1.The influence of p53 mutation status on the anti-cancer effect of cisplatin in oral squamous cell carcinoma cell lines.
Deuk Won JO ; Young Kyun KIM ; Pil Young YUN
Journal of the Korean Association of Oral and Maxillofacial Surgeons 2016;42(6):337-344
OBJECTIVES: The purpose of this study was to evaluate the anti-cancer activity of cisplatin by studying its effects on cell viability and identifying the mechanisms underlying the induction of cell cycle arrest and apoptosis on oral squamous cell carcinoma (OSCC) cell lines with varying p53 mutation status. MATERIALS AND METHODS: Three OSCC cell lines, YD-8 (p53 point mutation), YD-9 (p53 wild type), and YD-38 (p53 deletion) were used. To determine the cytotoxic effect of cisplatin, MTS assay was performed. The cell cycle alteration and apoptosis were analyzed using flow cytometry. Western blot analysis was used to detect the expression of cell cycle alteration- or apoptosis-related proteins as well as p53. RESULTS: Cisplatin showed a time- and dose-dependent anti-proliferative effect in all cell lines. Cisplatin induced G2/M cell accumulation in the three cell lines after treatment with 0.5 and 1.0 µg/mL of cisplatin for 48 hours. The proportion of annexin V-FITC-stained cells increased following treatment with cisplatin. The apoptotic proportion was lower in the YD-38 cell line than in the YD-9 or YD-8 cell lines. Also, immunoblotting analysis indicated that p53 and p21 were detected only in YD-8 and YD-9 cell lines after cisplatin treatment. CONCLUSION: In this study, cisplatin showed anti-cancer effects via G2/M phase arrest and apoptosis, with some difference among OSCC cell lines. The mutation status of p53 might have influenced the difference observed among cell lines. Further studies on p53 mutation status are needed to understand the biological behavior and characteristics of OSCCs and to establish appropriate treatment.
Apoptosis
;
Blotting, Western
;
Carcinoma, Squamous Cell*
;
Cell Cycle
;
Cell Cycle Checkpoints
;
Cell Line
;
Cell Survival
;
Cisplatin*
;
Epithelial Cells*
;
Flow Cytometry
;
Immunoblotting
2.Mucoepidermoid Carcinoma of the Thymus: A Case Report.
Gang Deuk KIM ; Hye Won KIM ; Jung Taek OH ; Hyang Jeong JO ; Seon Kwan JUHNG
Journal of Korean Medical Science 2004;19(4):601-603
Mucoepidermoid carcinoma of the thymus is an extremely rare malignant mediastinal neoplasm, and to our knowledge, only 13 cases have been reported. We report a case of mucoepidermoid carcinoma of the thymus that was seen in a 53-yr-old man with right chest pain. Chest CT scan showed a huge, cystic mass having a focal solid portion with direct invasion of the adjacent anterior chest wall and pericardium in the anterior mediastinum. Mucoepidermoid carcinoma of the thymus should be included in the differential diagnosis for masses of the anterior mediastinum associated with extensive cystic changes, although the carcinoma is exceedingly rare.
Carcinoma, Mucoepidermoid/*diagnosis/pathology
;
Fatal Outcome
;
Humans
;
Male
;
Mediastinal Neoplasms/*diagnosis/pathology
;
Middle Aged
;
Thymus Neoplasms/*diagnosis/pathology
3.Cervical Spondylolysis in Child with Four Levels of Simultaneous Involvement: A Case Report.
Gang Deuk KIM ; Hye Won KIM ; Sung Jo JANG ; Jung Taek OH
Journal of the Korean Radiological Society 2006;55(6):619-622
Cervical spondylolysis is a rare condition, and less than 100 cases have been reported in the world literature. Cervical spondylolysis is defined as a well corticated defect in the posterior element of a cervical vertebra. Although the etiology of cervical spondylolysis is unknown, its association with dysplastic changes and spina bifida occulta suggest that the lesion is congenital. Here, we describe the radiographs and CT images of cervical spondylolysis involving four levels in a 9 year old boy.
Child*
;
Humans
;
Male
;
Spina Bifida Occulta
;
Spine
;
Spondylolysis*
4.A clinical study of breast cancer.
Dong Young NOH ; Deuk Ho CHA ; Jae Won JO ; Young Jin SONG ; Oh Jung KWON ; In Kyu HONG ; Kuk Jin CHOE ; Jin Pok KIM
Journal of the Korean Cancer Association 1991;23(2):410-417
No abstract available.
Breast Neoplasms*
;
Breast*
5.Effects of Botulinum Toxin A Injection into Salivary Glands of Patients with Brain Lesion Suffering from Posterior Drooling.
