1.Analysis on teaching status and reform plan of medical imaging equipment
China Medical Equipment 2016;13(3):137-138,139
Objective:To analyze the teaching status of medical imaging equipment and the requirement of medical imaging equipment for graduates majored in medical imaging technique, and then make great progress in the teaching reform of medical imaging equipment.Methods:Discussed with students, conduct investigations and surveys on kinds of hospital in Beijing, and analyzed the survey data.Results: With the analysis of survey, the teaching reform scheme was proposed in the course.Conclusion: To establish the foundation for the teaching reform of medical imaging equipment.
2.A study on constructing the practice training platform of medical imaging technology in the higher vocational education conforming to the demand of society
China Medical Equipment 2017;14(3):134-136
Objective:To establish the practice training platform of medical imaging technology conforming to the demand of society and the characteristics of vocational education, and improve the training conditions and promote the quality of higher vocational talent cultivation.Methods: To carry out investigation and expert interviews in various grade hospital; analyze vocation standard and skill training grade; plan and design the layout and function position of hardware for this training platform; and then take practice research for application of this platform.Results: The training platform of medical imaging technology has been established which includes 14 digital training rooms. Every teaching function, such as radiology registration, detection, image processing, diagnostic reporting, report printing and storage capability, could achieve and correspond to a clinical task.Conclusion:This study effectively improves medical imaging technology vocational practice conditions, and has a great significance to improve teaching quality of education and ensure quality of talents cultivation.
3.Development of maintenance learning machine of ventilator for teaching
Guangxing ZHANG ; Dewu YANG ; Zhun QIU
China Medical Equipment 2017;14(4):45-48
Objective: To design a new type of maintenance learning machine of ventilator for teaching and experiment combined with electronic technology course of higher vocational education. Methods: ACM804 ventilator was chosen as prototype machine and the electronic technology course of higher vocational education was chosen as theory basis. The designs of internal circuit and gas circuit of prototype machine were improved, besides, some test points and failure points were designed for teaching in classroom. Results: This machine not only could realize all functions of prototype machine, but also could carry forward test teaching and contribute students to maintain common failure in accordance with course content. Conclusion: Through the design of teaching experiment and using of learning machine, the new machine has achieved better teaching effect for students to grasp machine theory and operate actual circuit.
4.Treatment of blunt liver injury:a report of 109 cases
Changan YANG ; Dewu ZHONG ; Zhikang CHEN
Chinese Journal of General Surgery 2000;0(12):-
Objective To explore the feasibility and indications of non-operative management for blunt liver injury.Methods The clinical data of 109 patients with blunt liver injury treated in recent 5 years were reviewed retrospectively.Results Among 109 cases, 35 were treated with nonoperation and 33(94.3 %) were cured; there were 3 cases(9.1 %) with complications among the 33 cases who were cured. The mean amount of blood transfusion, hospitalization days and expenses were (2.5?0.8)U,(13.2?1.3)d and (5 250?335) yuan, respectively. Seventy-four cases were treated with operation and 68(91.2 %)were cured, there were 14 cases (20.6 %) with complications among the 68 cases who were cured. The mean amount of blood transfusion,number of hospitalization days and expenses were (8.4?1.1)U,(15.4?0.9)d and (13 550?805) yuan,respectively.The mean amount of blood transfusion and hospitalization expenses of nonoperative group were lower than those of operative group (P
5.The Expression of hMLH_1, hMSH_2 in Hepatocellular Carcinoma and Its Clinical Significance
