1.Association of coronary flow reserve by dipyridamole technetium-99m sestamibi single photon emission computed tomography with perfusion findings and risk factors for coronary artery disease.
Tumapon Deverly D. ; Obaldo Jerry M.
The Philippine Journal of Nuclear Medicine 2015;10(1):8-14
BACKGROUND: Blunting of coronary flow reserve (CFR) may precede overt ischemia. The study aimed to correlate CFR with perfusion findings and risk factors for coronary artery disease (CAD).
METHODS: Fifty-four consecutive patients underwent dipyridamole-rest technetium-99m sestamibi single photon emission computed tomography (SPECT) on two separate days. CFR was computed as the quotient of myocardial blood flow (MBF= global tissue perfusion divided by arterial input function) at stress and at rest.
RESULTS: CFR was significantly lower in patients with abnormal perfusion vs normals (p=0.005). Reduced CFR was noted in 83% of patients with normal SPECT. Lower CFR was seen in hypertensive patients with left ventricular hypertrophy (LVH) compared to those without LVH (p=0.029); likewise in DM vs no DM (p=0.121). Independent predictors of reduced CFR were age and extent of ischemia.
CONCLUSION: Abnormal perfusion is associated with reduced CFR. In those with normal perfusion, there is a high prevalence of reduced CFR, which may be attributed to the presence of risk factors for CAD and LVH.
Human ; Male ; Female ; Arteries ; Coronary Artery Disease ; Dipyridamole ; Hypertrophy, Left Ventricular ; Risk Factors ; Technetium Tc 99m Sestamibi ; Tomography, Emission-computed, Single-photon
2.Prognostic value of coronary flow reserve (CFR) by dipyridamole single-photon emission computed tomography (SPECT) sestamibi imaging in predicting future cardiac events.
Tumapon Deverly D. ; Obaldo Jerry M.
The Philippine Journal of Nuclear Medicine 2016;11(1):14-23
OBJECTIVES: Impairment of coronary flow reserve (CFR) precedes preclinical atherosclerosis. However, data are lacking regarding its prognostic utility using SPECT imaging. Thus, this study aimed to determine the clinical utility of CFR by sestamibi imaging in predicting future cardiac events in patients with normal and abnormal myocardial perfusion scan (MPS).
METHODS: This was a prospective cohort study of 54 consecutive adult patients with suspected coronary artery disease referred to Nuclear Medicine Division, Philippine Heart Center for dipyridamole technetium-99m sestamibi SPECT MPS from August 2012 to September 2013. Patients with normal (summed stress score, SSS <3) and abnormal (SSS> 4) perfusion scans were further subdivided based on their CFR whether normal (CFR> 2) or abnormal (CFR < 2). Using a validated 2-day protocol, estimated CFR was computed from the ratio of dipyridamole myocardial blood flow (MBE) to resting MBF. MBF was obtained by dividing the global myocardial counts with the arterial input function. Global myocardial counts were derived from the average of the mean counts/pixel of two representative short-axis tomograms at the mediobasal and medioapical views. For the arterial input function, first-pass analysis of the pulmonary artery was performed to generate the time-activity curve (TAC). The mean counts/pixel of the area under the curve represented the input junction. Patients were monitored for major adverse cardiac events (MACE) through phone contact by patient and by review of hospital and physician's record six months after scintigraphy (mean follow-up 9+3 months). Major cardiac events include cardiac death, acute coronary syndrome, unstable angina, and revascularization.
RESULTS: A prospective cohort of 54 consecutive patients with no known CAD, were enrolled in the study. Abnormal MPI revealed significantly lower CFR (1.64 + 0.47 vs. 1.19 + 0.36, p=0.005). The annual cardiac event rate increased in the presence of reduced CFR in spite of a normal MPI (from 0% to 6.9%), and was even higher when both MPI and CFR were abnormal (from 0% to 34.7%). In Kaplan-Meier analysis, patients with abnormal perfusion revealed-significantly higher incidence of cardiac events compared with normal perfusion (chi-square 4.93, p=0.027). There was a trend towards increased incidence of cardiac events in patients with abnormal CFR; however, this did not reach statistical significance (chi-square 0.61, p=0.434).
CONCLUSION: A low CFR was associated with an increased incidence of MACE, particularly in the presence of abnormal perfusion findings.
Human ; Male ; Female ; Adult ; Technetium Tc 99m Sestamibi ; Dipyridamole ; Acute Coronary Syndrome ; Kaplan-meier Estimate ; Heart ; Angina, Unstable ; Myocardium
3.Value of Tl-201 imaging in predicting therapeutic I-131 uptake in patients with thyroglobulin-positive but I-131 scan negative differentiated thyroid cancer.