Zee Ihn LEE ; Dong Hwi PARK ; Dong Hyun JO ; Won Duck CHOI ; Seung Deuk BYUN
Brain & Neurorehabilitation 2011;4(2):121-125
OBJECTIVE: The aim of the study was to evaluate the effectiveness of ultrasouond-guided salivary gland injection of botulinum toxin A (BTX-A) for posterior drooling. METHOD: 11 patients with brain lesion (9 cerebral palsy, 1 hypoxic ischemic encephalopathy and 1 mental retardation) with posterior drooling (an initial PDAS score greater than 2) and related pulmonary problems were recruited. Drooling severity was measured at baseline, 4 weeks, 3 months and 6 months after botulinum toxin A injection, by using Teacher Drooling Scale (TDS), Visual Analogue Scales (VAS), Drooling Score System (DSS)-severity, frequency and Posterior Drooling/Aspiration System (PDAS). RESULTS: The TDS, DSS-severity, DSS-frequency, VAS, PDAS were significantly reduced at 4 weeks and 3 months after BTX-A injection into salivary glands compared to pre-injection (p<0.05). However, there were no significant changes at 6 months compared to pre-injection level. CONCLUSION: BTX-A injection into salivary glands may improve anterior drooling in patients with brain lesions. Furthermore BTX-A injection into salivary glands may also decrease the posterior drooling which might related to respiratory symptoms in aspiration pneumonia.
Botulinum Toxins
;
Botulinum Toxins, Type A
;
Brain
;
Cerebral Palsy
;
Humans
;
Hypoxia-Ischemia, Brain
;
Pneumonia, Aspiration
;
Salivary Glands
;
Sialorrhea
;
Sorbitol
;
Stress, Psychological
;
Tyramine
;
Weights and Measures
6.A Case of Chinese Herbs Nephropathy.
Ki Deuk NAM ; Tae Won LEE ; Jung Heun NOH ; Mun Ho YANG ; Byung Su JO ; Seong Pyo HONG ; Chun Gyoo IHM ; Myung Jae KIM
Korean Journal of Nephrology 2000;19(4):751-755
No abstract available.
Asian Continental Ancestry Group*
;
Humans
7.The fracture resistance of heat pressed ceramics with wire reinforcement.
Deuk Won JO ; Jin Keun DONG ; Sang Chun OH ; Yu Lee KIM
The Journal of Korean Academy of Prosthodontics 2009;47(2):191-198
STATEMENT OF PROBLEM: Ceramics have been important materials for the restoration of teeth. The demands of patients for tooth-colored restorations and the availability of various dental ceramics has driven the increased use of new types of dental ceramic materials. Improved physical properties of theses materials have expanded its use even in posterior crowns and fixed partial dentures. However, ceramic still has limitation such as low loading capability. This is critical for long-span bridge, because bridge is more subject to tensile force. PURPOSE: The wire reinforced ceramic was designed to increase the fracture resistance of ceramic restoration. The purpose of this study was to evaluate the fracture resistance of wire reinforced ceramic. MATERIAL AND METHODS: Heat pressed ceramic (ingot No.200 : IPS Empress 2, Ivoclar Vivadent, Liechtenstein) and Ni-Cr wire (Alfa Aesar, Johnson Matthey Company, USA) of 0.41 mm diameter were used in this study. Five groups of twelve uniform sized ceramic specimens (width 4 mm, thickness 2 mm, length 15 mm) were fabricated. Each group had different wire arrangement. Wireless ceramic was used as control group. The experimental groups were divided according to wire number and position. One, two and three strands of wires were positioned on the longitudinal axis of specimen. In another experimental group, three strands of wires positioned on the longitudinal axis and five strands of wires positioned on the transverse axis. Three-point bending test was done with universal testing machine (Z020, Zwick, Germany) to compare the flexural modulus, flexural strength, strain at fracture and fracture toughness of each group. Fractured ceramic specimens were cross-sectioned with caborundum disc and grinded with sandpaper to observe interface between ceramic and Ni-Cr wire. The interface between ceramic and Ni-Cr wire was analyzed with scanning electron microscope (JSM-6360, JEOL, Japan) under platinum coating. RESULTS: The results obtained were as follows: 1. The average and standard deviation in flexural modulus, flexural strength and fracture toughness showed no statistical differences between control and experimental groups. However, strain was significantly increased in wire inserted ceramics (P < .001). 2. Control group showed wedge fracture aspects across specimen, while experimental groups showed cracks across specimen. 3. Scanning electron microscopic image of cross-sectioned and longitudinally-sectioned specimens showed no gap at the interface between ceramic and Ni-Cr wire. CONCLUSION: The results of this study showed that wire inserted ceramics have a high strain characteristic. However, wire inserted ceramics was not enough to use at posterior area of mouth in relation to flexural modulus and flexural strength. Therefore, we need further studies.
Acrylic Resins
;
Axis, Cervical Vertebra
;
Ceramics
;
Collodion
;
Composite Resins
;
Crowns
;
Denture, Partial, Fixed
;
Electrons
;
Hot Temperature
;
Humans
;
Lithium Compounds
;
Mouth
;
Platinum
;
Polyurethanes
;
Reinforcement (Psychology)
;
Sprains and Strains
;
Tooth
;
Waxes
8.Full-mouth rehabilitation in an amelogenesis imperfecta patient with anterior open bite using CAD/CAM system.