Gang LIANG ; Dewu ZHONG ; Zhulin YANG
Journal of Chinese Physician 2001;0(06):-
Objective To study the expression of hMLH1, hMSH2 and their association with clinico-pathological characteristics in hepatocellular carcinoma(HCC). Methods The expression of hMLH1 and hMSH2 in 37 HCC tissues was detected by SABC immunohistochemistry. Results The positive rate (score) of hMLH1 and hMSH2 expression in HCC was 48.7%(1.65?1.70) and 59.5%(2.30?1.96), respectively, which was obviously lower than that in the adjancent tumor tissues with 83.8%(3.30?1.37), and 86.5%(4.30?2.01), and in the normal liver tissues with 88.2%(3.88?1.98) and 82.3%(4.29?1.83), respectively(P
6.Inhibition of HMGB1 expression and release by nicotine in RAW264.7 cells
Guoying ZHANG ; Zhongfu ZHAO ; Mingshe LIU ; Dewu HAN ; Huiying ZHANG ; Liuxu YANG
Chinese Journal of Pathophysiology 2010;26(1):37-41
AIM: To investigate that nicotine inhibits HMGB1 expression and release in RAW264.7 cells.METHODS: (1) RAW264.7 cells were cultured in 6 wells plate, treated with 250 μg/L LPS and 1 μmol/L or 10 μmol/L nicotine, in which the cells treated with or without 250 μg/L LPS were regarded as nicotine 1 group (N1), nicotine 2 group (N2), LPS group (LPS) and control group (C), respectively. HMGB1 protein in the cell culture media and in cell nuclear was examined by Western blotting and the cellular HMGB1 mRNA level was detected by RT-PCR. (2) Transfected with antisense RNA or sense RNA of α~7 subunit-containing nicotinic receptor (α~7nAChR), RAW264.7 cells were treated with 250 μg/L LPS and 10 μmol/L nicotine, HMGB1 protein in the culture media was also tested by Western blotting.RESULTS: (1) HMGB1 mRNA level in C group was low (1 659.20±121.05) and no significant statistical difference among groups of N1, N2 and LPS was observed (P>0.05). (2) Higher HMGB1 accumulation in the cell culture media was detected in LPS group (445.34±28.52) than that in C group. Compared to LPS group, both N1 and N2 groups distinctly attenuated HMGB1 accumulation in culture media (P<0.05). (3) Nuclear HMGB1 accumulation was lower in LPS group than that in C group, and two different nicotine concentrations markedly increased the nuclear HMGB1 accumulation compared to LPS group (P<0.05). (4) No significant difference of HMGB1 levels in culture media between antisense RNA group and LPS group was observed (P>0.05). In sense RNA group, however, HMGB1 level was observably reduced compared to antisense group (P<0.05).CONCLUSION: The present results suggest that nicotine dramatically inhibits RAW264.7 cell nuclear HMGB1 translocation and extracellular release, and this effect relies on α~7nAch receptor expression.
7.Expression and significance of smad_4mRNA,TGF-?_1 ,and TGF-?R_1 in pancreatic carcinoma
Zhongcheng HUANG ; Zhulin YANG ; Yongguo LI ; Dewu ZHONG ; Qunwei WANG ; Shengfu HUANG
Chinese Journal of General Surgery 2001;0(10):-
Objective To study the significance of expressions of smad_4mRNA,TGF-?_1, and TGF-?R_1 in pancreatic carcinoma(PC) . Methods Smad_4mRNA was detected by in situ hybridization. TGF-?_1 and TGF-?R_1 were detected by immunohistochemical method. Results The positive rates of smad_4mRNA,TGF-?_1 and TGF-?R_1 were singnificantly lower in 53 slices of pancreatic carcinoma than those in 25 slices of paracancerous tissue (all P
8.Effect of adenovirus-mediated myoglobin gene expression in decreasing hepatic ischemia reperfusion injury
Xundi XU ; Shengfu HUANG ; Jixiong HU ; Qinglong LI ; Leping YANG ; Qunwei WANG ; Guoli LIU ; Zhulin YANG ; Yongguo LI ; Dewu ZHONG ; Xiongying MIAO
Chinese Journal of General Surgery 2001;0(09):-
Objective To study the effect of expression of myoglobin which mediated by adenovirus,on ATP value of liver and the protective effect on liver ischemia reperfusion injury.Methods Adenovirus carrying CMV promoter sequences linked to the human myoglobin gene(AdCMVMyo) were transfected into rats liver. Then myoglobin, hepatic ATP levels and liver function were evaluated. Results Myoglobin expression was verified in rat livers after AdCMVMyo transfection. The ATP levels in rat livers 72 hours after AdCMVMyo transfection were significantly higher than that in control group(P