Obaldo Jerry M ; Tumapon Deverly D
The Philippine Journal of Nuclear Medicine 2016;11(1):8-13
BACKGROUND: Serum thyroglobulin assays and I-131 imaging and routinely employed for the detection of remaining functioning thyroid tissue after surgery and radioiodine therapy. However, the sensitivity of I-131 is suboptimal resulting in cases of positive thyroglobulin test but negative I-131 imaging, potentially creating a dilemma in subsequent therapeutic management. Other radiopharmaceuticals, such as TI-201 may offer better sensitivity, although it is not clear whether this contributes to the decision-making for subsequent I-131therapy. This prospective cohort study aimed to determine if Tl-201 imaging identified thyroid tissues that will take up therapeutic I-131, and to help define its clinical utility.
METHODS: Fourteen consecutive patients who underwent surgery for well-differentiated thyroid cancer, had I-131 therapy at least eight months previously, and with elevated thyroglobulin (>10 ng/mL) but negative pre-therapy (111 MBq) I-131 whole body scan (WBS), were enrolled in the study. WBS was done using 56.74 MBq of Tl-201. All patients had repeat I-131 ablation (3.7-7.4GBq) one to two months after Tl-201 imaging. Post-therapy WBS was done four to seven days after.
RESULTS: All 14 patients had papillary thyroid carcinoma. Ten patients had a positive Tl-201 scan. Of the 14 subjects, only two had a positive post-therapy I-131 WBS, both whom had a positive Tl-201 scan. Thallium-201 scanning showed a fairly high sensitivity (71%) in demonstrating thyroid remnants or metastases using a thyroglobulin level of >10 ng/mL as standard. However, a positivel Tl-201 scan only has a predictive value of 20% for subsequent uptake of therapeutic I-131 as shown in the post-therapy scan.
CONCLUSION: Thallium-201 uptake correlates poorly with therapeutic I-131 uptake in thyroglobulin-positive, but I-131 scan-negative, differentiated thyroid cancer patients. Results of this study suggest that the presence of thyroid remnants and metastases on Tl-201 imaging is inappropriate as a basis for subsequent I-131 therapy.
Human ; Male ; Female ; Middle Aged ; Adult ; Thyroglobulin ; Thyroid Cancer, Papillary ; Radiopharmaceuticals ; Iodine Radioisotopes ; Thallium ; Thyroid Neoplasms ; Carcinoma ; Neoplasms, Second Primary ; Thallium Radioisotopes
4.Value of Tl-201 imaging in predicting therapeutic I-131 uptake in patients with thyroglobulin-positive but I-131 scan negative differentiated thyroid cancer.
Jerry M OBALDO ; Deverly D TUMAPON
The Philippine Journal of Nuclear Medicine 2016;11(1):8-13
BACKGROUND: Serum thyroglobulin assays and I-131 imaging and routinely employed for the detection of remaining functioning thyroid tissue after surgery and radioiodine therapy. However, the sensitivity of I-131 is suboptimal resulting in cases of positive thyroglobulin test but negative I-131 imaging, potentially creating a dilemma in subsequent therapeutic management. Other radiopharmaceuticals, such as TI-201 may offer better sensitivity, although it is not clear whether this contributes to the decision-making for subsequent I-131therapy. This prospective cohort study aimed to determine if Tl-201 imaging identified thyroid tissues that will take up therapeutic I-131, and to help define its clinical utility.
METHODS: Fourteen consecutive patients who underwent surgery for well-differentiated thyroid cancer, had I-131 therapy at least eight months previously, and with elevated thyroglobulin (>10 ng/mL) but negative pre-therapy (111 MBq) I-131 whole body scan (WBS), were enrolled in the study. WBS was done using 56.74 MBq of Tl-201. All patients had repeat I-131 ablation (3.7-7.4GBq) one to two months after Tl-201 imaging. Post-therapy WBS was done four to seven days after.
RESULTS: All 14 patients had papillary thyroid carcinoma. Ten patients had a positive Tl-201 scan. Of the 14 subjects, only two had a positive post-therapy I-131 WBS, both whom had a positive Tl-201 scan. Thallium-201 scanning showed a fairly high sensitivity (71%) in demonstrating thyroid remnants or metastases using a thyroglobulin level of >10 ng/mL as standard. However, a positivel Tl-201 scan only has a predictive value of 20% for subsequent uptake of therapeutic I-131 as shown in the post-therapy scan.
CONCLUSION: Thallium-201 uptake correlates poorly with therapeutic I-131 uptake in thyroglobulin-positive, but I-131 scan-negative, differentiated thyroid cancer patients. Results of this study suggest that the presence of thyroid remnants and metastases on Tl-201 imaging is inappropriate as a basis for subsequent I-131 therapy.