Sang Hoon LEE ; Yang Jin YI ; Deuk Won JO
The Journal of Korean Academy of Prosthodontics 2017;55(4):410-418
Amelogenesis imperfecta characterized as abnormally formed enamel is caused by a defect of unique group of genes. Patients affected by this disease might have difficulties in social and psychological aspects due to non-esthetic teeth as well as functional problems caused by enamel detachment and tooth wear from their early ages. Adult patients with amelogenesis imperfecta can be treated with full-mouth restorations, which make functional and esthetic rehabilitations of severely worn tooth. However, the anterior open bite and lack of occlusal clearance for posterior teeth restorations due to compensatory extrusion are the intervening factors in the prosthetic treatment. Therefore, the determination of anterior tooth lengths, vertical dimension, and anterior guidance should be set carefully. Recently, computer-aided design and computer-aided manufacturing (CAD/CAM) techniques help systematic approaches and enable dentists to reduce time-consuming procedures in the diagnosis and treatment of full-mouth rehabilitation. This case report demonstrates the successful full mouth rehabilitation using a CAD/CAM system in a young adult patient with amelogenesis imperfecta and anterior open bite.
Adult
;
Amelogenesis Imperfecta*
;
Amelogenesis*
;
Computer-Aided Design
;
Dental Enamel
;
Dentists
;
Diagnosis
;
Humans
;
Mouth Rehabilitation
;
Open Bite*
;
Rehabilitation*
;
Tooth
;
Tooth Wear
;
Vertical Dimension
;
Young Adult
9.Modified Acellularization for Successful Vascular Xenotransplantation.
Won Min JO ; Young Sang SOHN ; Young Ho CHOI ; Hark Jei KIM ; Hyun Deuk CHO
Journal of Korean Medical Science 2007;22(2):262-269
The purpose of this study was to estimate the possibilities of an acellular matrix using a modified acellularization protocol, which circumvents immunological, microbiological, and physiological barriers. We treated porcine subclavian arteries with various reagents to construct acellular grafts. Afterwards, these grafts were interposed in a mongrel dogs' abdominal aorta. Six dogs underwent interposition with fresh porcine grafts (control group), and seven had interposed acellular grafts (acellular group). The control and acellular group dogs were sacrificed at 1, 3, 5 (n=2 in each group) and 12 months (n=1 in acellular group) after the operation. Histopathological examinations were then performed, to assess the degree to which re-endothelialization, inflammation, thrombus formation, and calcification occurred. The entire acellular group, but none of the control group, exhibited re-endothelialization. The degrees to which inflammation, thrombosis, and calcification occurred were found to be lower in the acellular group. We also discovered many smooth muscle cells in the medial layer of the xenograft that had been implanted in the dog sacrificed 12 months after the operation. These results suggest that the construction of xenografts using our modified acellularization protocol may offer acceptable outcomes as a vascular xenograft.
Transplantation, Heterologous/*methods
;
Tissue Engineering/*methods
;
Swine
;
Subclavian Artery/*cytology/*transplantation
;
Graft Survival/*physiology
;
Dogs
;
Cell-Free System/*transplantation
;
Animals
10.Randomized clinical trial to evaluate the efficacy and safety of two types of sandblasted with large-grit and acid-etched surface implants with different surface roughness
Jun-Hyung JEON ; Min-Joong KIM ; Pil-Young YUN ; Deuk-Won JO ; Young-Kyun KIM
Journal of the Korean Association of Oral and Maxillofacial Surgeons 2022;48(4):225-231
Objectives:
This study aims to evaluate the efficacy and safety of two types of sandblasted with large-grit and acid-etched (SLA) surface implants with different surface roughness.
Patients and Methods:
This study was conducted based on a clinical record review of 55 patients (mean age, 53.00 years). A total of 80 SLA surface implants was placed. Among the 80 implants, 38 implants placed in 29 subjects had surface roughness (Ra) of 3.09 µm (test group, TG), while the other 42 implants placed in 31 subjects had a surface roughness (Ra) of 2.50 µm (control group, CG). A comparison was made of implant primary/ secondary stability; success and survival rates; marginal bone loss; and soft tissue assessment including probing pocket depth (PPD), plaque index (PI), gingival index (GI), and bleeding on probing (BOP) between the groups at 1 year after implant placement.
Results:
Among the implants that were initially registered, 1 from the TG and 4 from the CG dropped out, leaving 37 implants in the TG and 38 implants in the CG to be traced and analyzed. Although 1 TG case showed unstable primary stability, all cases showed stable secondary stability. Success and survival rates at 1 year after implant placement were 100% in both groups. Marginal bone loss was 0.07 mm and 0.00 mm for the TG and CG, respectively, but the difference was not significant. Among the several parameters for evaluation of soft tissue, the TG showed lower PI at 1 year after implant placement (TG=0.00, CG=0.29; P=0.0004), while the remaining categories showed no significant difference between the groups.
Conclusion
This study shows that the two types of SLA implants with different surface roughness have no difference in efficacy or safety. Therefore, both of the implants can be used safely and with promising outcomes.