1.Study on the image file conformance to DICOM standard about medical imaging device.
Chinese Journal of Medical Instrumentation 2013;37(5):327-339
The format of medical image file conformance to DICOM standard have important influence on users of the PACS. This paper summarized the results of the writer's study on the image file conformance to DICOM standard about medical imaging device for many years. The questions of medical image file no conformance to DICOM standard are pointed in detail and the questions resulted from the troubled image files are analyzed. Finally, the methods of avoiding image file no conformance to DICOM standard are presented.
Diagnostic Imaging
;
instrumentation
;
standards
2.A Standard Method for Performance Detection of Fluorescence Imaging System.
Nana LI ; Zhiqiang HUANG ; Zhaotai GU ; Xin AN
Chinese Journal of Medical Instrumentation 2020;44(1):60-64
Fluorescence imaging now becomes an intraoperative navigation technique that gaining popularity in surgery and clinical research. However, at present, there is no mature and reliable method or other related guidance documents for the detection of fluorescence imaging performance. The performance analysis and quality supervision of products on the market could not be performed, which affects their clinical use and image quality. In this paper, a standard method of fluorescence imaging performance testing for fluorescence imaging system is proposed. Several kinds of fluorescence imaging performance parameters affecting fluorescence images are defined strictly. We also recommend scientific and feasible methods for their detections and analyses, which are verified by practical examples. This paper aims to provide a feasible reference standard for fluorescence performance evaluation.
Diagnostic Imaging/instrumentation*
;
Fluorescence
3.The functional integrity of imaging diagnostic equipments.
Hai-Chen SI ; Xiao-Jun LIU ; Gang LIU
Chinese Journal of Medical Instrumentation 2005;29(4):297-309
On the basis of introduction and analysis of three new medical imaging equipments, the article discusses the superiority of the function integrity that is a new concept, and its application in the development of medical equipments in 21st century.
Diagnostic Equipment
;
Diagnostic Imaging
;
instrumentation
4.Study of Image Quality Comparison Based on the MTF Method Between Different Medical Rigid Endoscopes in an In Vitro Model.
Yunlong WANG ; Jun JI ; Changsong JIANG ; Zengyue HUANG
Journal of Biomedical Engineering 2015;32(2):357-362
This study was aimed to use the method of modulation transfer function (MTF) to compare image quality among three different Olympus medical rigid cystoscopes in an in vitro model. During the experimental processes, we firstly used three different types of cystoscopes (i. e. OLYMPUS cystourethroscopy with FOV of 12 degrees, OLYMPUS Germany A22003A and OLYMPUS A2013A) to collect raster images at different brightness with industrial camera and computer from the resolution target which is with different spatial frequency, and then we processed the collected images using MALAB software with the optical transfer function MTF to obtain the values of MTF at different brightness and different spatial frequency. We then did data mathematical statistics and compared imaging quality. The statistical data showed that all three MTF values were smaller than 1. MTF values with the spatial frequency gradually increasing would decrease approaching 0 at the same brightness. When the brightness enhanced in the same process at the same spatial frequency, MTF values showed a slowly increasing trend. The three endoscopes' MTF values were completely different. In some cases the MTF values had a large difference, and the maximum difference could reach 0.7. Conclusion can be derived from analysis of experimental data that three Olympus medical rigid cystoscopes have completely different imaging quality abilities. The No. 3 endoscope OLYMPUS A2013A has low resolution but high contrast. The No. 1 endoscope OLYMPUS cystourethroscopy with FOV of 12 degrees, on the contrary, had high resolution and lower contrast. The No. 2 endoscope OLYMPUS Germany A22003A had high contrast and high resolution, and its image quality was the best.
Diagnostic Imaging
;
instrumentation
;
Endoscopes
;
Endoscopy
;
instrumentation
;
Software
5.Evaluation of tear film and meibomian gland function in dry eye patients using Keratograph 5M.