Human ; Male ; Female ; Middle Aged ; Adult ; Thyroglobulin ; Thyroid Cancer, Papillary ; Radiopharmaceuticals ; Iodine Radioisotopes ; Thallium ; Thyroid Neoplasms ; Carcinoma ; Neoplasms, Second Primary ; Thallium Radioisotopes
5.Comparison of image quality, diagnostic accuracy, and LV parameters in filtered backprojection versus iterative SPECT Reconstruction in Myocardial Perfusion Scintigraphy
Deverly D. Tumapon ; Jerry M. Obaldo
The Philippine Journal of Nuclear Medicine 2022;17(1):24-33
Background:
Myocardial perfusion scintigraphy images with iterative reconstruction showed higher qualitative and
quantitative estimates.
Objective:
This study was conducted to compare image quality, diagnostic accuracy, and LV parameters with standard FBP versus OSEM as baseline quality assurance for the choice of reconstruction algorithm most applicable in the local setting.
Methods:
This was a retrospective cross-sectional study of 55 Thallium-201 (Tl-201) scans and 14 Techentium-99m
sestamibi (Tc-99m) images that were reprocessed with filtered backprojection (FBP) and with ordered subset expectation maximization (OSEM). The image quality, diagnostic accuracy, and LV parameters of both SPECT reconstructions were compared.
Results:
OSEM reconstruction resulted in a significantly smooth background tracer activity as opposed to the standard FBP in both Tl-201 (p<0.01) and Tc-99m (p=0.01) scans. Distinct LV border was superiorly seen in OSEM. There was no significant difference in the diagnostic accuracy between the two reconstruction parameters despite 2 cases of interpretation discrepancies. End-diastolic volume generated by OSEM was significantly higher (117.60+55.14 vs 118.51+55.11, p<0.01 in Tl-201 and 101.07+75.58 vs 104.29+80.39, p =0.01 in Tc-99m). With Tc-99m scans the end-systolic volume and ejection fraction in OSEM were likewise significantly different from FBP (p=0.04 and p<0.01, respectively).
Conclusion
OSEM reconstruction offers smooth background tracer activity with comparable diagnostic accuracy to FBP. All the LV parameters in OSEM were significantly different from FBP in Tc-99m scans and only the EDV in thallium images.
6.Prognostic value of coronary flow reserve (CFR) by dipyridamole single-photon emission computed tomography (SPECT) sestamibi imaging in predicting future cardiac events.
Deverly D. TUMAPON ; Jerry M. OBALDO
The Philippine Journal of Nuclear Medicine 2016;11(1):14-23
OBJECTIVES: Impairment of coronary flow reserve (CFR) precedes preclinical atherosclerosis. However, data are lacking regarding its prognostic utility using SPECT imaging. Thus, this study aimed to determine the clinical utility of CFR by sestamibi imaging in predicting future cardiac events in patients with normal and abnormal myocardial perfusion scan (MPS).
METHODS: This was a prospective cohort study of 54 consecutive adult patients with suspected coronary artery disease referred to Nuclear Medicine Division, Philippine Heart Center for dipyridamole technetium-99m sestamibi SPECT MPS from August 2012 to September 2013. Patients with normal (summed stress score, SSS <3) and abnormal (SSS> 4) perfusion scans were further subdivided based on their CFR whether normal (CFR> 2) or abnormal (CFR < 2). Using a validated 2-day protocol, estimated CFR was computed from the ratio of dipyridamole myocardial blood flow (MBE) to resting MBF. MBF was obtained by dividing the global myocardial counts with the arterial input function. Global myocardial counts were derived from the average of the mean counts/pixel of two representative short-axis tomograms at the mediobasal and medioapical views. For the arterial input function, first-pass analysis of the pulmonary artery was performed to generate the time-activity curve (TAC). The mean counts/pixel of the area under the curve represented the input junction. Patients were monitored for major adverse cardiac events (MACE) through phone contact by patient and by review of hospital and physician's record six months after scintigraphy (mean follow-up 9+3 months). Major cardiac events include cardiac death, acute coronary syndrome, unstable angina, and revascularization.
RESULTS: A prospective cohort of 54 consecutive patients with no known CAD, were enrolled in the study. Abnormal MPI revealed significantly lower CFR (1.64 + 0.47 vs. 1.19 + 0.36, p=0.005). The annual cardiac event rate increased in the presence of reduced CFR in spite of a normal MPI (from 0% to 6.9%), and was even higher when both MPI and CFR were abnormal (from 0% to 34.7%). In Kaplan-Meier analysis, patients with abnormal perfusion revealed-significantly higher incidence of cardiac events compared with normal perfusion (chi-square 4.93, p=0.027). There was a trend towards increased incidence of cardiac events in patients with abnormal CFR; however, this did not reach statistical significance (chi-square 0.61, p=0.434).
CONCLUSION: A low CFR was associated with an increased incidence of MACE, particularly in the presence of abnormal perfusion findings.
Human ; Male ; Female ; Adult ; Technetium Tc 99m Sestamibi ; Dipyridamole ; Acute Coronary Syndrome ; Kaplan-meier Estimate ; Heart ; Angina, Unstable ; Myocardium