of the techniques provide similar results and surgeons can choose any of them as long as they are comfortable with the procedure. CONCLUSION: In most cases, these lacerations can be repaired primarily without necessitating tube thoracostomy. However, performance of HIPEC can cause massive pleural effusions which can lead to significant pulmonary morbidity. Therefore, retrograde placement of the chest tube under direct vision is quite straightforward when the diaphragm is opened.
Chest Tubes
;
Cytoreduction Surgical Procedures/methods
;
Diaphragm/*injuries/*surgery
;
Female
;
Humans
;
Middle Aged
;
Neoplasm Recurrence, Local/surgery
;
Ovarian Neoplasms/*surgery
;
Peritoneum/*surgery
;
Thoracostomy/*methods
2.Does Artificial Ascites Induce the Heat-Sink Phenomenon during Percutaneous Radiofrequency Ablation of the Hepatic Subcapsular Area?: an in vivo Experimental Study Using a Rabbit Model.
Young Sun KIM ; Hyunchul RHIM ; Dongil CHOI ; Hyo K LIM
Korean Journal of Radiology 2009;10(1):43-50
OBJECTIVE: To evaluate the effect of the heat-sink phenomenon induced by artificial ascites on the size of the ablation zone during percutaneous radiofrequency (RF) ablation of the hepatic subcapsular area in an in vivo rabbit model. MATERIALS AND METHODS: A total of 21 percutaneous rabbit liver RF ablations were performed with and without artificial ascites (5% dextrose aqueous solution). The rabbits were divided into three groups: a) control group (C, n = 7); b) room temperature ascites group (R, n = 7); and c) warmed ascites group (W, n = 7). The tip of a 1 cm, internally cooled electrode was placed on the subcapsular region of the hepatic dome via ultrasound guidance, and ablation was continued for 6 min. Changes in temperature of the ascites were monitored during the ablation. The size of the ablation zones of the excised livers and immediate complications rates were compared statistically between the groups (Mann-Whitney U test, Kruskal-Wallis test, linear-by-linear association, p = 0.05). RESULTS: One rabbit from the "W" group expired during the procedure. In all groups, the ascites temperatures approached their respective body temperatures as the ablations continued; however, a significant difference in ascites temperature was found between groups "W" and "R" throughout the procedures (39.2 +/- 0.4 degrees C in group W and 33.4 +/- 4.3 degrees C in group R at 6 min, p = 0.003). No significant difference was found between the size of the ablation zones (782.4 +/- 237.3 mL in group C, 1,172.0 +/- 468.9 mL in group R, and 1,030.6 +/- 665.1 mL in group W, p = 0.170) for the excised liver specimens. Diaphragmatic injury was identified in three of seven cases (42.9%) upon visual inspection of group "C" rabbits (p = 0.030). CONCLUSION: Artificial ascites are not likely to cause a significant heat-sink phenomenon in the percutaneous RF ablation of the hepatic subcapsular region.
Animals
;
*Ascites
;
*Body Temperature
;
Burns/etiology/prevention & control
;
*Catheter Ablation/adverse effects/methods
;
Diaphragm/injuries
;
Glucose/administration & dosage
;
Liver/pathology/*surgery
;
Rabbits
;
Solutions
3.Percutaneous Radiofrequency Ablation for the Hepatocellular Carcinoma Abutting the Diaphragm: Assessment of Safety and Therapeutic Efficacy.
Tae Wook KANG ; Hyunchul RHIM ; Eun Young KIM ; Young Sun KIM ; Dongil CHOI ; Won Jae LEE ; Hyo K LIM
Korean Journal of Radiology 2009;10(1):34-42
OBJECTIVE: To assess the safety and therapeutic efficacy of a percutaneous radiofrequency (RF) ablation for the hepatocellular carcinoma (HCC) abutting the diaphragm. MATERIALS AND METHODS: We retrospectively assessed 80 patients who underwent a percutaneous RF ablation for a single nodular (< 4 cm) HCC over the last four years. Each patient underwent an ultrasound-guided RF ablation using internally cooled electrodes for the first-line treatment. We divided patients into two subgroups based on whether the index tumor was abutting (less than 5 mm) the diaphragm or not: group A (abutting; n = 31) versus group B (non-abutting; n = 49). We compared the two subgroups for complications and therapeutic efficacy using image and the review of medical records. The statistical assessment included an independent t-test, Fisher's exact test, and chi-square test. RESULTS: The assessment of the diaphragmatic swelling at CT immediately following the procedure was more severe in group A than group B (mean thickness change:1.44 vs. 0.46 mm, p = 0.00). Further, right shoulder pain was more common in group A than B (p = 0.01). Although minor complications (hemothorax 1 case, pleural effusion 1 case) were noted only in group A, no major thoracic complication occurred in either group. The technical success rate was lower in group A than group B (84% vs. 98%, p = 0.03). As well, the primary and secondary technique effectiveness rates in group A and group B were 90% versus 98% (p = 0.29) and 79% versus 91% (p = 0.25), respectively. The local tumor progression rate was higher in group A than in group B (29% vs. 6%, p = 0.02). CONCLUSION: We found that the percutaneous RF ablation for the HCC abutting the diaphragm is a safe procedure without major complications. However, it is less effective with regard to technical success and local tumor control.
Adult
;
Aged
;
Aged, 80 and over
;
Burns/etiology
;
Carcinoma, Hepatocellular/pathology/*surgery
;
Catheter Ablation/*adverse effects
;
Diaphragm/injuries/pathology
;
Female
;
Humans
;
Liver Neoplasms/pathology/*surgery
;
Lung Injury/etiology
;
Male
;
Middle Aged
;
Shoulder Pain/etiology
;
Treatment Outcome
;