Kexuan ZHU ; Wenjia XIE ; Jinglu YING ; Yufeng YAO
Journal of Zhejiang University. Medical sciences 2016;45(4):422-428
To assess the application of Keratograph 5M in evaluating tear film and meibomian gland function in patients with dry eye.A total of 144 eyes were recruited in the study, in which 72 eyes were from patients diagnosed with dry eye and 72 eyes were from healthy subjects. All subjects finished following tests or examinations:ocular surface disease index (OSDI) to evaluate eye symptoms; Keratograph 5M examination to obtain tear meniscus height (TMH), noninvasive tear break-up time (NIBUT) including first NIBUT (NIBUT-Fir) and average NIBUT (NIBUT-Ave), and infrared meibography; and fluorescein sodium staining to obtain fluorescein tearbreak-up time (FBUT).Dry eye group had higher OSDI score than healthy control group, but its TMH, NIBUT-Fir and NIBUT-Ave were lower than those in healthy control group (all<0.01). Total meiboscore in dry eye group was higher than that in healthy control group (<0.01), and it showed a significant correlation with NIBUT-Fir and NIBUT-Ave (=-0.449 and -0.398,<0.01), but no correlation with ages was observed (=0.031,>0.05). The NIBUT-Fir and NIBUT-Ave showed a significant correlation with FBUT (=0.833 and 0.727,<0.01).Keratograph 5M is a convenient, accurate and non-invasive method to assess the function of tear film and meibomian gland, and the new meibography scoring system can evaluate the function of meibomian gland objectively and succinctly.
Corneal Topography
;
instrumentation
;
Diagnostic Equipment
;
Dry Eye Syndromes
;
diagnostic imaging
;
Female
;
Humans
;
Male
;
Meibomian Glands
;
diagnostic imaging
;
Tears
;
diagnostic imaging
6.Vein Scanning Projection Instrument Based on Two-Dimensional Scanning Mirror.
Ya MENG ; Zhichao WU ; Changping XU ; Yinbo QIAN
Chinese Journal of Medical Instrumentation 2015;39(5):334-337
With the development of science and technology, new medical equipments is toward the direction of intelligent and portable. In order to assist medical personnel to patients with blood, developing from previous devices, a new kind of vein locating projection instrument based on two-dimensional scanning mirror is put forward. It can scan and project vein image using a scanning mirror. The related algorithm is also be improved, make vein scan projection more practical. The system finally set up can perform well in vein scan projection.
Algorithms
;
Diagnostic Imaging
;
instrumentation
;
Humans
;
Veins
;
anatomy & histology
7.The Application of Compound Tabletop in Medical Imaging Equipment.
Yunping WANG ; Wei WU ; Wenting RUI
Chinese Journal of Medical Instrumentation 2015;39(3):190-191
This paper mainly introduces the material composition and structure of two kinds of compound tabletop which currently used in large medical imaging equipment, also introduces the proper material choosing and production processing, together with the advantage and shortage of this two kinds of tabletop and different application occasion.
Construction Materials
;
Diagnostic Imaging
;
instrumentation
;
Durable Medical Equipment
8.Progress and application of sensors in medicine.
Jianguo LI ; Fei CHEN ; Shuai XU ; Zonghai HUANG
Journal of Biomedical Engineering 2012;29(1):197-200
Sensors are apparatus that can percept specific matter information and change them into useful signals. They are widely used in medicine and are core components of medical equipments, and have become one of critical factors to accelerate the development of medicine. The applications of sensors in medical domain such as assistant examination, monitoring, treatment, disease prevention etc., and their progress tendency, were described detailedly in this article.
Biosensing Techniques
;
instrumentation
;
Capsule Endoscopy
;
instrumentation
;
Diagnostic Imaging
;
instrumentation
;
Fiber Optic Technology
;
instrumentation
;
Humans
;
Monitoring, Physiologic
;
instrumentation
;
Surgery, Computer-Assisted
;
instrumentation
9.The nuclear stethoscope in China.
Chinese Medical Sciences Journal 2009;24(1):1-2
10.Development and clinical application of the tractor for the fracture reduction.
Guo-jun ZHANG ; Li-min JIA ; Pei-de FEN ; Lian-gen WU ; Hui-jun ZHANG
Chinese Journal of Medical Instrumentation 2002;26(4):275-278
This paper expounds how the tractor for the fracture reduction works. The clinical results show that the traction apparatus is a labour-saving and time-saving orthopedic device with simple operation and few suffering to patients.
Arm Injuries
;
diagnostic imaging
;
surgery
;
Equipment Design
;
Fracture Fixation
;
instrumentation
;
methods
;
Fractures, Bone
;
diagnostic imaging
;
surgery
;
Humans
;
Leg Injuries
;
diagnostic imaging
;
surgery
;
Radiography
;
Traction
;
instrumentation
;
methods