9.Effects of organ dose modulation technique on image quality and radiation dose in sinus CT scanning
Dewu YANG ; Yan SUI ; Kang LIU ; Yantao NIU
Chinese Journal of Radiological Medicine and Protection 2022;42(3):230-234
Objective:To investigate the effects of organ dose modulation (ODM) on image quality and radiation dose to lens during sinus CT scanning.Methods:The GE Revolution EVO CT was used to scan the anthropomorphic head with ODM turned off as the control group and ODM turned on as the observation group. With different parameter combinations of tube voltage (140, 120, 100 kV), noise index (N17, N18), pitch (0.531, 0.969 at 20 cm collimation width, 0.516, 0.984 at 40 mm collination width), 24 series of images were acquired respectively. The tube current (mA) valuesat the anterior (A), left (L), posterior (P) and right (R) positions, volume CT dose index (CTDI vol) and dose length product (DLP) were recorded. Average CT values (AV), standard deviation (SD), signal-to-noise ratio (SNR), contrast to noise ratio (CNR) and image quality factor (FOM) of ROI were calculated. Double blind method was used to evaluate the edge sharpness, soft tissue level, noise and artifact on a subjective scale of 3 points. Results:For the combinations of different scanning parameters, the radiation dose of the observation group was lower than that of the control group. The tube current attheposition A for the observation group was lower than that of the control group, and the difference was statistically significant ( t=2.28, P<0.05). The differences oftube currentsatposotions of L, P and R, CTDI vol and DLP values in twogroupswere not statistically significant ( P>0.05). There were no significant differences in SD, SNR, CNR and FOM between the two groups of images ( P>0.05). There were no significant differences in the subjective scores of edge sharpness, soft tissue gradation, noise and artifacts between the two groups ( P>0.05). Conclusions:ODM technique can effectively reduce the radiation dose of eye lens without decompromising the image quality, which could meet the requirements of diagnosis, and accord with the principle of radiological protection optimization.
10.The influence of different CT scanning protocols on AI detection efficiency and radiation dose of solid nodules in chest phantom
Haimei LI ; Kang LIU ; Yan SUI ; Zhiyuan GAO ; Dewu YANG
Chinese Journal of Radiological Medicine and Protection 2023;43(3):216-221
Objective:To investigate the radiation dose and detection efficiency of artificial intelligence (AI) system for solid nodules in chest phantom with different scanning protocols.Methods:A total of 60 simulated nodules with different CT values and diameters were uniformly placed in each lung lobe and lung segment of the anthropomorphic chest phantom. GE Revolution evo CT was used to scan the chest phantom. 64 groups of images with different scanning parameters were collected at the tube voltage of 80, 100, 120, 140 kV, different noise indexes (NI 10-40 with interval 2), and other fixed parameters. The detection result of simulated nodules were recorded on AI software, and the detection rate and false detection rate were calculated, respectively, for different shapes of nodules. The mean volume CT dose index (CTDI vol) and dose length product (DLP) of each scan were recorded. Results:There were no statistically significant differences in the detection rate and false detection rate of spherical nodules and irregular nodules at different tube voltages( P > 0.05), but there were and statistically significant with different noise indices ( F=10.57, 17.77, 9.33, P < 0.001). Different tube voltages had no statistical significance for CTDI vol and DLP ( P > 0.05), while different noise indices had statistical significance for CTDI vol and DLP ( F=59.87, 60.92, P < 0.001). The detection rates of nodules were moderately or weakly correlated with noise indices, CTDI vol and DLP ( r=0.43, 0.56, -0.58, -0.78, P<0.05), but no correlation with tube voltage ( P>0.05). Conclusions:Scanning protocol has an impact on AI detection efficiency of pulmonary nodules. Reasonable scanning parameters should be selected according to different image quality requirements in clinical practice.